Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conditional thermal state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of a Computational Framework for Multiphysics Multiphase Species Tracking using NEAMS Tools

This report implements a high-fidelity multiphysics modeling framework using the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program tools to track isotopic species in Molten Salt Reactors (MSRs), with a specific focus on the 91-depletion chain within the Molten Salt Reactor Experiment (MSRE). The model integrates neutronics, thermal-hydraulics, depletion, and thermochemistry to simulate the production, transport, and phase transitions of isotopes under steady-state and transient conditions. The main findings reveal that isotopes such as bromine-91 largely remain in the liquid phase, while others, including krypton-91and yttrium-91, transition to the gas phase, significantly influencing the reactor’s radiological source term. The study also shows that during transients, like a reactivity insertion transient, rapid void formation and the expansion of the liquid-gas interface led to substantial transfers of dissolved isotopes into the gas phase, altering isotope distribution and largely increasing the source term in the off-gas system. Additionally, the research highlights that short-lived isotopes dominate the initial off-gas response during transients, while longer-lived isotopes determine the equilibrium state, underscoring the necessity of dynamic simulations for accurate species tracking and reactor safety analysis. The developed methodology will be applied in the future to the tracking of a larger number of species and introduce other species tracking mechanisms, such as deposition and plating.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Margin to onset of nucleate boiling and flow instability studies for preliminary MITR design-demonstration element thermal-hydraulics

This study covers the onset of flow instability (OFI) preliminary results obtained from leveraging correlations, in addition to the preliminary thermal hydraulics results such as pressure, flow velocity, temperature, and oxide layer over the design demonstration experiment (DDE) for the Massachusetts Institute of Technology Reactor (MITR). Current computational fluid dynamics (CFD) models in fluid structure interaction (FSI) have added the capability of assessing margins to onset of nucleate boiling (ONB). This study initiates the capability to model the margin to OFI and ONB presented for the MITR. Such study is supportive of the United States High Performance Research Reactor (USHPRR) program. Previous studies provided preliminary thermal-hydraulic and mechanical analyses of the hydrodynamic effects in the MITR DDE under conservative approximations for plate power distribution. In conclusion, this study focuses on providing insights into the OFI future research direction optimizing the transport of thermal energy, mass-flow rates, flow-channel geometries, and boundary conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal exchange-correlation functionals: Capturing quantum electron behavior in warm, dense plasmas

We summarize and give perspective upon recent progress in developing non-empirical constraint-based thermal (i.e., free energy) exchange-correlation (XC) density functionals essential for accurate description of the quantum behavior of electrons in warm, dense plasmas. After delineating the critical role of ground-state functionals for zero-temperature, time-dependent DFT, we outline the underpinnings of local density approximation, generalized gradient approximation (GGA), and meta-GGA XC free-energy functionals. Two basic thermalization principles for upgrading ground-state XC functionals to successful thermal ones are emphasized. Then, we turn to a long-standing challenge, assessment of the accuracy of well-founded functionals. Unlike the ground state, there are a few exact results for large T and P. An exception is path integral Monte Carlo (PIMC) data for dense H/D and He plasmas. For those, we did ab initio molecular dynamics simulations under selected thermodynamic conditions employing five thermal XC functionals: two approximate thermal GGAs, fully thermal GGA, an approximate meta-GGA, and fully thermal meta-GGA. Comparisons with the PIMC data show that functionals thermalized by augmenting a non-thermal functional with a lower-level thermal contribution are inferior to functionals with thermal XC and spatial inhomogeneity effects taken into account at the same level of refinement. We believe this and similar evidence should be convincing to the high-energy density physics community of the necessity of use of proper thermal XC functionals in simulation studies of finite-temperature quantum effects in warm, dense plasmas.

Ab-initio molecular dynamics↗

Insight into the deformation features and capacity loss mechanisms of lithium-ion pouch cells under spherical indentation conditions

Mechanical deformation under extreme conditions is one of the important reasons for the failure of lithium-ion batteries in automotive application. However, the deformation features and component failure of lithium-ion cells to external loading has never been a design consideration. Here, in this study, we conduct spherical indentation tests on a dozen of lithium-ion cells with different capacities under different control mode conditions to investigate their deformation features and capacity loss mechanisms. The experimental results show that, under mechanical deformation conditions, internal faults of cells occur in stages, and energy accumulation and sudden release are two key processes of cell's mechanical failure. The cells' state of charge is the main factor affecting their thermal runaway behaviors. In addition, a finite element model is developed to simulate the deformation features and the failure mechanism of key components of lithium-ion pouch cells; the 3D x-ray computed tomography is employed to demonstrate its internal configuration. With this model, the force-strain response, the deformation features as well as the size of the failure area of lithium-ion cells under spherical indentation conditions are accurately predicted. In 3D x-ray computed tomography images, unique mud cracks in cooper current collector are observed, and the influence mechanisms of the isolated fragments on the cell capacities are revealed. These results may provide useful information for the mechanical structure design of the components of lithium-ion pouch cells.

25 ENERGY STORAGE↗

Correlating Nb-SRF Surface Processing with Evolution of Surface Electronic States

The few nanometers of the surface exposed to RF field plays a major role in defining the RF performance of superconducting cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in cavity performance by simultaneously achieving high Q with increasing Eacc. These processing methods include: thermal treatment under ultra-high vacuum (UHV) conditions across lo¬¬¬¬¬¬¬w-, mid-, and high-temperature ranges and high temperature treatments under controlled N2 atmosphere. These processes also produce distinct surface oxide configurations with different valence states, thicknesses, and uniformity, as well as different oxygen concentration profiles in bulk Nb. In this work, we are trying to understand how do surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity? With the help of Fermilab’s in-house X-ray photoemission facility and, in collaboration with the synchrotron-based angle-resolved photoemission (ARPES) facility at Argonne National Laboratory, we are investigating how the valence band structure and density of states (DoS) near the Fermi level modify with different surface treatments. Our observations show that different surface-processing methods lead to distinct evolutions of the valence-band states near the Fermi level during the superconducting transition. This behavior suggests variations in Nb-O orbital hybridizations and points towards the possibility of different underlying mechanisms of superconductivity governed by the surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in SRF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of SRF cavities.

Tripathi, Malvika [Fermilab]↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for Concentrating Solar Receiver Applications

Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.

14 SOLAR ENERGY↗

Insights into Methodologies and Stochastic Optimization of Thermal Energy Storage-Coupled Advanced Reactor Systems: A Comparison of Methods for Accessing Long-Term Sub-System Sizing Adequacy

This paper investigates the potential of coupling Thermal Energy Storage (TES) with Advanced Reactors (ARs) to address uncertainties posed by climate change in deep decarbonized power systems. The TES Use-case Team at Idaho National Laboratory (INL) has examined the potential of storing thermal energy from ARs during low demand periods and optimizing discharge during peak-priced hours, in both steady-state and transient conditions. Building on this groundwork, this study bridges the gaps in optimal sizing of the sub-system of TES-coupled AR systems using Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON), INL?s framework for grid optimization. By applying this framework, we present statistically-robust optimal charge, discharge including balance of plant (BOP), and storage sizing for the High-Temperature Gas-Cooled Reactor (HTGR) with 203 MWth output. To this end, we generated synthetic price samples for 30 years using 2018 ? 2021 real-time market data from ERCOT, PJM and MISO. Our results reveals that the TES-coupled HTGR system is highly effective in maximizing revenue from electricity sales. We observed a substantial increase of 40 % in ERCOT and a noteworthy 15 % increase in PJM and MISO when compared to the conventional BOP without TES. This improvement is achieved through regionally-tailored sub-system sizing, which ranges from 398 to 416 MWth for the discharge system and 610 to 1029 MWth for the TES. We find that the average electricity price directly impacts the overall economics, while price volatility influences storage size. Additional sensitivity analyses were performed to access the impact of key assumptions on system economics and sizing, differentiating the optimization window (i.e., 24 ? 219 hours of chronological observations) and by imposing storage continuity condition in tracking TES cycles. We observed that at the 120-hour of the optimization window, a reasonable balance between computation time and accuracy was achieved. Our analysis also highlights the significance of conducting multi-day cycle analysis (> 120-hour) for TES to capture interaction between electricity prices and storage dynamics, providing a comprehensive understanding of TES behavior that AR developers should integrate into their plant designs.

25 ENERGY STORAGE↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utah FORGE 5-2565: Evolution of Permeability and Strength Recovery of Shear Fractures Under Hydrothermal Conditions - 2024 Annual Workshop Presentation

This is a presentation on the Evolution of Permeability and Strength Recovery of Shear Fractures Under Hydrothermal Conditions by United States Geological Survey, presented by Tamara Jeppson. This video slide presentation, by the USGS, discusses the determination of how thermal, hydrologic, mechanical, and chemical (THMC) processes affect the sustainability of fracture networks in geothermal reservoirs. This includes (1) the qualification of rates of change of fracture properties, (2) the parameterization of modes of reaction, (3) the development of micromechanical and empirical fracture models, and (4) extended THMC models for laboratory- and reservoir-scale models. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 15, 2024.

15 GEOTHERMAL ENERGY↗

COMSOL Results for the Nominal Steady-State Operation of the Proposed 95-MW LEU Silicide Core for HFIR Conversion

Engineering design studies are being performed to determine the feasibility of converting the High Flux Isotope Reactor (HFIR) from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel at Oak Ridge National Laboratory. This activity is sponsored by the Office of Reactor Conversion and Uranium Supply (ORCUS) under the auspices of the US Department of Energy National Nuclear Security Administration’s Office of Material Management and Minimization. HFIR is a very high flux, pressurized, light water–cooled and moderated, flux trap–type research reactor with a core made of involute shaped U 3 O 8 /Al cermet fuel plates and coolant channels. HFIR currently operates at a thermal power of 85 MW and supports key national and international missions in neutron scattering, isotope production, materials/fuels irradiation, neutron activation analysis, gamma irradiation, and neutrino research. Advanced multiphysics computational fluid dynamics models have been developed in the COMSOL Multiphysics software to simulate the steady-state operating conditions for the proposed low-and high-density LEU U 3 Si 2 -Al (uranium silicide dispersion) fuel designs. The COMSOL models for HFIR inner and outer fuel element models incorporate various essential inputs and physics such as spatially dependent nuclear heat deposition, multilayer heat conduction, conjugate heat transfer, turbulent flows (using Reynolds-averaged Navier Stokes turbulence models), structural mechanics (thermal–structural interactions and fuel swelling), and oxide layer build-up. This report presents the best-estimate thermal hydraulics results for the low- and high-density optimized silicide LEU core designs at 95 MW steady-state nominal operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Island for gravitationally prepared state and pseudo entanglement wedge

We consider spacetime initiated by a finite-sized initial boundary as a generalization of the Hartle-Hawking no-boundary state. We study entanglement entropy of matter state prepared by such spacetime. We find that the entanglement entropy for large subregion is given either by the initial state entanglement or the entanglement island, preventing the entropy to grow arbitrarily large. Consequently, the entanglement entropy is always bounded from above by the boundary area of the island, leading to an entropy bound in terms of the island. The island I is located in the analytically continued spacetime, either at the bra or the ket part of the spacetime in Schwinger-Keldysh formalism. The entanglement entropy is given by an average of complex pseudo generalized entropy for each entanglement island. We find a necessary condition of the initial state to be consistent with the strong sub-additivity, which requires that any probe degrees of freedom are thermally entangled with the rest of the system. We then find a large parameter region where the spacetime with finite-sized initial boundary, which does not have the factorization puzzle at leading order, dominates over the Hartle-Hawking no-boundary state or the bra ket wormhole. Due to the absence of a moment of time reflection symmetry, the island in our setup is a generalization of the entanglement wedge, called pseudo entanglement wedge. In pseudo entanglement wedge reconstruction, we consider reconstructing the bulk matter transition matrix on A ∪ I, from a fine-grained state on A. The bulk transition matrix is given by a thermofield double state with a projection by the initial state. We also provide an AdS/BCFT model by considering EOW branes with corners. We also find the exponential hardness of such reconstruction task using a generalization of Python’s lunch conjecture to pseudo generalized entropy.

2D gravity↗

Chiral edge state control of thermoelectric effects

Thermoelectric responses in two-dimensional electron gases subjected to magnetic fields have the potential to provide unique information about quasiparticle statistics. In this study, we show that chiral edge states play a key role in thermoelectric Hall bar measurements by completely controlling the direction of the internal thermal gradient. To this end, we perform measurements of the magnetothermoelectric responses of cadmium arsenide quantum wells. The magnetothermoelectric responses in the quantum Hall regime agree with theoretical predictions if one considers the role of chiral edge states, which flow in opposite directions on either side of the Hall bar and establish an internal temperature gradient that is perpendicular to the externally applied thermal gradient. We show that the results are self-consistent within this picture under different measurement conditions. We discuss potential applications of the findings, such as in nanoscale control of local temperature gradients and thermoelectric effects along with the characterization of other topological systems with chiral edges states.

Science & Technology - Other Topics↗

Solvation Environment and Interface Dynamics of Li 2 B 12 H 12 and Li 2 B 12 F 12 Electrolytes Uncovered by Theory and Operando Optical and FTIR Spectroelectrochemistry

In this work, we evaluated two closo-borate salts (Li 2 B 12 H 12 and Li 2 B 12 F 12 ) in propylene carbonate from theoretical and experimental perspectives to understand how the coordination environment influences their spectroscopic and electrochemical properties. The coordination environments of the closo-borate salts were modeled via density functional theory (DFT) and molecular dynamics (MD). Vibrational spectra calculated from the predicted coordination environments are in agreement with experimentally measured steady-state FTIR data. This theoretical investigation also suggested that Li 2 B 12 F 12 would possess a higher ionic conductivity than Li 2 B 12 H 12 , which was corroborated experimentally. Additionally, an electrochemical cell was designed and fabricated that enabled operando optical and FTIR spectroelectrochemical (OP-IR-SEC) measurements. This allowed for the simultaneous measurement of the relative changes of species at a lithium electrode-liquid electrolyte interface and the visualization of lithium plating at the electrode surface. This technique could provide new chemical insights and potentially link optical changes at the electrode–electrolyte interface to specific chemical species in similar electrochemical systems. The Li 2 B 12 F 12 electrolyte was found to have a higher thermal stability, which may find utility in applications for batteries that are subject to high-temperature conditions.

36 MATERIALS SCIENCE↗

Nanocluster Active Sites Formed on Heterogeneous Thermal Catalysts and Electrocatalysts by Operando Reactive Environments

Here, in this Viewpoint, we summarize our recent studies in this endeavor, ending with a forward-looking perspective into the remaining challenges and open questions for consideration by the catalysis community. Through a computationally efficient framework of systematically investigating metal atom ejection from and migration onto metal surfaces, leading to the formation of metal atom clusters, we show that the surface of a metal catalyst is dynamic and much less rigid than previously thought. We suggest that the operando formed metal atom clusters are novel active sites, which can dominate the activity of steps or kinks (let aside terraces) from where their constituent atoms were ejected. Through more readily responding to reaction conditions by forming catalytically active clusters, solid metal catalysts approach not only homogeneous catalyst motifs, thus establishing a bridge between homogeneous and heterogeneous catalysis, but also liquid metals which have been suggested to be better than traditional heterogeneous catalysts.

adsorption↗

NeuroSEM: A hybrid framework for simulating multiphysics problems by coupling PINNs and spectral elements

Multiphysics problems that are characterized by complex interactions among fluid dynamics, heat transfer, structural mechanics, and electromagnetics, are inherently challenging due to their coupled nature. While experimental data on certain state variables may be available, integrating these data with numerical solvers remains a significant challenge. Physics-informed neural networks (PINNs) have shown promising results in various engineering disciplines, particularly in handling noisy data and solving inverse problems in partial differential equations (PDEs). However, their effectiveness in forecasting nonlinear phenomena in multiphysics regimes, particularly involving turbulence, is yet to be fully established. Here, this study introduces NeuroSEM, a hybrid framework integrating PINNs with the highfidelity Spectral Element Method (SEM) solver, Nektar++. NeuroSEM leverages the strengths of both PINNs and SEM, providing robust solutions for multiphysics problems. PINNs are trained to assimilate data and model physical phenomena in specific subdomains, which are then integrated into the Nektar++ solver. We demonstrate the efficiency and accuracy of NeuroSEM for thermal convection in cavity flow and flow past a cylinder. The framework effectively handles data assimilation by addressing those subdomains and state variables where the data is available. We applied NeuroSEM to the Rayleigh-B´enard convection system, including cases with missing thermal boundary conditions and noisy datasets. Finally, we applied the proposed NeuroSEM framework to real particle image velocimetry (PIV) data to capture flow patterns characterized by horseshoe vortical structures. Our results indicate that NeuroSEM accurately models the physical phenomena and assimilates the data within the specified subdomains. The framework’s plug-and-play nature facilitates its extension to other multiphysics or multiscale problems. Furthermore, NeuroSEM is optimized for efficient execution on emerging integrated GPU-CPU architectures. This hybrid approach enhances the accuracy and efficiency of simulations, making it a powerful tool for tackling complex engineering challenges in various scientific domains.

42 ENGINEERING↗

Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) for studying materials and processes under extreme conditions

Externally heated diamond anvil cells provide a stable and uniform thermal environment, making them a versatile device to simultaneously generate high-pressure and high-temperature conditions in various fields of research, such as condensed matter physics, materials science, chemistry, and geosciences. The present study features the Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) system, a versatile configuration consisting of a diamond anvil cell with a customized microheater for stable resistive heating, bidirectional pressure control facilitated by compression and decompression membranes, and a water-cooled enclosure suitable for vacuum and controlled atmospheres. This integrated system excels with its precise control of both pressure and temperature for mineral and materials science research under extreme conditions. Here, we showcase the capabilities of the system through its successful application in the investigation of the melting temperature and thermal equation of state of high-pressure ice-VII at temperatures up to 1400 K. The system was also used to measure the elastic properties of solid ice-VII and liquid H 2 O using Brillouin scattering and Raman spectra of carbonates using Raman spectroscopy, highlighting the potential of the EH-DANCE system in high-pressure research.

Instruments & Instrumentation↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗