6 K Cryocooler Program

The report summarizes experimental and theoretical work on an Oxford type Stirling Cycle mechanical precooler operating in the temperature range of 13-20 degrees Kelvin. It includes measurements of the thermal losses of particle regenerators made from lead, and rare earth and rare earth alloys in an operating three stage cryocooler. A 6 K hybrid cooler is designed using the technical information gathered on regenerator performance.

Gully, Willy

Helium Dilution Cryocooler for Space Applications

NASA's New Millenium Program Space Technology presents the Helium Dilution Cryocooler for Space Applications. The topics include: 1) Capability; 2) Applications; and 3) Advantages. This paper is in viewgraph form.

Roach, Pat

Adaptive Vibration Reduction Controls for a Cryocooler With a Passive Balancer

In this paper an adaptive vibration reduction control (AVRC) design is described for a Stirling cryocooler combined with a passive balancer. The AVRC design was based on a mass-spring model of the cooler and balancer, and the AVRC algorithm described in this paper was based on an adaptive binary search. Results are shown comparing the baseline uncontrolled cooler with no balancer, the cooler with the balancer, and, finally, the cooler with the balancer and the AVRC. The comparison shows that it may be possible to meet stringent vibration reduction requirements without an active balancer.

Kopasakis, George

Final Qualification and Early On-Orbit Performance of the HESSI Cryocooler

The High Energy Solar Spectroscopic Imager (HESSI) spacecraft was launched on February 5, 2002. It now observes the Sun with the finest angular and energy resolutions ever achieved from a few keV to hundreds of keV, using an array of nine germanium detectors operating at 75K. The spacecraft was originally scheduled for launch in July 2000, but a vibration facility mishap damaged the primary structure of the spacecraft, along with the cryocooler, This paper describes issues in the qualification of a replacement for the original flight cooler, and describes early on-orbit performance.

Boyle, R. F.

Miniature Joule Thomson (JT) CryoCoolers for Propellant Management

A proof-of-concept project is proposed here that would attempt to demonstrate how miniature cryocoolers can be used to chill the vacuum jacket line of a propellant transfer line and thus to achieve transfer line pre-chill, zero boil off and possible propellant densification. The project would be performed both at UCF and KSC, with all of the cryogenic testing taking place in the KSC cryogenic test bed. A LN2 line available in that KSC test facility would serve to simulate a LOX transfer line. Under this project, miniature and highly efficient cold heads would be designed. Two identical cold heads will be fabricated and then integrated with a JT-type cryogenic system (consisting of a common compressor and a common external heat exchanger). The two cold heads will be integrated into the vacuum jacket of a LN2 line in the KSC cryo lab, where the testing will take place.

Kapat, Jay

Finding a Cold Needle in a Warm Haystack: Infrared Imaging Applied to Locating Cryocooled Crystals in Loops

We demonstrate the use of inbred imaging to locate crystals mounted in cryoloops and cryopreserved in a nitrogen gas stream at 100K. In the home laboratory crystals are clearly seen in the infrared images with light transmitting through the sample while irradiating the crystal from behind, and with illumination from a direction perpendicular to the direction of view. The crystals transmit and reflect infrared radiation differently from the surrounding mother liquor and loop. Because of differences in contrast between crystals and their surrounding mother liquor, it is possible to clearly identify the crystal position. In use at the synchrotron, with robotically mounted crystals the small depth of field of the lens required the recording of multiple images at different focal points. Image processing techniques were then used to produce a clear image of the crystal. The resulting infrared images and intensity profiles show that infrared imaging can be a powerful complement to visual imaging in locating crystals in cryocooled loops.

Snell, E. H.

STRV Cryocooler Tip Motion Suppression

The Space Technology Research Vehicle (STRV-1b) scheduled to fly at the beginning of June 1994, has a cryocooler vibration suppression experiment aboard doing motion suppression of the tip of the coldfinger. STRV-1b is a bread box sized satellite to be launched on the next flight of the Ariane-4.

STRV piezo-electric translators applique ceramic a

Design and progress report for compact cryocooled sapphire oscillator 'VCSO'

We report on the development of a compact cryocooled sapphiere oscillator 'VCSO', designed as a higher-performance replacement for ultra-stable quartz oscillators in local oscillator, cleanup, and flywheel applications in the frequency generation and distribution subsystems of NASA's Deep Space Network (DSN).

oscillator

Multi-stage pulse tube cryocooler with acoustic impedance constructed to reduce transient cool down time and thermal loss

The cool down time for a multi-stage, pulse tube cryocooler is reduced by configuring at least a portion of the acoustic impedance of a selected stage, higher than the first stage, so that it surrounds the cold head of the selected stage. The surrounding acoustic impedance of the selected stage is mounted in thermally conductive connection to the warm region of the selected stage for cooling the acoustic impedance and is fabricated of a high thermal diffusivity, low thermal radiation emissivity material, preferably aluminum.

Gedeon, David R.

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.

A Turbo-Brayton Cryocooler for Aircraft Superconducting Systems

Hybrid turboelectric aircraft-with gas turbines driving electric generators connected to electric propulsion motors-have the potential to transform aircraft design. Decoupling power generation from propulsion enables innovative aircraft designs, such as blended-wing bodies, with distributed propulsion. These hybrid turboelectric aircraft have the potential to significantly reduce emissions, decrease fuel burn, and reduce noise, all of which are required to make air transportation growth projections sustainable. The power density requirements for these electric machines can only be achieved with superconductors, which in turn require lightweight, high-capacity cryocoolers.

Dietz, Anthony

Characterization Testing of Lockheed Martin Standard Micro Pulse Tube Cryocooler

This paper describes the thermal performance, exported vibration, and magnetics testing and results of a Lockheed Martin standard micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 150 and 300 K. The cooler was driven with Thales XPCDE4865 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 84 and 98 Hz. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the exported forces and torques of the cooler were measured with the cooler driven by Thales CDE7232 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 88 and 96 Hz. The exported forces were dependent on both input power and drive frequency. Moreover, the automatic vibration reduction function of the drive electronics was able to decrease the force in the compressor axis to below 10 mN 0-peak. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

McKinley, I. M.

High Efficiency Megawatt Machine Rotating Cryocooler Conceptual Design

Some of the challenges associated with developing electric aircraft propulsion systems include developing powertrain components that are both efficient and light-weight. In particular, electric motors must simultaneously achieve high efficiency by minimizing electrical and mechanical losses while also achieving high specific power by increasing the torque and/or speed. Normally increasing torque or speed will increase electrical and mechanical losses. The High Efficiency Megawatt Machine (HEMM) minimizes electrical losses by incorporating a superconductor to enable increased current on the rotor. And the rotor spins in a vacuum to minimize thermal and mechanical losses. Some organizations have been developing superconducting rotors for similar reasons using either cryogenic fluid transfer systems, fully immersed cryogenic cooling, and in a few cases utilized built-in cryogenic cooling on the rotor using a Brayton or Stirling system but the implementation was too large or inefficient for effective motor integration. Instead, a new approach for cryogenically cooling the superconducting rotor coil with an embedded rotating cryocooler is presented that fits completely within the rotating shaft.

Dyson, Rodger W.

High Efficiency Megawatt Machine Rotating Cryocooler Conceptual Design

Some of the challenges associated with developing electric aircraft propulsion systems include developing powertrain components that are both efficient and light-weight. In particular, electric motors must simultaneously achieve high efficiency by minimizing electrical and mechanical losses while also achieving high specific power by increasing the torque and/or speed. Normally increasing torque or speed will increase electrical and mechanical losses. The High Efficiency Megawatt Machine (HEMM) minimizes electrical losses by incorporating a superconductor to enable increased current on the rotor. And the rotor spins in a vacuum to minimize thermal and mechanical losses. Some organizations have been developing superconducting rotors for similar reasons using either cryogenic fluid transfer systems, fully immersed cryogenic cooling, and in a few cases utilized built-in cryogenic cooling on the rotor using a Brayton or Stirling system but the implementation was too large or inefficient for effective motor integration. Instead, a new approach for cryogenically cooling the superconducting rotor coil with an embedded rotating cryocooler is presented that fits completely within the rotating shaft.

Dyson, Rodger W.

Characterization Testing of Lockheed Martin High-Power Micro Pulse Tube Cryocooler

This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

Rodriguez, Jose I.

Characterization Testing of Lockheed Martin Micro1-2 Cryocoolers Optimized for 220 K Environment

The Mapping Imaging Spectrometer for Europa (MISE) Instrument on the Europa Clipper mission has baselined a Lockheed Martin high-power Micro1-2 pulse tube cryocooler operating at 135 Hz with a 220 K heat rejection temperature. This paper describes the testing and results of two Lockheed Martin Micro1-2 coolers optimized for these conditions. The thermal performance of the microcoolers was measured in vacuum for heat reject temperatures between 220 and 230 K. The coolers were operated with input powers ranging from 5 W to 40 W and drive frequency between 125 Hz and 145 Hz. The optimal drive frequency was strongly dependent on heat reject temperature. In addition, the exported forces and torques of the coolers were measured at 300 K heat rejection for input powers ranging from 5 W to 60 W and drive frequency between 120 Hz and 160 Hz. The exported forces were dependent on both piston amplitude and drive frequency. Moreover, the following were measured on one of the coolers: DC and AC magnetic fields at various locations, the off-state conductance of the pulse tube, and the effect of inclination angle of the pulse tube relative to gravity on the performance of the cooler. Finally, one of the coolers was subjected to random vibration testing.

Rodriguez, J.I.

Characterization Testing of Space-Flight Lockheed Martin Micro1-2 Cryocooler for the Mapping Imaging Spectrometer for Europa (MISE)

The Mapping Imaging Spectrometer for Europa (MISE) instrument on the Europa Clipper mission uses a Lockheed Martin “high-power” Micro1-2 pulse tube cryocooler with a heat rejection temperature around 220 K to provide cooling at 80 K. This paper describes the thermal performance and exported forces characterization testing and results of the space-flight Lockheed Martin Micro1-2 cooler optimized for these conditions. Prior to these characterization tests, the cooler passed random vibration and thermal vacuum cycling at Lockheed Martin.

Rodriguez, Jose

Thermal Vacuum Chamber Demonstration of a Cryocooled, HTS Rotor for a 1.4 MW Electric Machine for Electrified Aircraft Propulsion

Aircraft with electrified propulsion systems require electric machines that are very lightweight and highly efficient. Advancements to the state of the art are required to meet this demand. This is particularly true for large transport aircraft with more than about 150 passengers, which will require electric machines with power ratings in the 1 to 30+ MW range. At this scale of power, superconducting technology becomes attractive for electrified aircraft propulsion to increase efficiency and reduce mass [1]. A mass reduction relative to non-superconducting machines can result from an increase in the specific power of the machine and indirectly through a significant reduction in the amount of waste heat generated on the aircraft, which reduces the mass of the thermal management system [2]. NASA’s high efficiency megawatt motor (HEMM) is a 1.4 MW partially superconducting machine that is being developed to achieve an efficiency greater than 98% and electromagnetic specific power greater than 16 kW/kg. HEMM contains a copper stator operating at an average temperature around 423 K and a superconducting rotor composed of no-insulation 2nd generation high temperature superconducting (HTS) coils that operates around 60 K. The superconducting coils are conductively cooled by a pulse tube cryocooler embedded inside and rotating with the rotor shaft. This paper presents a full-scale demonstration of the rotor in a thermal vacuum chamber at the designed operating temperature. The test was designed to validate the design of HEMM’s rotor, namely the ability to operate the 2G HTS coils at their rated direct current in a relevant thermal environment while being conductively cooled.

high temperature superconductors