A Modern Ethernet Data Acquisition Architecture for Fermilab Beam Instrumentation

The Fermilab Accelerator Division, Instrumentation Department is adopting an open-source framework to replace our embedded VME-based data acquisition systems. Utilizing an iterative methodology, we first moved to embedded Linux, removing the need for VxWorks. Next, we adopted Ethernet on each data acquisition module eliminating the need for the VME backplane in addition to communicating with a rack mount server. Development of DDCP (Distributed Data Communications Protocol), allowed for an abstraction between the firmware and software layers. Each data acquisition module was adapted to read out using 1 GbE and aggregated at a switch which up linked to a 10 GbE network. Current development includes scaling the system to aggregate more modules, to increase bandwidth to support multiple systems and to adopt MicroTCA as a crate technology. The architecture was utilized on various beamlines around the Fermilab complex including PIP2IT, FAST/IOTA and the Muon Delivery Ring. In summary, we were able to develop a data acquisition framework which incrementally replaces VxWorks & VME hardware as well as increases our total bandwidth to 10 Gbit/s using off the shelf Ethernet technology.

43 PARTICLE ACCELERATORS↗

Methods for microwave characterization of electro-optic crystals for quantum transduction

Microwave-optic quantum transducers are essential devices to develop distributed quantum networks and implement related quantum communication protocols. Three dimensional high-coherence time microwave cavities embedded with electro-optic nonlinear dielectric materials provide promising platforms to boost the efficiency of the microwave-optic frequency conversion. However, so far, the properties for such dielectric crystals operating at milli-Kelvin cryogenic temperatures have not been well understood. Here, we propose a scheme to precisely measure and benchmark the dielectric constant and analyze the dissipation mechanisms of electro-optic materials, such as Lithium Niobate, at the quantum threshold. We will use Fermilab’s three dimensional superconducting cavities with long coherence time. The proposed method of microwave characterization lays the foundations for engineering quantum transduction devices and quantum sensors with high conversion efficiency and fidelity.

Zorzetti, Silvia↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Methods for communicating data utilizing sessionless dynamic encryption

The present disclosure is directed to methods that provide a secure communication protocol by utilizing one step process of authenticating and encrypting data without having to exchange symmetric keys or needing to renew or re-issue digital identities fundamental to asymmetric encryption methodology.

Choi, Sung Nam↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control: Preprint

This paper validates the effectiveness of an Artificial Intelligence (AI)-driven PV plant control and optimization approach, namely, the Automated Learner for Intermittency Control by Extrapolation (ALICE), in empowering PV plant as a dependable grid reliability service provider. The validation is performed in a realistic laboratory controller-hardware-in-the-loop (CHIL) environment, leveraging accurate PV plant modeling and standard industrial communication protocol. Simulation results, considering both varying weather conditions and active control scenarios, demonstrate the superior performance of ALICE in improving the grid service delivery precision and reducing the over-curtailment compared to a state-of-the-art approach, i.e., reference-control grouping based approach. Such a work could help mitigate risks and provide practical guidance during the field deployment of ALICE, while establishing a standardized testing framework for evaluating various PV active control strategies.

hardware-in-the-loop↗

Development of a Reference Design for a Cyber-Physical System

The purpose of this thesis is to develop a reference design to assist in the selection of security practices in power electronics design. A prototype will be developed from this reference design for evaluation. This evaluation will include a brief cost/benefit analysis to gauge the efficacy of implementing each layer of security throughout the power electronics design process. This thesis will also describe the obstacles and effectiveness of integrating a Trusted Platform Module (TPM) into a cyber-hardened grid-connected device. The TPM device is a secured crypto processor that assists in generating, storing, and restricting the use of cryptographic keys. The emphasis of this research is to establish integrity, authenticity, and confidentiality within a system by providing a baseline of security concerns for segments of the system. This research considers communication, control, and hardware level securities. The scope of this thesis will review the necessary security methods as well as consider the effects these methods have on the embedded system, to assess the desired security to responsiveness trade off. Applying this approach to a design process will alleviate various unknowns of appending security to a power electronics design. This thesis describes the specific vulnerabilities introduced within this grid-edge environment, and how the liabilities within the system can be mitigated. Initially, common security techniques will be considered to establish a guideline to benchmark performance and resource costs of the system. The foundation will be a non-hardened power electronic system platform with industry standard communication protocols. Several security techniques and attack vectors will then be evaluated to contribute to the base level platform. Other fail-safe features take place to gauge progress of the selected approach, non-inclusive to the TPM. Collectively, this investigation will determine a valid experiment by appraising and categorizing resource allocation, performance overhead, and monetary cost analysis results into a reference design. The prototype will then demonstrate methods to relieve common threats that are purposefully implemented into the design.

Blair, Nicholas Paul↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Value-based Insights from the Implementation of Hierarchical Control for Energy Savings and Demand Response in Residential Premises

As the adoption of distributed energy resources and electric vehicles at residential customer premises increases exponentially, behind-the-meter assets can be utilized to achieve energy cost reduction and demand response through coordination and control strategies. A hierarchical control architecture from the utility headend to residential premises is implemented to attain these objectives. This paper extracts the values from the development, implementation, and deployment of that control hierarchy. The development of the control philosophy is built upon the existing advanced metering infrastructure, communication protocols, and industry-compatible application programming interfaces. Results are presented visually with analytical insights by utilizing the data from hardware-in-the-loop testing and simulation analysis out of the collected data from the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

A Typing Discipline for High-Assurance Control Systems

This poster describes a typing discipline for high-assurance industrial systems based on three novel type systems. The first type system, information flow control (IFC), controls the flow of data through the system. The second system, dependent session types, restricts messages exchanged during the execution of a communication protocol to avoid dangerous states. The third system uses dimensional analysis to avoid subtle bugs that adversaries can exploit to cause the system to enter a dangerous state. This poster describes how a combination of these approaches can prevent sophisticated cyber attacks, such as the infamous Stuxnet incident, from occurring. In addition, we provide experimental evidence to support the claim that these approaches can be applied in control systems that are resource-constrained.

42 - ENGINEERING↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

IEEE 1547-2018 Based Interoperable PV Inverter with Advanced Grid-Support Functions

Grid integration of photovoltaic (PV) inverters has been increasing in the past decade. As a result of the uncertainties introduced with high penetrations of PV, better monitoring and control of the PV inverters becomes crucial for improving overall system stability. This paper focuses on the communications capability of the inverter controller and on enabling interoperability. Multiple standards are available to enable interoperability in PV inverters. In this paper, an interoperable controller, enabled by Distributed Network Protocol 3 (DNP3) communications protocols, is developed for a grid-connected, three-phase PV inverter. The DNP3 server for the PV inverter is programmed on the real-time layer of the field-programmable gate array (FPGA)-based inverter controller. Set points for advanced inverter control functions, such as volt/VAr curves, ride-through curves, are sent from a DNP3 client, a simulated distribution management system application, to the PV inverter through DNP3. This communications capability of the inverter controller is validated using a controller-hardware-in-the-loop experimental setup. The code developed to achieve the interoperability is available in the public domain through open-source software licensing. This interoperability will enable smoother grid integration of smart PV inverters with advanced grid-support functions as well as allow better monitoring and control of PV inverters for grid stability.

14 SOLAR ENERGY↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Firmware Tampering Detection in Heavy-Duty Vehicles through J1939 CAN Analysis

Modern heavy-duty vehicles rely on complex networks of Electronic Control Units (ECUs) that communicate using the J1939 protocol. While this system makes it easier to update and configure vehicle components, it also opens the door to serious cybersecurity risks if not properly secured. This work investigates the potential for firmware tampering through the J1939 communication protocol, which enables ECU configuration and reprogramming over the Controller Area Network (CAN) bus. By monitoring CAN traffic during legitimate maintenance operations and reverse-engineering OEM diagnostic software, we identified common and proprietary J1939 message identifiers, authentication patterns, and vulnerabilities within Unified Diagnostic Services (UDS). These findings demonstrate that inadequate authentication mechanisms can allow malicious actors to alter ECU firmware or disable safety functions, posing severe operational and safety risks. Our analysis contributes to the development of vehicle intrusion detection systems capable of recognizing abnormal reprogramming activity and future firmware fingerprinting methods to verify software integrity across ECUs. This work highlights the importance of standardizing secure firmware authentication across manufacturers to strengthen cyber resilience in heavy-duty vehicle systems.

33 ADVANCED PROPULSION SYSTEMS↗

Integrity Enhancing Protocols: Performance and Recommendations for Nuclear Systems

In today’s communication landscape there are multiple technologies and protocols used for communication between end devices. Within security paradigms for these protocols, integrity management is a common goal of system designers. Communication protocols focused on maintaining message integrity can provide assurance that some received data has not been altered or tampered with. While integrity is often coupled with confidentiality in protocol design, this analysis focuses on an evaluation of only integrity protocols. This report outlines various ways message integrity may be preserved with respect to high performance operational technology (OT) systems. It describes a series of experiments and an evaluation framework used to evaluate the performance of the identified integrity approaches regarding common system design goals. Finally, it addresses the testing environment utilized and closes the report with a summary of experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗