Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dark matter direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Insights from binary pulsars and laboratories into baryon number violation: Implications for GeV dark matter

Rare processes in laboratory and within astrophysical environments can be highly sensitive probes of baryon-number-violating interactions at the TeV scale. We demonstrate the power of neutron stars to constrain baryon-number violation by considering a minimal extension of the standard model involving a TeV-mass scalar mediator and a GeV scale Majorana fermion ψ . We find that a Δ B = 2 mass-loss process in binary pulsar systems via n → γ ψ and the subsequent scattering ψ n → π − K + places stringent constraints on the model parameter space. These limits will become much stronger, due to the possibility of Λ → γ ψ decays at the tree level, if the neutron star equation of state is hyperonic. We compare these constraints with ongoing and future collider experiments, n − n ¯ oscillations, and dinucleon decay searches at future large-scale neutrino experiments, finding that the binary pulsars bounds on couplings are significantly tighter for specific flavor combinations. Published by the American Physical Society 2024

baryons↗

Cosmological constraints on dark matter interactions with ordinary matter

Dark matter interactions with electrons or protons during the early Universe leave imprints on the cosmic microwave background and the matter power spectrum, and can be probed through cosmological and astrophysical observations. These interactions lead to momentum and heat exchange between the ordinary and dark matter components, which in turn results in a transfer of pressure from the ordinary to the dark matter. Here, we explore these interactions using a diverse suite of data: cosmic microwave background anisotropies, baryon acoustic oscillations, the Lyman-α forest, and the abundance of Milky-Way subhalos. We derive constraints using model-independent parameterizations of the dark matter–electron and dark matter–proton interaction cross sections and map these constraints onto concrete dark matter models. Our constraints are complementary to other probes of dark matter interactions with ordinary matter, such as direct detection, big bang nucleosynthesis, various astrophysical systems, and accelerator-based experiments. They exclude sufficiently large cross sections for a large range of dark matter masses, which cannot be accessed by direct-detection experiments due to the overburden from the Earth’s atmosphere or crust.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining spin-dependent light dark matter rates from neutron scattering

The scattering and absorption rates of light dark matter with electron spin-dependent interactions depend on the target’s spin response. We show how this response is encoded by the target’s dynamical magnetic susceptibility, which can be measured using neutron scattering. We directly use existing neutron scattering data to compute the dark matter scattering rate in a candidate target material, finding close agreement with the previous first-principles calculation at MeV dark matter masses. Complementary experiments and measurements can extend the reach of this technique to other dark matter models and masses, and identify promising target materials for future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ ⁢eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44–52 μ ⁢eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, 𝑔 𝑎⁢𝛾⁢𝛾 , in this mass range at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44 – 52 μ eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, g a γ γ , in this mass range at 90% confidence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphonon excitations from dark matter scattering in crystals

For direct detection of sub-MeV dark matter, a promising strategy is to search for individual phonon excitations in a crystal. We perform an analytic calculation of the rate for light dark matter ( keV < m DM < MeV ) to produce two acoustic phonons through scattering in cubic crystals such as GaAs, Ge, Si, and diamond. The multiphonon rate is always smaller than the rate to produce a single optical phonon, whenever the latter is kinematically accessible. In Si and diamond, there is a dark matter mass range for which multiphonon production can be the most promising process, depending on the experimental threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST

Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (weakly interacting massive particles WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret experimental data, have used a few different techniques over the past few decades. In this paper, we review techniques based on solely the primary scintillation channel, the ionization or secondary channel available at non-zero drift electric fields, and combined techniques that include a simple linear combination and weighted averages, with a brief discussion of the application of profile likelihood, maximum likelihood, and machine learning. Comparing results for electron recoils (beta and gamma interactions) and nuclear recoils (primarily from neutrons) from the Noble Element Simulation Technique (NEST) simulation to available data, we confirm that combining all available information generates higher-precision means, lower widths (energy resolution), and more symmetric shapes (approximately Gaussian) especially at keV-scale energies, with the symmetry even greater when thresholding is addressed. Near thresholds, bias from upward fluctuations matters. For MeV-GeV scales, if only one channel is utilized, an ionization-only-based energy scale outperforms scintillation; channel combination remains beneficial. We discuss here what major collaborations use.

argon↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperstealth dark matter and long-lived particles

A new dark matter candidate is proposed that arises as the lightest baryon from a confining 𝑆⁢𝑈⁡(𝑁) gauge theory which equilibrates with the Standard Model only through electroweak interactions. Surprisingly, this candidate can be as light as a few GeV. The lower bound arises from the intersection of two competing requirements: (i) the equilibration sector of the model must be sufficiently heavy, at least several TeV, to avoid bounds from colliders, and (ii) the lightest dark meson (that may be the dark 𝜂′, 𝜎, or the lightest glueball) has suppressed interactions with the SM and must decay before big bang nucleosynthesis. The low-energy dark sector consists of one flavor that is electrically neutral and an almost electroweak singlet. The dark matter candidate is the lightest baryon consisting of 𝑁 of these light flavors leading to a highly suppressed elastic scattering rate with the Standard Model (SM). The equilibration sector consists of vectorlike dark quarks that transform under the electroweak group, ensuring that the dark sector can reach thermal equilibrium with the SM in the early Universe. The lightest dark meson lifetimes vary between 10 −3 ≲ 𝑐⁢𝜏 ≲ 10 7 m, providing an outstanding target for LHC production and experimental detection. We delineate the interplay between the lifetime of the light mesons, the suppressed direct detection cross section of the lightest baryon, and the scale of equilibration sector that can be probed at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Leveraging Quantum Sensors for Dark Matter Detection

Recent measurements have demonstrated that superconducting qubit decoherence is affected by radiation. As a result, many groups around the world are working to better understand the relationship between different types of radiation and qubit response. This crucial to quantum error correction because radiation can cause correlated loss of information across multiple qubits on a chip, defeating error correction algorithms. Additionally, the fundamental energy scale at which superconducting qubits operate may enable their development as meV-scale detectors for HEP applications, such as the direct detection of dark matter. At Fermilab, we have two world-class underground facilities which are already being used to study this problem: NEXUS and QUIET. I will present on results from operating superconducting qubits in each of these facilities, and the potential implications towards utilizing qubits as sensors for a novel dark matter detector.

Baxter, Daniel [Texas U., Arlington]↗

Leveraging Quantum Sensors for Dark Matter Detection

Recent measurements have demonstrated that superconducting qubit decoherence is affected by radiation. As a result, many groups around the world are working to better understand the relationship between different types of radiation and qubit response. This crucial to quantum error correction because radiation can cause correlated loss of information across multiple qubits on a chip, defeating error correction algorithms. Additionally, the fundamental energy scale at which superconducting qubits operate may enable their development as meV-scale detectors for HEP applications, such as the direct detection of dark matter. At Fermilab, we have two world-class underground facilities which are already being used to study this problem: NEXUS and QUIET. I will present on results from operating superconducting qubits in each of these facilities, and the potential implications towards utilizing qubits as sensors for a novel dark matter detector.

Baxter, Daniel [Texas U., Arlington]↗

Kinetic Inductance Phonon-Mediated Detectors for Dark Matter: R&D at NEXUS

Superconducting thin films have long been used as phonon sensors, particularly in the field of dark matter (DM) direct detection, due to the meV-scale Cooper-pair binding energy. A novel class of these detectors based on microwave kinetic inductance detectors, dubbed Kinetic Inductance Phonon-Mediated Detectors (KIPMDs), offers an attractive architecture for microcalorimeters to probe DM down to the fermionic thermal relic mass limit of a few keV. Such a device featuring an aluminum resonator patterned onto a silicon substrate was operated at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. With this device we have demonstrated a resolution on the energy absorbed by the superconductor of 2.5 eV, a factor of two better than current state-of-the-art. In this talk, I will present our measurement of the energy resolution and phonon collection efficiency performed by exposing the bare substrate to a pulsed source of 470 nm photons. I will also discuss the path forward to obtaining in these devices the sub-eV resolution required to test the “Freeze-in” class of DM models. Finally, I will review other complementary efforts in our group to develop a superconducting qubit-based low-threshold detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microcalorimetry: The First Two Decades

Our group at GSFC began experimental and theoretical work on microcalorimetry almost twenty years ago, in August of 1982. Over the next 10 months, we completed the initial demonstration of a Si impurity thermometer-based calorimeter as an X-ray spectrometer. This successful demonstration resulted in the development by many investigators of scientific applications for microcalorimeters, ranging from optical spectroscopy to dark matter detection to particle physics applications. Many new technical approaches for cryogenic detectors were proposed by investigators and have been developed. In this presentation, I will describe the early development of microcalorimeters at GSFC and University of Wisconsin and the subsequent rapid growth of this work around the world The key milestones in the early development were the initial spectroscopy demonstrations and the selection of XRS, our microlcalorimeter-based instrument for the Advanced X-ray Astrophysics Facility (AXAF) and ultimately for ASTRO-E. An additional key event was the development of the direct detection of dark matter experiment and the formation of the Center for Particle Astrophysics. Both of these programs provided long term support for this technology in its precarious early days. A major additional technical step in the development of detectors was the demonstration of devices based on superconducting transition edge sensors (TES). These detectors promised (and have delivered) improved energy resolution and higher event rate capabilities. They couple naturally to SQUIDS, which operate well at the low temperatures where the detectors must operate. The past two decades have taken microcalorimeters from their infancy to applications in real experiments. I will provide an overview of the early development of the devices and review the breadth of the present technology and applications.

Moseley, Harvey↗

Scanning X-Ray Diffraction Microscopy for Diamond Quantum Sensing

An understanding of nano- and microscale crystal strain in chemical-vapor-deposition diamond is crucial to the advancement of diamond quantum technologies. In particular, the presence of such strain and its characterization presents a challenge to diamond-based quantum sensing and information applications-as well as for future dark-matter detectors, where the directional information about incoming particles is encoded in crystal strain. Here, we exploit nanofocused scanning x-ray diffraction microscopy to quantitatively measure crystal deformation from defects in diamond with high spatial and strain resolution. The combination of information from multiple Bragg angles allows stereoscopic three-dimensional modeling of strain-feature geometry; the diffraction results are validated via comparison to optical measurements of the strain tensor based on spin-state-dependent spectroscopy of ensembles of nitrogen-vacancy centers in the diamond. Finally, our results demonstrate both strain and spatial resolution sufficient for directional detection of dark matter via x-ray measurement of crystal strain and provide a promising tool for diamond growth analysis and improvement of defect-based sensing.

42 ENGINEERING↗

Low-energy Compton scattering in materials

Low-energy Compton scattering is an important background for sub-GeV dark matter direct-detection and other experiments. Current Compton scattering calculations typically rely on assumptions that are not valid in the low-energy region of interest, beneath ∼ 50 eV . Here we relate the low-energy Compton scattering differential cross section to the dielectric response of the material. Our new approach can be used for a wide range of materials and includes all-electron, band-structure, and collective effects, which can be particularly relevant at low energies. We demonstrate the strength of our approach in several solid-state systems, in particular, Si, Ge, GaAs, and SiC, which are relevant for current and proposed experiments searching for dark matter, neutrinos, and millicharged particles. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Anapole moment of neutrinos and radioactive sources near liquid xenon detectors

We show that placing a radioactive source such as 51 Cr near a liquid xenon detector may allow us to detect the contribution induced by the anapole moment to neutrino-electron scattering in the Standard Model (SM) at the 1 − 2⁢𝜎 level. Although the anapole moment of neutrinos induces a scattering rate with the same spectral shape as the neutral and charged current contributions, exposures of ∼ 60 ton × source run at XENONnT or XLZD may be enough to accumulate sufficient statistics for a detection. We also discuss a simple model where the anapole moment of neutrinos is enhanced or decreased with respect to the SM expectation, further demonstrating how a potential measurement of the anapole moment of neutrinos would allow us to constrain new physics.

dark matter direct detection↗

Piezoelectric bulk acoustic resonators for dark photon detection

The kinetically mixed dark photon is a simple, testable dark matter candidate with strong theoretical motivation. Detecting the feeble electric field dark photon dark matter produces requires extremely sensitive detectors. Bulk acoustic resonators (BARs), with their exceptionally high-quality phonon modes, are highly sensitive detectors, and have previously leveraged this sensitivity to search for gravitational waves in the MHz to GHz frequency range. The BAR phonons are typically read out by detecting the electric field generated by the BAR materials’ piezoelectricity. Here we show that this piezoelectricity also rewards such detectors sensitivity to dark photon dark matter, as the dark electric field can resonantly excite BAR phonons. A single 10 g piezoelectric BAR in a large, cold, environment can be orders of magnitude more sensitive to the kinetic mixing parameter than any current experiment, with only a month-long exposure and thermally limited backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗