Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cover optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Solid-State Architecture Batteries for Enhanced Rechargeability and Safety (SABERS) Beyond Li-Ion: Technology to Enable Next-Generation Sustainable Electric

All-electric vertical take-off and landing vehicles (eVTOL) for urban air mobility (UAM) concepts face numerous challenging technical barriers before their introduction into the consumer marketplace. The primary barrier to overcome is developing an energy storage system that meets rigorous aerospace safety and performance criteria. The performance metrics for eVTOL vehicles are at least two times greater than those of electric ground vehicles. Furthermore, inherently non-flammable batteries are essential for the safe operation of commercial electric aero vehicles. The SABERS concept proposes a battery that meets the critical performance criteria by developing a solid-state architecture battery utilizing a high-capacity sulfur-selenium cathode and lithium metal anode. The combination of sulfur and selenium offers a balanced energy-to-power density ratio, which can be tailored to the specific application by altering the stoichiometric ratios of sulfur to selenium. This hybrid cathode will be developed using NASA-patented holey graphene technology as a highly conductive, ultra-lightweight electrode scaffold. A solid-state electrolyte will be used as a safe, non-flammable replacement for the highly flammable liquid organic electrolytes currently in SOA lithium-ion batteries. This solid-state lithium-sulfur/selenium cell will be designed in a serial stacking configuration to enable the dense packaging of the battery cells. The serial stacking configuration is termed a bipolar stack, which has the advantages of reducing overall cell weight, simplifying the interfaced connections for the cell, and minimizing the cooling requirements. Lastly, the optimization of battery components will occur through a robust and rigorous combination of various computational modeling techniques covering multiple length scales. The expected result will be a fully solid-state battery with operational temperatures up to 150°C, providing the required energy density, discharge rates, and inherent safety to meet the strict aerospace mission performance criteria. The SABERS team employed novel materials development, computational modeling, and design-of-experiments (DOE) optimization studies in their research. This presentation will show the results of these studies and demonstrate a feasible path for solid-state cells with a specific energy greater than 400 Wh/kg to enable electric aircraft.

Computational Modeling↗

Enabling Space Exploration Medical System Development Using a Tool Ecosystem

The NASA Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element is utilizing a Model Based Systems Engineering (MBSE) approach to enhance the development of systems engineering products that will be used to advance medical system designs for exploration missions beyond Low Earth Orbit. In support of future missions, the team is capturing content such as system behaviors, functional decompositions, architecture, system requirements and interfaces, and recommendations for clinical capabilities and resources in Systems Modeling Language (SysML) models. As these products mature, SysML models provide a way for ExMC to capture relationships among the various products, which includes supporting more integrated and multi-faceted views of future medical systems. In addition to using SysML models, HRP and ExMC are developing supplementary tools to support two key functions: 1) prioritizing current and future research activities for exploration missions in an objective manner; and 2) enabling risk-informed and evidence-based trade space analysis for future space vehicles, missions, and systems. This paper will discuss the long-term HRP and ExMC vision for the larger ecosystem of tools, which include dynamic Probabilistic Risk Assessment (PRA) capabilities, additional SysML models, a database of system component options, and data visualizations. It also includes a review of an initial Pilot Project focused on enabling medical system trade studies utilizing data that is coordinated across tools for consistent outputs (e.g., mission risk metrics that are associated with medical system mass values and medical conditions addressed). This first Pilot Project demonstrated successful operating procedures and integration across tools. Finally, the paper will also cover a second Pilot Project that utilizes tool enhancements such as medical system optimization capabilities, post-processing, and visualization of generated data for subject matter expert review, and increased integration amongst the tools themselves.

Amador, Jennifer R.↗

Enabling Space Exploration Medical System Development Using a Tool Ecosystem

The NASA Human Research Program's (HRP) Exploration Medical Capability (ExMC) Element is utilizing a Model Based Systems Engineering (MBSE) approach to enhance the development of systems engineering products that will be used to advance medical system designs for exploration missions beyond Low Earth Orbit. In support of future missions, the team is capturing content such as system behaviors, functional decompositions, architecture, system requirements and interfaces, and recommendations for clinical capabilities and resources in Systems Modeling Language (SysML) models. As these products mature, SysML models provide a way for ExMC to capture relationships among the various products, which includes supporting more integrated and multi-faceted views of future medical systems. In addition to using SysML models, HRP and ExMC are developing supplementary tools to support two key functions: 1) prioritizing current and future research activities for exploration missions in an objective manner; and 2) enabling risk-informed and evidence-based trade space analysis for future space vehicles, missions, and systems. This paper will discuss the long-term HRP and ExMC vision for the larger ecosystem of tools, which include dynamic Probabilistic Risk Assessment (PRA) capabilities, additional SysML models, a database of system component options, and data visualizations. It also includes a review of an initial Pilot Project focused on enabling medical system trade studies utilizing data that is coordinated across tools for consistent outputs (e.g., mission risk metrics that are associated with medical system mass values and medical conditions addressed). This first Pilot Project demonstrated successful operating procedures and integration across tools. Finally, the paper will also cover a second Pilot Project that utilizes tool enhancements such as medical system optimization capabilities, post-processing, and visualization of generated data for subject matter expert review, and increased integration amongst the tools themselves.

Amador, Jennifer R.↗

Fast spherical search algorithm

This paper describes an algorithm to search a number of spherical points and find the points that are within a given distance to a given point. The described algorithm is not optimal, but is easy to implement. Basically, it utilizes a number of spherical coverings to build the data structure. Results of an implementation are presented.

Liebe, Carl Christian↗

The Scientific Importance of Returning Airfall Dust as a Part of Mars Sample Return (MSR)

Dust transported in the martian atmosphere is of intrinsic scientific interest and has relevance for the planning of human missions in the future. The MSR Campaign, as currently designed, presents an important opportunity to return serendipitous, airfall dust. The tubes containing samples collected by the Perseverance rover would be placed in cache depots on the martian surface perhaps as early as 2023–24 for recovery by a subsequent mission no earlier than 2028–29, and possibly as late as 2030–31. Thus, the sample tube surfaces could passively collect dust for multiple years. This dust is deemed to be exceptionally valuable as it would inform our knowledge and understanding of Mars' global mineralogy, surface processes, surface-atmosphere interactions, and atmospheric circulation. Preliminary calculations suggest that the total mass of such dust on a full set of tubes could be as much as 100 mg and, therefore, sufficient for many types of laboratory analyses. Two planning steps would optimize our ability to take advantage of this opportunity: (1) the dust-covered sample tubes should be loaded into the Orbiting Sample container (OS) with minimal cleaning and (2) the capability to recover this dust early in the workflow within an MSR Sample Receiving Facility (SRF) would need to be established. A further opportunity to advance dust/atmospheric science using MSR, depending upon the design of the MSR Campaign elements, may lie with direct sampling and the return of airborne dust.

Monica M. Grady↗

Utility of BRDF Models for Estimating Optimal View Angles in Classification of Remotely Sensed Images

Statistical classification of remotely sensed images attempts to discriminate between surface cover types on the basis of the spectral response recorded by a sensor. It is well known that surfaces reflect incident radiation as a function of wavelength producing a spectral signature specific to the material under investigation. Multispectral and hyperspectral sensors sample the spectral response over tens and even hundreds of wavelength bands to capture the variation of spectral response with wavelength. Classification algorithms then exploit these differences in spectral response to distinguish between materials of interest. Sensors of this type, however, collect detailed spectral information from one direction (usually nadir); consequently, do not consider the directional nature of reflectance potentially detectable at different sensor view angles. Improvements in sensor technology have resulted in remote sensing platforms capable of detecting reflected energy across wavelengths (spectral signatures) and from multiple view angles (angular signatures) in the fore and aft directions. Sensors of this type include: the moderate resolution imaging spectroradiometer (MODIS), the multiangle imaging spectroradiometer (MISR), and the airborne solid-state array spectroradiometer (ASAS). A goal of this paper, then, is to explore the utility of Bidirectional Reflectance Distribution Function (BRDF) models in the selection of optimal view angles for the classification of remotely sensed images by employing a strategy of searching for the maximum difference between surface BRDFs. After a brief discussion of directional reflect ante in Section 2, attention is directed to the Beard-Maxwell BRDF model and its use in predicting the bidirectional reflectance of a surface. The selection of optimal viewing angles is addressed in Section 3, followed by conclusions and future work in Section 4.

Valdez, P. F.↗

Optimizing RHESSI X-ray Imaging

RHESSI X-ray imaging is possible with angular resolution as fine as 2 arcsec (FWHM) at energies from as low as 3 keV to >100 keV. However, taking full advantage of this capability has proven to be challenging given the Fourier-transform imaging technique that is used, specific instrumental considerations that must be taken into account, and the many different options of the available image reconstruction algorithms. Such considerations as the best reconstruction algorithm to use, the optimal weighting of the different Fourier components, deciding between short image integration times and rapid imaging cadence, the different energy ranges covered by the 9 detectors, the effect of pulse pile-up and albedo, etc. must all be taken into account in obtaining and interpreting RHESSI X-ray images. This poster describes different techniques for optimizing the image reconstruction depending on the science objectives - identifying compact or extended sources, searching for source motion, obtaining the best photometry, determining the believability of different features in an image, etc. The emphasis is on making full use of data from all the RHESSI detectors, including the ones behind the finest grids when warranted by the source structure. This is the case for the hard X-ray emission along the ribbons of the flare on 2005 May 13 reported by Liu et al. (2007) and this event will be used as an example.

Dennis, Brian R.↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through-transmission mode using two transducers, or in pulse-echo mode. The transducer is a unique combination of material, design, and fabrication technique. It is based on single-crystal lead magnesium niobate lead titanate (PMN-PT) piezoelectric material. As compared to the commonly used piezoceramics, this piezocrystal has superior piezoelectric and elastic properties, which results in devices with superior bandwidth, source level, and power requirements. This design necessitates a single resonant frequency. However, by operating in a transverse length-extensional mode, with the electric field applied orthogonally to the extensional direction, resonators of different sizes can share common electrodes, resulting in a multiply-resonant structure. With carefully sized resonators, and the superior bandwidth of piezocrystal, the resonances can be made to overlap to form a smooth, wide-bandwidth characteristic.

Liang, Yu↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through transmission mode using two transducers, or in pulse-echo mode.

Liang, Yu↗

Astrodynamics 1975; Conference, Nassau, Bahamas, July 28-30, 1975, Technical Papers

Articles are grouped under four headings: (1) dynamics and control of satellites; (2) satellite mission analysis; (3) Aeros-B and Symphonie satellite engineering problems; (4) optimization and control techniques applied to solar space heating and cooling of buildings. Topics covered include: communications and earth survey satellite systems, a system of two counter-orbiting satellites measuring GRT-predicted nodal drag, statistical mechanics studies of the spatial density function of orbiting space junk, attitude control of satellites, nutation dampers, low thrust inertial guidance and ascent inertial guidance, a shuttle-launched multi-comet intercept mission, preflight and in-flight analysis of the Atmosphere Explorer (AE-C) satellite, and launch-encounter strategy for the Mariner 1977 Jupiter-Saturn mission. Individual items are announced in this issue.

Powers, W. F.↗

New inertial actuator provides isolation and stabilization in microgravity conditions

Experiments in materials and fluids processing have been conducted, or are planned, that take advantage of the low-g environment offered by space-based platforms. While the specific goals of the experiments vary, a common objective is to see improved results from the processes over those that would be obtained from similar ground-based experiments. While the space-based processing environment does offer a low-g environment, it is not disturbance free. Results of experiments already conducted, particularly those in manned vehicles, show that spacecraft induced disturbances still limit what can be achieved in materials processing. The duration of actual micro-g level environments is shorter than desired and periods of milli-g activity levels are not uncommon. While small scale experiments can be configured to overcome some of the vehicle disturbance sources, larger scale processing devices and commercial activities will require alternative methods to reduce the influences of spacecraft vibrations. Applied Technology Associates, Inc., (ATA), in cooperation with NASA Lewis Research Center, is developing hardware to provide a sustained micro-g experiment environment. This work is being sponsored under a Small Business Innovation Research (SBIR) program, which is currently in the Phase 2 development stage. ATA's approach is based on an inertial actuator, which when used as part of a closed-loop stabilization system, rejects unwanted disturbances to the experiment package. A prototype of the actuator has been fabricated and used in a laboratory demonstration to prove the principle of operation. ATA's presentation emphasized the development and testing of the Digital Materials Processing Experiment (DAMPER) inertial actuator. Physical and performance characteristics of the device are presented. Technical issues, including further optimization of the actuator's performance and plans for additional laboratory experiments, are also covered.

Blackburn, John↗

Active impedance matching of complex structural systems

Viewgraphs on active impedance matching of complex structural systems are presented. Topics covered include: traveling wave model; dereverberated mobility model; computation of dereverberated mobility; control problem: optimal impedance matching; H2 optimal solution; statistical energy analysis (SEA) solution; experimental transfer functions; interferometer actuator and sensor locations; active strut configurations; power dual variables; dereverberation of complex structure; dereverberated transfer function; compensators; and relative power flow.

Macmartin, Douglas G.↗

Multidisciplinary design integration system for a supersonic transport aircraft

An aircraft preliminary design system which provides the multidisciplinary communications and couplings between several engineering disciplines is described. A primary benefit of this system is to demonstrate advanced technology multidisciplinary design integration methodologies. The current version includes the disciplines of aerodynamics and structures. Contributing engineering disciplines are coupled using the Global Sensitivity Equation approach to influence the global design optimization problem. A high speed civil transport configuration is used for configuration trade studies. Forty four independent design variables are used to control the cross-sectional areas of wing rib and spar caps and the thicknesses of wingskincover panels. A total of 300 stress, strain, buckling and displacement behavioral constraints and minimum gages on the design variables were used to optimize the idealized wing structure. The goal of the designs to resize the wing cover panels and internal structure for minimum mass.

Dovi, A. R.↗

NASA's Planned Return to the Moon: Global Access and Anytime Return Requirement Implications on the Lunar Orbit Insertion Burns

Lunar orbit insertion LOI is a critical maneuver for any mission going to the Moon. Optimizing the geometry of this maneuver is crucial to the success of the architecture designed to return humans to the Moon. LOI burns necessary to meet current NASA Exploration Constellation architecture requirements for the lunar sortie missions are driven mainly by the requirement for global access and "anytime" return from the lunar surface. This paper begins by describing the Earth-Moon geometry which creates the worst case (delta)V for both the LOI and the translunar injection (TLI) maneuvers over the full metonic cycle. The trajectory which optimizes the overall (delta)V performance of the mission is identified, trade studies results covering the entire lunar globe are mapped onto the contour plots, and the effects of loitering in low lunar orbit as a means of reducing the insertion (delta)V are described. Finally, the lighting conditions on the lunar surface are combined with the LOI and TLI analyses to identify geometries with ideal lighting conditions at sites of interest which minimize the mission (delta)V.

Garn, Michelle↗

Designing the X-Ray Microcalorimeter Spectrometer for Optimal Science Return

Recent advances in X-ray microcalorimeters enable a wide range of possible focal plane designs for the X-ray Microcalorimeter Spectrometer (XMS) instrument on the future Advanced X-ray Spectroscopic Imaging Observatory (AXSIO) or X-ray Astrophysics Probe (XAP). Small pixel designs (75 microns) oversample a 5-10" PSF by a factor of 3-6 for a 10 m focal length, enabling observations at both high count rates and high energy resolution. Pixel designs utilizing multiple absorbers attached to single transition-edge sensors can extend the focal plane to cover a significantly larger field of view, albeit at a cost in maximum count rate and energy resolution. Optimizing the science return for a given cost and/or complexity is therefore a non-trivial calculation that includes consideration of issues such as the mission science drivers, likely targets, mirror size, and observing efficiency. We present a range of possible designs taking these factors into account and their impacts on the science return of future large effective-area X-ray spectroscopic missions.

X-rays↗

Optimization Strategies for Sensor and Actuator Placement

This paper provides a survey of actuator and sensor placement problems from a wide range of engineering disciplines and a variety of applications. Combinatorial optimization methods are recommended as a means for identifying sets of actuators and sensors that maximize performance. Several sample applications from NASA Langley Research Center, such as active structural acoustic control, are covered in detail. Laboratory and flight tests of these applications indicate that actuator and sensor placement methods are effective and important. Lessons learned in solving these optimization problems can guide future research.

Padula, Sharon L.↗

An Imaging Spectrometric Observatory (ISO)

The Imaging Spectrometric Observatory (ISO) is designed for low light level spectroscopy of both the day and night side of the earth. The instrument is composed of five spectrometers, each of which covers part of the total wavelength range of 30 to 1300 nm spanned by the instrument. Wavelength resolution varies between 0.2 and 0.6 nm over the spectral range. The five spectrometers are each optimized for a portion of the spectrum by the choice of mirror reflective coatings and detector photocathode materials. The full spectral range for each spectrometer is covered in a total of 11 grating steps. The Imaging Spectrometric Observatory was flown for the first time on the Spacelab 1 mission during which it acquired almost 40 hr of observations. The ISO investigation to be flown on the Atmospheric Laboratory for Applications and Science (ATLAS 1) mission will draw on the experience gained from the data gathered on Spacelab 1. The detector system in each spectrometer was upgraded to provide both higher sensitivity at low light levels and simultaneous imaging over larger spectral segments than was achieved on Spacelab 1. In addition, the instrument and the observing sequences were modified to allow observation of the sun in the extreme ultraviolet. A summary of ISO parameters for ATLAS 1 (scheduled for late 1990) is given.

Torr, M. R.↗

Efficiency enhancement of dual-mode traveling wave tubes at saturation and in the linear range by use of spent-beam refocusing and multistage depressed collectors

An axisymmetric, multistage depressed collector of fixed geometric design was evaluated in conjunction with an octave-bandwidth, dual-mode TWT. The TWT was operated over a wide range of conditions to simulate different applications. The collector was operated in three-, four-, and five-stage configurations, and its performance was optimized (within the constraint of fixed geometric design) over the range of TWT operating conditions covered. For operation of the dual-mode TWT at and near saturation, the collectors increased the TWT overall efficiency by a factor of 2 1/2 to 3 1/2. Collector performance was relatively constant for both the high and low TWT modes and for operation of the TWT across an octave bandwidth. For operation of the TWT in the linear, low-distortion range, collector efficiencies of 90 percent and greater were obtained, leading to a five- to twelvefold increase in the TWT overall efficiency for the range of operating conditions covered and reasonably high (greater than 25 percent) overall efficiencies well below saturation.

Ramins, P.↗