Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cold climate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impacts of Thawing Permafrost on Residential Infrastructure: Results and Resources

Permafrost underlies approximately 20% of the landmass in the Northern Hemisphere. Inevitably human infrastructure has been and will be built on permafrost; however, due to climate change, the permafrost in many regions has begun to thaw. Using past reports and surveys as guidance, a survey was conducted to track the effects of permafrost thaw on housing infrastructure in the community of Point Lay, Alaska. The Cold Climate Housing Research Center, Inc. and the National Renewable Energy Lab conducted a literature review and interviews to document community issues from thawing permafrost and identify potential mitigation strategies for existing and new infrastructure. Researchers also identified strategies for individual homeowners to inspect their foundations for current issues or anticipate future ones. This poster will cover the results from the survey on the effects of permafrost thawing to Point Lay and include permafrost basics, common concerns from thawing permafrost, steps to identify permafrost sites and visible signs of permafrost degradation, and potential mitigation strategies that may be beneficial to Alaskans and increase resilience in the Arctic.

Alaska↗

Near-cryogenic direct air capture using adsorbents

Direct air capture (DAC) of CO 2 is a key component in the portfolio of negative emissions technologies for mitigating global warming. However, even with the most potent amine sorbents, large-scale DAC deployment remains limited by high energy and capital costs. Recently, adsorbents relying on weak interactions with CO 2 have emerged as a potential alternative, thanks to their rapid adsorption kinetics and superior long-term stability, particularly under sub-ambient conditions (∼253 K). Despite these advantages, their use is hindered by the need for a water-removal process, location-specific constraints, and insufficient working capacity even in cold climates. In this study, we hypothesized that further reducing the adsorption temperature to a near-cryogenic range (160–220 K) could enable cost-effective DAC by utilizing the full potential of physisorbents. We primarily consider integrating DAC with a relatively untapped source of cold energy—liquified natural gas (LNG) regasification—to perform near-cryogenic DAC. From large-scale molecular simulations, Zeolite 13X and CALF-20 were identified as promising candidates. These materials were subsequently examined through experiments, including breakthrough analyses at 195 K. Their high CO 2 sorption capacity (4.5–5.5 mmol g −1 ), combined with a low desorption enthalpy and robust long-term stability, led to a threefold reduction in the levelized cost of capture (down to 68.2 USD per tonne CO 2 ). Estimates of the global LNG regasification resource suggest that LNG–DAC coupling could potentially enable the capture of 103–142 megatonnes of CO 2 annually as of 2050.

Kim, Seo-Yul [Georgia Institute of Technology, Atl↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Enhanced Habitability on High Obliquity Bodies near the Outer Edge of the Habitable Zone of Sun-Like Stars

High obliquity planets represent potentially extreme limits of terrestrial climate, as they exhibit large seasonality, a reversed annual-mean pole-to-equator gradient of stellar heating, and novel cryospheres. A suite of 3D global climate model simulations is performed for low and high obliquity planets with various stellar fluxes, CO2 concentrations, and initial conditions to explore the propensity for high obliquity climates to undergo global glaciation. We also simulate planets with thick CO2 or H2 atmospheres, such as those expected to develop near or beyond the outer edge of the habitable zone. We show that high obliquity planets are hotter than their low obliquity counterparts due to ice-albedo feedbacks for cold climates, and water vapor in warm climates. We suggest that the water vapor greenhouse trapping is greater on high obliquity bodies for a given global-mean temperature due to the different dynamical regimes that occur between the two states. While equatorial ice belts are stable at high obliquity in some climate regimes, it is substantially harder to achieve global glaciation than for a low obliquity planet. Temperate polar conditions can be present at high obliquity at forcings for which low obliquity planets would be in a hard snowball state. Furthermore, open ocean can persist even in the winter hemisphere and when global-mean temperatures are well below freezing. However, the influence of obliquity diminishes for dense atmospheres, in agreement with calculations from 1D energy balance models.

Planet and satellite atmospheres↗

Enhanced Habitability on High Obliquity Bodies Near the Outer Edge of the Habitable Zone of Sun-Like Stars

High obliquity planets represent potentially extreme limits of terrestrial climate, as they exhibit large seasonality, a reversed annual-mean pole-to-equator gradient of stellar heating, and novel cryospheres. A suite of 3-D global climate model simulations with a dynamic ocean is performed with Earthlike atmospheres for low and high obliquity planets with various stellar fluxes, CO2 concentrations, and initial conditions to explore the propensity for high obliquity climates approaching the outer edge of the Habitable Zone to undergo global glaciation. We also simulate planets with thick CO2 or H2 atmospheres, such as those expected to develop near or beyond the outer edge of the Habitable Zone. We show that high obliquity planets are hotter than their low obliquity counterparts due to ice-albedo feedbacks for cold climates, and water vapor in warm climates. We suggest that the water vapor greenhouse trapping is greater on high obliquity bodies due to the different dynamical regimes that occur between the two states. While equatorial ice-belts are stable at high obliquity in some climate regimes, it is harder to achieve global glaciation than for a low obliquity planet. Temperate polar conditions can be present at high obliquity at forcings for which low obliquity planets would be in a hard snowball state. We suggest the conditions on high obliquity planets are likely to be more favorable for a robust biosphere to develop approaching the outer edge of the HZ. However, the influence of obliquity diminishes for dense atmospheres, in agreement with calculations from 1-D Energy Balance Models.

planets and satellites: atmospheres↗

Metabolic skinflint or spendthrift? Insights into ground sloth integument and thermophysiology revealed by biophysical modeling and clumped isotope paleothermometry

Abstract Remains of megatheres have been known since the 18th -century and were among the first megafaunal vertebrates to be studied. While several examples of preserved integument show a thick coverage of fur for smaller ground sloths living in cold climates such as Mylodon and Nothrotheriops , comparatively very little is known about megathere skin. Assuming a typical placental mammal metabolism, it was previously hypothesized that megatheres would have had little-to-no fur as they achieved giant body sizes. Here the “hairless model of integument” is tested using geochemical analyses to estimate body temperature to generate novel models of ground sloth metabolism, fur coverage, and paleoclimate with Niche Mapper software. The simulations assuming metabolic activity akin to those of modern xenarthrans suggest that sparse fur coverage would have resulted in cold stress across most latitudinal ranges inhabited by extinct ground sloths. Specifically, Eremotherium predominantly required dense 10 mm fur with implications for seasonal changes of coat depth in northernmost latitudes and sparse fur in the tropics; Megatherium required dense 30 mm fur year-round in its exclusive range of cooler, drier climates; Mylodon and Nothrotheriops required dense 10–50 mm fur to avoid thermal stress, matching the integument remains of both genera, and further implying the use of behavioral thermoregulation. Moreover, clumped isotope paleothermometry data from the preserved teeth of four genera of ground sloth yielded reconstructed body temperatures lower than those previously reported for large terrestrial mammals (29 ± 2°–32 ± 3° C). This combination of low metabolisms and thick fur allowed ground sloths to inhabit various environments.

Deak, Michael D.↗

Impact of electric vehicle charging on the power demand of retail buildings

As electric vehicle penetration increases, charging is expected to have a significant impact on the grid. Electric vehicle charging stations will greatly affect a building site's power demand, especially with the onset of fast charging with power levels as high as 350 kW per charger. Here, we assess how electric vehicle charging stations would impact a retail big box grocery store, exploring numerous station sizes, charging power levels, and utilization factors in various climate zones and seasons. We measure the effect of charging by assessing changes in monthly peak power demand, electricity usage, and annual electricity bill, computed using three distinct rate structures. We find that an electric vehicle station has the potential to dwarf a big box building's power demand if behind the same meter, increasing monthly peak power demand at the site by over 250%. Cold-climate areas paired with rate structures incorporating high demand charges are most susceptible for significant changes to the annual electricity bill, with increases as high as 88%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LCC-based framework for building envelope and structure co-design considering energy efficiency and natural hazard performance

Herein, this paper presents a life-cycle cost (LCC) informed co-design framework for building structures and envelope systems, holistically considering the influences of energy and natural hazard performance. The proposed method is consisted of a two-stage design and decision-making process, aiming to provide a quantitative guideline for building's structural and envelope co-design based on the its geographic locations. First, the building's structural configuration and envelope type are selected based on the life cycle cost. Then, the long-term cost effectiveness of various energy-saving building envelope options (e.g., high-performance glazing and insulation) is evaluated to refine the envelope design. The proposed co-design framework was demonstrated through the case study of a medium-size office building archetype in three locations with distinct climate conditions and seismic activities (i.e., Los Angeles, Memphis, and Boston). The results highlighted the interplay between building's structural (seismic) performance and the cost-effectiveness of energy-saving design options – e.g., for buildings located in high-seismic regions, seismic enhancing designs greatly reduce the paybak period of high performance building envelope by reducing the seismic loss; whereas for buildings located in regions with cold climate and low seismic risk such as Boston, spatial frame with high insulation building envelope shows the lowest LCC.

42 ENGINEERING↗

Wintertime East Asian Jet Stream and Its Association with the Asian-Pacific Climate

Interannual variability of the wintertime East Asian westerly jet stream and the linkage between this variability and the Asian-Pacific climate are investigated. The study emphasizes on the variability of the jet core and its association with the Asian winter monsoon, tropical convection, upper tropospheric wave patterns, and the teleconnection of the jet with other climate systems. The relationship between the jet and North Pacific sea surface temperature pattern (SST) is also explored. NCEP/NCAR reanalysis, NASA GISS surface temperature, NASA GEOS reanalysis, NOAA reconstructed SST, GPCP precipitation, and NOAA snow cover data sets are analyzed in this study. An index of the East Asian jet has been defined by the December-February means of the 200 mb zonal winds that are averaged within a box enclosing the jet maximum, which shifts only moderately from one year to another especially in the south-north direction. The jet links to a teleconnection pattern whose major climate anomalies appear over the Asian continent and western Pacific (west of the dateline). This pattern differs distinctly from the teleconnection pattern associated with El Nino/Southern Oscillation (ENSO), which causes the Pacific/North American pattern to the east of the dateline. A strong jet is accompanied clearly by an increase in the intensity of the atmospheric circulation over Asia and the Pacific. In particular, the winter monsoon strengthens over East Asia, leading to cold climate in the region, and convection intensifies over the tropical Asia-Australia sector. Changes in the jet are associated with broad-scale modification in the upper tropospheric wave patterns that leads to downstream climate anomalies over the eastern Pacific. Through this downstream influence, the East Asian jet causes climate signals in North America as well. A strong jet gives rise to warming and less snow cover in the western United States but reverse climate anomalies in the eastern part of the country, although these signals are relatively weaker than the jet-related anomalies in East Asia. There is a strong association between the East Asian jet and the North Pacific SST (NPSST). A strong jet is accompanied by a cooling in the extratropical Pacific and a warming in the tropical-subtropical Pacific. Evidence also indicates that the extratropical NPSST pattern plays a role in modulating the intensity of the jet stream. ENSO, the jet, and the NPSST are mutually interactive on certain time scales and such an interaction links closely to the climate anomalies in the Asian-Pacific-American regions.

Yang, Song↗

A bioinspired approach for adaptive solid-solid phase change material coatings with optimized surface features for passive thermal regulation

The necessity to reduce global energy consumption calls for innovative strategies in building thermal management. Passive thermal regulation, particularly through bio-inspired designs, offers a promising avenue by mimicking nature's efficient control of optical properties. This research introduces a novel, climate-responsive coating that integrates optimized bio-inspired surface features with a solid-solid phase change material (SS-PCM) to dynamically manage solar absorptivity without adding additional thickness, enabling both heating and cooling as needed. Drawing on the photonic architectures of the Saharan silver ant and Morpho Didius butterfly, we employed a modeling and multi-objective optimization framework to tailor these surface features. Simulations reveal that surface texture, rather than the intrinsic phase transition of the SS PCM, dominates optical control. Relative to a flat SS PCM coating, optimized isotropic random roughness and broader range features yielded the highest passive heating power increase of about 144 % and 319 % respectively suitable for cold climates. Saharan ant-inspired features enhanced passive cooling for hot climates, achieving a 21.8 % improvement. For moderate climates, Butterfly-wing-inspired surface features provided a balanced enhancement of 19 % for heating and 7 % for cooling. Across all cases, the optimized surface features reduced combined heating and cooling energy demand more effectively than the baseline coating, while preserving material thickness. These findings demonstrate that climate-adaptive, optimized bio-inspired surface features can unlock the full potential of SS PCM coatings, providing a versatile pathway to significant energy savings in buildings and other applications. The methodology establishes a framework for designing next-generation adaptive envelopes that leverage natural photonic principles for high-impact, low-cost thermal regulation.

36 MATERIALS SCIENCE↗

Energy impact of heating electrification in mid-rise multifamily buildings in mixed-humid climates

Decarbonizing the electric grid in conjunction with electrifying residential heating is a critical step to combat climate change. Heating in multifamily buildings with the existing natural gas-fired central boiler is a complex process that not only leads to overheating in some apartment units but also results in energy waste and high gas bills. In this study, we consider a multifamily building in New York City, USA, to evaluate the performance of five different heating systems, which represent a step-by-step transition from the conventional to a fully electrified heating system, and determine their impact on the site energy consumption and source CO 2 emissions. Results indicate that overheating in a multifamily building can raise the indoor temperature by as much as 8°C above comfortable limits. Transitioning from conventional steam radiators to cold climate heat pumps can reduce annual site heating energy by up to 70% and source CO 2 emissions by up to 21%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Dioxide Cycling And The Climate of Ancient Earth

The continental cycle of silicate weathering and metamorphism dynamically buffers atmospheric CO2 and climate. Feedback is provided by the strong temperature dependence of silicate weathering. Here we argue that hydrothermal alteration of oceanic basalts also dynamically buffers CO2. The oceanic cycle links with the mantle via subduction and the midocean ridges. Feedback is provided by the dependence of carbonatization on dissolved carbonates in seawater. Unlike the continental cycle, the oceanic cycle has no thermostat. Currently the continental cycle is more important, but earlier in Earth's history, especially if heat flow were higher than it is now, more vigorous plate tectonics would have made the oceanic cycle dominant. We find that CO2 greenhouses thick enough to defeat the faint early sun are implausible and that, if no other greenhouse gases are invoked, very cold climates are expected for much of the Proterozoic and the Archean. We echo current fashion and favor biogenic methane as the chief supplement to CO2. Fast weathering and probable subduction of abundant impact ejecta would have reduced CO2 levels still further in the Hadean. Despite its name, the Hadean would have been the coldest era in the history of the Earth.

Zahnle, Kevin↗

Carbon Dioxide Cycling and the Climate of Ancient Earth

The continental cycle of silicate weathering and metamorphism dynamically buffers atmospheric CO2 and climate. Feedback is provided by the strong temperature dependence of silicate weathering. Here we argue that hydrothermal alteration of oceanic basalts also dynamically buffers CO2. The oceanic cycle links with the mantle via subduction and the midocean ridges. Feedback is provided by the dependence of carbonatization on dissolved carbonates in seawater. Unlike the continental cycle, the oceanic cycle has no thermostat. Currently the continental cycle is more important, but earlier in Earth's history, especially if heat flow were higher than it is now, more vigorous plate tectonics would have made the oceanic cycle dominant. We find that CO2 greenhouses thick enough to defeat the faint early Sun are implausible and that, if no other greenhouse gases are invoked, very cold climates are expected for much of the Proterozoic and the Archean. We echo current fashion and favor biogenic methane as the chief supplement to CO2. Fast weathering and probable subduction of abundant impact ejecta would have reduced CO2 levels still further in the Hadean. Despite its name, the Hadean would have been the coldest era in the history of the Earth.

Zahnle, Kevin↗

Long-term impact of electrification and retrofits of the U.S residential building in diverse locations

The U.S. buildings sector contributes 30% of operational carbon emissions, with residential buildings accounting for 56%. Reducing residential carbon emissions is crucial for achieving net-zero carbon goal. While many studies examine energy efficiency retrofit (EER) and electrification, few explore their long-term impacts across diverse climates and dynamic grid clean energy penetrations, as well as their economic effects on households. Here, this study proposes a method to assess how EER and electrification affect long-term decarbonization and economics across different climates, focusing on carbon emissions, energy burden (the percentage of household income spent on energy), and payback period in four locations: Tampa, San Diego, Denver, and Great Falls. The study also introduces the concept of implicit energy burden by considering investment costs. Results show that while electrification can reduce long-term emissions with increased clean energy penetration, it may not always achieve decarbonization due to mismatches between clean energy availability and demand. In cooling-dominant locations, electrification lowers energy burden and peak demand, but in heating-dominant locations, it increases energy burden to 8.24%, raises peak demand by 632.78%, and shifts it from summer to winter. After integrating investment costs, the implicit energy burden can reach 8.35% in cold climates. For already highly electrified buildings in Denver and Great Falls, the payback period of EER measures can be shortened by up to 48.98%. The study highlights a tradeoff between decarbonization and energy burden alleviation, showing that while EER measures can reduce the energy burden, they only achieve one-quarter of the carbon emission reduction of electrification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Data from Heat Pumps Installed in Juneau, AK

Heat pumps offer a great low carbon emission method to heat homes. Thermalize Juneau 2021 was a clean energy campaign that helped homeowners in Juneau, Alaska install heat pumps into their homes. Juneau is located near the climactic limit of many heat pumps, and we were interested in how well the heat pumps can function in cold climates. This was done by using Sense meters to remotely monitor the energy usage of 10 homes with heat pumps. The Sense meters are small devices that connect to the electrical panel and monitor the energy use of multiple appliances through machine learning. First, we recorded the energy usage of a heat pump in the lab using both the Sense meter and the existing lab datalogger. Both recorded very similar energy usage data which confirmed that the Sense meter can accurately measure the fluctuations in the heat pump energy use. Next, we looked at the energy data from the Sense meters in the homes with heat pumps and paired it with local weather data to see how well the heat pumps functioned in the cold weather.

Alaska↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Achieving 50% Energy Savings in Chicago Homes: A Case Study for Advancing Equity and Climate Goals

Since 2019, the National Renewable Energy Laboratory (NREL) and Elevate have collaborated to identify pathways to deep energy retrofits in Chicago's housing stock, document equity implications and co-benefits of this transition, and validate the findings by implementing retrofits in real Chicago homes. This document summarizes our analysis process to model advanced retrofit packages that lead to greater than 50% energy savings in Chicago homes. Based on these findings, we have also developed a roadmap with the City to guide implementation, and are deploying the recommended retrofit packages in real Chicago homes to realize these energy savings. This work was developed in collaboration with two key stakeholders - the City of Chicago and Commonwealth Edison (ComEd) - and funded by the U.S. Department of Energy (DOE). NREL's Residential Buildings team maintains the best-in-class ResStock™ energy model of the U.S. residential building stock. For this work, we calibrated ResStock to Chicago's unique local housing stock to accurately simulate energy use in Chicago homes both for current conditions and with various retrofit scenarios. We simulated a wide range of potential building retrofits covering all aspects of residential energy use and then grouped these into packages based on energy and utility bill savings. ResStock can model diverse building types and housing characteristics, so we're able to observe the range of outcomes that might occur when these upgrades are deployed across the entire housing stock. We can then estimate potential energy savings from an advanced retrofit program on Chicago's housing stock by comparing the modeled energy use before versus after a retrofit. This novel version of ResStock, calibrated to Chicago with data from Elevate, can help City officials, ComEd, and other partners plan for community-scale decarbonization via residential retrofits. Specifically, this work contributes the following project goals: Develop a building retrofit prioritization strategy for Chicago single-family and 2- to 4-unit buildings; Identify neighborhoods and home types that have the highest potential for savings from electrification; and Assess the impact of advanced building retrofits on energy use, utility bills, and CO2 emissions at the city and building level. Although this study is specific to Chicago, its methods and learnings are applicable across the United States. These findings are especially notable for heat pumps and electrification retrofits in cold climates.

building energy modeling↗

Facilitating Large‐Scale Snow Shedding from In‐Field Solar Arrays using Icephobic Surfaces with Low‐Interfacial Toughness

Abstract Large‐scale accrual of snow and ice on solar arrays in northern latitudes can cause significant power generation losses during winter. Depending on environmental conditions, snow can encompass a wide range in physical characteristics from dry snow (modulus ≈100 kPa and density ≈0.1 g cm −3 ) to bulk ice (modulus ≈8 GPa and density ≈0.9 g cm −3 ). This variation in snow morphology has made the development of a passive, broad‐spectrum, snow and ice‐shedding surface challenging. Here, the authors develop one of the first surfaces that simultaneously possesses both low‐interfacial strength ( τ˄ ice < 50 kPa) and toughness (Γ ice < 0.5 J m −2 ) with ice. These surfaces, fabricated via the addition of mobile polymer chains/oils to a thin polymeric coating, require extremely low detachment forces for ice, enabling its passive shedding at virtually any accretion length scale. Preliminary evidence that the new surfaces can shed different forms of snow and ice from field‐deployed solar arrays, over a range of subzero temperatures for several weeks, leading to significant increases in power generation is provided. The optically transparent surfaces are easily scalable and can be widely deployed by the solar industry in areas that see persistent snow. Other applications include automotive windshields, LIDAR covers for autonomous vehicles, and cold climate optical sensors.

Dhyani, Abhishek↗