Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

Self-Sustainable IoT-Based Remote Sensing Powered by Energy Harvesting Using Stacked Piezoelectric Transducer and Thermoelectric Generator

We propose a self-powered remote multi-sensing system for traffic sensing which is powered by the collective energy harvested from the mechanical vibration of the road caused by the passing vehicles and from the temperature gradient between the asphalt of the road and the soil underneath. A stacked piezoelectric transducer converts mechanical vibrations into electrical energy and a thermoelectric generator harvests the thermal energy from the thermal gradient. Electrical energy signals from the stacked piezoelectric transducer and the thermoelectric generators are converted into usable DC power to recharge the battery using AC-DC and DC-DC converters working simultaneously. The multi-sensing system comprises an embedded system with a microcontroller that acquires data from the sensors and sends the sensory data to an IoT transceiver which transmits the data as RF packets to an ethernet gateway. The gateway converts the RF packets into Internet Protocol (IP) packets and sends them to a remote server. Laboratory and road-testing results showed over 98% sensory data accuracy with the system functioning solely powered by the energy harvested from the alternative energy sources. The successful maximum transmission distance obtained between the IoT, and the gateway was approximately 1 mile, which is a considerable transmission distance achieved in an urban environment. Successful operation of the self-powered multi-sensing system under both laboratory and road conditions contributes considerably to the fields of energy harvesting and self-powered remote sensing systems. The energy flow chart and efficiency for the steps in the system were found to be mechanical power from vehicles to the energy harvester of 0.25%, stacked PZT transducer efficiency was found to be 37%, and for the TEGs the efficiency is 11%. AC-to-DC and DC-to-DC converters’ efficiencies were found to be 90% and 11%. The wireless communication RF transceiver efficiency was found to be 62.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aggregate data‐driven dynamic modeling of active distribution networks with DERs for voltage stability studies

Abstract Electric distribution networks increasingly host distributed energy resources based on power electronic converter (PEC) toward active distribution networks (ADN). Despite advances in computational capabilities, electromagnetic transient models are limited in scalability because of their reliance on exact data about the distribution system and each of its components. Similarly, the use of the DER_A model, which is intended to examine the combined dynamic behavior of many DERs, is limited by the difficulty in parameterization. There is a need for improved dynamic models of DERs for use in large power system simulations for stability analysis. This paper proposes an aggregate model‐free, data‐driven approach for deriving a dynamic partitioned model (DPM) of ADNs. Detailed residential distribution feeders were first developed, including PEC‐based DERs and composite load models (CMLDs), from which the aggregated DPM was derived. The performance was evaluated through various case studies and validated against the detailed ADN model and state‐of‐the‐art DER_A model with CMLD. The data‐driven DPM achieved a of over 90%, accurately representing the aggregated dynamic behavior of ADNs. Furthermore, the DPM significantly accelerated the simulation process with a computational speedup of 68 times compared to the detailed ADN and a 3.5 times speedup compared to the DER_A CMLD model.

42 ENGINEERING↗

Demand Driven Energy Management for PIPO Auxiliary Power Supply Architecture

In this paper, a demand driven energy management (DDEM) technique is implemented on modular parallel input parallel output DC/DC auxiliary power supply (APS) structure. In this method, modules are brought in/out of the operation making them operate under high loading conditions, avoiding low efficiency under light load. Such a method finds its application in power conservative systems with variable load. Implementation of DDEM and the energy saved is shown using APS comprised of two 15W commercially off-the-shelf DC-DC modules, with 100–1000 VDC input and 24 V output voltage. Along with the DDEM, the lifetime of the power stage devices is controlled minimizing their junction temperature swing through control of cooling system. This control method uses digital twin as interface to virtualize the power devices loading operation/ health condition. Accordingly, no extra sensor or closed loop control required to measure the junction temperature of the devices or feedback the losses to the cooling flow.

Azadeh, Yalda↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

A Multistage Stochastic Transmission Expansion Algorithm for Wide-Area Planning under Uncertainty

The overall objective for this project was to develop and demonstrate a set of methods for solving the transmission investment problem for a large network considering many possible scenarios of future conditions and multiple decision points when investments can be made. Project sub-objectives achieved this goal through a succession of extending the methods to apply to problems with increasing complexity or additional features, including the number of decision points, whether generation and transmission are co-optimized, and whether AC or DC power flow is used. A transmission model was developed for the Western Electric Coordinating Council (WECC) region, the high-voltage transmission system that serves the western third of the continental U.S. Using a dataset provided by WECC and by researchers from John Hopkins University, we have validated and demonstrated the model and used it to compare the new method for solving multi-stage stochastic transmission planning to several state-of-the-art techniques. The project has resulted in several key outcomes and achievements: The covariance-based method for choosing a small set of hours to represent short-term variability has superior performance in terms of accuracy to existing methods, including K-means clustering and Importance Sampling; The combined partitioning method for long-term uncertainty with the nested clustering approach for choosing representative hours for each long-term group has superior accuracy for equivalent computational effort compared with existing methods; Using the partitioning/clustering method combined with Sample Average Approximation provides both statistical bounds on the quality of the solution and at the same time, a complete investment plan for all contingencies in the full uncertainty set; no existing methods can provide both at the same time; The method is demonstrated to work well for choosing both transmission and generation investments; A variant on the method allows for both scenario selection and simultaneous correction for the error from the DC power flow approximation to provide a tractable method for AC power flow-based transmission planning under uncertainty; The method applied to the WECC case study demonstrates the additional value to the system operator and the consumer of identifying flexible investment options in the near-term decisions. In particular, the case study exhibits significant option value in postponing some transmission additions that appear useful but in some long-term system states create new congestion problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of hybrid HVDC systems combining line communicated converter and voltage source converter

Hybrid HVDC system, which consists of the advantages of line commutated converter (LCC) and voltage source converter (VSC), is an emerging power transmission system. This paper presents a review of four LCC-VSC hybrid HVDC topologies. The first topology is the pole-hybrid HVDC system, in which the LCC and VSC form the positive- and negative-pole respectively. The second one is the terminal-hybrid HVDC system; in this topology one terminal adopts LCC and the other terminal adopts VSC. The series converter-hybrid HVDC system is the third topology wherein each terminal is formed by LCC and VSC in series. The fourth hybrid topology under consideration is a parallel converter-hybrid HVDC system with LCC and VSC connected in parallel in each terminal. Here, the main contribution of this paper is a comprehensive analysis and comparison of the four mentioned hybrid topologies in terms of PQ operating zone, power flow reversal method, and DC fault ride-through strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

Distributed Cooperative Control of Hybrid AC/DC Microgrid

This paper presents a distributed cooperative control-based power management algorithm for a hybrid AC/DC microgrid. The proposed algorithm for a hybrid microgrid system controls the power flow through the interface converter between the AC and DC microgrids. This algorithm allows power sharing between the distributed generators in the microgrid according to their power ratings. Moreover, it enables the fixed scheduled power delivery through the interface converters in both directions at different operating conditions while maintaining voltage regulation and improving the frequency profile. The effectiveness of the controller is confirmed by simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-cost connectors for inverters and converters and methods of manufacturing and using the same

In some embodiments, systems and methods for connector assembly for use with an AC or DC power interface of a power conversion device, such as a converter and an inverter, are provided. The connector assembly can include a circuit board, a power connector, and a pin. The power connector can have a base configured to be secured relative to the circuit board and define a first channel extending through the power connector along a first channel axis. The first pin can have a first pin body that extends along a first pin axis and a first connection element that extends along the first pin axis from the first pin body to a first terminal end that is skewed relative to the first pin axis.

Khaligh, Alireza↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Reliable Multi-Port Smart Inverter Modules for PV-Based Energy Systems

Generally, large electrolytic capacitors (E-caps) are required to decouple the double-line frequency power fluctuation inherent in all single-phase dc-ac or ac-dc converters. These E-caps pose the weak link in the photovoltaic (PV) inverter because they have poor reliability as a result of short life expectancy and higher equivalent series resistance (ESR) which leads to lower system efficiency. In this paper, multiport smart dual-inverter modules are proposed for residential PV inverter systems with balanced outputs to eliminate the requirement of large decoupling capacitors, thus leading to more reliable and highly efficient inverter modules. The balanced dual outputs are controlled in phase quadrature such that the double frequency current is completely eliminated. One phase supports the standalone residential loads, and the other phase interfaces with the grid, which is synchronized to the utility grid. Also, the proposed modular configuration is scalable to accommodate higher power rating by stacking and paralleling multiple modules. Simulation results for the dual-inverter modules rated for 1 kW each are presented to validate the proposed concept. Experimental results from a controller hardware-in-the-loop (CHIL) platform also verify its feasibility.

14 SOLAR ENERGY↗