Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital volume correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impact Ice Adhesion at NASA Glenn: Current Experimental Methods and Supporting Measurements

When examining the literature on the adhesion strength of impact ice, there have been a wide range of methodologies tried to measure the required stresses to induce interfacial delamination. Utilizing the Icing Research Tunnel at the NASA Glenn Research Center to generate the impact ice required for this work, several different mechanical tests have been and are being developed to determine the stresses along the interface between ice and coupon. This set of tests includes the technical mature modified lap joint test which has been used to conduct ice adhesion studies through a wide sweep of icing conditions. To conduct in situ ice adhesion measurements inside of the Icing Research Tunnel, several new experiments are currently being developed to make ice adhesion measurements during and immediately after ice accretion. In addition to these experimental methods, several supporting measurement techniques have been developed to allow for a better understanding on the influence of icing cloud conditions on the mechanical behavior of impact ice. Digital image correlation has been successfully implemented to augment the data generated by the modified lap joint test with full field surface displacement and strain measurements which allow for insight into the deformation processes present during a test. Both optical microscopy of impact ice samples along with ice replication techniques have been used to study the grain structure of the impact ice. This has led to a deeper understanding of the results from the modified lap joint method and how the structure of impact ice changes as it is accreted during an icing spray. The freezing process of impact ice generated by supercooled liquid water is not a volume conserving process, which leads to the presence of residual strains along the interface between ice and substrate. These strains have been observed using both a simplified flat geometry and a representative airfoil. The data gathered by these experimental adhesion methods and supporting measurements allows for a comprehensive understanding on the behavior of impact ice which will be critical to the development of future ice shedding models.

Ice Adhesion↗

Impact Ice Adhesion at NASA Glenn: Current Experimental Methods and Supporting Measurements

When examining the literature on the adhesion strength of impact ice, there have been a wide range of methodologies tried to measure the required stresses to induce interfacial delamination. Utilizing the Icing Research Tunnel at the NASA Glenn Research Center to generate the impact ice required for this work, several different mechanical tests have been and are being developed to determine the stresses along the interface between ice and coupon. This set of tests includes the technical mature modified lap joint test which has been used to conduct ice adhesion studies through a wide sweep of icing conditions. To conduct in situ ice adhesion measurements inside of the Icing Research Tunnel, several new experiments are currently being developed to make ice adhesion measurements during and immediately after ice accretion. In addition to these experimental methods, several supporting measurement techniques have been developed to allow for a better understanding on the influence of icing cloud conditions on the mechanical behavior of impact ice. Digital image correlation has been successfully implemented to augment the data generated by the modified lap joint test with full field surface displacement and strain measurements which allow for insight into the deformation processes present during a test. Both optical microscopy of impact ice samples along with ice replication techniques have been used to study the grain structure of the impact ice. This has led to a deeper understanding of the results from the modified lap join method and how the structure of impact ice changes as it is accreted during an icing spray. The freezing process of impact ice generated by supercooled liquid water is not a volume conserving process, which leads to the presence of residual strains along the interface between ice and substrate. These strains have been observed using both a simplified flat geometry and a representative airfoil. The data gathered by these experimental adhesion methods and supporting measurements allows for a compressive understanding on the behavior of impact ice which will be critical to the development of future ice shedding models.

Ice Adhesion↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Anisotropy in the Ratchet Growth of PBX 9502

TATB-based compactions and composites are known to undergo “ratchet growth”, an irreversible volume increase that occurs upon heating or cooling of a specimen. Ratchet growth likely arises because the coefficient of thermal expansion of the TATB crystals is strongly anisotropic, but the exact mechanism is not well-understood. TATB crystals in solid, plastic-bonded, explosive PBX 9502 parts can have a preferred crystallographic orientation (texture) caused by the compaction process. As a result, the irreversible strain associated with PBX 9502 ratchet growth is anisotropic. The present paper relates the magnitude of ratchet growth to the crystalline anisotropy of the TATB crystals. The crystalline anisotropy is measured by x-ray diffraction and the ratchet growth is measured by a digital image-correlation technique.

36 MATERIALS SCIENCE↗

ADDGALS: Simulated Sky Catalogs for Wide Field Galaxy Surveys

Abstract We present a method for creating simulated galaxy catalogs with realistic galaxy luminosities, broadband colors, and projected clustering over large cosmic volumes. The technique, denoted Addgals (Adding Density Dependent GAlaxies to Lightcone Simulations), uses an empirical approach to place galaxies within lightcone outputs of cosmological simulations. It can be applied to significantly lower-resolution simulations than those required for commonly used methods such as halo occupation distributions, subhalo abundance matching, and semi-analytic models, while still accurately reproducing projected galaxy clustering statistics down to scales of r ∼ 100 h −1 kpc . We show that Addgals catalogs reproduce several statistical properties of the galaxy distribution as measured by the Sloan Digital Sky Survey (SDSS) main galaxy sample, including galaxy number densities, observed magnitude and color distributions, as well as luminosity- and color-dependent clustering. We also compare to cluster–galaxy cross correlations, where we find significant discrepancies with measurements from SDSS that are likely linked to artificial subhalo disruption in the simulations. Applications of this model to simulations of deep wide-area photometric surveys, including modeling weak-lensing statistics, photometric redshifts, and galaxy cluster finding, are presented in DeRose et al., and an application to a full cosmology analysis of Dark Energy Survey (DES) Year 3 like data is presented in DeRose et al. We plan to publicly release a 10,313 square degree catalog constructed using Addgals with magnitudes appropriate for several existing and planned surveys, including SDSS, DES, VISTA, Wide-field Infrared Survey Explorer, and Rubin Observatory’s Legacy Survey of Space and Time.

79 ASTRONOMY AND ASTROPHYSICS↗

User Interactive Software for Analysis of Human Physiological Data

Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

Cowings, Patricia S.↗

Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation

OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

Non-NASA Center↗

SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15%,respectively.Mean M-ADC for ADC measured from 4D-DWI and M-ADC measured from FB-DWI were (2.29±0.04)*0.001*mm2/s and (3.80±0.01)*0.001*mm2/s,respectively.ADC value ground-truth is 2.24*0.001*mm2/s from the input of the simulation. Conclusion: A respiratory correlated 4D-DWI technique has been initially evaluated in phantoms and a human subject.Comparing to free breathing DWI,4D-DWI can lead to more accurate measurement of ADC.

60 APPLIED LIFE SCIENCES↗

Compact Radar Transceiver with Included Calibration

The Digital Beamforming Synthetic Aperture Radar (DBSAR) is an eight-channel phased array radar system that employs solid-state radar transceivers, a microstrip patch antenna, and a reconfigurable waveform generator and processor unit. The original DBSAR transceiver design utilizes connectorized electronic components that tend to be physically large and heavy. To achieve increased functionality in a smaller volume, PCB (printed circuit board) transceivers were designed to replace the large connectorized transceivers. One of the most challenging problems designing the transceivers in a PCB format was achieving proper performance in the calibration path. For a radar loop-back calibration path, a portion of the transmit signal is coupled out of the antenna feed and fed back into the receiver. This is achieved using passive components for stability and repeatability. Some signal also leaks through the receive path. As these two signal paths are correlated via an unpredictable phase, the leakage through the receive path during transmit must be 30 dB below the calibration path. For DBSAR s design, this requirement called for a 100-dB isolation in the receiver path during transmit. A total of 16 solid-state L-band transceivers on a PCB format were designed. The transceivers include frequency conversion stages, T/R switching, and a calibration path capable of measuring the transmit power-receiver gain product during transmit for pulse-by-pulse calibration or matched filtering. In particular, this calibration path achieves 100-dB isolation between the transmitted signal and the low-noise amplifier through the use of a switching network and a section of physical walls achieving attenuation of radiated leakage. The transceivers were designed in microstrip PCBs with lumped elements and individually packaged components for compactness. Each transceiver was designed on a single PCB with a custom enclosure providing interior walls and compartments to isolate transceiver subsystems from radiated interference. The enclosure also acts as a heat sink for the voltage regulators and power amplifiers inside the system. The PCB transceiver design produces transmit pulses of 2 W with an arbitrary duty cycle. Each transceiver is fed by an external 120-MHz signal transmit and two 1,140-MHz local oscillator signals. The received signal is amplified and down-converted to 120 MHz and is fed to the data processor. The transceiver dimensions are approximately 3.5 11.5 0.6 in. (9 29 1.5 cm). The PCB transceiver design reduces the volume and weight of the DBSAR instrument while maintaining the functionality found in the original design. Both volume and weight are critical for airborne and flight remote sensing instrumentation.

McLinden, Matthew↗

Strength-ductility synergy through microstructural and compositional heterogeneity in directed energy deposition additive manufacturing of face-centered cubic materials

Directed energy deposition (DED) is an additive manufacturing (AM) process based on welding technology and offers the advantages of large build volume, high deposition rate, and ability to fabricate multi-material parts. Epitaxial continuous columnar grain growth is a characteristic microstructural feature of DED processed alloys. In this study, a bamboo-like microstructure (periodic alternation of equiaxed and columnar structure) was produced by adopting an intermittent deposition strategy in 316L stainless steel and Inconel 625. The formation of a bamboo-like alternating microstructure was confirmed through electron backscattered diffraction (EBSD) analysis. Hardness mapping showed that the columnar to equiaxed transition (CET) occurred at the region right below the fusion line. A finite element (FE) model was used to investigate the relationship between the temperature gradient (G) and the solidification rate (R). The FE model showed a low G/R ratio at the region right below the interface promoting the CET. The grain size and material-dependent deformation behaviors are analyzed using digital image correlation (DIC). The lower deformation on the fine-grain regions observed in DIC analysis is attributed to a higher strain hardening rate, which is confirmed through dislocation density analysis on a tensile-interrupted specimen. The periodically alternating grain size coupled with the microstructural changes caused by intermittent deposition strategy result in a better strength-ductility synergy in both single-material and bimetallic specimens.

36 MATERIALS SCIENCE↗

K‐band luminosity–environment relation in three different galaxy samples of the Sloan Digital Sky Survey III

The aim of this work is to examine the environmental dependence of K‐band luminosity in the Main, Low Redshift (LOWZ), and Constant Mass (CMASS) galaxy samples of the Sloan Digital Sky Survey Data Release 10 (SDSS DR10). Overall, the environmental dependence of K‐band luminosity is very mild. In two volume‐limited Main samples with the luminosity −20.5 ≤ M r ≤ −18.5 and −22.5 ≤ M r ≤ −20.5, respectively, we find that the environmental dependence of K‐band luminosity in the luminous volume‐limited Main galaxy sample still can be observed, but this dependence in the faint volume‐limited Main galaxy sample is very weak. Considering the disadvantages of the use of volume‐limited samples, we apply the apparent magnitude‐limited Main galaxy sample, divide the Main galaxy sample of the SDSS DR10 into subsamples with a redshift binning size of Δ z =0.01, and then analyze the environmental dependence of K‐band luminosity of subsamples in each redshift bin. Such a method also is used in the LOWZ and CMASS galaxy samples. K‐band luminosity of the Main galaxies shows substantial correlation with the local environment in many redshift bins. In the LOWZ galaxy sample, K‐band luminosity of galaxies shows substantial correlation with the local environment only in the redshift region 0.16 ≤ z ≤ 0.21, while K‐band luminosity of CMASS galaxy sample is only weakly correlated with the local environment. Statistical results also show that in the apparent magnitude‐limited main galaxy sample and the LOWZ galaxy sample, environmental dependence of K‐band luminosity becomes weak with increasing redshift.

Deng, X. ‐F.↗

A GaN-based Four-Switch Buck-Boost Converter using Ripple Correlation Control for Maximum Power Point Tracking in Dynamic Deep Space Environments

As the demand for high-performance power conversion in spacecraft continues to grow and spacecraft mass and volume budgets become increasingly tight, it is essential to design DC-DC converters with higher efficiency and power density. Although photovoltaic (PV) efficiency has increased over time, solar irradiance and temperatures can fluctuate dramatically in deep space. This causes significant variations in the maximum power point (MPP) of the PV array, which can decrease the overall system efficiency unless accounted for. Thus, it is imperative to track the MPP of the PV panels to maintain optimal efficiency. This paper presents the experimental development of a four-switch, GaN-based buck-boost converter with an implementation of the Ripple Correlation Control (RCC) MPPT algorithm for dynamic deep space environments. Due to the use of GaN HEMTs, the experimental system achieves better efficiency and power density compared to the previous state of the art implementations. A simulation of the prototype buck-boost converter was implemented in SaberRD (Synopsis), and a digital design of the RCC-based MPPT controller utilizing the StateAMS tool is presented. The simulation results show that this controller swiftly and precisely converged to the MPP of the source PV panels in a dynamic solar irradiance condition.

Mahmud, Sadab↗

Characterizing unknown systematics in large scale structure surveys

Photometric large scale structure (LSS) surveys probe the largest volumes in the Universe, but are inevitably limited by systematic uncertainties. Imperfect photometric calibration leads to biases in our measurements of the density fields of LSS tracers such as galaxies and quasars, and as a result in cosmological parameter estimation. Earlier studies have proposed using cross-correlations between different redshift slices or cross-correlations between different surveys to reduce the effects of such systematics. In this paper we develop a method to characterize unknown systematics. We demonstrate that while we do not have sufficient information to correct for unknown systematics in the data, we can obtain an estimate of their magnitude. We define a parameter to estimate contamination from unknown systematics using cross-correlations between different redshift slices and propose discarding bins in the angular power spectrum that lie outside a certain contamination tolerance level. We show that this method improves estimates of the bias using simulated data and further apply it to photometric luminous red galaxies in the Sloan Digital Sky Survey as a case study.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature dependence of protein solubility-determination, application to crystallization, and growth kinetics studies

A scintillation method was developed for determinations of the temperature dependence of the solubility, and of nucleation induction times of proteins, in 50-100 mu(l) volumes of solution. Solubility data for lysozyme and horse serum albumin were obtained for various combinations of pH and precipitant concentrations. These data and the nucleation induction information were used for dynamic crystallization control, that is, for the controlled separation of nucleation and growth stages. Individual lysozyme and horse serum albumin crystals were grown in 15-20 mu(l) solution volumes contained in x-ray capillaries. The morphology and kinetics of the growth and dissolution of lysozyme in aqueous solutions with 2.5 percent NaCl and at pH = 4.5 was studied in situ with a depth resolution of 300 A (4 unit cells) by high resolution optical microscopy and digital image processing. The bulk super- or under saturation, sigma, of the solution inside a closed growth cell was controlled by temperature. The growth habit was bound by (110) and (101) faces that grew through layer spreading, although with different growth rate dependencies on supersaturation/temperature. At sigma less than 10 (obtained at higher temperatures) growth was purely kinetic ally controlled, with impurity effects (macrostep formation and kinetic hindrance) becoming significant for sigma less than 2. At sigma greater than 10 (lower temperatures), anisotropies in the interfacial kinetics were more pronounced, with interfacial kinetics and bulk transport becoming equally important to the growth morphology. Growth rates were growth history dependent. The formation of striations (layers of irregularly incorporated solution) was unambiguously correlated with growth temperature variations. Etching exposed dislocations and various high-index faces whose growth morphologies were studied during return to the steady state growth form. Growth steps were observed to originate from two-dimensional nuclei or from outcrops of growth striations, and from dislocations that preferentially formed in growth sector boundaries.

Rosenberger, Franz↗

In Situ Measurements of Surface Texture with Virtual Environments Support Science-Driven Human Surface Operations on the Moon and Beyond

Visualization tools enabling real-time scientific analysis are important for supporting future astronaut operations on the lunar surface. Such tools can be built into virtual environments to support scientific investigations, as well as situational awareness, real-time decision making, and efficient communication between astronauts and ground and support systems. Understanding how these tools can be optimized for science is essential for upcoming Artemis missions. In this contribution, we discuss how measurements of surface texture at multiple length scales can greatly enhance in situ science on/of the Moon, and eventually Mars, asteroids, and beyond. Roughness measurements at various wavelengths directly support objectives defined in the Artemis Science Plan, including (O1) “understanding planetary processes,” (O2) “understanding volatile cycles,” and (O3) “interpreting the impact history of the Earth-Moon system” . Key scientific analyses enabled by texture measurements at different length scales include: ● Sub-centimeter scales: Texture measurements can help constrain lava flow crystallinity, lava rheology, emplacement flow dynamics, and cooling histories (O1). Measurements of lacunarity (voids in fractal fill space) can shed light on eruptive volatile content, residence time of migrating volatiles, and near-surface volume available for micro-cold trapping of volatiles (O1, O2). ● Centimeter–meter scales: Texture measurements can be used for the differentiation of individual lava flows, the reconstruction of local stratigraphies and emplacement sequences, characterization of post-emplacement surface modification processes (O1, O3). Derived roughness (polarization) metrics can be used in the detection of water ice and characterization of ice properties (e.g., purity, grade, depth, abundance). ● Hectometer–Kilometer scales: Texture measurements can be used to differentiate major geologic surface units and surface structures (O1), constrain the presence of abundant ground ices (O2), and analyze surface modification and estimate surface age (O3). Real-time measurements of surface texture across these multiple length scales will enable efficient sample identification and scientific investigations by future astronauts. To support these investigations and the objective classification of surface texture, virtual environments employed by astronauts should be able to instantaneously convert raw data into processed data (e.g., digital terrain and elevation models) and derived metrics (e.g., RMS, std, Hurst, CPR) and perform statistical analyses (e.g., PCA, outliers, correlation matrices). Such tools are being developed and tested by the Resource Exploration and Science of our Cosmic Environment (RESOURCE) team, a node of NASA’s Solar System Exploration Research Virtual Institute (SSERVI), and are an excellent example of the powerful synergies of human and robotic ground assets critical in the return of humans to the Moon.

Ariel N. Deutsch↗

CaloriSMART: Small-scale test-stand for rapid evaluation of active magnetic regenerator performance

We report operation of a device designed specifically for rapid experimental evaluation of performance of magnetocaloric materials in different magnetic fields using a compact active magnetic regenerator bed with a total volume of approximately 5 mL. Other features of the system include digital control of the rotating-permanent-magnet field source and custom dual-opposed syringe pump that enable precise tuning and coupling of the flow profile and the magnetic field profile. Performance of the device is demonstrated for flow volumes between 1 and 4 mL (utilization from 0.48 to 1.9), maximum magnetic fields of 1.13 and 1.45 T, and applied cooling powers from 0 to 20 W at frequencies from 0.5 to 4 Hz. A regenerator comprised of 25 g of 200 µm spherical Gd powder reached temperature spans of 19.3 K under no applied cooling load and 2.6 K under the maximum applied cooling load of 20 W. The device also achieves a very high specific exergetic cooling power of 73 W L -1 T -1 . Results obtained at two different maximum magnetic fields in the same device suggest a powerful new scaling for regenerator performance: the exergetic power quotient. The exergetic power quotient shows a simple scaling of device cooling performance with the amount of active material and the magnetic field strength. This suggests results from a small device correlate to expected performance of a larger regenerator, making the exergetic power quotient a well-suited parameter for evaluating functionality of active magnetic regenerators employing new magnetocaloric materials.

47 OTHER INSTRUMENTATION↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of a Proton Bunch Phase Monitor for Range Verification in Proton Therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and is directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a bunch phase monitor can be performed. A first prototype of bunch phase monitor was tested at GSI Darmstadt, where measurements of the energy correlation profile of the ion bunches were performed. At the ELBE accelerator at Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Onco Ray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗