Gust Load Alleviation Control and Gust Estimation for a High Aspect Ratio Wing Wind Tunnel Model

This paper presents the gust load alleviation (GLA) study of the aspect ratio 13.5 Common Research Model (CRM) wind-tunnel model. This study details the design of the GLA controller in preparation for wind-tunnel testing in the Transonic Dynamics Tunnel at NASA Langley Research Center. An aeroservolastic (ASE) model was first reduced using a model reduction method that takes advantage of the sinusoidal steady-state response. Then, the reduced model was used to design an extended-state Kalman filter which estimates the states and the sinusoidal gust input. The GLA control was then derived using the optimal control solution to a multi-objective cost function. The results of the GLA controller indicate a 75.6% reduction in wing-root strain while maintaining robust stability margins. The final paper will include performance under sub-optimal conditions, e.g., sensor noise, uncertainty in gust frequency, etc..

Christopher Forte↗

Gust Load Alleviation Control and Gust Estimation for a High Aspect Ratio Wing Wind Tunnel Model

This paper presents the gust load alleviation (GLA) study of the aspect ratio 13.5 Common Research Model (CRM) wind-tunnel model. This study details the design of the GLA controller in preparation for wind-tunnel testing in the Transonic Dynamics Tunnel at NASA Langley Research Center. An aeroservolastic (ASE) model is first reduced using a model reduction method that takes advantage of the sinusoidal steady-state response. Then, the reduced model is used to design an extended-state Kalman filter which estimates the states and the sinusoidal gust input. The GLA control is then derived using the optimal control solution to a multi-objective cost function. The results of the GLA controller indicate a 69.07% reduction in wing-root strain without sensor noise and 68.45% reduction with sensor noise, while maintaining robust stability margins. An adaptive GLA controller is developed for uncertain gust frequency and shows a 71.03% reduction in wing root strain compared to the non-adaptive control reduction of just 39.19%.

Christopher Forte↗

Load altering attack-tolerant defense strategy for load frequency control system

Cyber attacks are emerging threats to every information-oriented energy management system. By violating the cyber systems, the hacker can disrupt the security and stability due to the strong coupling between the cyber and physical facilities. In this paper, one type of cyber attacks designated as the load altering attack is studied for the power system frequency control, and corresponding defense strategies are proposed to improve the frequency control performance. Considering the difficulty of the application of model-based controller into large-scale power systems, a novel model-free defense framework is for the first time presented. Under this framework, both active defense and passive defense strategies are designed. The former assumes that the defender has the initiative to learn different attack scenarios. Adaptive defense strategies are implemented using the online attack identification information and off-line trained strategy pool. The latter assumes that the defender passively tolerates various attack scenarios via the pre-trained off-line strategy. Both approaches prove to be effective through validation based on the IEEE benchmark systems. The proposed defense framework and defense strategies can be extended to other energy control systems to enhance their attack tolerance capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The multiple-function multi-input/multi-output digital controller system for the AFW wind tunnel model

A real-time multiple-function digital controller system was developed for the Active Flexible Wing (AFW) Program. The digital controller system (DCS) allowed simultaneous execution of two control laws: flutter suppression and either roll trim or a rolling maneuver load control. The DCS operated within, but independently of, a slower host operating system environment, at regulated speeds up to 200 Hz. It also coordinated the acquisition, storage, and transfer of data for near real-time controller performance evaluation and both open- and closed-loop plant estimation. It synchronized the operation of four different processing units, allowing flexibility in the number, form, functionality, and order of control laws, and variability in selection of sensors and actuators employed. Most importantly, the DCS allowed for the successful demonstration of active flutter suppression to conditions approximately 26 percent (in dynamic pressure) above the open-loop boundary in cases when the model was fixed in roll and up to 23 percent when it was free to roll. Aggressive roll maneuvers with load control were achieved above the flutter boundary.

Hoadley, Sherwood T.↗

The multiple-function multi-input/multi-output digital controller system for the AFW wind-tunnel model

A real time multiple-function digital controller system was developed for the Active Flexible Wing (AFW) Program. The digital controller system (DCS) allowed simultaneous execution of two control laws: flutter suppression and either roll trim or a rolling maneuver load control. The DCS operated within, but independently of, a slower host operating system environment, at regulated speeds up to 200 Hz. It also coordinated the acquisition, storage, and transfer of data for near real time controller performance evaluation and both open- and closed-loop plant estimation. It synchronized the operation of four different processing units, allowing flexibility in the number, form, functionality, and order of control laws, and variability in the selection of the sensors and actuators employed. Most importantly, the DCS allowed for the successful demonstration of active flutter suppression to conditions approximately 26 percent (in dynamic pressure) above the open-loop boundary in cases when the model was fixed in roll and up to 23 percent when it was free to roll. Aggressive roll maneuvers with load control were achieved above the flutter boundary. The purpose here is to present the development, validation, and wind tunnel testing of this multiple-function digital controller system.

Hoadley, Sherwood T.↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Comparative Analysis of ML Techniques for Data-Driven Anomaly Detection, Classification and Localization in Distribution System

High penetration of Distributed Energy Resources (DERs), fundamental load behavior changes, controllable loads, and significant increase in Electrical Vehicles (EVs) lead to complex dynamic behavior of the electric distribution system. Increasing number of components also means more measurements, more data and more data anomalies. Detecting, classifying and localizing these anomalies are important for situational awareness, and at the same time, very challenging given increasing complexity of the system. Highly accurate and high-resolution analytical techniques are needed to support anomaly detection, classification and localization (AD-C-L) for monitoring, root cause analysis and decision making. This paper provides comprehensive review and analysis of the existing spatio-temporal AD-C-L techniques within the distribution system. Challenges for specific problems in AD-C- L have been also discussed in this paper. Existing AD-C- L techniques have been categorized and synthesized for specific merits and limitations of multiple Machine Learning (ML) methodologies using common developed metrics of performance. The comparative analysis is summarized and presented with the open research challenges and path forward for future research needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of active controls for the NASA F-8 digital fly-by-wire airplane

The design of a set of control laws for the NASA F-8 digital fly by wire research airplane is described. These control laws implement several active controls functions: maneuver load control, ride smoothing and departure boundary limiting. The criteria and methods which were used in the design of the control laws are also included. Results of linear analyses and nonlinear simulation are summarized.

Gera, J.↗

Pneumatic load compensating or controlling system

A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

Rogers, J. R.↗

Online distributed price-based control of DR resources with competitive guarantees

Demand response (DR) of building HVAC load can provide crucial demand-side flexibility for the future smart grid. Compared to direct load control, price-based control can respect the customers’ autonomy and privacy. However, it is challenging for price-based control to attain provable performance guarantees under future uncertainty. In this paper, we propose a framework for a utility to perform price-based control of flexible building load within the utility’s service area, in order to attain competitive performance guarantees in terms of controlling the system peak demand under future uncertainty. By adopting a two-step approach, our online price-based control solution can attain a provable competitive ratio for all possible realizations within a given uncertainty set. Simulation experiments demonstrate that, with a robustification procedure, our solution can perform well not only for worst-case inputs, but also for average-case inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Vehicle Ground Vibration Testing in Support of NASA Launch Vehicle Loads and Controls Analysis

The National Aeronautics and Space Administration (NASA) Ares Projects Office (APO) is continuing to make progress toward the final design of the Ares I crew launch vehicle and Ares V cargo launch vehicle. Ares I and V will form the space launch capabilities necessary to fulfill NASA's exploration strategy of sending human beings to the Moon, Mars, and beyond. As with all new space vehicles there will be a number of tests to ensure the design can be Human Rated. One of these is the Integrated Vehicle Ground Vibration Test (IVGVT) that will be measuring responses of the Ares I as a system. All structural systems possess a basic set of physical characteristics unique to that system. These unique characteristics include items such as mass distribution, frequency and damping. When specified, they allow engineers to understand and predict how a structural system like the Ares I launch vehicle behaves under given loading conditions. These physical properties of launch vehicles may be predicted by analysis or measured through certain types of tests. Generally, these properties are predicted by analysis during the design phase of a launch vehicle and then verified through testing before the vehicle is Human Rated. The IVGVT is intended to measure by test the fundamental dynamic characteristics of Ares I during various phases of operational/flight. This testing includes excitations of the vehicle in lateral, longitudinal, and torsional directions at vehicle configurations representing different trajectory points. During the series of tests, properties such as natural frequencies, mode shapes, and transfer functions are measured directly. These data will then be used to calibrate loads and Guidance, Navigation, and Controls (GN&C) analysis models for verifying analyses of Ares I. NASA launch vehicles from Saturn to Shuttle have undergone Ground Vibration Tests (GVTs) leading to successful launch vehicles. A GVT was not performed on the unmanned Delta III. This vehicle was lost during launch. Subsequent analyses indicated that had a GVT been conducted on the vehicle, problems with vehicle modes and control may have been discovered and corrected, avoiding loss of the vehicle/mission. This paper will address GVT planning, set-up, conduction and analyses, for the Saturn and Shuttle programs, and also focus on the current and on-going planning for the Ares I and V IVGVT.

Tuma, Margaret L.↗

Ratchetting behavior in viscoplasticity - A technical note

Viscoplastic models that use the Armstrong and Frederick (1966) kinematic hardening relationship are known to generally overpredict the observed accumulation of ratchet strains. The reason for this behavior is a consequence of the mathematics used to describe Hooke's law and the evolution equations for plastic strain and back stress. Conditions for ratchetting exist whenever there is a cycle-averaged mean stress present over a cyclic loading path. Two types of controlled loading paths are often studied: cyclic relaxation is the ratchet mechanism associated with displacement (strain) control, while cyclic creep is the ratchet mechanism associated with load (stress) control. Overcoming the possible adverse trends in predicted ratchetting behavior is a difficult task, and how one ought to go about doing this is not yet completely clear. We therefore choose to discuss the mathematical cause of ratchetting and how it has been dealt with to date, but make no attempt to correct this flaw.

Freed, Alan D.↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

A power and load priority control concept as applied to a Brayton cycle turbo-electric generator.

This paper describes a system to regulate the speed and power output of a Brayton Cycle Power System under varying load. A typical user load profile is applied and a simple load priority and parasitic load is used for system regulation. Power storage is provided by batteries with charge and discharge converters to demonstrate support capability. The breadboard system is tested with the Brayton Cycle Demonstrator at the National Aeronautics and Space Administration, Manned Space Craft Center, Houston, Texas.

Kelsey, E. L.↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust Distribution System Load Restoration With Time-Dependent Cold Load Pickup

Service restoration is one of the critical functions to enable the future self-healing distribution system. To restore the distribution system in a timely and reliable manner, the realistic system operating conditions need to be accurately characterized. Here, two main factors that have great impacts on distribution system restoration (DSR) in practice are investigated. First, cold load pickup (CLPU), generally caused by thermostatically controlled loads (TCLs), is a common phenomenon after an outage and shaped by the outage duration. However, the time-dependent behaviors of CLPU are rarely considered in literature. In this paper, the operating state evolution of TCLs after an outage is analyzed to characterize time-dependent CLPU. And the time-dependent CLPU is analytically embedded in DSR to accurately represent the actual behaviors of the restored loads. Second, it is difficult to predict loads that fluctuate during DSR due to the lack of real-time measurement data. Accordingly, a robust DSR based on the information gap decision theory (IGDT) is proposed to address this challenge, fully considering the uncertainty of CLPU. The proposed models are tested in IEEE 13-node and 123-node test feeders. Simulation results demonstrate that the time-dependent CLPU model and the uncertainty modeling of CLPU can accurately capture the actual behaviors of loads with TCLs after an outage, which greatly improves DSR decisions in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗