Multiscale wireless sensor node for impedance-based SHM and low-frequency vibration data acquisition

This paper presents recent developments in an extremely compact, wireless impedance sensor node (WID3, Wireless Impedance Device) at Los Alamos National Laboratory for use in impedance-based structural health monitoring (SHM), Sensor diagnostics and low-frequency vibrational data acquisition. The current generation WID3 is equipped with an Analog Devices AD5933 impedance chip that can resolve measurements up to 100 kHz, a frequency range ideal for many SHM applications. An integrated set of multiplexers allows the end user to monitor seven piezoelectric sensors from a single sensor node. The WID3 combines on-board processing using an Atmega1281 microcontroller, data storage using flash memory, wireless communications capabilities, and a series of internal and external triggering options into a single package to realize a truly comprehensive, self-contained wireless active-sensor node for SHM applications. Furthermore, we recently extended the capability of this device by implementing low-frequency analog to digital and digital and analog converters so that the same device can measure structural vibration data. The WID3 requires less than 70 mW of power to operate, and it can operate in various wireless network paradigms. The performance of this miniaturized and portable device is compared to our previous results and its broader capabilities are demonstrated.

42 ENGINEERING↗

Lidar Report

This report provides an overview of the LiDAR acquisition methodology employed by Woolpert on the 2009 USDA - Savannah River LiDAR Site Project. LiDAR system parameters and flight and equipment information is also included. The LiDAR data acquisition was executed in ten sessions from February 21 through final reflights on March 2, 2009; using two Leica ALS50-II 150kHz Multi-pulse enabled LiDAR Systems. Specific details about the ALS50-II systems are included in Section 4 of this report.

60 APPLIED LIFE SCIENCES↗

A Data Science and Machine Learning Platform Supporting Large Particle Accelerator Control and Diagnostics Applications Final Report: SBIR Initial Phase II DE-SC0022583

The Machine Learning Data Platform (MLDP) is a product providing full-stack support for data science, Machine Learning, and Artificial Intelligence (ML/AI) applications at particle accelerator and large experimental physics facilities. It supports ML/AI applications from front-end, high-speed acquisition of heterogeneous, time-series data, through data archiving and management, to back-end analysis. The MLDP embodies a “data-science ready” platform for data analysis and ML/AI applications in diagnosis, modelling, control, and optimization of these facilities. It provides data scientists and applications a consistent, datacentric interface to archive data standardizing implementation and deployment of ML/AI algorithms to different operations configurations within the same facility, or between facilities. Being an open-source, public-domain project, the MLDP is intended for broadest possible impact by increasing accessibility and minimizing the required expertise for installation and operation. The MLDP can also be deployed at user facilities for experimental data collection, archiving, and analysis. It is capable of acquisition and archiving of heterogeneous data from experimental equipment (e.g., images, arrays, structures, etc.) along with system hardware configurations (e.g., scalars, tables), control system process variables, and any metadata required for provenance. Thus, the MLDP can manage experimental data through its entire lifecycle, from acquisition and archiving, through analysis and investigation, to release and final publication.

43 PARTICLE ACCELERATORS↗

Self-adaptive sampling rate data acquisition in JET's correlation reflectometer

Data acquisition systems with self-adaptive sampling rate capabilities have been proposed as a solution to reduce the shear amount of data collected in every discharge of present fusion devices. This paper discusses the design of such a system for its use in the KG8B correlation reflectometer at JET. The system, which is based on the ITMS platform, continuously adapts the sample rate during the acquisition depending on the signal bandwidth. Data are acquired continuously at the expected maximum sample rate and transferred to a memory buffer in the host processor. Thereafter the rest of the process is based on software. Data are read from the memory buffer in blocks and for each block an intelligent decimation algorithm is applied. The decimation algorithm determines the signal bandwidth for each block in order to choose the optimum sample rate for that block, and from there the decimation factor to be used. Memory buffers are used to adapt the throughput of the three main software modules (data acquisition, processing, and storage) following a typical producer-consumer architecture. The system optimizes the amount of data collected while maintaining the same information. Design issues are discussed and results of performance evaluation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of waviness in wind turbine blades using air coupled ultrasonics

Waviness in glass fiber reinforced composite is of great interest in composite research, since it results in the loss of stiffness. Several NDE techniques have been used previously to detect waviness. This work is concerned with waves normal to the plies in a composite. Air-coupled ultrasonics was used to detect waviness in thick composites used in the manufacturing of wind turbine blades. Composite samples with different wave aspect ratios were studied. Different wavy samples were characterized, and a three step process was developed to make sure the technique is field implementable. This gives us a better understanding of the effect of waviness in thick composites, and how it affects the life and performance of the composite.

42 ENGINEERING↗

Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hardware-Software Complex for Measurement of Energy and Angular Distributions of Charged Particles Formed in Nuclear Reactions

A hardware-software complex for measurement of energy and angular distributions of charged particles formed in nuclear reactions is presented. Hardware and software structures of the complex, the basic set of the modular nuclear-physical apparatus of a multichannel detecting system on the basis of ΔE–E telescopes of silicon detectors, and the hardware of experimental data collection, storage, and processing are presented and described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ceramic Seal.

Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Software Development for a CompactRIO-Based Wire Scanner Control and Data Acquisition SYstem

The Beam Diagnostics and Instrumentation Team at the Los Alamos Neutron Science Center is developing a wire scanner data acquisition and control system with a National Instrument's compactRIO at its core. For this application, the compactRIO controller not only requires programming the FPGA and RT computer internal to the compactRIO, but also requires programming a client computer and a touch panel display. This article will summarize the hardware interfaces and describe the software design approach utilized for programming and interfacing the four systems together in order to fulfill the design requirements and promote reliable interoperability.

42 ENGINEERING↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence Analysis

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaction System Design for NO 2 Oxidation of Used Nuclear Fuel for the FY17 Hot Test

A dry pretreatment process based on the oxidation of used nuclear fuel to convert it to a fine powder is being studied for the removal and capture of tritium and iodine before subsequent processing. The process converts oxide fuel into a fine powder at low temperature using NO 2 /O 2 mixtures. The form of the powder product can be selected to be U 3 O 8 , UO 3 , or a nitrate by adjusting the processing conditions. All the fundamental tenets of the process have been successfully demonstrated as a proof of principle, and many aspects have been corroborated multiple times at laboratory scale. The present thrust is to develop the process to a technology-readiness level sufficient to evaluate and estimate the cost of an engineering-scale implementation. A previous roadmap analysis of the implementation determined that the most desirable approach would be based on kilogram-scale experiments using real fuel in parallel with multi-kg testing of prototype systems using surrogate material. Following the planned approach, kilogram-scale experiments will be conducted in FY 2017. This report describes the primary reaction system designs and the equipment that has been fabricated. Details related to instrumentation, data acquisition, and controls have been previously reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rules and management of biomedical waste at Vivekananda Polyclinic: A case study

Hospitals and other healthcare establishments have a 'duty of care' for the environment and for public health, and have particular responsibilities in relation to the waste they produce (i.e., biomedical waste). Negligence, in terms of biomedical waste management, significantly contributes to polluting the environment, affects the health of human beings, and depletes natural and financial resources. In India, in view of the serious situation of biomedical waste management, the Ministry of Environment and Forests, within the Government of India, ratified the Biomedical Waste (Management and Handling) Rules, in July 1998. The present paper provides a brief description of the biomedical waste (Management and Handling) Rules 1998, and the current biomedical waste management practices in one of the premier healthcare establishments of Lucknow, the Vivekananda Polyclinic. The objective in undertaking this study was to analyse the biomedical waste management system, including policy, practice (i.e., storage, collection, transportation and disposal), and compliance with the standards prescribed under the regulatory framework. The analysis consisted of interviews with medical authorities, doctors, and paramedical staff involved in the management of the biomedical wastes in the Polyclinic. Other important stakeholders that were consulted and interviewed included environmental engineers (looking after the Biomedical Waste Cell) of the State Pollution Control Board, and randomly selected patients and visitors to the Polyclinic. A general survey of the facilities of the Polyclinic was undertaken to ascertain the efficacy of the implemented measures. The waste was quantified based on random samples collected from each ward. It was found that, although the Polyclinic in general abides by the prescribed regulations for the treatment and disposal of biomedical waste, there is a need to further build the capacity of the Polyclinic and its staff in terms of providing state-of-the-art facilities and on-going training in order to develop a model biomedical waste management system in the Polyclinic. There is also a need to create awareness among all other stakeholders about the importance of biomedical waste management and related regulations. Furthermore, healthcare waste management should go beyond data compilation, enforcement of regulations, and acquisition of better equipment. It should be supported through appropriate education, training, and the commitment of the healthcare staff and management and healthcare managers within an effective policy and legislative framework.

54 ENVIRONMENTAL SCIENCES↗

The JPL MSAT mobile laboratory and the pilot field experiments

A Mobile Laboratory/Propagation Measurement Van (PMV) was developed to support the field experiments of the Mobile Satellite Experiment (MSAT-X) Project. This van was designed to provide flexibility, self-sufficiency and data acquisition to allow for both measurement of equipment performance and the mobile environment. The design philosophy and implementation of the PMV are described. The Pilot Field Experiments and an overall description of the three experiments in which the PMV was used are described.

Berner, Jeff B.↗

Development of a software interface for optical disk archival storage for a new life sciences flight experiments computer

The current Life Sciences Laboratory Equipment (LSLE) microcomputer for life sciences experiment data acquisition is now obsolete. Among the weaknesses of the current microcomputer are small memory size, relatively slow analog data sampling rates, and the lack of a bulk data storage device. While life science investigators normally prefer data to be transmitted to Earth as it is taken, this is not always possible. No down-link exists for experiments performed in the Shuttle middeck region. One important aspect of a replacement microcomputer is provision for in-flight storage of experimental data. The Write Once, Read Many (WORM) optical disk was studied because of its high storage density, data integrity, and the availability of a space-qualified unit. In keeping with the goals for a replacement microcomputer based upon commercially available components and standard interfaces, the system studied includes a Small Computer System Interface (SCSI) for interfacing the WORM drive. The system itself is designed around the STD bus, using readily available boards. Configurations examined were: (1) master processor board and slave processor board with the SCSI interface; (2) master processor with SCSI interface; (3) master processor with SCSI and Direct Memory Access (DMA); (4) master processor controlling a separate STD bus SCSI board; and (5) master processor controlling a separate STD bus SCSI board with DMA.

Bartram, Peter N.↗

PV-Diesel Hybrid SCADA Experiment Network Design

The essential features of an experimental network for renewable power system satellite based supervisory, control and data acquisition (SCADA) are communication links, controllers, diagnostic equipment and a hybrid power system. Required components for implementing the network consist of two satellite ground stations, to satellite modems, two 486 PCs, two telephone receivers, two telephone modems, two analog telephone lines, one digital telephone line, a hybrid-power system equipped with controller and a satellite spacecraft. In the technology verification experiment (TVE) conducted by Savannah State University and Florida Solar Energy Center, the renewable energy hybrid system is the Apex-1000 Mini-Hybrid which is equipped with NGC3188 for user interface and remote control and the NGC2010 for monitoring and basic control tasks. This power system is connected to a satellite modem via a smart interface, RS232. Commands are sent to the power system control unit through a control PC designed as PC1. PC1 is thus connected to a satellite model through RS232. A second PC, designated PC2, the diagnostic PC is connected to both satellite modems via separate analog telephone lines for checking modems'health. PC2 is also connected to PC1 via a telephone line. Due to the unavailability of a second ground station for the ACTS, one ground station is used to serve both the sending and receiving functions in this experiment. Signal is sent from the control PC to the Hybrid system at a frequency f(sub 1), different from f(sub 2), the signal from the hybrid system to the control PC. f(sub l) and f(sub 2) are sufficiently separated to avoid interference.

Kalu, Alex↗

A Case Study of Modern PLC and LabVIEW Controls: Power Supply Controls for the ORNL ITER ECH Test Stand

Power Supply Controls are being developed at Oak Ridge National Laboratory (ORNL) to test transmission line components of the Electron Cyclotron Heating (ECH) system, with a focus on gyrotrons and waveguides, in support of the International Thermonuclear Experimental Reactor (ITER). The control is performed by several Programmable Logic Controllers (PLC s) located near the different equipment. A technique of Supervisory Control and Data Acquisition (SCADA) is presented to monitor, control, and log actions of the PLC s on a PC through use of Allen Bradley s Remote I/O communication interface coupled with an Open Process Control/Object Linking and Embedding [OLE] for Process Control (OPC) Server/Client architecture. The OPC data is then linked to a National Instruments (NI) LabVIEW system for monitoring and control. Details of the architecture and insight into applicability to other systems are presented in the rest of this paper. Future integration with an EPICS (Experimental Physics Industrial Control System) based mini-CODAC (Control, Data Access and Communication) SCADA system is under consideration, and integration considerations will be briefly introduced.