Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Temperature Sensor using a Silicon-on-Insulator (SOI) Timer for Very Wide Temperature Measurement

A temperature sensor based on a commercial-off-the-shelf (COTS) Silicon-on-Insulator (SOI) Timer was designed for extreme temperature applications. The sensor can operate under a wide temperature range from hot jet engine compartments to cryogenic space exploration missions. For example, in Jet Engine Distributed Control Architecture, the sensor must be able to operate at temperatures exceeding 150 C. For space missions, extremely low cryogenic temperatures need to be measured. The output of the sensor, which consisted of a stream of digitized pulses whose period was proportional to the sensed temperature, can be interfaced with a controller or a computer. The data acquisition system would then give a direct readout of the temperature through the use of a look-up table, a built-in algorithm, or a mathematical model. Because of the wide range of temperature measurement and because the sensor is made of carefully selected COTS parts, this work is directly applicable to the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program--Jet Engine Distributed Engine Control Task and to the NASA Electronic Parts and Packaging (NEPP) Program. In the past, a temperature sensor was designed and built using an SOI operational amplifier, and a report was issued. This work used an SOI 555 timer as its core and is completely new work.

Patterson, Richard L.↗

Extreme-Temperature Carbon- and Ceramic-Matrix Composite Nozzle Extensions for Liquid Rocket Engines

The United States (US) National Aeronautics and Space Administration (NASA) and its US industry partners are developing extreme-temperature composite nozzle extensions for a variety of cryogenic liquid rocket engine propulsion systems. Applications under consideration at the NASA Marshall Space Flight Center (MSFC) include launch vehicle (upper stage), in-space, and lunar lander descent/ascent propulsion systems. Composite material systems of interest include carbon-carbon (C-C) and carbon/silicon-carbide (C-SiC) composites, as well as modified versions of such composites (coatings, mixed matrices, oxidation inhibitors, etc.). Missions addressed include access to low Earth orbit, the lunar surface, and more distant destinations. Cryogenic upper-stage and in-space liquid rocket engines are optimized for performance through the use of high area ratio nozzles to fully expand combustion gases to low exit pressures, increasing exhaust velocities. As a result of the large size of such nozzles, and the related engine performance requirements, composite nozzle extensions are being considered to reduce mass impacts. Currently, metallic and foreign composite nozzle extensions used on the Atlas V, Delta IV, Falcon 9, and Ariane 5 launch vehicles represent the state-of-the-art. Such extensions are limited to use at or slightly above 2000°F (1093°C). Materials under development by MSFC and its industry partners have the potential to operate at temperatures up to (or above) 4250°F (2343°C). Marshall Space Flight Center efforts are aimed at (a) further developing the technology and databases needed to enable the use of composite nozzle extensions on cryogenic liquid rocket engines, (b) developing and demonstrating low-cost capabilities for testing and qualifying such nozzle extensions, and (c) advancing the US domestic supply chain for nozzle extensions. Through the Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) Programs, low-level internal MSFC research projects, and teaming arrangements with domestic industry partners, composite material design, development, hot-fire test, and evaluation efforts are progressing. Hot- fire engine tests of subscale hardware have been conducted using oxygen/hydrogen (LOX/H2), oxygen/methane (LOX/CH4), and oxygen/kerosene (LOX/RP-1) propellants. These engine tests at MSFC have enabled the evaluation of both heritage and state-of-the-art material systems, demonstrating the initial capabilities of the extreme temperature materials and their fabrication methods. Recent, ongoing, and potential future work supporting cryogenic propulsion systems development will be presented. The composite nozzle extension technology and test capabilities being developed are intended to support both NASA and US Department of Defense requirements, as well as those of the broader Commercial Space industry.

Valentine, Peter G.↗

Emerging hypersonic propulsion technology

Currently there is a renewal of interest in the utilization of air breathing engines for hypersonic flight. The use of such engines in accelerative missions is discussed, and the nature of the trade-off between engine thrust-to-weight ratio and specific impulse is highlighted. It is also pointed out that the use of a cryogenic fuel such as liquid hydrogen offers the opportunity to develop both precooled derivatives of turboaccelerator engines and new cryogenic engine cycles, where the heat exchange process plays a significant role in the engine concept. The continuing challenges of developing high speed supersonic combustion ramjet engines are discussed. The paper concludes with a brief review of the difficult discipline of vehicle integration, and the challenges of both ground and flight testing.

Curran, E. T.↗

Engineering and fabrication cost considerations for cryogenic wind tunnel models

Design and fabrication cost drivers for cryogenic transonic wind tunnel models are defined. The major cost factors for wind tunnel models are model complexity, tolerances, surface finishes, materials, material validation, and model inspection. The cryogenic temperatures require the use of materials with relatively high fracture toughness but at the same time high strength. Some of these materials are very difficult to machine, requiring extensive machine hours which can add significantly to the manufacturing costs. Some additional engineering costs are incurred to certify the materials through mechanical tests and nondestructive evaluation techniques, which are not normally required with conventional models. When instrumentation such as accelerometers and electronically scanned pressure modules is required, temperature control of these devices needs to be incorporated into the design, which requires added effort. Additional thermal analyses and subsystem tests may be necessary, which also adds to the design costs. The largest driver to the design costs is potentially the additional static and dynamic analyses required to insure structural integrity of the model and support system.

Boykin, R. M., Jr.↗

Autonomous Cryogenic Load Operations: Knowledge-Based Autonomous Test Engineer

The Knowledge-Based Autonomous Test Engineer (KATE) program has a long history at KSC. Now a part of the Autonomous Cryogenic Load Operations (ACLO) mission, this software system has been sporadically developed over the past 20 years. Originally designed to provide health and status monitoring for a simple water-based fluid system, it was proven to be a capable autonomous test engineer for determining sources of failure in the system. As part of a new goal to provide this same anomaly-detection capability for a complicated cryogenic fluid system, software engineers, physicists, interns and KATE experts are working to upgrade the software capabilities and graphical user interface. Much progress was made during this effort to improve KATE. A display of the entire cryogenic system's graph, with nodes for components and edges for their connections, was added to the KATE software. A searching functionality was added to the new graph display, so that users could easily center their screen on specific components. The GUI was also modified so that it displayed information relevant to the new project goals. In addition, work began on adding new pneumatic and electronic subsystems into the KATE knowledge base, so that it could provide health and status monitoring for those systems. Finally, many fixes for bugs, memory leaks, and memory errors were implemented and the system was moved into a state in which it could be presented to stakeholders. Overall, the KATE system was improved and necessary additional features were added so that a presentation of the program and its functionality in the next few months would be a success.

Schrading, J. Nicolas↗

Fundamentals of Cryogenics

Analysis of the extreme conditions that are encountered in cryogenic systems requires the most effort out of analysts and engineers. Due to the costs and complexity associated with the extremely cold temperatures involved, testing is sometimes minimized and extra analysis is often relied upon. This short course is designed as an introduction to cryogenic engineering and analysis, and it is intended to introduce the basic concepts related to cryogenic analysis and testing as well as help the analyst understand the impacts of various requests on a test facility. Discussion will revolve around operational functions often found in cryogenic systems, hardware for both tests and facilities, and what design or modelling tools are available for performing the analysis. Emphasis will be placed on what scenarios to use what hardware or the analysis tools to get the desired results. The class will provide a review of first principles, engineering practices, and those relations directly applicable to this subject including such topics as cryogenic fluids, thermodynamics and heat transfer, material properties at low temperature, insulation, cryogenic equipment, instrumentation, refrigeration, testing of cryogenic systems, cryogenics safety and typical thermal and fluid analysis used by the engineer. The class will provide references for further learning on various topics in cryogenics for those who want to dive deeper into the subject or have encountered specific problems.

Testing↗

Engineering changes to the 0.1m cryogenic wind tunnel at Southampton University

The more important changes to the 0.1 m cryogenic wind tunnel since its completion in 1977 are outlined. These include detailed improvements in the fan drive to allow higher speeds, and the provision of a test section leg suitable for use with a magnetic suspension and balance system. The instrumentation, data logging, data reduction and tunnel controls were also improved and modernized. A tunnel performance summary is given.

Goodyer, M. J.↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Because the surface of the Moon drops to cryogenic temperatures, no solar-powered lunar spacecraft have reliably operated beyond a single lunar day. Passive thermal control cannot keep a spacecraft sufficiently warm for the 354-hour lunar night, and active thermal control requires a dramatic increase in battery mass at the expense of payload mass. Extreme conditions seen on the lunar surface suggest a radioisotope solution is ideal, but mass, cost, and schedule are inconsistent with low-cost frequent flight intent of the commercial lunar payload services (CLPS) program. To solve the issue of lunar night survivability without radioisotope sources of power and heat, a lunar power hibernation approach is being developed at the Glenn Research Center, which exploits the ability of common 18650 Lithium-ion cells to passively survive cryogenic freeze-thaw cycles and recover without apparent performance degradation. A key aspect of this hibernation approach is the use of cryogenically operable electronics that safely manage the restoration of the battery thermal environment at lunar dawn. A spacecraft utilizing this strategy will operate into the lunar night on batteries until the state of charge or spacecraft temperature reaches a predetermined threshold. At this point, systems are shut down and the battery is isolated from the main bus to prevent charge or discharge during the freezing and thawing transitions. The system remains passive until lunar dawn, where temperatures can reach as low as 50 K. All electronics must be tolerant to these conditions. When the solar arrays are finally illuminated at lunar dawn, the main bus power electronics will initiate a “cold start” and begin regulating array power. The main bus electronics must be designed to operate at cryogenic temperatures. Array power is used to warm the battery and passive electronics back to operational temperatures. Once batteries are returned to normal temperatures, diagnostics and precharging is performed, as needed, and the battery is reconnected. The overall spacecraft system reboots and returns to nominal operations until lunar night returns. To assure that we can develop batteries suited for many hibernation freeze/thaw cycles, STMD Space Technology Research Grant Program (STRG) has selected two principal investigators that will thoroughly characterize of the Li-ion cell through the freeze-thaw process, investigate degradation mechanisms, and identify potential diagnostic techniques. STMD STRG is also funding an investigation of Gallium-Nitride semiconductors for cryogenic power applications. This work includes physics-informed modeling that considers cryogenic conductivity, carrier mobility, and quantum effects that govern semiconductor performance at cryogenic temperatures. These models can enable engineers to develop accurate cryogenic simulation models that assist in the design of power controls stable over the entire lunar surface temperature range. Meanwhile, Glenn is performing cryogenic testing of batteries and electronics, establishing design guidelines for power applications in extreme cold lunar environment, and potentially developing a hibernation technology demonstrator. The hibernation approach will enable low-cost lunar robotic missions to extend their operating lifetime to many months while minimizing development costs and impact on payload capacity. The need for cryogenically operable electronics is restricted to only main bus power and battery controls, as the majority of systems simply need to passively tolerate cryogenic temperatures. This allows developers to continue to exploit the cost savings of legacy and COTS hardware with minimum modification. For these reasons, lunar power hibernation is a viable near-term solution for lunar night survivability for solar powered commercial landers.

Space power↗

Cryogenic Oxygen Storage Modules with Carbon Dioxide Sequestration for Environmental Control and Life Support Applications

NASA Kennedy Space Center engineers developed a Cryogenic Oxygen Storage Module (COSM) to store oxygen in solid-state form and deliver it as a gas to an end-use environmental control and/or life support system. Additionally, the COSM can scrub out nuisance or containment gases such as carbon dioxide and/or water vapor in conjunction with supplying oxygen, forming a synergistic system when used in a closed-loop application. Closed-loop life support systems require both oxygen supply and removal of toxic or nuisance gases such as CO2 from the breathing loop. In most deployed systems, these two requirements are accomplished independently. COSM combines these capabilities to work simultaneously which may allow for reduced system volume, mass, complexity and cost of a rebreathing device.

Jeffrey A Kohler↗

A study of cryogenic container thermodynamics during propellant transfer. Volume 2 - Final engineering report

This report describes the results of a study of cryogenic container thermodynamics during propellant transfer. The purpose of this study is to provide analytical and empirical descriptions of the transient phenomena occurring in cryogenic transfer lines and receive tanks during initial propellant transfer. A further basic objective is to identify those conditions which give rise to the possibility of tank implosion, and to establish the procedures and/or systems necessary to eliminate this possibility.

R M Vernon↗

Bearings and seals for cryogenic fluids.

Bearings and seals in rocket engine turbopumps operating directly in cryogenic propellant, discussing design, lubrication and material requirements

Scibbe, H. W.↗

Cryogenic Technology, part 1

Different engineering problems associated with the design of mechanisms and systems to operate in a cryogenic environment are discussed. The focal point for the entire engineering effort was the design of the National Transonic Facility, which is a closed-circuit cryogenic wind tunnel. The papers covered a variety of mechanical, structural, and systems design subjects including thermal structures insulation systems, noise, seals, and materials.

Source record↗

The Development of NDE Techniques for Large Cryogenic Storage Tanks

Objectives of this project are: (1) Develop and demonstrate NDE techniques to evaluate the condition of large cryogenic Dewars (typically 50,000 to 900,000 gaL). (2) These tanks are used across NASA for launch pads, engine test stands, cryogenic wind tunnels and other facilities: they represent a major investment. (3) Issues addressed: (1) Insulation integrity of existing Dewars (powdered insulation under vacuum or sometimes ambient pressure (LO2), (2) Post fabrication insulation verification without full chill-down to avoid thermal cycling the tank (fatigue limitation of piping and compaction of Perlite).

Youngquist, Robert↗

Evaluation of EHD film thickness for cryogenic fluids

Some aerospace rocket engine applications require that bearings operate at high speeds with cryogenic rocket fuel as the only liquid lubricant. Analyses and field data on these bearings indicate that life would be limited to a few minutes if they operated unlubricated. The extent to which cryogenic fluids are capable of generating elastohydrodynamic films is, therefore, an area of concern and is investigated in this paper. Results from experimental and analytical work at the authors' laboratories indicate sufficient films are not generated to lubricate the bearing reliably. This conclusion is supported by experimental data and analysis which show liquid nitrogen, the cryogenic fluid tested, to be isoviscous.

Merriman, T. L.↗