Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The application of laser Rayleigh scattering to gas density measurements in hypersonic helium flows

Measurements of the mean static free-stream gas density have been made in two Langley Research Center helium facilities, the 3-inch leg of the high-Reynolds-number helium complex and the 22-inch hypersonic helium tunnel. Rayleigh scattering of a CW argon ion laser beam at 514.5 nm provided the basic physical mechanism. The behavior of the scattered signal was linear, confirmed by a preliminary laboratory study. That study also revealed the need to introduce baffles to reduce stray light. A relatively simple optical system and associated photon-counting electronics were utilized to obtain data for densities from 10 to the 23rd to 10 to the 25th per cu m. The major purpose, to confirm the applicability of this technique in the hypersonic helium flow, was accomplished.

Hoppe, J. C.↗

Improved resolution atmospheric density measurements based on simulations

Simulated C band radar data of very structured atmospheric density profiles were analyzed using the standard HIROBIN program used with falling sphere data. Results show that HIROBIN can only resolve 2 km vertical waves up to 50 to 55 km, and 5 km waves up to 65 km. Above 65 km, only waves longer than 5 km can be resolved. Shorter filters can be used to improve vertical resolution, but it is concluded that HIROBIN can no longer be considered operational unless experienced personnel who fully understand the program are available for consultation.

Schmidlin, F. J.↗

Cluster electric current density measurements within a magnetic flux rope in the plasma sheet

On August 22, 2001 all 4 Cluster spacecraft nearly simultaneously penetrated a magnetic flux rope in the tail. The flux rope encounter took place in the central plasma sheet, Beta(sub i) approx. 1-2, near the leading edge of a bursty bulk flow. The "time-of-flight" of the flux rope across the 4 spacecraft yielded V(sub x) approx. 700 km/s and a diameter of approx.1 R(sub e). The speed at which the flux rope moved over the spacecraft is in close agreement with the Cluster plasma measurements. The magnetic field profiles measured at each spacecraft were first modeled separately using the Lepping-Burlaga force-free flux rope model. The results indicated that the center of the flux rope passed northward (above) s/c 3, but southward (below) of s/c 1, 2 and 4. The peak electric currents along the central axis of the flux rope predicted by these single-s/c models were approx.15-19 nA/sq m. The 4-spacecraft Cluster magnetic field measurements provide a second means to determine the electric current density without any assumption regarding flux rope structure. The current profile determined using the curlometer technique was qualitatively similar to those determined by modeling the individual spacecraft magnetic field observations and yielded a peak current density of 17 nA/m2 near the central axis of the rope. However, the curlometer results also showed that the flux rope was not force-free with the component of the current density perpendicular to the magnetic field exceeding the parallel component over the forward half of the rope, perhaps due to the pressure gradients generated by the collision of the BBF with the inner magnetosphere. Hence, while the single-spacecraft models are very successful in fitting flux rope magnetic field and current variations, they do not provide a stringent test of the force-free condition.

Slavin, J. A.↗

Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma

We report a comparison of inferred electron density (n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature (T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He + and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The O(3P) and N(4S) density measurement at 225 km by ultraviolet absorption and fluorescence in the Apollo-Soyuz test project

The densities of O(3P) and N(4S) at 225 km were determined during the Apollo Soyuz Test Project by a resonance absorption/fluorescence technique in which OI and NI line radiation produced and collimated on board the Apollo was reflected from the Soyuz back to the Apollo for spectral analysis. The two spacecraft maneuvered so that a range of observation angles of plus or minus 15 deg with respect to the normal to the orbital velocity vector was scanned. The measurements were made at night on two consecutive orbits at spacecraft separations of 150 and 500 m. The resulting relative counting rates as function of observation angle were compared to calculated values to determine the oxygen value. This value agrees with mass spectrometric measurements made under similar conditions. The nitrogen value is in good agreement with other measurements and suggests a smaller diurnal variation than is predicted by present models.

Kaufman, F.↗

Vacuum energy density measured from cosmological data

Within the ΛCDM cosmological model, the absolute value of Einstein's cosmological constant Λ, sometimes expressed as the gravitating mass-energy density ρΛ of the physical vacuum, is a fundamental constant of nature, whose accurate measurement plays a central role in testing some proposed theories of quantum gravity. Several combinations of currently public cosmological data and an assumed flat ΛCDM cosmological model are used here to make a joint Bayesian inference on the combination of conventional parameters Ω Λ h 2 that corresponds to the absolute physical density ρΛ. In physical units, we obtain ρ Λ = (60.3 ± 1.3)× 10 -31 g/cm 3 , the most accurate constraint to date, with an absolute calibration of cosmological measurements based on CMB temperature. Significantly different values are obtained with calibrations that use a local distance scale, mainly connected to systematic differences in the value of the Hubble constant. Furthermore, it is suggested that future comprehensive cosmological parameter studies assuming the ΛCDM model include constraints on the vacuum density.

79 ASTRONOMY AND ASTROPHYSICS↗

Velocity, Temperature and Density Measurements in Supersonic Jets

Prediction of the flow field properties in supersonic jets using computational fluid dynamics (CFD) codes is challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are substantial. A benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Three different convergent-divergent nozzles were investigated with exit Mach numbers of: 1.36, 1.63 and 2.0 at their perfectly expanded conditions. The conditions of the jet were set to obtain a temperature difference of zero between the jet core and the ambient air, and then the temperature difference was progressively increased, at the same jet Mach number. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering spectroscopy (SRS), Background Oriented Schlieren (BOS) and probe-based measurements were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms gas temperatures and densities in both hot and cold supersonic jet flows. The non-intrusive flow measurements are compared both against probe measurements and against standard Reynolds averaged Navier-Stokes (RANS) predictions of the supersonic jet flow properties.

Raman Spectroscopy↗

Absolute ion density measurements in the afterglow of a radiofrequency atmospheric pressure plasma jet

Atmospheric pressure plasma jets (APPJs) can enable large fluxes of reactive species impinging on treated substrates in many applications. The relative importance of ionic versus neutral reactive species fluxes produced by APPJs is to date mainly deduced from modeling due to the challenge of measuring absolute ion densities/fluxes. In this study, a calibration was performed to determine the absolute densities of cold ions in the afterglow region of an RF-driven atmospheric pressure plasma jet (APPJ) in Ar + 1% O 2 by molecular beam mass spectrometry. Here, positive ion densities were found to be about 3-4 orders of magnitudes lower than the densities of the dominant reactive neutral species (O, O 2 (a 1 Δ g ), O 3 ) in the afterglow region of the APPJ at a distance larger than 2 mm from the visible plasma plume. The results illustrate the ability of molecular beam mass spectrometry to enable a quantitative evaluation of both neutral and ionic species in many applications using APPJs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of XCT for Matrix Density Measurement of Particle Fuel Forms

Particle fuel forms generally consist of a dispersion of fuel, such as tristructural isotropic (TRISO) particles, within a refractory matrix (e.g., graphite or silicon carbide). The density of matrix materials for particle fuel forms is of interest for modeling fuel form strength and thermal properties and may be specified as a quality control parameter, depending on reactor design. Some of the uncertainty associated with traditional, manual approaches can be eliminated by performing x-ray computed tomography (XCT) on the fuel forms and applying image processing methods to generate a precise count of the number of particles. This also removes the need to include determination of particle count within each individual fuel form during fabrication. Unfortunately, reconstruction artifacts from high-Z uranium-bearing kernels prevent accurate measurement of individual particle volumes using this approach, so the use of mean particle mass and volume are still necessary for computation of average fuel form matrix density. This method of using XCT to count particles in individual fuel form for determination of average matrix density was applied to three archived compacts from the Advanced Gas Reactor Fuel Development and Qualification (AGR)-1 campaign, four archived compacts with uranium carbide/uranium oxide (UCO) TRISO from the AGR-2 campaign, and three archived UO 2 -TRISO compacts from the AGR-2 campaign. The resulting density values were compared with those previously reported, showing slight changes due to uncertainties in the previously used number of particles in each of these cylindrical, graphite matrix compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Density measurements in an expanding flow using holographic interferometry

A nonequilibrium expansion of nitrogen through a 2-dimensional nozzle of a reflected shock tunnel is investigated with laser holography, time resolved pressure measurements and emission spectroscopy to characterize the flow field for vibrational relaxation measurements. A 2D computation is used to simulate the nozzle flow field. Synthetic holograms are generated using the computed density profiles and are compared with the experimental holograms. Also, using a quasi 1-D approximation, populations for each vibrational level are computed by (1) solving the master equations and (2) using the Landau-Teller formulation. Computational accuracy of both models is assessed against the experimental data.

Sharma, Surendra P.↗

Development of a Method for Local Electron Temperature and Density Measurements in the Divertor of the JET Tokamak

Plasma volume recombination in the divertor, a process in which charged particles recombine to neutral atoms, contributes to plasma detachment and hence cooling at the divertor target region. Detachment has been observed at JET and other tokamaks and is known to occur at low electron temperatures (T(sub e)<1 eV) and at high electron density (n(sub e)>10(exp 20)/m(exp 3)). The ability to measure such low temperatures is therefore of interest for modelling the divertor. In present work we report development of a new spectroscopic technique for investigation of local electron density (n(sub e)) and temperature (T,) in the outer divertor at JET.

Jupen, C.↗

LIF Density Measurement Calibration Using a Reference Cell

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. A pulsed UV laser was used to pump the ground state molybdenum at 345.64nm, and the non-resonant fluorescence at 550-nm was collected using a bandpass filter and a photomultiplier tube or intensified CCD array. The sensitivity of the fluorescence was evaluated to determine the limitations of the calibration technique. The suitability of the diagnostic calibration technique was assessed for application to ion engine erosion rate measurements.

Domonkos, Matthew T.↗

Extreme compression of planetary gases: High-accuracy pressure-density measurements of hydrogen-helium mixtures above fourfold compression

Hydrogen (H 2 ) and helium (He), the most abundant elements in the universe, pose a unique challenge in measuring the equation of state of the mixture, owing to their differing physical properties. There remains a need for data with high enough precision to discriminate between existing equation of state (EOS) mix models in order to understand the internal structure of gas-giant planets. Here, we have measured the EOS of precompressed H 2 - He mixtures at conditions directly relevant to the planetary interiors using hypervelocity gas guns and Sandia’s Z machine with less than 10% uncertainty in density, enabling validation of mixture models. We precompressed 50:50 molar mixtures of H 2 -He to 0.1–0.2 GPa and directly measured particle velocity (in gas-gun experiments) and shock velocities (in Z-machine experiments). To complement the experimental efforts, we also computed the Hugoniots of precompressed H 2 -He mixtures using density-functional-theory-based molecular dynamics. Furthermore, we observe approximately 3- to 4.3-fold density compression at pressures up to 44 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗