Langley Wind Tunnel Data Quality Assurance-Check Standard Results

A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.

Hemsch, Michael J.↗

Assessment of SAGE Version 6.1 Ozone Data Quality

The SAGE-II V6.1 ozone retrievals are shown to be of better precision at all levels and to be much more accurate than previous retrievals in the lower stratosphere below 20 km altitude. A filtering procedure for removing anomalous ozone profiles associated with volcanic aerosol/cloud effects and other identified artifacts in V6.1 ozone is described. The agreement between SAGE and ozonesondes in the mean is shown to be approximately 10% down to the tropopause. Relative to the sondes SAGE tends to slightly overestimate ozone (less than 5%) between 15 and 20 km altitude, and systematically underestimates ozone in the troposphere by approximately 30% in the regions between 8 km altitude and 2 km below the tropopause. The precisions (random errors) of SAGE ozone retrievals above 25 km altitude are estimated to be 4% or better; they are a factor of ten worse below 16 km altitude. Linear trends in the differences between coincident SAGE and ozonesondes measurement are generally less than 0.3 %/year and not significantly different from zero in 95% confidence intervals. Compared to V5.96 retrievals, ozone trend differences between 20 and 50 km altitude are approximately 0. 1 %/year, below 20 km altitude the SAGE II trends are more positive by approximately 0.2 %/year. For the 1984-1999 period the SAGE-II shows a localized ozone loss of -0.4(+/- 0.25) %/year (2gigma) in the tropics at 20 km altitude. In the lower stratosphere between 16 and 22 km altitudes, the SAGE shows significant ozone losses in the mid-latitudes in both Hemispheres during the 1979-1999 periods. The ozone trends range from -0.24(+/- 0.18) to -0.77(+/- 0.46) (2sigma)%/year. However in the 1984-1999 period, the downward trends are smaller (-0.07 to - 0.25 %/year) in this altitude range, and the trends in the integrated column from 12 to 17 km altitude in mid-latitudes (35 deg - 60 deg) are not significantly different from zero (0.1 +?- 0.6 (2sigma)%/year). Averaged over the tropics (20 deg S to 20 deg N) the ozone column above 15 km altitude exhibit a trend of -0.12 +/- 0.08 (2sigma)%/year.

Wang, Hsiang J.↗

Software Facilitates Sharing of Water Quality Data Worldwide

John Freighery was an environmental engineer at Johnson Space Center when a new, simplified version of the coliform bacteria test was developed for astronaut use on the International Space Station. Through his New York City-based mWater Foundation, Freighery is using the test to help rural communities monitor their water supplies for contamination. The organization has also developed a mobile phone app to make the information publicly available.