Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed control and estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Machine-learning-aided cognitive reconfiguration for flexible-bandwidth HPC and data center networks [Invited]

This paper proposes a machine-learning (ML)-aided cognitive approach for effective bandwidth reconfiguration in optically interconnected datacenter/high-performance computing (HPC) systems. The proposed approach relies on a Hyper-X-like architecture augmented with flexible-bandwidth photonic interconnections at large scales using a hierarchical intra/inter-POD photonic switching layout. We first formulate the problem of the connectivity graph and routing scheme optimization as a mixed-integer linear programming model. A two-phase heuristic algorithm and a joint optimization approach are devised to solve the problem with low time complexity. Then, we propose an ML-based end-to-end performance estimator design to assist the network control plane with intelligent decision making for bandwidth reconfiguration. Numerical simulations using traffic distribution profiles extracted from HPC applications traces as well as random traffic matrices verify the accuracy performance of the ML design estimator ( < <#comment/> 9 % <#comment/> error) and demonstrate up to 5 × <#comment/> throughput gain from the proposed approach compared with the baseline Hyper-X network using fixed all-to-all intra/inter-portable data center interconnects.

Chen, Xiaoliang (ORCID:0000000278056237)↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Distributed Dynamic State Estimation with Extended Kalman Filter

Increasing complexity associated with large-scale renewable resources and novel smart-grid technologies necessitates real-time monitoring and control. Our previous work applied the extended Kalman filter (EKF) with the use of phasor measurement data (PMU) for dynamic state estimation. However, high computation complexity creates significant challenges for real-time applications. In this paper, the problem of distributed dynamic state estimation is investigated. One domain decomposition method is proposed to utilize decentralized computing resources. The performance of distributed dynamic state estimation is tested on a 16-machine, 68-bus test system.

42 ENGINEERING↗

TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy

Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), the cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

Potential benefits of dosimetric VMAT tracking verified with 3D film measurements

Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. Conclusions: The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.

60 APPLIED LIFE SCIENCES↗

Spatio-Temporal Characterization of Synchrophasor Data Against Spoofing Attacks in Smart Grids

“Source ID Mix” has emerged as a new type of highly deceiving attack which can alter the source information of synchrophasor data measured by multiple phasor measurement units, thereby paralyzing many wide-area measurement systems applications. To address such sophisticated cyber attacks, we have exploited the spatio-temporal characteristics of synchrophasor data for authenticating measurements’ source information. Specifically, the source authentication is performed when the measurements are subjected to three types of spoofing attacks. Some practical difficulties in applying the proposed method on real-time authentication caused by insufficient measurement data have also been solved. Experimental results with real synchrophasor measurements have validated the effectiveness of the proposed method in detecting such complicated data spoofing and improving power systems’ cyber security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Side-looking radar mosaicking experiment

A block of 24 overlapping synthetic aperture side-looking radar images flown over a well mapped area of about 90,000 sq km provided an opportunity to evaluate the mapping accuracy achieved in current radar mosaicking projects. The maps of scale 1:24,000 that are available in the imaged area permitted the study of the geometric errors of the radar mosaics and of individual radar strips. An estimate was obtained for the effect of the distribution and density of ground control points and for the accuracy of different mosaicking methods that are currently employed with synthetic aperture radar images. It is shown that a successful radar mosaicking process requires the elimination of image errors of up to several kilometers. These errors are introduced as a result of the limited precision of the inertial aircraft navigation. An example of a radar mapping effort in which the navigation errors could be eliminated is presented. The resulting radar mosaics have residual RMS mapping errors of planimetry of about plus or minus 150 m.

Leberl, F.↗

NASA Tech Briefs, December 2011

Topics covered include: 1) SNE Industrial Fieldbus Interface; 2) Composite Thermal Switch; 3) XMOS XC-2 Development Board for Mechanical Control and Data Collection; 4) Receiver Gain Modulation Circuit; 5) NEXUS Scalable and Distributed Next-Generation Avionics Bus for Space Missions; 6) Digital Interface Board to Control Phase and Amplitude of Four Channels; 7) CoNNeCT Baseband Processor Module; 8) Cryogenic 160-GHz MMIC Heterodyne Receiver Module; 9) Ka-Band, Multi-Gigabit-Per-Second Transceiver; 10) All-Solid-State 2.45-to-2.78-THz Source; 11) Onboard Interferometric SAR Processor for the Ka-Band Radar Interferometer (KaRIn); 12) Space Environments Testbed; 13) High-Performance 3D Articulated Robot Display; 14) Athena; 15) In Situ Surface Characterization; 16) Ndarts; 17) Cryo-Etched Black Silicon for Use as Optical Black; 18) Advanced CO2 Removal and Reduction System; 19) Correcting Thermal Deformations in an Active Composite Reflector; 20) Umbilical Deployment Device; 21) Space Mirror Alignment System; 22) Thermionic Power Cell To Harness Heat Energies for Geothermal Applications; 23) Graph Theory Roots of Spatial Operators for Kinematics and Dynamics; 24) Spacesuit Soft Upper Torso Sizing Systems; 25) Radiation Protection Using Single-Wall Carbon Nanotube Derivatives; 26) PMA-PhyloChip DNA Microarray to Elucidate Viable Microbial Community Structure; 27) Lidar Luminance Quantizer; 28) Distributed Capacitive Sensor for Sample Mass Measurement; 29) Base Flow Model Validation; 30) Minimum Landing Error Powered-Descent Guidance for Planetary Missions; 31) Framework for Integrating Science Data Processing Algorithms Into Process Control Systems; 32) Time Synchronization and Distribution Mechanisms for Space Networks; 33) Local Estimators for Spacecraft Formation Flying; 34) Software-Defined Radio for Space-to-Space Communications; 35) Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding; and 36) Molecular Adsorber Coating

Source record↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.

60 APPLIED LIFE SCIENCES↗

Full State Feedback Control for Virtual Power Plants

This report presents an object-oriented implementation of full state feedback control for virtual power plants (VPP). The components of the VPP full state feedback control are (1) objectoriented high-fidelity modeling for all devices in the VPP; (2) Distribution System Distributed Quasi-Dynamic State Estimation (DS-DQSE) that enables full observability of the VPP by augmenting actual measurements with virtual, derived and pseudo measurements and performing the Quasi-Dynamic State Estimation (QSE) in a distributed manner, and (3) automated formulation of the Optimal Power Flow (OPF) in real time using the output of the DS-DQSE, and solving the distributed OPF to provide the optimal control commands to the DERs of the VPP.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studies relating to temperature control of a large scale telescope

Analytical methods are developed for estimating the circumferential and longitudinal temperature distributions in a large space telescope, idealized as a simple insulated tube with a flat mirror across one end. The effects of wall conduction, multilayer insulation, thermal coatings, heat pipes, and heated collars are analyzed, with numerical examples. For most of the study, the only thermal input to the tube was assumed to be from steady solar irradiation from one side, as in a geosynchronous orbit. Unsteady heat flow through the insulation, as in alternating sunlight and shadow of a low orbit, is briefly discussed.

Katzoff, S.↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Performance of Multi-Area State Estimation Using Spectral Clustering

This paper investigates the problem of dividing a large power system into several areas to be solved by a state estimator which coordinates locally obtained decentralized estimates. By applying automatic partitioning to the utility system, the performance of the distributed state estimator can be improved as compared to the pre-defined utility control areas. The presented approach utilizes the spectral properties of the un-directed graph formed by assigning a vertex to every bus and an edge to every pair of buses connected by a line. The graph Laplacian matrix and associated eigenvectors and eigenvalues are used to cluster the graph vertices in such a way that each area has a large number of internal connections, but a small number of external connections. This approach is demonstrated using the IEEE 118 bus system.

Kelle, David↗

Impact of wetland decline on decreasing dissolved organic carbon concentrations along the Mississippi River continuum

Prior to discharging to the ocean, large rivers constantly receive inputs of dissolved organic carbon (DOC) from tributaries or fringing floodplains and lose DOC via continuous in situ processing along distances that span thousands of kilometers. Current concepts predicting longitudinal changes in DOC mainly focus on in situ processing or exchange with fringing floodplain wetlands, while effects of heterogeneous watershed characteristics are generally ignored. We analyzed results from a 17-year time-series of DOC measurements made at seven sites and three expeditions along the entire Mississippi River main channel with DOC measurements made every 17 km. The results show a clear downstream decrease in DOC concentrations that was consistent throughout the entire study period. Downstream DOC decreases were primarily (~63–71%) a result of constant dilutions by low-DOC tributary water controlled by watershed wetland distribution, while in situ processing played a secondary role. We estimate that from 1780 to 1980 wetland loss due to land-use alterations caused a ca. 58% decrease in in DOC concentrations in the tributaries of the Mississippi River. DOC reductions caused by watershed wetland loss likely impacted the capacity for the river to effectively remove nitrogen via denitrification, which can further exacerbate coastal hypoxia. Lastly, these findings highlight the importance of watershed wetlands in regulating DOC longitudinally along the headland to ocean continuum of major rivers.

54 ENVIRONMENTAL SCIENCES↗

An active optimal control strategy of rotor vibrations using external forces

An active control strategy for lateral rotor vibrations using external forces is proposed. An extended state observer is used to reconstruct the full states and the unbalance distribution. An optimal controller which accommodates persistent unbalance excitation is derived with feedback of estimated states and unbalances. Numerical simulations were conducted for two separate four degree of freedom rotor systems. These simulations indicated that the proposed strategy can achieve almost complete vibration cancellation. This was shown to be true even when the number of external control forces was less than the system order so long as coordinate coupling was present. Both steady state and transient response at a constant speed are presented.

Zhu, W.↗