Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Emission Current Transfer for Homopolar Machines

With the increasing electrification of transportation, the need for high power density electric machines is higher than ever. The required specific power for the more demanding applications, such as airplane propulsion, is over 20 kW/kg for multi-megawatt range power levels. Fully superconducting synchronous machines could reach the required performance, but significant challenges remain to be addressed such as AC losses management and rotating cryogenics implementation. Homopolar machines constitute the simplest electro-mechanical conversion systems possible, however the difficulty of establishing reliable and efficient low voltage, high DC current transfer from a stationary to a rotating system has prevented homopolar machines from competing with AC electrical machines. While sliding contacts or liquid metal contacts are feasible, they lead to high losses, high maintenance requirements and the use of environmentally unfriendly materials. We investigated field emission current transfer as an alternative to sliding contacts. We have demonstrated field emission current transfer in vacuum between a copper electrode and carbon nanotubes and diamond pyramids to evaluate the feasibility of contact-free current transfer for homopolar machines. The initial field emission testing was successfully demonstrated with current densities in the 10 mA/cm 2 range. The initial experiments validated the concept and supported the development of a roadmap for the development of contactless current transfer for homopolar machines, helped understand the limitations of the current test system and identify the key parameters that will lead to better performance.

99 GENERAL AND MISCELLANEOUS↗

The Grid Value of Ocean Current Energy in Florida: Preprint

Ocean current technology has been proposed as a potential contributor to Florida's energy portfolio. There has been limited investigation of how this energy would be valued when integrated into the Florida electrical grid. This study assesses three future grid scenarios to evaluate the impact of adding ocean current to each. NREL's capacity expansion model, Resource Planning Model, is used to identify the least-cost generation mix through 2050, with and without ocean current. The first scenario, Business as Usual, Base case assuming current policies, ocean current does not replace fossil-based technologies. In the second scenario, we allow solar and storage to have lower costs than the first scenario which allows ocean current to retire gas earlier and more variable generation technologies to be deployed. In the third scenario, the Florida carbon constraint 95 by 2050 from 2020 levels case, ocean current can play a bigger role in decarbonization than the two other cases when coupled with other technologies.

capacity expansion model↗

Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak

Open field line currents are intrinsic to DC helicity injection plasma startup and pose a challenge for inferring the plasma equilibrium with standard reconstruction analysis. Local helicity injection (LHI) is a type of DC helicity injection which uses small, modular current sources to drive force-free current along helical field lines to produce tokamak plasmas. MHD modeling and magnetic measurements during LHI indicate the injected current streams remain coherent as helical structures on the outboard edge of a core toroidal plasma that is tokamak-like in a toroidally averaged sense. To extract core plasma equilibrium properties, external magnetic diagnostics corrected for contributions from the injected current streams are fitted by a standard Grad-Shafranov equilibrium code. An iterative approach for estimating and subtracting the stream contributions from the diagnostic signals is described and applied to a model equilibrium database to reduce systematic errors introduced by the streams. Convergence is usually attained with 2 to 4 iterations, with derived equilibrium parameters matching the prescribed axisymmetric core values to within estimated experimental uncertainties. Accurate recovery of core parameters occurs when the ratio of the net toroidal windup current from the streams to the core plasma current is less than 0.2, which is typically satisfied in most experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance analysis and tank test validation of a hybrid ocean wave-current energy converter with a single power takeoff

This paper introduces a hybrid ocean wave-current energy converter (HWCEC) that harvests energy from ocean waves and current simultaneously with a single power takeoff (PTO). Specifically, the wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). The hybrid PTO with two one-way clutches converts bidirectional, up-and-down motion from the waves into unidirectional rotation of the generator. Meanwhile a third one-way clutch couples the MCT with the same generator. The wave and current can simultaneously or separately drive the same generator through different engagement and disengagement statuses of the one-way clutches. Time-domain simulation is conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under co-existing wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87% over either current turbine and wave energy converter acting individually, and it can reduce by up to 70% the peak-to-average power ratio compared with the wave energy converter on the tested conditions.

16 TIDAL AND WAVE POWER↗

Optimization of quasi-symmetric stellarators with self-consistent bootstrap current and energetic particle confinement

Quasi-symmetry can greatly improve the confinement of energetic particles and thermal plasma in a stellarator. The magnetic field of a quasi-symmetric stellarator at high plasma pressure is significantly affected by the bootstrap current, but the computational cost of accurate stellarator bootstrap calculations has precluded use inside optimization. Here, a new efficient method is demonstrated for optimization of quasi-symmetric stellarator configurations such that the bootstrap current profile is consistent with the geometry. The approach is based on the fact that all neoclassical phenomena in quasi-symmetry are isomorphic to those in axisymmetry. Therefore, accurate formulas for the bootstrap current in tokamaks, which can be evaluated rapidly, can be applied also in stellarators. The deviation between this predicted parallel current and the actual parallel current in the magnetohydrodynamic equilibrium is penalized in the objective function, and the current profile of the equilibrium is included in the parameter space. Quasi-symmetric configurations with significant pressure are thereby obtained with self-consistent bootstrap current and excellent confinement. In a comparison of fusion-produced alpha particle confinement across many stellarators, the new configurations have significantly lower alpha energy losses than many previous designs.

Landreman, M. (ORCID:000000027233577X)↗

Assessment of dynamic-screw-pinch-driven, current-scaled MagLIF target implosion performance using 3D magnetohydrodynamic simulations

Analytic studies and two-dimensional “clean” radiation-magnetohydrodynamic (rad-MHD) simulations employing dynamical similarity driver-target scaling prescriptions [Ruiz et al., Phys. Plasmas 30, 032708 (2023)] suggest that Magnetized Liner Inertial Fusion (MagLIF) target implosions can scale to > 10 MJ DT fusion yields when peak drive current is increased beyond 60 MA. We present results from three-dimensional (3D) rad-MHD simulations of similarity-scaled MagLIF target implosions at peak drive currents ranging from 15 to 40 MA. Simulations in this study suggest that magneto-Rayleigh–Taylor instability (MRTI) growth and feedthrough to the fuel region are more severe at higher drive current scales, which reduces the fusion yield compared to prior analytic and 2D clean simulation predictions. In contrast to standard MagLIF, simulations of current-scaled MagLIF target implosions driven by a dynamic screw pinch (DSP) demonstrate reduced MRTI feedthrough and greater fuel magnetization, resulting in improved thermonuclear performance and enhanced performance scaling with peak drive current. DSP drive enables additional scaling of the liner mass to increase liner radius but maintain implosion time, resulting in higher implosion velocities at the expense of increased susceptibility to MRTI. We present a current- and mass-scaled simulated DSP-MagLIF target implosion at the ∼ 40 MA peak current level that produces ignition scale performance, demonstrating a burn-averaged Lawson ignition parameter above unity and DT fusion yield above 1 MJ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

Origin of multifractality in solar wind turbulence: the role of current sheets

ABSTRACT In this work, a multifractal framework is proposed to investigate the effects of current sheets in solar wind turbulence. By using multifractal detrended fluctuation analysis coupled with surrogate methods and volatility, two solar wind magnetic field time series are investigated, one with current sheets and one without current sheets. Despite the lack of extreme-events intermittent bursts in the current sheet-free series, both series are shown to be strongly multifractal, although the current sheet-free series displays an almost linear behaviour for the scaling exponent of structure functions. Long-range correlations are shown to be the main source of multifractality for the series without current sheets, while a combination of heavy-tail distribution and non-linear correlations is responsible for multifractality in the series with current sheets. The multifractality in both time series is formally shown to be associated with an energy-cascade process using the p-model.

Gomes, Leonardo F.↗

Role of the junction voltage on the overflow current in light-emitting diodes

Quantum-well (QW)-based light emitters, such as light-emitting diodes (LEDs) and lasers, of various semiconductor materials experience a reduction in their efficiency when operating at higher temperatures, a phenomenon referred to as “thermal droop.” Among the various claims on the origins of thermal droop, an increased overflow current with increasing temperatures is a common contender. Since overflow of carriers can only occur when the junction voltage 𝑉 Junction approaches the built-in voltage 𝑉 BI of any diodes, we develop a simple method relating the difference between 𝑉 Junction and 𝑉 BI to approximate the upper limit of overflow occurring in QW-based light-emitting diodes. The measured difference between 𝑉 Junction and 𝑉 BI of state-of-the-art commercial blue and green In⁢Ga⁢N-based LEDs at temperatures up to ∼450 K suggests negligible overflow. To further experimentally verify the absence of overflow, we perform temperature-dependent electron emission spectroscopy on the same commercial blue and green LEDs and find no evidence of thermally enhanced overflow carriers up to ∼450 K. In agreement with our claims that 𝑉 Junction must approach 𝑉 BI for overflow to occur, two-dimensional temperature-dependent electrical simulations of violet, blue, and green LEDs including alloy disorder and V-defects demonstrate that overflow can be significant in violet LEDs, where the small band offset between the In⁢Ga⁢N QW and Ga⁢N cladding layers due to the larger QW bandgap requires larger 𝑉 Junction to reach standard operating current densities, thereby approaching 𝑉 BI . By contrast, simulations indicate that overflow is negligible in blue and green LEDs, whose smaller QW bandgaps result in smaller quasi-Fermi levels difference to reach significant carrier injection, resulting in a 𝑉 Junction much smaller than 𝑉 BI up to large operating current densities. Considering that overflow is negligible in blue and longer-wavelength LEDs, and our observations of the large thermal droop occurring at low current densities, where Shockley-Read-Hall (SRH) recombination dominates, we conclude that thermally enhanced SRH processes are the most significant contributor to thermal droop. Finally, we also simulate the carrier densities in the different QWs of a multiple-QW LED and observe a reduction in the total carrier density at a given operating current density, which results in a decrease in the total Auger-Meitner current of the LED from just the thermally enhanced carrier redistribution among QWs without taking any possible additional temperature dependence of their recombination coefficients. Taking all this into account, minimizing thermal droop effects in LEDs can be achieved by a reduction in defect density, using wider band gap p-n junction-defining cladding layers, and operating at higher currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optically induced umklapp shift currents in striped cuprates

Motivated by recent experiments that observed low-frequency second-order optical responses in doped striped superconductors, here we investigate the nonlinear electrodynamics of systems exhibiting a charge density wave (CDW) order parameter. Due to the Bragg scattering off the CDW order, an incoming spatially homogeneous electric field in addition to zero momentum current generates umklapp currents that are modulated in space at momenta of the reciprocal CDW lattice. In particular, here we predict and microscopically evaluate the umklapp shift current, a finite momentum analog of the regular shift current which represents the second-order optical process that downconverts homogeneous AC electric field into low-frequency, zero momentum current. Specifically, we evaluate real-time response functions within mean-field theory via the Keldysh technique and use the Peierls substitution to compute observables at finite momenta in lattice models. We find that systems with certain lattice symmetries (such as inversion symmetry), where the regular shift current is disallowed, may give rise to the umklapp one. We apply our framework to investigate lattice symmetries in layered materials with helical-like stripes and show that both types of shift currents provide insight into the nature of intertwined phases of matter. Finally, we discuss the relation of our findings to recent experiments in striped superconductors. Published by the American Physical Society 2024

Materials Science↗

Examining the Feasibility of Modeling the Inner Current Loop of a Grid-Following Inverter in the Phasor-Based Solver

Historically, when modeling a grid-following (GFL) inverter in the phasor domain, the fast inner current loop is typically ignored. To achieve a more accurate modeling, the authors have attempted to model the inner current loop in the phasor domain, but experienced significant numerical stability issues. This paper conducts a detailed analysis and provides insight into the feasibility of modeling the inner current loop of a GFL inverter in the phasor domain. It points out that: a) because of the neglection of the inverter filter dynamic, the bandwidth of the inner current loop becomes infinite with typical parameters in the phasor domain, resulting in an inaccurate representation of the actual inner current loop, whose bandwidth is typically between 600 Hz to 2 kHz, and b) the relatively large simulation time step in the phasor simulation causes numerical stability issues when simulating such an inner current loop with an infinite bandwidth. Detailed electromagnetic (EMT) and phasor modeling, and frequency response analysis are performed to explain this phenomenon. The findings of this paper explain why it is inappropriate to model the fast current loop of a GFL inverter in the phasor domain.

Mohiuddin, Sheik Mohammad↗

Reduced-Order Parameterized Short-Circuit Current Model of Inverter-Interfaced Distributed Generators

The short-circuit response of inverter-interfaced distributed generators (IIDGs) is not adequately represented in many conventional protection studies. This paper presents an in-depth analysis of IIDG behavior during grid faults and proposes a more accurate reduced-order parameterized short-circuit current (RPSC) model of inverters. Typical inverter components are thoroughly investigated to identify those that play dominant roles during faults. The paper shows that the current limiter is the dominant factor for the steady-state fault-current of inverter; while the inverter filter along with the severity of the voltage disturbance largely determine the initial transient spike of inverter fault current. The proposed model is low-order and can be used in large scale simulations. The parameters of the proposed RPSC model can be extracted from laboratory experiments without requiring proprietary manufacturer information. The proposed fault-current model is analogous to the well-known synchronous machine model that segregates the inverter fault current into subtransient, transient, and steady-state fault currents. Finally, experimental and simulation tests are presented to validate the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method of coating an electrical current collector and electrodes resulting therefrom

The present invention is directed to a method of coating an electrical current collector comprising treating a portion of a surface of the electrical current collector with an adhesion promoting composition to deposit a treatment layer over the portion of the surface of the electrical current collector, wherein the resulting surface of the electrical current collector comprises (a) a treated portion comprising the treatment layer and (b) a non-treated portion that lacks the treatment layer; electrodepositing an electrodeposited coating layer from an electrodepositable coating composition onto the surface of the electrical current collector to form a coated electrical current collector; and rinsing the coated electrical current collector, wherein the electrodeposited coating layer substantially adheres to the treated portion of the surface and does not adhere to the non-treated portion of the surface. Also disclosed are electrodes and electrical storage devices.

Oakes, Landon J.↗

Exploiting Spin Fluctuations for Enhanced Pure Spin Current

We demonstrate the interplay of pure spin current, spin-polarized current, and spin fluctuation in 3d Ni x Cu 1–x . By tuning the compositions of the Ni x Cu 1–x alloys, we separate the effects due to the pure spin current and spin-polarized current. By exploiting the interaction of spin current with spin fluctuation in suitable Ni-Cu alloys, we obtain an unprecedentedly high spin Hall angle of 46%, about 5 times larger than that in Pt, at room temperature. Furthermore, we show that spin-dependent thermal transport via anomalous Nernst effect can serve as a sensitive magnetometer to electrically probe the magnetic phase transitions in thin films with in-plane anisotropy. As a result, the enhancement of spin Hall angle by exploiting spin current fluctuation via composition control makes 3d magnets functional materials in charge-to-spin conversion for spintronic application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electrochemical mechanisms of leakage‐current in photovoltaic modules

Abstract This paper analyzes the mechanisms and pathways for leakage current flow observed in Si photovoltaic modules subjected to high temperature and humidity and a large voltage bias with respect to ground. The current inside of the frame is in the form of electron motion, but in the glass and polymer, it is in at least a large part attributable to the movement of ions. When the mode of current flow changes from electronic to ionic conduction, electrochemical reactions will take place at the interface. This can include reactions that produce volatile chemical species like H 2 , CO x , and O 2 , along with ionic species such as OH − and H 3 O + . Here, we see evidence of the importance of different charge carriers with different diffusion rates and the influence of electrochemical processes involved. The application of negative voltage to the cell circuit affects the resistivity of glass producing surfaces with poor conductivity but with some increases in the electrochemical potential producing complicated interactions that are important when the voltage is changed. In the polymer, there is the development of a space charge region and a chemical gradient providing two oppositional forces to current flow, which when released create a complicated discharge process. Here, we give a basic understanding of the charge/discharge of PV cells highlighting how the specific mechanisms are important in understanding some of the degradation processes in PV modules. We find that there is evidence of multiple significant charge carrier species with different diffusion time scales. The glass/polymer interface forms a depleted region of higher resistance after prolonged exposure to current. Charge also builds up at the polymer to cell antireflective coating interface and mostly flows to the gridlines to experience electrochemical reactions. These complexities result in non‐linear behavior where the apparent resistivities of the different layers change during charge/discharging processes, making the modeling of the current flow extremely difficult.

14 SOLAR ENERGY↗

The effect of current and lambda on white-etch-crack failures

White etching cracks (WECs) have been associated with premature failure of wind turbine roller bearings. Various drivers for the generation of WECs have been identified such as loading conditions, slip, steel quality, lubrication, hydrogen embrittlement, corrosion fatigue cracking, and stray electrical currents passing through the surface. Here, in this work, a benchtop test rig utilizing a three-ring-on-roller test configuration was used to investigate the effect of electrical current and operation in different lubricating regimes, defined by lambda (λ), on high-quality bearing steel samples tested in a commercially available power transmission EP gear lubricant. It was observed that there is an inverse correlation between the magnitude of electric current applied to the ring/ roller system and time-to-failure. Higher current magnitudes lead to shorter time-to-failure than lower current magnitudes, with macropitting as the main failure mode. Sub-surface investigation revealed the presence of WECs in all cases. For the same current magnitude, tests conducted in boundary and mixed lubrication regimes showed that time-to-failure increased as lambda increased, and the tests resulted in WEC related macropits, whereas tests conducted in near-hydrodynamic regime resulted in surface damage with no macropit. It was also noted that a shift toward near-hydrodynamic lubrication resulted in a distinct surface distress on the roller surface. Furthermore, there seems to be a transition in the mixed regime during which the surface distress occurred. The damage on the surface of the test samples resembled non-spatially, periodic, groove-like corrugations and, in some cases, crater-like depressions. Sub-surface imaging, performed by sequential sectioning, revealed the presence of WECs in all cases, and broad, branching cracks that were more prevalent under the more severe boundary conditions.

17 WIND ENERGY↗