Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector and experiment monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Deuteron-induced reactions on natural Zr from threshold to 50 MeV: production of 86g Y

Two stacks of thin Zr foils were irradiated with 30 and 50 MeV deuterons, respectively, using the Lawrence Berkeley National Laboratory 88-Inch Cyclotron, and 19 excitation functions for nat Zr(d,x) reactions were measured over a beam energy range of 6.3–47.64 MeV, where the independent cross sections for nat Zr(d,x) 88 Nb and nat Zr(d,x) 86m,g Y were measured for the first time. The well-characterized nat Fe(d,x) 56 Co, nat Ni(d,x) 56 Co, nat Ni(d,x) 58 Co, nat Ni(d,x) 61 Cu, nat Ti(d,x) 46 Sc and nat Ti(d,x) 48 V monitor reactions were used to determine the deuteron beam current throughout the stacks. All cross sections were determined using High Purity Germanium (HPGe) detector γ-ray spectroscopy. A variance minimization technique was employed to simultaneously constrain the deuteron beam currents with multiple monitor reactions, thus reducing systematic uncertainties. An additional 16 channels are reported for reactions on the nickel, titanium, and iron monitor foils, leading to a total of 35 excitation functions, with seven reaction channels reported for the first time in this work. The measured excitation functions are compared to calculations provided by the reaction modeling codes TALYS – 2.0, ALICE – 2020, CoH – 3.5.3 and EMPIRE – 3.2.3, as well as the TENDL – 2023 data library. The degree of agreement between theory and experiments is discussed. The possible production of the important PET radionuclide 86g Y via the nat Zr(d,x) route was critically examined. The physical yields for nat Zr(d,x) 86 Y and other yttrium isotopes produced were calculated and compared to other production pathways. Due to high-level of associated radionuclide impurities, this route cannot deliver 86g Y suitable for medical applications.

86gY↗

The SAND detector for the DUNE experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation project aiming to study several neutrino properties. It will feature two experimental setups: a near detector that will be installed at Fermilab, in proximity of the neutrino-production point, and a far detector at a distance of 1300 km and 1500 m underground, at the SURF laboratory. The DUNE design and configuration will allow the study of neutrino oscillation, astrophysical neutrinos, and beyond standard model physics. The near detector complex foresees three detectors to be installed. Among these, the System for on-Axis Neutrino Detection (SAND) will serve as on-axis beam monitor, reduce the systematic uncertainties for the oscillation analysis, and search for physics beyond the standard model. SAND will be composed of three sub-detectors, surrounded by a 0.6 T superconducting magnet. The outermost detector will be a lead/scintillating-fiber electromagnetic calorimeter while the inner volume will include a 1-ton liquid argon active target placed upstream followed by a target tracker system. The SAND detector and its goals will be shown in this poster.

Alemanno, Francesca [Salento U.; INFN, Lecce]↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

Slow control and data acquisition development in the Mu2e experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far.Mu2e’s Trigger and Data Acquisition System (TDAQ) uses {\it otsdaq} solution. Developed at Fermilab, {\it otsdaq} uses the {\it artdaq} DAQ framework and {\it art} analysis framework, for event transfer, filtering, and processing.{\it otsdaq} is an online DAQ software suite with a focus on flexibility and scalability, and provides a multi-user interface accessible through a web browser.A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) open source Platform. The DCS System has also been integrated into {\it otsdaq}, providing a GUI multi-user, web-based control, and monitoring dashboard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Luminosity measurement for lead-lead collisions at $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV in 2015 and 2018 at CMS

Measurements of the luminosity delivered to the CMS experiment during the lead-lead data-taking periods in 2015 and 2018 are presented for the first time. The collisions were recorded at a nucleon-nucleon center-of-mass energy of 5.02 TeV; the 2018 data sample is three times larger than the 2015 data sample. Three subdetectors are used: the pixel luminosity telescope, the forward hadron calorimeters, and the fast beam conditions monitor. The absolute luminosity calibration is determined using the van der Meer technique that relies on transverse beam separation scans. The dominant sources of uncertainty are the transverse factorizability of the bunch density profiles and, in 2015, the difference between the results obtained using various detectors. The total uncertainty in the integrated luminosity, including the stability of the calibrated subdetector response over time, amounts to 3.0% for 2015, 1.7% for 2018, and 1.6% for the combined data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the free neutron lifetime in a magneto-gravitational trap with in situ detection

Here, in this study, we publish three years of data from the UCNτ experiment performed at the Los Alamos Ultracold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We previously reported a value from our 2017–2018 data for the neutron lifetime of 877.75 ± 0.28 (statistical) +0.22–0.16 (systematic) s. We have collected an additional three years of data reported here for the first time. When all the data from UCNτ are averaged for 2017, 2018, 2020, 2021, and 2022, we report an updated value for the lifetime of 877.83 ± 0.22 (statistical)+0.20–0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on residual gas, and employed four different UCN detector geometries both to reduce the correction required for rate dependence and to explore potential contributions due to phase space evolution.

Cabibbo-Kobayashi-Maskawa matrix↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SAND - System for on-Axis Neutrino Detection - in the DUNE Near Detector Complex

The DUNE experiment aims to precisely measure the long baseline neutrino oscillation parameters. The DUNE Far Detector consists of four liquid argon time-projection chambers (total LAr mass of 17 kton for each cryostat), that will be installed at the Sanford Underground Research Facility (SURF) in South Dakota, 1300 km from the proton beam target. The Near Detector complex, located at Fermilab, is fundamental for limiting the systematic uncertainties, due to the neutrino/antineutrino flux and to the cross-section. It comprises three complementary detectors: ND-Lar, ND-Gar and SAND (System for on-Axis Neutrino Detection). ND-Lar and ND-Gar can move off-axis, while SAND is the only detector permanently on-axis, whose primary goal is to monitor the beam and to measure the flux. In this talk, the SAND design and the expected performances will be described together with its role within the Near Detector complex for the DUNE physics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intersubband Relaxation in CdSe Colloidal Quantum Wells

The dynamics of intersubband relaxation are critical to quantum well technologies such as quantum cascade lasers and quantum well infrared photodetectors. In this work, intersubband relaxation in CdSe colloidal quantum wells, or nanoplatelets, is studied via pump-push-probe transient spectroscopy. An initial interband pump pulse is followed by a secondary infrared push excitation, resonant with intersubband absorption, which promotes electrons from the first conduction band of the quantum well to the second conduction band. A probe pulse monitors subsequent electron cooling to the band edge of the quantum well. Using this technique, intersubband relaxation is studied as a function of critical variables such as colloidal quantum well size and thickness, surface ligand chemistry, temperature, and excitation pulse intensity. Larger quantum well sizes, judicious selection of surface ligand chemistry (e.g., thiolates), low temperatures, and elevated push pulse fluences slow intersubband relaxation. However, compared to resonant intraband relaxation in colloidal quantum dots (up to hundreds of picoseconds), intersubband relaxation in colloidal quantum wells is rapid (<1 ps) under all examined conditions. These experiments indicate that rapid relaxation is driven by both LO phonon and surface scattering. The short time scale of relaxation observed in these materials may hinder intersubband technologies such as mid-infrared detectors, although such rapid relaxation may prove valuable in optical switching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Millimeter-wave, Gamma-Ray, and Optical Monitoring of the Blazar PKS 2326-502 during a Flaring State

Including millimeter-wave data in multiwavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence millimeter-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these millimeter-wave light curves to those at other wavelengths, in particular γ-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now millimeter-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first 2 yr of this monitoring, and we present a search for evidence of correlated variability between millimeter-wave, optical R-band, and γ-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multiwavelength studies with facilities such as Vera C. Rubin Observatories Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

Slow control and data acquisition systems in the Mu2e experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinolessconversion of a muon into an electron in the field of an aluminum nucleus with a sensitivityimprovement by a factor of 10,000 over existing limits. The Mu2e Trigger and Data AcquisitionSystem (TDAQ) usesotsdaqas the online Data Acquisition System (DAQ) solution. Developed atFermilab,otsdaqintegrates both theartdaqDAQ and theartanalysis frameworks for event transfer,filtering, and processing.otsdaqis an online DAQ software suite with a focus on flexibility andscalability and provides a multi-user, web-based, interface accessible through a web browser. Thedata stream from the detector subsystems is read by a software filter algorithm that selects eventswhich are combined with the data flux coming from a Cosmic Ray Veto System. The DetectorControl System (DCS) has been developed using the Experimental Physics and Industrial ControlSystem (EPICS) open source platform for monitoring, controlling, alarming, and archiving. TheDCS System has been integrated intootsdaq. A prototype of the TDAQ and the DCS systems hasbeen built at Fermilab’s Feynman Computing Center. In this paper, we report on the progress ofthe integration of this prototype in the onlineotsdaqsoftware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online DAQ and slow control interface for the Mu2e experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinolessconversion of a muon into an electron in the field of an aluminum nucleus with a sensitivityimprovement by a factor of 10,000 over existing limits. The Mu2e Trigger and Data AcquisitionSystem (TDAQ) usesotsdaqas the online Data Acquisition System (DAQ) solution. Developed atFermilab,otsdaqintegrates both theartdaqDAQ and theartanalysis frameworks for event transfer,filtering, and processing.otsdaqis an online DAQ software suite with a focus on flexibility andscalability and provides a multi-user, web-based, interface accessible through a web browser. Thedata stream from the detector subsystems is read by a software filter algorithm that selects eventswhich are combined with the data flux coming from a Cosmic Ray Veto System. The DetectorControl System (DCS) has been developed using the Experimental Physics and Industrial ControlSystem (EPICS) open source platform for monitoring, controlling, alarming, and archiving. TheDCS System has been integrated intootsdaq. A prototype of the TDAQ and the DCS systems hasbeen built at Fermilab’s Feynman Computing Center. In this paper, we report on the progress ofthe integration of this prototype in the onlineotsdaqsoftware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗