Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Testing the DIII-D co/counter off-axis neutral beam injected power and ability to balance injected torque

DIII-D has undergone a major upgrade and successfully injected high power off-axis neutral beams (~4 MW) in both co-current and counter-current directions. This capability of high power co/counter steerable off-axis neutral beams on a major tokamak opens a unique parameter space of broad pressure and current profiles for high beta steady-state advanced tokamak (AT) scenarios, while retaining the ability to balance the injected torque for low rotation studies. This co/counter off-axis neutral beam capability is being used to validate physics-based energetic particle and thermal transport models for designing next-step facilities based on the steady-state AT approach. This paper reports on the critical evaluation of the transmitted power and energetic ion population produced by this heating and current drive system, which is assessed through visible imaging, neutron measurements and rotation profile measurements at balanced torque. Minimal losses of neutral beam power have been achieved by optimizing the strongly focused ion sources required to pass through the aperture. Tilting of the ion source has been guided by fast visible imaging and resulted in neutral beam injection along the design centerline with empirical characterization of each beam's divergence derived from the imaging data and used in the NUBEAM description of the beam injection. Through exclusive power injection of each neutral beam into MHD quiescent plasmas across a range of neutral beam voltage, perveance and plasma current we conclude that a modest reduction (~10%–15%) of transmitted power compared to on-axis, standard focus has been incurred. We report corrections that more accurately represent the injected power. Good ability to balance the neutral beam torque has been demonstrated by injecting the new off-axis counter injecting beam against the existing off-axis co-injected beam in 2.0 T, 1.0 MA, MHD quiescent L-mode plasmas. Furthermore, the torque balance studies verify the ability to operate with balanced injection, which is critical for achieving low torque and low rotation operation for physics studies and in ITER demonstration discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of collisional ion orbit loss on tokamak radial electric field and toroidal rotation in an L-mode plasma

Abstract Ion orbit loss has been used to model the formation of a strong negative radial electric field E r in the tokamak edge, as well as edge momentum transport and toroidal rotation. To quantitatively measure ion orbit loss, an orbit-flux formulation has been developed and numerically applied to the gyrokinetic particle-in-cell code XGC. We study collisional ion orbit loss in an axisymmetric DIII-D L-mode plasma using gyrokinetic ions and drift-kinetic electrons. Numerical simulations, where the plasma density and temperature profiles are maintained through neutral ionization and heating, show the formation of a quasisteady negative E r in the edge. We have measured a radially outgoing ion gyrocenter flux due to collisional scattering of ions into the loss orbits, which is balanced by the radially incoming ion gyrocenter flux from confined orbits on the collisional time scale. This suggests that collisional ion orbit loss can shift E r in the negative direction compared to that in plasmas without orbit loss. It is also found that collisional ion orbit loss can contribute to a radially outgoing (counter-current) toroidal-angular-momentum flux, which is not balanced by the toroidal-angular-momentum flux carried by ions on the confined orbits. Therefore, the edge toroidal rotation shifts in the co-current direction on the collisional time scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Left-right canted-cosine-theta magnets

Disclosed herein are superconducting gantry magnets that include multiple quadrupole winding sections placed in sequence on a curve such that the effective current direction is reversed between sections. This produces alternating quadrupole field regions along the length of the bend whose individual integral strengths can be tuned by the location of the current polarity transitions. A simple transition scheme to reverse the current between sections can be implemented to allow for the use of one continuous winding and power supply. Dipole windings can be included in the superconducting gantry magnets so that the magnets produce superposed dipole and alternating quadrupole fields. The disclosed design for the windings and transition scheme to reverse current polarity can be implemented for higher order multipoles as well.

43 PARTICLE ACCELERATORS↗

Neutrinos for TeV neutralinos

One of the most well-founded candidates for dark matter remains a split-supersymmetry (SUSY) model with a Higgsino- or winolike lightest superpartner and the grander SUSY model providing answers for the hierarchy problem and grand unified theory scale unification. The relatively heavy scalar superpartners imply such models would not yet be seen at collider experiments, and mixing-suppressed couplings place such models outside the reach of current direct detection experiments. As such particles annihilate fairly readily to electroweak bosons, a significant neutrino signal can arise near the Galactic Center that may be visible to dedicated searches at current and future neutrino telescopes. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

Flux Upcycling of Degraded Layered Cathodes to LiNi x Mn y Co z O 2 (NMCs) with Gradient Transition Metal Distribution

The rising demand for lithium-ion batteries (LIBs) has intensified the need for efficient recycling methods to address both supply chain constraints and environmental impacts. Direct upcycling, distinguished by its ability to achieve both the structural and compositional integrity of cathode materials, has gained prominence as a sustainable alternative to conventional pyrometallurgical and hydrometallurgical processes. However, the current direct upcycling methods are typically limited by incorporating Li and/or Ni, significantly constraining the adaptability across diverse LiNi x Mn y Co z O 2 (NMCs). Here, in this study, a versatile molten salt approach is reported that expands the scope of direct upcycling by enabling simultaneous incorporation of Li, Ni, and Mn. This methodology facilitates flexible conversion among diverse NMC compositions, including non-stoichiometric Co/Mn systems such as upcycling degraded LiCoO 2 (D-LCO), LiNi 1/3 Mn 1/3 Co 1/3 O 2 (D-NMC111), LiNi 0.8 Mn 0.1 Co 0.1 O 2 (D-NMC811) to surface Mn enriched NMC111, LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC532), and NMC811, respectively. The gradient transition metal distribution in upcycled products, characterized by Mn-enriched outer layers and Co/Ni-enriched cores enhances the interfacial stability of NMC cathodes, addressing critical challenges in long-term performance and structural integrity. These results highlight the potential of flux methods for advancing the upcycling of spent cathodes and producing high-performance materials for next-generation LIBs applications.

lithium -ion batteries↗

Electron beam injection from a hollow cathode plasma into a downstream reactive environment: Characterization of secondary plasma production and Si 3 N 4 and Si etching

A material etching system was developed by combining beam electron injection from a direct current (DC) hollow-cathode (HC) electron source with the downstream reactive environment of a remote CF 4 /O 2 low temperature plasma. The energy of the injected beam electrons is controlled using an acceleration electrode biased positively relative to the HC Argon discharge. For an acceleration voltage greater than the ionization potential of Ar, the extracted primary electrons can produce a secondary plasma in the process chamber. We characterized the properties of the secondary plasma by performing Langmuir probe measurements of the electron energy probability function (EEPF) 2.5 cm below the extraction ring. The data indicate the existence of two major groups of electrons, including electrons with a primary beam electron energy which varies as the acceleration voltage is varied, along with low energy electrons produced by ionization of the Ar gas atoms in the process chamber by the injected beam electrons. When combining the HC Ar beam electron with a remote CF 4 /O 2 electron cyclotron wave resonance (ECWR) plasma, the EEPF of both the low energy plasma electron and beam electron components decreases. Additionally, we studied surface etching of Si3N4 and poly-crystalline Si (poly-Si) thin films as a function of process parameters, including the acceleration voltage (0-70 V), discharge current of the HC discharge (1-2 A), pressure (2- 100 mTorr), source to substrate distance (2.5 to 5 cm), and feed gas composition (with or without CF 4 /O 2 ). The direction of the incident beam electrons was perpendicular to the surface. Si 3 N 4 and poly-crystalline silicon etching are seen and indicate an electronneutral synergy effect. No/little remote plasma spontaneous etching was observed for the conditions used in this study, and the etching is confined to the substrate area irradiated by the injected beam electrons. The electron etched Si 3 N 4 surface etching rate profile distribution is confined within a ~30 mm diameter circle, which is slightly broader than the area for which poly-Si etching is seen, and coincides closely with the spatial profile of beam electrons as determined by the Langmuir probe measurements. The magnitude of poly-Si etching rate is by a factor of two times smaller than the Si 3 N 4 etching rate. In this paper, we discuss possible explanations of the data and the role of surface charging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Printed circuit board for integrated LED driver

A light emitting diode (LED) module may include a direct current (DC) voltage node formed on a first layer. The DC voltage node may be configured to sink a first current. One or more devices may be formed on the first layer configured to provide a second current to one or more LEDs. A device of the one or more devices may carry a steep slope voltage waveform. A local shielding area may be formed in a second layer directly below the DC voltage node and the one or more devices. The local shielding area may include a substantially continuous area of conductive material. A conductive via may extend through one or more layers. The conductive via may electrically connect the DC voltage node and the local shielding area.

Song, Zhihua↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

Vascular endothelial and smooth muscle cell galvanotactic response and differential migratory behavior

Chronic disease or injury of the vasculature impairs the functionality of vascular wall cells particularly in their ability to migrate and repair vascular surfaces. Under pathologic conditions, vascular endothelial cells (ECs) lose their non-thrombogenic properties and decrease their motility. Alternatively, vascular smooth muscle cells (SMCs) may increase motility and proliferation, leading to blood vessel luminal invasion. Current therapies to prevent subsequent blood vessel occlusion commonly mechanically injure vascular cells leading to endothelial denudation and smooth muscle cell luminal migration. Due to this dichotomous migratory behavior, a need exists for modulating vascular cell growth and migration in a more targeted manner. Here, we examine the efficacy of utilizing small direct current electric fields to influence vascular cell-specific migration (“galvanotaxis”). We designed, fabricated, and implemented an in vitro chamber for tracking vascular cell migration direction, distance, and displacement under galvanotactic influence of varying magnitude. Our results indicate that vascular ECs and SMCs have differing responses to galvanotaxis; ECs exhibit a positive correlation of anodal migration while SMCs exhibit minimal change in directional migration in relation to the electric field direction. SMCs exhibit less motility response (i.e. distance traveled in 4 h) compared to ECs, but SMCs show a significantly higher motility at low electric potentials (80 mV/cm). With further investigation and translation, galvanotaxis may be an effective solution for modulation of vascular cell-specific migration, leading to enhanced endothelialization, with coordinate reduced smooth muscle in-migration.

60 APPLIED LIFE SCIENCES↗

Effects of hydrogen partial pressure on crack initiation and growth rate in vintage X52 steel

There is an increasing interest in ensuring compatibility of existing natural gas infrastructure with conveyance of hydrogen, especially for vintage (pre-1970s) pipeline steels. While hydrogen is known to affect the fatigue and fracture resistance of these materials, there is a lack of data on its effects on crack initiation at low hydrogen partial pressure. To address this gap, the current work presents a series of fatigue tests on vintage API Grade X52 steel in pure nitrogen, air and gaseous hydrogen at partial pressures of 1 and 207 bar. Circumferential notch tension (CNT) specimens with direct current potential difference (DCPD) measurements are used to get S–N curves for crack initiation and failure, and compact tension (CT) tests to assess crack growth rates. Results indicate that air accelerates crack initiation, low hydrogen partial pressure affects the crack growth rate, and higher pressures have the largest impact on both. Surprisingly, crack initiation is faster in air than at 1 bar hydrogen partial pressure. The CNT tests also reveal that the orientation of the banded microstructure has no effect on the crack initiation site, but it influences its growth behavior. Moreover, fractography shows that hydrogen also promotes instances of quasi-cleavage and intergranular fracture, linked to embrittlement of the material. Here, these results demonstrate that, while hydrogen may impact the entirety of the fatigue process, its effects on the early stages of damage accumulation become relevant only at larger pressures. More comprehensive studies of crack initiation in hydrogen atmospheres will be critical to future codes and standards for hydrogen infrastructure.

Circumferential notch tension↗

Public electric vehicle charging station utilization in the United States

The utilization of electric vehicle (EV) charging equipment is a key driver of charging station economics, but current trends and factors related to the utilization of public charging infrastructure in the United States are not well understood. This study analyzes EV charging data from 3,705 nationwide public Level 2 (L2) and direct current fast charging (DCFC) stations over 2.5 years (2019-2022), observing utilization patterns over time. Regression analysis is used to assess the relationships between station utilization and several contextual and environmental factors. We conclude that local EV adoption is a strong indicator of utilization; L2 station utilization decreases with the size of the local charging network, while DCFC stations are less affected; and increased charging power has a greater effect on utilization for DCFC stations than L2. This study fills a critical research gap by reporting updated public charging station utilization statistics and analysis for the U.S. market.

33 ADVANCED PROPULSION SYSTEMS↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Refueling Infrastructure Deployment in Low-Income and Non-Urban Communities

The U.S. National Blueprint for Transportation Decarbonization identifies the need to invest in infrastructure supporting low- and zero-emission vehicles, especially in low-income and overburdened communities, to eliminate nearly all greenhouse gas emissions from the transportation sector by 2050. The alternative fuel vehicle refueling property tax credit (26 U.S. Code § 30C) includes eligibility criteria intended to encourage investment in underserved communities based on the economic characteristics or urban character of the census tract in which the fueling infrastructure is installed. Eligible census tracts are those that qualify for the New Markets Tax Credit or that are not located within urban areas as defined by the U.S. Census Bureau. This study quantifies how many fueling-related amenities are currently located in census tracts that qualify and do not qualify for the 30C tax credit based on IRS Notice 2024-20. For existing electric vehicle charging stations, 51% of Level 2 and 60% of Direct Current Fast Charging public stations are located in eligible census tracts. 73% of natural gas, propane, and hydrogen fueling stations are in qualifying census tracts and 75% of biodiesel and renewable fuel stations are in qualifying census tracts. This compares with 73% of existing gas stations in eligible census tracts. For deploying the refueling infrastructure to satisfy future demand, this study shows that truck stops (94%), commercial truck stops (92%), and Federal Highway alternative fuel corridors (89%) are predominantly located in eligible locations. Additionally, significant percentages of the population (62%), light-duty vehicle registrations (64%), and medium- and heavy-duty vehicle registrations (68%) fall within eligible areas.

33 ADVANCED PROPULSION SYSTEMS↗

Sputter deposition of Ta 1 W 1 Au 1 Bi 7 films for next generation hohlraums

Hohlraum simulation predicts a higher x-ray drive from Ta 1 W 1 Au 1 Bi 7 compared with our current Au hohlraum. Here, we study the effect of deposition process parameters including deposition rate, working pressure, target-to-substrate distance, substrate bias, and substrate temperature on the microstructure of Ta1W1Au1Bi7 films deposited by direct current magnetron sputtering onto planar substrates. We found that the substrate temperature has a pronounced effect on the film microstructure. This is attributed to the Bi low melting point (271°C) causing its adatom mobility to be strongly dependent on the substrate temperature. Additionally, we observed phase separation for films deposited with a high substrate bias. These results have important implications for the development of a robust Ta 1 W 1 Au 1 Bi 7 hohlraum fabrication process.

36 MATERIALS SCIENCE↗

Port of New York and New Jersey Drayage Electrification Analysis

The National Renewable Energy Laboratory (NREL) evaluated the potential for drayage electrification in the Port of New York and New Jersey (PoNYNJ), with a focus on operators: Harbor Freight Transport (HF), Safeway Trucking (SWT), and International Motor Freight Inc (IMF). This report summarizes the data collection and electrification evaluation of all three drayage operators, includes detailed operational data, and identifies the performance requirements for battery electric tractors (BETs) and corresponding infrastructure operated within the context of PoNYNJ drayage operation. This report also details a methodology to evaluate opportunities, strategies, and challenges associated with future expansions of BETs in meeting PANYNJ emissions goals. The Port Authority has established a goal of achieving Net Zero carbon emissions by 2050 across all facilities, including from tenant and stakeholder sources such as drayage trucks. NREL used real-world performance data collected on the three PoNYNJ drayage operations, along with modeling and analysis tools to compare BET to diesel trucks. From March to July 2021, NREL collected 1Hz vehicle and engine data from 46 drayage trucks at the three operators totaling nearly 121,000 miles of operation, providing enough information to assess vehicle operations for electrification potential. A Future Automotive Systems Technology Simulator (FASTSim) electric truck powertrain model was validated using PoNYNJ data and scenarios were run to evaluate drayage truck electrification requirements over the real-world cycles. The first scenario examined BET viability with minimal changes to existing operations. This assumes the trucks charge when stopped for two hours or longer, have a functional battery size of 375 kWh, and can charge at 270 kilowatts (kW) average which are the specification of the commercially available Freightliner eCascadia. The second scenario looked at what operational, charging infrastructure, and BET technology changes would be needed to fully electrify. Finally, detailed analysis was run on charging rate structure to understand operational costs to the fleets. The studied drayage trucks averaged 5.1 MPG, spent roughly 9% of their energy at idle, and drove an average of 140 miles per day with a maximum daily distance of 573 miles. The FASTSim model results indicate a comparable BET would use 417 kWh of energy per day on average accounting for cargo weight, which is close to the full usable capacity of the eCascadia currently available on the market. Based on the daily average operating data, partial fleet electrification is possible with current technology. However, some specific days of operation would require over 1,600 kWh of energy due to longer distances traveled by the trucks and more intense operation. Trucks used for long distance and intense operation cannot be readily electrified with current technology without operational changes. Full adoption of BETs could reduce CO 2 emissions from these fleets by roughly 75% today, eliminating 76 metric tons of CO 2 (MTCO 2 ) per vehicle each year, which equates to 24,100 MTCO 2 per year for all three operators. Commercially available direct current fast chargers (DCFC) have charge rates up to 350 kW. Based on the average daily modeled energy use for each operator, current industrial rate structures, and the assumption of 350 kW peak charging, full drayage electrification would increase electricity consumption. In addition, peak demand usage would increase with unmanaged charging along with cost of electricity having a direct impact on cost per mile for electric vehicles. The resulting cost per mile for BETs along with comparable cost per mile for conventional diesel trucks are also examined at $\$$4.00 per gallon of diesel. It will be important for PANYNJ and the drayage operators within the PoNYNJ to consider these load impacts to their existing electrical infrastructure and devise operational strategies that avoid coincident charging of vehicles to mitigate demand charges. Despite these electricity cost increases, savings from reductions in diesel consumption will help offset the costs of this increased electricity consumption. However, prices of both electricity and diesel are subject to change based on various factors meaning the realized savings will vary over time. This shows BETs could be cost-competitive on an energy cost per mile basis for all scenarios while diesel is above $\$$3.00/gal. Further, if diesel prices dropped to the 15-year low of $2.33/gal, it would still be cost competitive to operate the EVs with electricity costs of 16.3 ¢/kWh or less.

33 ADVANCED PROPULSION SYSTEMS↗

Three-dimensional modelling of a self-sustained atmospheric pressure glow discharge

The atmospheric pressure glow discharge (APGD) is a relatively simple and versatile plasma source used in diverse applications. Stable APGD operation at high currents, generally a challenge due to instabilities leading to glow-to-arc transition, has been demonstrated using actively-controlled cathodic cooling. This article presents the computational modelling and simulation of a self-sustained direct-current APGD in helium within a 10 mm pin-to-plate inter-electrode gap for currents ranging from 4 to 40 mA. The APGD model is comprised of the conservation equations for total mass, chemical species, momentum, thermal energy of heavy-species and of free electrons, and electric charge. The model equations are discretized using a nonlinear variational multi-scale finite element method that has demonstrated superior accuracy in other plasma flow problems, on a temporal and three-dimensional computational domain suitable to unveil the potential occurrence of instabilities. Modelling results show good agreement with experimental measurements of voltage drop and the same trend but higher values of temperature. The higher temperatures obtained by the simulations appear to be due to the absence of a near-cathode heat dissipation model. Here, the results also reveal that the distribution of electron density and of the ratio of atomic helium ions to total ions transitions from monotonically increasing away from the cathode to presenting a minimum near the centre of the gap with increasing current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗