At least 145 records · Page 8

DieselGen.jl

SAND2026-22947O DieselGen.jl is a Julia tool for diesel-engine generator sizing and performance simulation. It provides a standalone implementation of FASTSim-style diesel fuel-converter behavior with differentiable efficiency and fuel-consumption calculations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

Robust Output Feedback Control Design for Inertia Emulation by Wind Turbine Generators

Wind generation has gained widespread use as a renewable energy source. Most wind turbines and other renewables connected to the grid through converters result in a reduction in the natural inertial response to grid frequency changes. The doubly-fed induction generator (DFIG) can be controlled to compensate for this reduction and, in fact, provide faster response than traditional synchronous machines. This paper proposes to design observer based output feedback linear quadratic regulator (LQR) and H control laws to realize the inertia emulation function and deliver fast frequency support. Furthermore, the aim is to track the reference speed by a diesel synchronous generator (DSG) in order to reach the desired inertia. The control signal is computed based on a reduced order model using the balanced truncation technique. A comparison with selective modal analysis (SMA) and balanced truncation model reduction techniques is presented. Comprehensive results show the effective emulation of synthetic inertia by implementing the control laws on a nonlinear three- phase diesel-wind system. The proposed technique is analyzed for different short circuit ratio (SCR) scenarios.

17 WIND ENERGY↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Behind-the-Meter Solar-Plus-Storage Program Design: With Considerations for India

Indian consumers have been deploying behind-the-meter generation (predominantly diesel backup, and, more recently, photovoltaic) and storage systems (predominantly lead-acid and other kinds of batteries as uninterrupted power supplies) by the millions for decades) to address reliability issues within the Indian power system. The same energy storage systems could provide additional services to the consumer and distribution companies if properly regulated and designed from the outset to be grid interactive. Grid-connected distributed solar PV (DPV), or rooftop solar, has also seen wide deployment in India and features prominently in the Government of India’s plans for a transition to clean, reliable, and affordable energy for all. At the same time, many utilities and state governments, as well as the central government in India are currently funding-constrained for both operational and future capital expenditures in the power sector, and some perceive customer-sited resources as exacerbating existing financial challenges. In that context, behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a potentially unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system in India. This report aims to offer a comprehensive, evidence-based approach to designing customer programs based on experience in the United States that can help regulators, utilities, and policymakers in India manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV.

14 SOLAR ENERGY↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

Comparative life cycle assessment of remote potable water supply for the Department of Defense

The Department of Defense (DOD) and other agencies, including relief organizations, require potable water for remote missions around the globe. As part of recent initiative by the U.S. Federal government through Executive Order 14057, the DOD has been instructed to investigate the sustainability of operations and practices within the context of climate change. One such practice that needs to be addressed is the procurement of potable water, an essential requirement of any remote mission or location. Currently, there are three primary means of procuring potable water at remote locations: bottled water, on-site purification, or tie-in to existing, local infrastructure. The first two operations are often considered the most secure options, but have sustainability concerns. The purpose of this study is to compare the environmental impacts of bottled water procurement versus on-site treatment via a mobile Reverse Osmosis Water Purification Unit (ROWPU), which uses multiple levels of filtration to make potable water from a local source. A cradle-to-gate assessment was developed for both systems to compare different options for potable water supply. An in person inventory was paired with data taken from the Ecoinvent 3.8 database to directly compare the two systems. The two systems are compared on a 5-year timeline to analyze the environmental impact of repeated bottled water transport versus diesel generator-fueled on-site treatment. Across all impact categories, the results indicate that high energy costs of the reverse osmosis process have significantly less impact on the environment than the repetitive transport and procurement of bottled water. The results of the study have important implications for advancing sustainable operations for remote communities or temporary settlements.

54 ENVIRONMENTAL SCIENCES↗

Supercritical water co-liquefaction of LLDPE and PP into oil: properties and synergy

The major plastic wastes are always mixtures, which are difficult to separate to treat in practice. Because of some possible cross-reactions, the degradation behaviors of plastics could not be mathematically represented by a simple addition of each polymer according to their proportions. This work examines supercritical water (scH 2 O) to liquefy poly-ethylene and poly-propylene mixtures into an oil with special interest in the oil quality and positive effect. Additionally, linear low-density polyethylene (LLDPE) and polypropylene (PP) were chosen as parent materials because of their high proportions in plastic wastes. The results show that a high conversion rate of around 99.75% was achieved with as high as 90.7 wt% oil yield without additional catalysts or hydrogen. The scH 2 O co-liquefaction of the LLDPE/PP mixture was different from that of the single polymer along with an improvement in the oil yield. Cyclic hydrocarbon ( i.e. , cyclic) generation was promoted while the production of paraffins was hindered in scH 2 O co-liquefaction using a mixture of LLDPE/PP. TGA reveals that the scH 2 O co-liquefaction of LLDPE/PP mixtures generated more diesel and lubricant oils and less gasoline and (jet fuel + light diesel) oils, thus slightly lowering the oil quality. Overall, the supercritical fluid technology was a powerful and promising means to liquefy mixed plastic wastes into oil at a high conversion rate free of catalysts or hydrogen.

42 ENGINEERING↗

Valuation of Distributed Wind in an Isolated System

Remote communities are increasingly adopting renewable energy, such as wind, as they transition away from diesel energy generation. It is important to understand the benefits and costs of wind energy to isolated systems so that decision-makers can optimize their choices in these communities. There are few examples of valuation of wind energy as a distributed resource and numerous differences in valuation approaches, especially in the inclusion of environmental and economic impacts. We apply a distributed wind valuation framework to calculate the benefits and costs of wind in St. Mary’s, Alaska, to the local electric cooperative and to society, finding that the project does not have a favorable benefit-to-cost ratio unless societal benefits are included, in which case the benefit-to-cost ratio is nearly double. Government funding is important to reducing the initial capital expenditures of this wind project and will likely be the case for projects with similar characteristics. Additional fuel savings benefits are potentially possible for this project through technological additions such as energy storage and advanced controls.

17 WIND ENERGY↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

Bethel Wind Energy Construction Project. Final report

Final report for the Bethel (Alaska) Wind Construction project. Under this project, Alaska Village Electric Cooperative, Inc. (AVEC) constructed and commissioned one new 900 kW-capacity wind turbine at a site in Bethel about 3.3 miles NE of the diesel-fired prime power plant. The wind generator’s output will augment the prime source generation provided by the diesel-powered generators.

17 WIND ENERGY↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Assessment Framework of Marine Hydrokinetic Technologies for Microgrid Applications

Communities in Alaska that are not connected to a regional grid (referred to hereafter as grid-islanded Alaskan communities) rely heavily on stand-alone generators with imported diesel fuel as the primary source of energy. Several of these grid-islanded Alaskan communities have the potential to harness significant wave, tidal, and hydrokinetic power; many also have hydropower or wind potential that could complement these resources. The implementation of marine and hydrokinetic energy focused microgrids in these communities would diversify their energy profiles, with the potential in many communities to keep costs flat while reducing dependance on diesel. This would enhance resilience and reduce environmental impacts. This seedling proposal will systematically identify grid-islanded coastal communities in Alaska with wave, tidal, and hydrokinetic energy potential to add fuel diversity to generation, applying microgrid integration methods and strategies that will meet the community’s needs. This proposal is in partnership with the Alaska Center for Energy and Power (ACEP) and XENDEE Corporation who bring extensive expertise in Alaskan communities and microgrid technoeconomic assessment, respectively. This project will deliver: (1) a database of grid-islanded communities that are candidates for MHK based microgrids, (2) an assessment of possible microgrid integration methods and strategies related to tidal, wave, and hydrokinetic technologies, and (3) a MHK development plan for the XENDEE Microgrid design platform and planning tool that can serve these grid-islanded communities and project developers. In the final stage, the planning tool will allow for the comprehensive comparison between diesel based and MHK based renewable generation.

16 TIDAL AND WAVE POWER↗

Pitka's Point/St. Mary's Wind Energy Construction Project. Final report

This is the final report for the St. Mary’s/Pitka’s Point Wind Construction Project. Under the project Alaska Village Electric Cooperative, Inc. (AVEC) constructed and commissioned one new 900 kW-capacity wind turbine at a site in Pitka’s Point about 4 miles from the diesel-fired prime power plant in St. Mary’s. The main objective of this project is to generate electric power from a renewable resource in an effort to reduce the local dependency on fuel oil as the sole source of electric power generation. The wind generator’s output augments the prime source generation provided by the diesel-powered generators.

17 WIND ENERGY↗

Quantifying Impacts of Renewable Electricity Deployment on Air Quality and Human Health in Southeast Asia Based on Aims III Scenarios

Exposure to outdoor air pollution is the largest environmental risk factor for death and disease worldwide, associated with millions of cases of excess deaths (mortality) each year. Although there are many pollutants in the air that affect our health, the most important class of pollutants is fine particulate matter, PM 2.5 , which are airborne particles of diameter ≤2.5 micrometers (µm). These particles are small enough to deposit deep in the respiratory system where they can then enter the bloodstream, traveling and causing damage to other bodily systems. Exposure to outdoor (ambient) PM 2.5 has been found to be the most important environmental risk factor for mortality in Southeast Asia, associated with 130,000 - 320,000 excess deaths in Association of Southeast Asian Nations (ASEAN) member countries in 2019. Southeast Asia, especially its mega-cities, but also other areas, has some of the worst air quality in the world. Almost all human activity emits air pollutants. Fine particulate matter is both directly emitted and formed in the atmosphere through chemical reactions, the latter of which requires modeling to predict. Power generation is one of the major sources of air pollutants that lead to elevated concentrations of fine particulate matter, including in Southeast Asia. Fossil fuel combustion for power generation, especially coal but also diesel, is the main source of air pollutant emissions from power generation. While natural gas burns cleaner than coal or diesel, in the quantities combusted for power generation in Southeast Asia, it is also a significant emitter. This study augments the ASEAN Interconnection Masterplan Study III (AIMS III) by quantifying changes to air quality and human health that result from its renewable integration and transmission interconnection scenarios. Performing this analysis requires translation of the changes in projected generation from different power sector fuel sources in the AIMS III scenarios to changes in air pollutant emissions, developing what's known as an emissions inventory for each scenario and year evaluated. We then use for the first time a new global, reduced-complexity air quality model to transform the changes in emissions to changes in air pollutant concentration of the deadliest air pollutant for human health, fine particulate matter (or PM 2.5 ). The air quality model, Global InMAP, then utilizes the location of human population in ASEAN countries to calculate exposure to PM 2.5 concentration changes and translates that to estimates of excess mortality attributable to the AIMS III scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Market Opportunities for Deployable Wind Systems for Defense and Disaster Response

This report is the first public deliverable from the Defense and Disaster Deployable Turbine project, funded through the distributed wind portfolio of the U.S. Department of Energy Wind Energy Technologies Office. The objective of the project is to explore the opportunity for deployable turbine technologies to meet the operational energy needs of the U.S. military and global disaster response efforts. This report provides a market assessment that was conducted over a year using public reports, presentations at topical conferences, and direct stakeholder engagement interviews with both military and industry representatives. It begins with the high- level operational energy strategy of the Department of Defense that provides the context for alternatives to diesel fuel to meet energy needs. The report then provides an estimate of the energy use of the military in missions where a deployable turbine could potentially serve as an alternative to the baseline use of diesel fuel in generators to provide electricity in remote locations. An overview of domestic and international disaster response is provided with a focus on the role of the military in providing energy to those events. Finally, the report summarizes the technical considerations that would enable a deployable turbine to meet military and disaster response energy needs including the global wind resource, the technical design of the turbine, and the operational constraints of various military missions.

17 WIND ENERGY↗

Recommendations for an Applicant to Calculate Activity Data for Greenhouse Gases Estimates

In 2009, the U.S. Nuclear Regulatory Commission (NRC) directed the NRC staff to address climate change issues and consider the impacts of the emissions of carbon dioxide (CO 2 ) and other greenhouse gases (GHGs) in its environmental reviews for major licensing actions (NRC 2009b). To implement this direction from the Commission, the staff issued guidance in 2011 and updated guidance in 2014 in Attachment 1 to Interim Staff Guidance COL/ESP-ISG-026 (NRC 2011; NRC 2014). This guidance provides a simpler method than the method described in RG 4.2 Rev. 3, that an applicant can use to meet the plant parameter envelope (PPE) value from the Generic Environmental Impact Statement for Licensing of New Nuclear Reactors (NR GEIS). NRC staff estimated the 97-year lifecycle GHG emissions from a reference 1000 megawatt electrical (MWe) light-water reactor (LWR) for various activities associated with construction, operation (including uranium fuel cycle), and decommissioning of nuclear power plants and presented the results in Appendix H of the NR GEIS. Appendix H of the NR GEIS includes estimates of direct emissions from construction equipment and emergency diesel engines in a nuclear facility and indirect emissions from workforce vehicular traffic, fuel transportation and the uranium fuel cycle. The NR GEIS Section 3.3 extended the estimates in Appendix H for the installation of two 1000 MWe nuclear reactors on the same site. Scaling factors were used to extrapolate the GHG emissions of a reference 1000 MWe reactor to a two-unit nuclear reactor plant (each reactor unit generating 1000 MWe). GHG emission estimates for building, operation, decommissioning and safe storage (SAFSTOR) for a two-unit nuclear reactor plant would be based on the plant’s physical size, and therefore estimates for these source categories were assumed to be twice the value of the reference 1000 MWe reactor. However, GHG emissions from the fuel cycle (including fuel transportation) were scaled upward by a factor of 3, based on plant efficiencies greater than the 80 percent assumption in Appendix H. Table 1 below shows the PPE emissions for two 1000 MWe nuclear reactors as provided in NR GEIS. The total GHG emissions for two 1000 MWe reactors were calculated as 2,534,000 metric tons (MT) of CO 2 equivalent (CO 2 (e)) based on a 97 year GHG life cycle period. The GHG emissions lifetime of 97 years for a reference nuclear reactor includes a 7-year building phase, 40 years of operation, 10 years of active decommissioning, and 40 years of SAFSTOR operations (NRC 2024). Construction equipment and vehicular traffic from workers commute would contribute to the GHG emissions during a 7-year building phase. Uranium fuel cycle, vehicular traffic, fuel and waste transportation, and testing of standby diesel generators would contribute to GHG emissions during the 40-year operations phase. While NRC’s regulations allow up to 60 years of reactor facility decommissioning, Appendix H estimated that most of the GHGs would occur over an estimated 10-year period during which to the licensee would engage in significant demolition and earth-moving activities, as discussed in Supplement 1 to NUREG-0586 (NRC 2002). Vehicular traffic by the workforce during a 40-year SAFSTOR period would additionally contribute GHG emissions. The carbon footprint for a 40-year SAFSTOR period was separately analyzed from the decommissioning activities as provided in Table YYYY-2 of the staff issued guidance in 2011 (NRC 2011).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of thermal processing and properties of 422 martensitic stainless steel for replacement of 4140 steel in diesel engine pistons

The thermal and mechanical properties of martensitic stainless steel 422 were evaluated for suitability as a drop-in replacement for 4140 steel in next generation heavy-duty diesel engine (HDDE) pistons. The time and temperature of the austenitization and tempering steps were studied to achieve optimum materials performance in piston applications, including the balance of thermal and mechanical properties and resistance to long-term thermal aging. Reducing the tempering temperature from 700 to 600 °C caused a substantial increase in elevated temperature strength from 25 to 600 °C, but had no significant influence on thermal conductivity, suggesting that thermal conductivity in 422 is dominated largely by composition and distribution of alloying elements and mostly independent of the sub-grain structure size and precipitate size. Compared to the current HDDE piston alloy 4140, 422 exhibits substantially higher elevated temperature strength and lower thermal conductivity, the latter which will cause 422 to operate at higher temperatures in pistons, possibly requiring a piston redesign to take advantage of the improved high temperature strength of 422. Piston material selection and alloy design strategies with potential to mitigate some of the shortcomings of martensitic stainless steels, such as 422, as drop-in replacements are discussed.