Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence limits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-F-T-609: Impact of Dosimetric Variation for Prescription Dose Using Analytical Anisotropic Algorithm (AAA) in Lung SBRT

Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife

Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dose deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy

Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), the cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

Analysis of sampling plan options for tank 16H from the perspective of statistical uncertainty

This report develops a concentration variability model for Tank 16H in order to compare candidate sampling plans for assessing the concentrations of analytes in the residual material in the annulus and on the floor of the primary vessel. A concentration variability model is used to compare candidate sampling plans based on the expected upper 95% confidence limit (UCL95) for the mean. The result is expressed as a rank order of candidate sampling plans from lowest to highest expected UCL95, with the lowest being the most desirable from an uncertainty perspective.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Assessment of LANL-Derived Residual Radionuclides in Soils within C Tracts (C-2, C-3, and C-4) for Land Transfer Decisions

In 2015, soil sampling for radiological materials was conducted within Tract A-16-b specifically for land conveyance decisions. Measurements of radionuclides in soil samples were evaluated against a recreational use scenario, and all measurements were below screening action levels for each radionuclide. The total estimated dose was less than 1 mrem/y (< 10 μSv/y) for a hypothetical recreational user (compared to an action level of 15 mrem/y (150 μSv/y). Dose estimates were based on the 95% upper confidence limits for radionuclide concentrations within the tracts. Additionally, dose estimates less than 3 mrem/y are considered to be As Low As Reasonably Achievable, so no follow-up analysis was conducted. Release of this property is consistent with the requirements of DOE Order 458.1 and Los Alamos National Laboratory Policy 412.

54 ENVIRONMENTAL SCIENCES↗

Technical Report: Algorithm and Implementation for Quasispecies Abundance Inference with Confidence Intervals from Metagenomic Sequence Data

This report describes the design and implementation of an algorithm for estimating relative microbial abundances, together with confidence limits, using data from metagenomic DNA sequencing. For the background behind this project and a detailed discussion of our modeling approach for metagenomic data, we refer the reader to our earlier technical report, dated March 4, 2014. Briefly, we described a fully Bayesian generative model for paired-end sequence read data, incorporating the effects of the relative abundances, the distribution of sequence fragment lengths, fragment position bias, sequencing errors and variations between the sampled genomes and the nearest reference genomes. A distinctive feature of our modeling approach is the use of a Chinese restaurant process (CRP) to describe the selection of genomes to be sampled, and thus the relative abundances. The CRP component is desirable for fitting abundances to reads that may map ambiguously to multiple targets, because it naturally leads to sparse solutions that select the best representative from each set of nearly equivalent genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of Muon Neutrino Disappearance with Non-Fiducial Interactions in the NO$\nu$A Experiment

The NuMI (Neutrinos at the Main Injector) Off-Axis $\nu_e$ Appearance (NO$\nu$A) experiment is a long baseline neutrino oscillation experiment. The experiment measures the oscillations of a primarily muon neutrino beam using two functionally identical liquid scintillator tracking calorimeters detectors placed 810 km apart and 14 milliradians off-axis to the NuMI beam. The oscillation parameters $\sin^2 \theta_{23}$ and $\left | \Delta m^2_{32} \right |$ are measured from the disappearance of muon neutrinos as they propagate between the two detectors using the first data collected in 2014 and 2015. The primary NO$\nu$A analysis uses charged current events only in the fiducial volume of the far detector. This analysis also includes a non-fiducial sample of interactions that originate in the fiducial volume of the far detector but escape the detector. This analysis measures the oscillation parameters as $\sin^2 \theta_{23}$ = 0.31-0.71 and $\left | \Delta m^2_{32} \right |$ = 2. 15-2.91$\times$10$^{-3}$ eV$^2$ at 90\% confidence limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Light Dark Matter Produced in a Proton Beam Dump

Cosmological observations indicate that our universe contains dark matter (DM), yet we have no measurements of its microscopic properties. Whereas the gravitational interaction of DM is well understood, its interaction with the Standard Model is not. Direct detection experiments, the current standard, search for a nuclear recoil interaction and have a low-mass sensitivity edge of order 1 GeV. A path to detect DM with mass below 1 GeV is the use of accelerators producing boosted low-mass DM. Using neutrino detectors to search for low-mass DM is logical due to the similarity of the DM and neutrino signatures in the detector. The MiniBooNE experiment, located at Fermilab on the Booster Neutrino Beamline, has produced the first proton beam-dump light DM search results. Using dark matter scattering from nucleons 90% confidence limits were set over a large parameter space and, to allow tests of other theories, a model independent DM rate was extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity Study for Low Mass Dark Matter Search at DUNE

Many anomalies in the predictions of mass and gravity at the galactic scale have been attributed to an elusive form of matter we refer to as dark matter. The excessive rotational velocity of galaxies and gravitational lensing observed in the cosmos have not found any explanation within the standard model of physics. However, dark matter itself remains undetected as it seems to only interact with gravity. If it does interact with other forces, it has a minuscule cross section similarly to the neutrino particle. Many emerging theories hope to explain the mechanisms of production and interaction of dark matter and many future experiments hope to detect it. It is thought that the detection of dark matter will be more likely by producing boosted dark matter with the use of high energy particle accelerators, and since dark matter is also thought to interact similarly to the neutrino, the use of a neutrino detector also proves to be a good choice. These are all components of the Deep Underground Neutrino Experiment (DUNE) at Fermilab. This paper explores the possibility of detection in the low mass range of light dark matter at DUNE using electron elastic scatter events in the Near detector. We use computer simulations of dark matter and neutrinos produced in the experiment and their signals in the detector to set 90% confidence limits over the light dark matter parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Milestone 1.2.11: H 2 Production from Surrogate Non-Native Corrosion Plumes on Aluminum 6061-T6 Fuel Cladding Surrogates

Thick, localized, “non-native” corrosion plumes have been identified on Advanced Test Reactor fuel elements, raising concern on their impact on the radiolytic formation of molecular hydrogen gas (H 2 ) from aluminum-clad spent nuclear fuel (ASNF) under proposed extended (> 50 years) dry storage conditions. Here, we report our findings on H 2 generation from the gamma irradiation (up to 52 MGy) of surrogate “non-native” corrosion plume coupons: ambient-temperature-corroded (~350 days in water) aluminum alloy 6061 (AA6061) coupons in helium gas environments with ~0% added relative humidity. Additionally, we provide a comparison of proposed ASNF drying techniques— vacuum drying only, vacuum drying + 100 °C for 4 hr, and vacuum drying + 220 °C for 4 hr—on the yield of H 2 from these surrogate systems. The presented data indicates that similar amounts of H 2 (~2 × 10–3 µmol J–1) are formed from gamma irradiated AA6061 coupons corroded under different temperature regimes, i.e., ambient/350 days vs. 90 C/30 days. These findings validate current, complimentary modelling predictions based on high-temperature-corrosion irradiation data only. Further, the application of a heat treatment procedure (100 and 220 °C), in conjunction with vacuum drying, accelerated the rate at which a steady-state H 2 yield was attained, in comparison to vacuum only, due to the removal of H 2 precursors in the form of adsorbed waters. Interestingly, within the confidence limits of our measurements, negligible difference in total H 2 yield was found between the two investigated heat treatment procedures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lack of Transmission of Foot-and-Mouth Disease Virus From Persistently Infected Cattle to Naïve Cattle Under Field Conditions in Vietnam

Foot-and-mouth disease (FMD), caused by FMD virus (FMDV; Aphthovirus, Picornaviridae), is a highly contagious and economically important disease of clovenhoofed domestic livestock and wildlife species worldwide. Subsequent to the clinical phase of FMD, a large proportion of FMDV-infected ruminants become persistently infected carriers, defined by detection of FMDV in oropharyngeal fluid (OPF) samples 28 days or more post-infection. The goal of this prospective study was to characterize the FMD carrier state in cattle subsequent to natural infection under typical husbandry practices in Vietnam. Ten persistently infected cattle on eight farms in the Long An province in southern Vietnam were monitored by monthly screening of serum and oropharyngeal fluid samples for 12 months. To assess transmission from FMDV carriers, 16 naïve cattle were intentionally brought into direct contact with the persistently infected animals for 6 months, and were monitored by clinical and laboratory methods. The restricted mean duration of the FMD carrier state was 27.7 months, and the rate of decrease of the proportion of carrier animals was 0.03 per month. There was no evidence of transmission to naïve animals throughout the study period. Additionally, there was no detection of FMDV infection or seroconversion in three calves born to carrier animals during the study. The force of infection for carrier-to-contact transmission was 0 per month, with upper 95% confidence limit of 0.064 per month. Phylogenetic analysis of viral protein 1 (VP1) coding sequences obtained from carriers indicated that all viruses recovered in this study belonged to the O/ME-SA/PanAsia lineage, and grouped phylogenetically with temporally and geographically related viruses. Analysis of within-host evolution of FMDV, based upon full-length open reading frame sequences recovered from consecutive samples from one animal, indicated that most of the nonsynonymous changes occurred in Lpro, VP2, and VP3 protein coding regions. This study suggests that the duration of FMDV persistent infection in cattle may be longer than previously recognized, but the risk of transmission is low. Additional novel insights are provided into within-host viral evolution under natural conditions in an endemic setting.

59 BASIC BIOLOGICAL SCIENCES↗

Addressing Low-Cost Methane Sensor Calibration Shortcomings with Machine Learning

Quantifying methane emissions is essential for meeting near-term climate goals and is typically carried out using methane concentrations measured downwind of the source. One major source of methane that is important to observe and promptly remediate is fugitive emissions from oil and gas production sites but installing methane sensors at the thousands of sites within a production basin is expensive. In recent years, relatively inexpensive metal oxide sensors have been used to measure methane concentrations at production sites. Current methods used to calibrate metal oxide sensors have been shown to have significant shortcomings, resulting in limited confidence in methane concentrations generated by these sensors. To address this, we investigate using machine learning (ML) to generate a model that converts metal oxide sensor output to methane mixing ratios. To generate test data, two metal oxide sensors, TGS2600 and TGS2611, were collocated with a trace methane analyzer downwind of controlled methane releases. Over the duration of the measurements, the trace gas analyzer’s average methane mixing ratio was 2.40 ppm with a maximum of 147.6 ppm. The average calculated methane mixing ratios for the TGS2600 and TGS2611 using the ML algorithm were 2.42 ppm and 2.40 ppm, with maximum values of 117.5 ppm and 106.3 ppm, respectively. A comparison of histograms generated using the analyzer and metal oxide sensors mixing ratios shows overlap coefficients of 0.95 and 0.94 for the TGS2600 and TGS2611, respectively. Overall, our results showed there was a good agreement between the ML-derived metal oxide sensors’ mixing ratios and those generated using the more accurate trace gas analyzer. This suggests that the response of lower-cost sensors calibrated using ML could be used to generate mixing ratios with precision and accuracy comparable to higher priced trace methane analyzers. This would improve confidence in low-cost sensors’ response, reduce the cost of sensor deployment, and allow for timely and accurate tracking of methane emissions.

03 NATURAL GAS↗

DETAILED ANALYSIS OF NEAR-IR WATER (H{sub 2}O) EMISSION IN COMET C/2014 Q2 (LOVEJOY) WITH THE GIANO/TNG SPECTROGRAPH

We observed the Oort cloud comet C/2014 Q2 (Lovejoy) on 2015 January 31 and February 1 and 2 at a heliocentric distance of 1.3 au and geocentric distance of 0.8 au during its approach to the Sun. Comet Lovejoy was observed with GIANO, the near-infrared high-resolution spectrograph mounted at the Nasmyth-A focus of the TNG (Telescopio Nazionale Galileo) telescope in La Palma, Canary Islands, Spain. We detected strong emissions of radical CN and water, along with many emission features of unidentified origin, across the 1–2.5 μ m region. Spectral lines from eight ro-vibrational bands of H{sub 2}O were detected, six of them for the first time. We quantified the water production rate [ Q (H{sub 2}O), (3.11 ± 0.14) × 10{sup 29} s{sup −1}] by comparing the calibrated line fluxes with the Goddard full non-resonance cascade fluorescence model for H{sub 2}O. The production rates of ortho-water [ Q (H{sub 2}O){sup ORTHO}, (2.33 ± 0.11) × 10{sup 29} s{sup −1}] and para-water [ Q (H{sub 2}O){sup PARA}, (0.87 ± 0.21) × 1029 s{sup −1}] provide a measure of the ortho-to-para ratio (2.70 ± 0.76)). The confidence limits are not small enough to provide a critical test of the nuclear spin temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

GRS 1739-278 observed at very low luminosity with XMM-Newton and NuSTAR

We present a detailed spectral analysis of XMM-Newton and NuSTAR observations of the accreting transient black hole GRS 1739−278 during a very faint low hard state at ∼0.02% of the Eddington luminosity (for a distance of 8.5 kpc and a mass of 10 M{sub ⊙}). The broadband X-ray spectrum between 0.5 and 60 keV can be well-described by a power-law continuum with an exponential cutoff. The continuum is unusually hard for such a low luminosity, with a photon index of Γ = 1.39 ± 0.04. We find evidence for an additional reflection component from an optically thick accretion disk at the 98% likelihood level. The reflection fraction is low, with R{sub refl}=0.043{sub −0.023}{sup +0.033}. In combination with measurements of the spin and inclination parameters made with NuSTAR during a brighter hard state by Miller et al., we seek to constrain the accretion disk geometry. Depending on the assumed emissivity profile of the accretion disk, we find a truncation radius of 15–35 R{sub g} (5–12 R{sub ISCO}) at the 90% confidence limit. These values depend strongly on the assumptions and we discuss possible systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Logamediate Inflation in f ( T ) Teleparallel Gravity

We study logamediate inflation in the context of f ( T ) teleparallel gravity. f ( T )-gravity is a generalization of the teleparallel gravity which is formulated on the Weitzenbock spacetime, characterized by the vanishing curvature tensor (absolute parallelism) and the non-vanishing torsion tensor. We consider an f ( T )-gravity model which is sourced by a canonical scalar field. Assuming a power-law f ( T ) function in the action, we investigate an inflationary universe with a logamediate scale factor. Our results show that, although logamediate inflation is completely ruled out by observational data in the standard inflationary scenario based on Einstein gravity, it can be compatible with the 68% confidence limit joint region of Planck 2015 TT,TE,EE+lowP data in the framework of f ( T )-gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for Gamma-Ray Emission from Local Primordial Black Holes with the Fermi Large Area Telescope

Black holes with masses below approximately 10 15 g are expected to emit gamma-rays with energies above a few tens of MeV, which can be detected by the Fermi Large Area Telescope (LAT). Although black holes with these masses cannot be formed as a result of stellar evolution, they may have formed in the early universe and are therefore called primordial black holes (PBHs). Previous searches for PBHs have focused on either short-timescale bursts or the contribution of PBHs to the isotropic gamma-ray emission. We show that, in cases of individual PBHs, the Fermi-LAT is most sensitive to PBHs with temperatures above approximately 16 GeV and masses 6 × 10 11 g, which it can detect out to a distance of about 0.03 pc. These PBHs have a remaining lifetime of months to years at the start of the Fermi mission. They would appear as potentially moving point sources with gamma-ray emission that become spectrally harder and brighter with time until the PBH completely evaporates. In this paper, we develop a new algorithm to detect the proper motion of gamma-ray point sources, and apply it to 318 unassociated point sources at a high galactic latitude in the third Fermi-LAT source catalog. None of the unassociated point sources with spectra consistent with PBH evaporation show significant proper motion. Finally, using the nondetection of PBH candidates, we derive a 99% confidence limit on the PBH evaporation rate in the vicinity of Earth, ${\dot{\rho }}_{\mathrm{PBH}}\lt 7.2\times {10}^{3}\ {\mathrm{pc}}^{-3}\,{\mathrm{yr}}^{-1}$. This limit is similar to the limits obtained with ground-based gamma-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Association between the Candidate Repeating FRB 20200320A and a Galaxy Group

Abstract We present results from angular cross correlations between select samples of CHIME/FRB repeaters and galaxies in three photometric galaxy surveys, which have shown correlations with the first CHIME/FRB catalog containing repeating and nonrepeating sources: Wide-field Infrared Survey Explorer (WISE) × SCOS, DESI-BGS, and DESI-LRG. We find a statistically significant correlation (p-value <0.001, after accounting for look-elsewhere factors) between a sample of repeaters with an extragalactic dispersion measure (DM) > 395 pc cm −3 and WISE × SCOS galaxies with redshiftz> 0.275. We demonstrate that the correlation arises surprisingly because of a statistical association between FRB 20200320A (extragalactic DM ≈ 550 pc cm −3 ) and a galaxy group in the same dark matter halo at redshiftz≈ 0.32. We estimate that the host halo, along with an intervening halo at redshiftz≈ 0.12, accounts for at least ∼30% of the extragalactic DM. Our results strongly motivate incorporating galaxy group and cluster catalogs into direct host association pipelines for FRBs with ≲ 1 ′ localization precision, effectively utilizing the two-point information to constrain FRB properties such as their redshift and DM distributions. In addition, we find marginal evidence for a negative correlation at 99.4% confidence limit between a sample of repeating FRBs with baseband data (median extragalactic DM = 354 pc cm −3 ) and DESI-LRG galaxies with redshift 0.3 ≤z< 0.45, suggesting that the repeaters might be more prone than apparent nonrepeaters to propagation effects in FRB–galaxy correlations due to intervening free electrons over angular scales ∼0.°5.

Astronomy & Astrophysics↗

Ice-nucleating particles (INPs) concentrations from SAIL-Net

This data set contains ice-nucleating particle (INP) concentration spectra collected during the SAIL-Net sampling period, which complemented the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign in the East River watershed near Crested Butte, Colorado. SAIL-Net was a distributed aerosol measurement network designed to investigate aerosol variability across complex mountainous terrain. The data set includes samples from multiple SAIL-Net sites, including AOS, Gothic, Snodgrass, Pumphouse, Irwin, and Top. INP concentrations are reported as a function of freezing temperature, together with confidence limits, sampling times, site location, elevation, sampled air volume, and treatment information. These data provide an analysis-ready record of the INPs across the SAIL-Net network.

activation temperature↗