Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data: Preprint

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management↗

A comparison of two independent measurements and analysis of jet aircraft flyover noise

Flyover noise measurements were made simultaneously by two groups. The measurements were made close to one another for the same flyover conditions and with similar measurement procedures, but with different acoustic equipment and personnel. Each group also independently processed the data in accordance with FAR 36 procedures, indluding corrections to reference meteorological, performance, and flight-path conditions. Measured and corrected data, from 24 controlled flyovers processed by both groups, are compared and the differences in the results obtained by the two groups are discussed. It is observed that the average value of the difference between the groups' measured acoustic descriptors (PNL, PNLTM, and EPNL) was less than or = 0.8 db; the average difference for the corrected descriptors (PNL, PNLTM, and EPNL) was less than or = 1.5 db. Causes of the differences were found to be mainly related to different spectrum extrapolation and preemphasis techniques used by the two groups.

Hosier, R. N.↗

Unexplained Discontinuity in the US Radiosonde Temperature Data: Stratosphere - Part 2

In part I of this paper, the United States (US) radiosonde temperature data are shown to have significant and unexplained inhomogeneities in the mid-troposphere. This part discusses the differences between observations taken at 0 and 12 UTC especially in the stratosphere by the Vaisala RS80 radiosondes that are integrated within the National Weather Service's (NWS) Micro-ART system. The results show that there is a large maxima in the horizontal distribution of the monthly means of the 0/12 UTC differences over the central US that is absent over Canada and this maxima is as large as 5 C at 10 hPa. The vertical profiles of the root-mean-square of the monthly means are much larger in the US than those else where. The data clearly shows that the 0/12 UTC differences are largely artificial especially over the central US and originate in the post processing software at observing stations, thus confirming the findings in part I. Special flight data from the NWS's test facility at Sterling, Va. have been obtained. This data can be used to deduce the bias correction applied by Vaisala's post processing system. By analyzing the correction data, it can be shown that the inconsistencies with non-US Vaisala RS80 data as well as most of the large 0/12 UTC differences over the US can be accounted for by multiplying the reported elapsed time (i.e. time since launch) by the factor which is incorrectly applied by the post processing software. After being presented with the findings in this paper, Vaisala further isolated the source of the inconsistencies to a software coding error in the radiation bias correction scheme. The error effects only the software installed at US stations.

Redder, Christopher R.↗

Improving Brightness Temperature Measurements near Coastal Areas for SMAP

The Soil Moisture Active Passive (SMAP) mission is designed to acquire L-band radiometer measurements for the estimation of soil moisture with 0.04 m3/m3 volumetric accuracy in the top 5 cm for vegetation with water content of less than 5 kg/m2. In regions near the coast or near inland bodies of water, the signal measured by the SMAP radiometer contains emissions from land and water, resulting in errors in the soil moisture estimation. In this paper, the effort to extract the brightness temperature (TB) according to the land fraction or water fraction (depending on the center of the footprint location) from the affected SMAP measurements was addressed. A single pixel correction algorithm was applied and its performance was evaluated over simulated data. A data-driven approach for the estimation of land and water TB for data correction was developed. The correction algorithm was then applied to real data and its performance was assessed over the SMAP soil moisture retrievals. We showed that the single pixel algorithm is an effective and computationally efficient algorithm for removing land or water TB contamination from the SMAP data.

Julian Chaubell↗

Image Reconstruction of Imatron Electron-Beam Tomography Data

In this paper we describe the development of a filtered backprojection image reconstruction algorithm for an Imatron Electron-Beam Tomography (EBT) scanner. Raw data, software to perform data correction routines, and a technical document on the data format were all provided by Imatron. This document describes the basic geometry of the EBT scanner and the steps of the image reconstruction algorithm. Finally we demonstrate that the image quality our reconstruction algorithm is comparable with the reconstructed images provided by Imatron on an airport luggage data set.

42 ENGINEERING↗

SAAF: SANS data Analysis using Analytical Functions

The recently completed Extended Q-Range Small Angle Scattering Diffractometer (EQ-SANS) has put the focus on its software needs with renewed urgency. In a series of efforts, we aim at providing a complete set of software solutions on the EQ-SANS instrument. These programs include initial data processing, data correction and reduction, analytical model fitting to the scattering data, Monte Carlo simulation for structure determination, and virtual instrument simulation for experiment planning. SAAF is one such program for analytical data modeling. It takes the reduced EQ-SANS data and allows users to fit the data to analytical models. These models are easy to write. They can either be user written, or from the pre-supplied model library.

Data Analysis↗

Radiometric correction of LANDSAT data

The author has identified the following significant results. The six independent sensors of the multispectral band scanner are supposed to be identical; however, in actual practice, they may have different gain settings and offset factors, which result in the effect known as stripping (black lines at regular intervals) of the imagery. A simple two parameter method to correct the gain settings and offset factors of each of the sensors with respect to one sensor, taken as reference, was developed. This method assumes: (1) the response of a detector varies linearly with the radiance of radiation received, and (2) the means, as well as the standard deviations, of a reasonably large number of pixels, in a given wavelength band, are equal for each of the detectors for the radiometrically corrected data.

Dejesusparada, N.↗

Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial systems will also be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Participation in the Cluster Magnetometer Consortium for the Cluster Mission

Prof. M. G. Kivelson (UCLA) and Dr. R. C. Elphic (LANL) are Co-investigators on the Cluster Magnetometer Consortium (CMC) that provided the fluxgate magnetometers and associated mission support for the Cluster Mission. The CMC designated UCLA as the site with primary responsibility for the inter-calibration of data from the four spacecraft and the production of fully corrected data critical to achieving the mission objectives. UCLA was also charged with distributing magnetometer data to the U.S. Co-investigators. UCLA also supported the Technical Management Team, which was responsible for the detailed design of the instrument and its interface. In this final progress report we detail the progress made by the UCLA team in achieving the mission objectives.

Kivelson, Margaret↗

Progress on the Cluster Mission

Prof M. G. Kivelson and Dr. K. K. Khurana (UCLA (University of California, Los Angeles)) are co-investigators on the Cluster Magnetometer Consortium (CMC) that provided the fluxgate magnetometers and associated mission support for the Cluster Mission. The CMC designated UCLA as the site with primary responsibility for the inter-calibration of data from the four spacecraft and the production of fully corrected data critical to achieving the mission objectives. UCLA will also participate in the analysis and interpretation of the data. The UCLA group here reports its excellent progress in developing fully intra-calibrated data for large portions of the mission and an excellent start in developing inter-calibrated data for selected time intervals, especially extended intervals in August, 2001 on which a workshop held at ESTEC in March, 2002 focused. In addition, some scientific investigations were initiated and results were reported at meetings.

Kivelson, Margaret↗

Ozone Correction for AM0 Calibrated Solar Cells for the Aircraft Method

The aircraft solar cell calibration method has provided cells calibrated to space conditions for 37 years. However, it is susceptible to systematic errors due to ozone concentrations in the stratosphere. The present correction procedure applies a 1 percent increase to the measured I(sub SC) values. High band-gap cells are more sensitive to ozone absorbed wavelengths (0.4 to 0.8 microns) so it becomes important to reassess the correction technique. This paper evaluates the ozone correction to be 1+O3xFo, where O3 is the total ozone along the optical path, and Fo is 29.8 x 10(exp -6)/du for a Silicon solar cell, 42.6 x 10(exp -6)/du for a GaAs cell and 57.2 x 10(exp -6)/du for an InGaP cell. These correction factors work best to correct data points obtained during the flight rather than as a correction to the final result.

Snyder, David B.↗

Matrix error correction for digital data

A technique for digital data error detection and correction is disclosed which adds alignment and checksum bytes to three sides of a matrix (24) of digital data to be protected. This technique is particularly used for the recording and storage (16,18) of digital data on video tape medium (14). The digital data is treated as a matrix block (24). Checksum and alignment bytes are added (20) to the digital data before tape storage and stripped (22) therefrom after successful alignment checks and data validation. In particular, the first column may be used to provide alignment bytes of a predetermined value for each row. The last column provides row checksum bytes for the data in each row. The last row provides column check sum bytes for each column, excluding the column of alignment bytes. The data location at the intersection of the row of column checksum bytes and the column of row checksum bytes may be used as a checksum byte for either the row or column checksum bytes.

Dotson, Ronald S.↗

SeaWiFS technical report series. Volume 13: Case studies for SeaWiFS calibration and validation, part 1

Although the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Calibration and Validation Program relies on the scientific community for the collection of bio-optical and atmospheric correction data as well as for algorithm development, it does have the responsibility for evaluating and comparing the algorithms and for ensuring that the algorithms are properly implemented within the SeaWiFS Data Processing System. This report consists of a series of sensitivity and algorithm (bio-optical, atmospheric correction, and quality control) studies based on Coastal Zone Color Scanner (CZCS) and historical ancillary data undertaken to assist in the development of SeaWiFS specific applications needed for the proper execution of that responsibility. The topics presented are as follows: (1) CZCS bio-optical algorithm comparison, (2) SeaWiFS ozone data analysis study, (3) SeaWiFS pressure and oxygen absorption study, (4) pixel-by-pixel pressure and ozone correction study for ocean color imagery, (5) CZCS overlapping scenes study, (6) a comparison of CZCS and in situ pigment concentrations in the Southern Ocean, (7) the generation of ancillary data climatologies, (8) CZCS sensor ringing mask comparison, and (9) sun glint flag sensitivity study.

Hooker, Stanford B.↗

Atmospheric model for correction of spacecraft data.

Description of a radiative transfer model which has been used to correct Apollo photographic imagery for degradation arising from atmospheric scattering. The model was tested using aircraft scanner data, and an extrapolation was then made to spacecraft altitudes. Using standard meteorological data for the region of interest, it is possible to determine transmittance, path radiance, and total radiance from calculations made with the multiple scattering atmospheric model. Simple algorithms are presented which allow potential users of spacecraft sensor data to correct imagery for the deleterious effects due to the scattering of radiation under clear or hazy atmospheric conditions.

Turner, R. E.↗

Cloud cover determination in polar regions from satellite imagery

A definition is undertaken of the spectral and spatial characteristics of clouds and surface conditions in the polar regions, and to the creation of calibrated, geometrically correct data sets suitable for quantitative analysis. Ways are explored in which this information can be applied to cloud classifications as new methods or as extensions to existing classification schemes. A methodology is developed that uses automated techniques to merge Advanced Very High Resolution Radiometer (AVHRR) and Scanning Multichannel Microwave Radiometer (SMMR) data, and to apply first-order calibration and zenith angle corrections to the AVHRR imagery. Cloud cover and surface types are manually interpreted, and manual methods are used to define relatively pure training areas to describe the textural and multispectral characteristics of clouds over several surface conditions. The effects of viewing angle and bidirectional reflectance differences are studied for several classes, and the effectiveness of some key components of existing classification schemes is tested.

Barry, R. G.↗

SU-E-T-773: Use of a Commercial TPS for Deriving Exit Dose Distribution for Patient Specific QA with An EPID

Purpose: A method to derive exit dose distributions with a commercial treatment planning system for comparison to Epid measured doses. Methods: In contrast to published methods, we present an approach that uses a treatment planning system (Raystation, Raysearch) to calculate exit dose patterns based on a modified patient CT dataset. The EPID is assumed as water equivalent and therefore is represented as water filled ring in the images. This is done by: -Export a renamed copy of the patient CT and plan data set. —Manipulate the CT-data to a field of view of 1000 mm. — Insert the water filled cylinder ring, centered to the target point. — Manipulate plan file with the new target and dose prescription point. — Import and recalculate dose on the manipulated data set. — Export and extract exit field dose matrix from the cylinder (optional entrance dose). — Calibrate matrix to size and rebin data from the cylinder to EPID equivalent data. — Correct Epid measurement for scatter, position and field size. -Evaluate and compare data in Verisoft (PTW). Data manipulation and extraction is done by a simple tool (IDL, Exelis). Results: This method was tested on a Siemens Artiste 6MV for field sizes up to 27×27cm2 limited by used geometry and EPID size. First phantom measurements show good results for fields up to 20×20cm (pass rate > 95% for 3%, 3mm Gamma index) while larger fields have higher discrepancies towards the field edges. This might Result from off axis softening of the beam and the higher sensitivity of the detector to beam scatter. Conclusion: This method might simplify the use of exit dosimetry with the EPID for patient specific QA as it uses the dose calculation of a commercial treatment planning system. The concept was proven by phantom data sets, giving acceptable results.

60 APPLIED LIFE SCIENCES↗