Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Dispersion Loss Counteracts Embedding Condensation and Improves Generalization in Small Language Models

Large language models (LLMs) achieve remarkable performance through ever-increasing parameter counts, but scaling incurs steep computational costs. To better understand LLM scaling, we study representational differences between LLMs and their smaller counterparts, with the goal of replicating the representational qualities of larger models in smaller models. We observe a geometric phenomenon which we term embedding condensation, where token embeddings collapse into a narrow cone-like subspace in some language models. Through systematic analyses across multiple Transformer families, we show that small models such as GPT2 and Qwen3-0.6B exhibit severe condensation, whereas larger models such as GPT2-x1 and Qwen3-32B are more resistant to this phenomenon. Additional observations show that embedding condensation is not reliably mitigated by knowledge distillation from larger models. To fight against it, we formulate a dispersion loss that explicitly encourages embedding dispersion during training. Experiments demonstrate that it mitigates condensation, recovers dispersion patterns seen in larger models, and yields performance gains across 10 benchmarks. We believe this work offers a principled path toward improving smaller Transformers without additional parameters.

Xiao, Xi [ORNL] (ORCID:0009000009316982)↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nanostructured $\mathrm{GaAs/(Al,Ga)As}$ Waveguide for Low-Density Polariton Condensation from a Bound State in the Continuum

Exciton-polaritons are hybrid light-matter states that arise from strong coupling between an exciton resonance and a photonic cavity mode. As bosonic excitations, they can undergo a phase transition to a condensed state that can emit coherent light without a population inversion. This aspect makes them good candidates for thresholdless lasers, yet short exciton-polariton lifetime has made it difficult to achieve condensation at very low power densities. In this sense, long-lived symmetry-protected states are excellent candidates to overcome the limitations that arise from the finite mirror reflectivity of monolithic microcavities. In this work we use a photonic symmetry-protected bound state in the continuum coupled to an excitonic resonance to achieve state-of-the-art polariton condensation threshold in a GaAs/(Al,Ga)As waveguide. Most important, we show the influence of fabrication control and how surface passivation via atomic layer deposition provides a way to reduce exciton quenching at the grating sidewalls.

74 ATOMIC AND MOLECULAR PHYSICS↗

Furfural Upgrading by Aldol Condensation with Ketones over Solid-Base Catalysts

Aldol condensation reactions between furfural and various ketones were studied in a flow reactor at 373 K and 100 psi for application to upgrading of furfural. Specific rates for the reaction of acetone and furfural were measured on MgAl 2 O 4 , Al 2 O 3 , CaO/MgAl 2 O 4 and MgO/MgAl 2 O 4 and found to be highest on CaO/MgAl 2 O 4 . While the presence of CO 2 and H 2 O did not affect the stability of the CaO/MgAl 2 O 4 catalyst, the catalyst deactivated over a period of a few hours due to the production of 2-furoic acid formed by the Cannizzaro reaction. While aldol condensation rates between furfural and either 2-pentanone and decanal approached that of acetone, rates for 4-heptanone and 2,5-heptanedione were significantly lower because the α-hydrogens of the carbonyl compounds are less easily attacked in these molecules. The selectivity to aldol products is affected by the relative rates of the aldol-condensation and the Cannizzaro reactions. Possible strategies for maximizing production of the aldol products with larger ketones are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Porous condensers can double the efficiency of membrane distillation

Among membrane distillation (MD) configurations, air gap MD (AGMD) has superior energy efficiency at high salinity. However, flooding of the gap prevents optimal thin gap depths as water removal is a challenge. To address these challenges, this work provides the first analysis of efficiency enhancement via porous wicking conductive condensers in MD. To do so, we examined performance with experiments and comprehensive thermo-fluid numerical models; we find that the porous wick condenser significantly improves thermal efficiency, gain output ratio (GOR), and flux. MD experiments show that the porous copper foam improves the thermal efficiency of air gap membrane distillation up to 40 % and water flux up to 144 %. Numerical modeling shows the porous copper foam improves the GOR of membrane distillation in high salinity by 98.7 %, outperforming air gap MD, permeate gap MD, and conductive gap MD. Furthermore, the optimized thickness and permeability of porous condensers significantly help eliminate the risk of flooding in AGMD.

42 ENGINEERING↗

Modeling and experimental validation of direct contact crossflow packed beds condenser used in HDH desalination systems

Humidification and dehumidification (HDH) desalination systems are alternatives to reverse osmosis desalination systems, especially for high salinity waters. A HDH system is essentially equipped with a humidifier (also called as evaporator) for air to pick up vapor from saline water, a dehumidifier (also called as condenser) to produce freshwater, and a heating source. HDH systems based on direct contact packed beds heat exchangers have remarkably lower costs than traditional HDH systems due to their inexpensive materials and simple configurations. This paper specifically focuses on direct contact crossflow packed beds condensers, in which cooling water vertically drips through the packed beds, directly contacting the horizontal air-vapor flow. A two-dimensional mathematical model that solves for the enthalpy values of the working fluids is proposed in this paper, and the PDEs are solved using finite differences. To validate the model, an experimental condenser was built and tested. Water temperatures inside the test section at twenty-nine locations were measured, as well as the air vapor temperatures of five locations at the outlet. The measured water and air-vapor temperatures agree with the simulation results with less than 10 % error in most of the compared domain.

42 ENGINEERING↗

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In Tube Condensation Heat Transfer and Pressure Drop for R454B and R32—Potential Replacements for R410A

The heating, ventilation and air conditioning (HVAC) industry in the United States seeks near-term alternative refrigerants to replace R-410A in unitary equipment. Two potential replacement refrigerants are R-454B and R-32. It is of interest to investigate the capability and accuracy of existing heat exchanger design methods when applied to these replacement refrigerants. To that end, this work presents empirical condensation quasi-local heat transfer coefficient and pressure drop data for R-454B and R-32. These data were obtained in a $\frac{3}{8}$ in. (9.52 mm) outside diameter (OD) smooth copper tube with a wall thickness of 0.032 in. (0.81 mm). The experimental variables and their ranges included refrigerant absolute pressure ( 1960 ≤ P a b s ≤ 3196 kPa), condensation temperature ( 35 ≤ T c o n d ≤ 50 °C), mass flux ( 100 ≤ G ≤ 200 kg m -2 s -1 ), vapor quality ( 0 ≤ x ≤ 1 ), and heat flux ( 32.9 ≤ q ″ ≤ 62.97 kW m -2 ). It was found that the heat transfer correlation developed by Cavallini et al. Cavallini et al. (2006) predicted the experimental condensation heat transfer data, for both R-454B and R-32, with the greatest accuracy. Using the Cavallini et al. correlation, it was found that the mean absolute percentage error (MAPE) was 10.5% and 15.1% for R-454B and R-32, respectively. Additionally, the pressure drop correlation developed by Friedel Friedel (1979) predicted the experimentally determined pressure gradient with a MAPE of 7.7% and 5.5% for R-454B and R-32, respectively. These results will assist the practicing thermal engineer to choose the most appropriate design correlation for these near-term replacement refrigerants.

42 ENGINEERING↗

Cross-aldol condensation on missing linker sites of metal–organic framework UiO-66

Missing linkers induce coordinatively unsaturated Lewis acid-base pair sites in metal–organic frameworks such as UiO-66 (Zr). The Lewis acid-base pair is induced by replacing the benzene dicarboxylic acid linker with formic acid, which subsequently is thermally decomposed. The concentration of coordinatively unsaturated Zr 4+ cations was titrated with acetone. In parallel to their concentration, the catalytic activity increased while the selectivity for aldol condensation between furfural and acetone remained constant. The missing linkers generate a complex ensemble consisting of an (at least partly) accessible Zr 4+ cation surrounded by oxygen, catalyzing the cross-aldol condensation. As a result, density functional theory calculations, matching the experimental findings provide a more detailed understanding of the elementary steps during the condensation reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Freeze range of a condensing gas propagating in a liquid helium-cooled tube

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is crucial for maintaining the operational safety of these facilities. Previous experimental investigations on nitrogen gas propagation in both normal liquid helium (He I) and superfluid helium (He II) cooled copper tubes unveiled a nearly exponential deceleration of the gas propagation. A comprehensive theoretical model incorporating gas dynamics, heat transfer, and condensation mechanisms has been developed, which effectively reproduces various key experimental observations. An intriguing phenomenon uncovered in our model simulation is that the gas propagation appears to nearly stop beyond a certain distance from the location where condensation starts. We refer to this distance as the freeze range. In this paper, we present our systematic study of the freeze range at various inlet mass fluxes and tube diameters. We show that the results can be well described by a simple correlation. The underlying physical mechanism that supports this useful correlation is explained. Knowing the freeze range may allow accelerator engineers to develop protocols for controlling frost-layer contamination in the beamline tubes, which is of great practical importance.

43 PARTICLE ACCELERATORS↗

Bose–Einstein condensation of a two-magnon bound state in a spin-1 triangular lattice

In ordered magnets, the elementary excitations are spin waves (magnons), which obey Bose–Einstein statistics. Similarly to Cooper pairs in superconductors, magnons can be paired into bound states under attractive interactions. The Zeeman coupling to a magnetic field is able to tune the particle density through a quantum critical point, beyond which a ‘hidden order’ is predicted to exist. Here, in this work, we report direct observation of the Bose–Einstein condensation of the two-magnon bound state in Na 2 BaNi(PO 4 ) 2 . Comprehensive thermodynamic measurements confirmed the two-dimensional Bose–Einstein condensation quantum critical point at the saturation field. Inelastic neutron scattering experiments were performed to establish the microscopic model. An exact solution revealed stable two-magnon bound states that were further confirmed by electron spin resonance and nuclear magnetic resonance experiments, demonstrating that the quantum critical point is due to the pair condensation, and the phase below the saturation field is likely the long-sought-after spin nematic phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superradiant Neutrino Lasers from Radioactive Condensates

Superradiance emerges from collective spontaneous emission in optically pumped gases, and is characterized by photon emission enhancements of up to $\frac{1}{4}$⁢𝑁 2 in an 𝑁 atom system. The gain mechanism derives from correlations developed within the decay medium rather than from stimulated emission as in lasing, so an analog of this process should be possible for fermionic final states. We introduce here the concept of superradiant neutrino emission from a radioactive Bose Einstein condensate, which can form the basis for a superradiant neutrino laser. A plausible experimental realization based on a condensate of electron-capture isotope 83 Rb could exhibit effective radioactive decay rates accelerated from 86.2 days to minutes in viably sized rubidium condensates of 10 6 atoms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scissors modes of a Bose-Einstein condensate in a synthetic magnetic field

We study the scissors modes of a harmonically trapped Bose-Einstein condensate under the influence of a synthetic magnetic field, which induces rigid rotational components in the velocity field. Our investigation reveals that the scissors mode, excited in the plane perpendicular to the synthetic magnetic field, becomes coupled to the quadrupole modes of the condensate, giving rise to typical beating effects. Moreover, the two scissors modes excited in the vertical planes are also coupled together by the synthetic magnetic field, resulting in intriguing gyroscope dynamics. Our analytical results, derived from a spinor hydrodynamic theory, are further validated through numerical simulations of the three-dimensional Gross-Pitaevskii equation. These predictions for the condensates subject to a synthetic magnetic field are experimentally accessible with current cold-atom setups and hold promise for potential applications in quantum sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulating cosmological evolution by quantum quench of an atomic Bose-Einstein condensate

In cosmological evolution, it is the homogeneous scalar field (inflaton) that drives the universe to expand isotropically and to generate standard model particles. However, to simulate cosmology, atomic gas research has focused on the dynamics of Bose-Einstein condensates (BEC) with continuously applied forces. In this paper we argue that a complementary approach needs also to be pursued; we thus consider the analog BEC experiments in a nondriven and naturally closed atomic system. We implement this using a BEC in an optical lattice which, after a quench, freely transitions from an unstable to a stable state. Furthermore, this dynamical evolution displays the counterpart “preheating,” “reheating,” and “thermalization” phases of cosmology. Importantly, our studies of these analog processes yield tractable analytic models. Additionally, of great utility to the cold atom community, such understanding elucidates the dynamics of nonadiabatic condensate preparation. Indeed, the dynamical processes discussed here are generic and in future cold atom reequilibration experiments it will be important to observe both the preheating stage, corresponding to a fragmented condensate, and the reheating stage, corresponding to a particle cloud.

74 ATOMIC AND MOLECULAR PHYSICS↗

Software-Defined Virtual Synchronous Condenser

Synchronous condensers (SCs) play important roles in integrating wind energy into relatively weak power grids. However, the design of SCs usually depends on specific application requirements and may not be adaptive enough to the frequently-changing grid conditions caused by the transition from conventional to renewable power generation. This paper devises a software-defined virtual synchronous condenser (SDViSC) method to address the challenges. Our contributions are fourfold: 1) design of a virtual synchronous condenser (ViSC) to enable full converter wind turbines to provide built-in SC functionalities; 2) engineering SDViSCs to transfer hardware-based ViSC controllers into software services, where a Tustin transformation-based software-defined control algorithm guarantees accurate tracking of fast dynamics under limited communication bandwidth; 3) a software-defined networking-enhanced SDViSC communication scheme to allow enhanced communication reliability and reduced communication bandwidth occupation; and 4) Prototype of SDViSC on our real-time, cyber-in-the-loop digital twin of large-wind-farm in an RTDS environment. Furthermore, extensive test results validate the excellent performance of SDViSC to support reliable and resilient operations of wind farms under various physical and cyber conditions.

17 WIND ENERGY↗

Cloud Condensation Nuclei Particle Counter (CCN) Instrument Handbook

The Cloud Condensation Nuclei Counter—CCN (Figure 1) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility instrument for measuring the concentration of aerosol particles that can act as cloud condensation nuclei [1, 2]. The CCN draws the sample aerosol through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in this process, are counted (and sized) by an Optical Particle Counter (OPC). Thus, activated ambient aerosol particle number concentration as a function of supersaturation is measured. Models CCN-100 and CCN-200 differ only in the number of humidifier columns and related subsystems: CCN-100 has one column and CCN-200 has two columns along with dual flow systems and electronics.

54 ENVIRONMENTAL SCIENCES↗

Technologies for Enhanced Condensation in sCO 2 Power Cycles

The direct fired supercritical carbon dioxide power cycle has higher efficiency, compact machinery footprint, and is resilient under transient operation. It has been shown that improving the cycle main cooler significantly improves performance, including increased cycle efficiency, decreased cost of electricity and decreased cooler outlet temperatures. One way to improve this process is through enhanced condensation techniques and management of condensation fluid. This manuscript provides an overview of active and passive enhanced condensation technologies, with a focus on the passive approaches. compared to passive approaches, active approaches can have higher heat transfer enhancement, but the additional power and infrastructure can be problematic. The passive approaches identified include microfins (helical and herringbone), corrugated tubing, dimpled tubing and pin fins. After comparison it is found that the microfin geometry has the best performance characteristics followed by the additively manufactured pin fins. It is noted that current literature around additively manufactured enhancements is lacking, and investigation of conventional as well as novel geometries fabricated in this manner may be worth further investigation. Benchmark correlations for these geometries are identified and their limitations outlined. For further investigation, a matrix of test articles is presented for possible experimentation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗