Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

X-ray Micro-Computed Tomography for Structural Analysis of All-Solid-State Battery at Pouch Cell Level

Characterizing the microstructure of all-solid-state batteries (ASSBs) during fabrication and operation is vital for their advancement, particularly as scaling to pouch cell levels introduces challenges in probing large-scale microstructural evolution. This work highlights the potential of synchrotron X-ray micro-computed tomography (sXCT) as a nondestructive, rapid (<30 min), and high-resolution technique for visualizing and quantifying key microstructural features, including overhang, porosity, contact loss, active surface area, and tortuosity, in all-solid-state pouch cells. The large field of view (up to millimeters) of sXCT enables detailed analysis at an industry-relevant scale, bridging the gap between laboratory research and commercial applications. Furthermore, integrating realistic sXCT-derived 3D models into multiphysics simulations could provide insights into chemo-mechanical degradation, particularly at the edges of the pouch cells, offering a pathway for designing robust, high-performance ASSBs. This perspective establishes sXCT as an indispensable tool for advancing both the understanding and the engineering of next-generation energy storage systems.

25 ENERGY STORAGE↗

Regularizing INR with Diffusion Prior for Self-Supervised 3D Reconstruction OF Neutron Computed Tomography Data

Recently, generative diffusion priors have made huge strides as inverse problem solvers, including the ability to be adapted for inference on out-of-distribution data. Concurrently, implicit neural representations (INRs) have emerged as fast and lightweight inverse imaging solvers that are amenable to hybrid approaches that combine learned priors with traditional inverse problem formulations. In this paper, we present a diffusive computed tomography (CT) inversion framework for regularizing INRs called Diffusive INR (DINR), designed to enable high-quality reconstruction from sparse-view neutron CT. Pretrained purely on synthetic data, DINR is evaluated on simulated and experimentally obtained observations of concrete microstructures, where traditional reconstruction methods suffer substantial degradation when the number of views is reduced. Our approach delivers superior performance, reduces reconstruction artifacts, and achieves gains in PSNR and SSIM, enabling accurate micro-structural characterization even under extreme data limitations compared to state-of-the-art sparse-view reconstruction techniques.

Hossain, Maliha [ORNL]↗

Integration of Risk Survival Measures Estimated From Pre- and Posttreatment Computed Tomography Scans Improves Stratification of Patients With Early-Stage Non-small Cell Lung Cancer Treated With Stereotactic Body Radiation Therapy

To predict overall survival of patients receiving stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (ES-NSCLC), we developed a radiomic model that integrates risk of death estimates and changes based on pre- and posttreatment computed tomography (CT) scans. We hypothesize this innovation will improve our ability to stratify patients into various oncologic outcomes with greater accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ability of x‐ray computed tomography to resolve critical flaw size in laser‐based, paste stereolithography ceramic printing of alumina

Abstract Complex alumina parts were printed using vat photopolymerization (VPP), which is a stereolithography‐based additive manufacturing (AM) technique used to shape ceramic preforms, or green parts. The critical flaw size was determined using classical fracture mechanics techniques. The strength and fracture toughness were measured and compared to flaws detected in x‐ray computed tomography (XCT or CT) distributions as well as the fracture surfaces. The strength was lower compared traditionally made alumina, and that is due to layering effects, slurry defects, and printing defects. The critical flaw size from fracture mechanics was 206 µm. XCT has high enough resolution to detect the critical flaw size and much smaller features, where the average flaw size observed in CT scans was around 80–100 µm. The fracture surfaces indicate that flaws causing failure are larger than that of the critical flaw size (∼300 µm), but fracture surfaces do not show definitive features compared to traditionally made ceramics. Since XCT can observe flaws smaller than the critical flaw size, this method can be used as a screening technique.

36 MATERIALS SCIENCE↗

High-Resolution Computed Tomography Dataset of Mount Simon Sandstone

The Illinois Basin is a critical structure for subsurface energy related activities and their implementation in the United States. The Mount Simon Sandstone has been identified as a storage target for permanent and transient storage of fluids in the basin. Known for its exceptional thickness, depth, porosity, and sealing properties of overlying formations, this saline reservoir is crucial for long-term subsurface energy efforts. We present an extensive Computed Tomography (CT) dataset on a high porosity and permeability zone in the lower Mount Simon Sandstone available on the Energy Data eXchange® (EDX). This publicly accessible database comprises over 500 GB of high-resolution CT scans of six core samples, with resolutions ranging from 14.8 µm to 0.7 µm per pixel. The scans include both dry sandstone samples and those saturated with multiple fluids, allowing for comparative analyses across different conditions and resolutions. Coarser scans capture the bedding structure of the sandstone, while finer resolutions reveal detailed pore infill and throat characteristics. Metadata on location, depth, and saturation state enhance usability, enabling quick identification and cross-sample comparisons. By providing a robust resource for research and collaboration, the database contributes to domestic energy advancement by supporting continued progress in the use of the subsurface for energy solutions.

characterization↗

Qualitative and quantitative analysis of neutron irradiation effects in SiC/SiC composites using X-ray computed tomography

Silicon carbide fiber-reinforced silicon carbide matrix (SiC/SiC) composites are candidate materials for cladding of light water reactor (LWR) fuels. Loss of fission product gas retention due to the formation of microcrack networks is considered a potential failure mechanism for SiC/SiC-cladded fuels. In this work, a variety of SiC/SiC composite tubes were irradiated with and without an LWR-relevant radial heat flux in the High Flux Isotope Reactor, followed by detailed characterization with X-ray computed tomography (XCT). This first set of XCT data for neutron-irradiated samples confirmed that the internal stresses arising from a combination of temperature gradients and irradiation-induced swelling act as the primary driver for cracking. Consequently, while the observed cracking patterns varied depending on the tube architectures, the sharp edges of relatively large pores were found to be the common stress concentrator. These findings are useful to help improve the design and manufacturing of SiC/SiC fuel claddings for reduced failure probability.

42 ENGINEERING↗

Tools for pressure core sub-coring and pore-scale micro-CT (computed tomography) scans

Abstract. The pore habits of gas hydrate in natural sediment matrices provide essential clues for understanding physical (mechanical, thermal, hydraulic, and electrical) properties of hydrate-bearing sediments, yet there are no tools that can directly visualize the pore habits of natural gas hydrate other than indirect interpretation based on core-scale or field-scale observations. A significant challenge is to obtain a mini-core from pressure cores retrieved from natural reservoirs for high-resolution micro-CT (computed tomography) scans while maintaining pressure and temperature conditions required for stability of gas hydrate during all operational steps including manipulation, cutting, transferring, sub-coring and CT scanning. We present a new set of tools for pore-scale micro-CT imaging of natural hydrate-bearing sediments while maintaining pressure and temperature control. The tests with laboratory-prepared cores and pressure cores successfully demonstrate the capability of this set of tools to subsample a mini-core from pressure cores, transfer the mini-core to an X-ray transparent core holder, and conduct micro-CT scans. Successfully obtained CT images prove the functionality of this set of tools.

Seol, Yongkoo↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

Method for measurement of TRISO kernel and layer volumes by X-ray computed tomography

Layer dimensions are key parameters for as-fabricated tristructural-isotropic (TRISO) particle fuel as well as for post-irradiation examination of particle performance. Layer thicknesses are typically measured by optical microscopy of the particle cross section near mid-plane, while layer volumes are estimated with serial sectioning and microscopy. This method for measuring layer volumes is limited due to the resolution limit imposed by slice thickness and the effect of the polishing process on delicate irradiated particle microstructures. In this study, image processing software has been developed to segregate the three-dimensional (3D) TRISO particle images provided by x-ray computed tomography (XCT) into high-resolution volumetric data for the kernel, all particle layers, and any internal voids introduced during irradiation. These data can be used to analyze key in-reactor behaviors of TRISO particles such as kernel swelling or buffer shrinkage, which are important inputs for fuel performance modeling.

36 MATERIALS SCIENCE↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Microstructure of irradiated AGR TRISO particle buffer layers as measured by X-ray computed tomography

Shrinkage of the initially low-density buffer layer in tristructural isotropic (TRISO) coated fuel particles during irradiation is a well-known phenomenon with potential implications for fission product and actinide transport, as well as potential pyrocarbon fracture that in some cases has been observed to impact particle performance. During post-irradiation examination, the buffer layer's structure is commonly determined using 2D microscopy of a particle cross section or a series of particle cross sections at staggered depths. Although these methods provide a general idea of the irradiated buffer microstructure, they do not provide a full picture of the TRISO coating microstructure. By contrast, x-ray computed tomography (XCT) provides full 3D imaging of the TRISO particle. Particles from various compacts irradiated for the Advanced Gas Reactor Fuel Development and Qualification Program were imaged using XCT. Some of these particles were selected because of abnormal fission product inventories (e.g., low 137 Cs), whereas others were randomly selected from the center of the fission product inventory distribution. Qualitative and quantitative analysis techniques were applied to the randomly selected particles as representatives of typical TRISO behavior to study the post-irradiation structure of the buffer layer. These results showed that, while separation of the buffer and inner pyrolytic carbon layers was a common behavior during the radiation-induced shrinkage of the buffer, a portion of the original buffer/inner pyrolytic carbon interface remained intact throughout irradiation in nearly all cases. Furthermore, these results also indicated clear trends in the degree of buffer densification with irradiation temperature and fluence.

36 MATERIALS SCIENCE↗

Evolution of texture and internal stresses within polycrystalline rock salt using in situ 3D synchrotron computed tomography and 3D X-ray diffraction

Over time rock salt caverns have been extensively used as reliable repositories for hazardous waste such as nuclear waste, oil or compressed gases. Undisturbed rock salt deposits in nature are usually impermeable and have very low porosity. However, rock salt formations under excavation stresses can develop crack networks, which increase their porosities; and in the case of a connected crack network within the media, rock salt may become permeable. Although the relationship between the permeability of rock salt and the applied stresses has been reported in the literature, a microscopic study that investigates the properties influencing this relationship, such as the evolution of texture and internal stresses, has yet to be conducted. This study employs in situ 3D synchrotron micro-computed tomography and 3D X-ray diffraction (3DXRD) on two small-scale polycrystalline rock salt specimens to investigate the evolution of the texture and internal stresses within the specimens. The 3DXRD technique measures the 3D crystal structure and lattice strains within rock salt grains. The specimens were prepared under 1D compression conditions and have shown an initial {111} preferred texture, a dominant {110}$\langle1\bar{1}0\rangle$ slip system and no fully connected crack network. The {111} preferred texture under the unconfined compression experiment became stronger, while the {111}$\langle1\bar{1}0\rangle$ slip system became more prominent. The specimens did not have a fully connected crack network until applied axial stresses reached about 30 MPa, at a point where the impermeability of the material becomes compromised due to the development of multiple major cracks.

36 MATERIALS SCIENCE↗

Imaging APO-BMI with Micro X-ray Computed Tomography (CT)

APO-BMI is a high-strength, high-temperature, and low-density foam comprised of 1,2-bis(2-aminophenylthio) ethane (APO-Link, formerly Apocure-601) and 4,4’-bismaleimidodiphenylmethane (BMI) that is used structural applications within the aerospace and weapons manufacturing sectors. APO-link is the diamine reagent used to synthesize BMI, a thermosetting resin. This resin can remain in a molten, flowing state for an extended period of time before crosslinking, allowing addition of glass or carbon microballoons to form its final structure. A portion of the current project was to observe the thermal effects on the structural integrity of the foam associated with exposure to an ion beam. Features within the foam were imaged using micro X-ray computed tomography (CT). The resulting imaging provided evidence that microballoon structure remained mostly intact at the points of failure, indicating that the failure of the material was occurring in the binder material.

36 MATERIALS SCIENCE↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Anisotropic thermal diffusivity and conductivity in SiC/SiC tubes studied by infrared imaging and X-ray computed tomography

Traditional flash diffusivity evaluation of thermal diffusivity/conductivity of composite tubes require machining of specimens. For a thin-wall tube, this method can only be used to obtain through-thickness transport property. A novel method to evaluate anisotropic thermal diffusivity in a composite tube has been developed. Braided SiC/SiC composite tubes were subjected to a xenon flash heating pulse. A high-speed, high-sensitivity infrared camera was used to measure surface temperature changes as a function of time and nondestructively detect subsurface defects/damages, such as macroscopic pores. Standard reference material (Pyroceram 9606) and curved SiC/SiC composite tube specimens were used to validate thermal diffusivity obtained from infrared imaging. Unlike the traditional method, there is no need prepare special specimens, and thermal diffusivity values in three orientations are obtained after a single flash. A finite element analysis model based on x-ray computed tomography scans was developed to simulate the heat transfer. In conclusion, this technique is significant in assessing thermal conductivity and inspecting the health of ceramic tubes during and after service.

36 MATERIALS SCIENCE↗

Hydro-mechanical behavior of heated bentonite buffer for geologic disposal of high-level radioactive waste: A bench-scale X-ray computed tomography investigation

The behavior of heated bentonite buffer is critical for the security and long-term performance of a geological repository for high-level radioactive waste (HLW). While laboratory column experiments have been conducted to investigate compacted bentonite and coupled THMC (thermal-hydro-mechanical and chemical) processes for a moderate temperature range of up to 100 °C, data for a higher temperature range are limited. Understanding bentonite behavior and coupled THMC processes under higher temperatures (e.g., up to 200 °C) could allow for a more economic repository design and would expand the data and knowledge base for more reliable modeling. In this study, a bench-scale experiment was conducted in a compacted bentonite column experiencing both heating up to 200 °C in the center and hydration from a sand-clay boundary surrounding the column. During the experiment run for 1.5 years, frequent X-ray computed tomography (CT) scanning of bentonite provided insights into the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. After the experiment, a comprehensive post-dismantling characterization of bentonite samples was conducted. Results showed that the bentonite hydration was axi-symmetrical despite the initial heterogeneity due to packing, confirming the ability of bentonite to seal fast flow/transport paths. Further, compared to a non-heated control experiment, the heated column showed greater CT density variations along the radial distance, indicating that homogenization of bentonite might be more difficult if a temperature gradient is maintained in the repository. Precipitation of an anhydrite layer occurred in the inner hot zone, pointing to potential concerns about salt precipitation causing canister corrosion. Ultimately, the experiments provided a high-resolution window into the strongly dynamic and coupled behavior of bentonite exposed to heating, hydration and swelling, which will be valuable for improving modeling of coupled processes, especially for the early state of a HLW repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗