Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “city evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tensile Performance Sensitivity to Variations of Standard 17-4 PH Heat Treatments on LPBF-Produced Material

Standard heat treatments for metals of a particular composition are typically designed with the assumption of a conventional starting microstructure, such as that produced by casting or wrought processing. When applied to metals fabricated by Laser Powder Bed Fusion (LPBF) metal additive manufacturing (AM), these heat treatments can produce inconsistent performance due to the unique as-built microstructures. This study investigates how modifications to standard heat treatments for 17-4 PH steel influence the microstructure and mechanical properties of LPBF-fabricated material. Specimens were produced and subjected to varying solutionizing and homogenizing treatments followed by standard aging treatments. Microstructures were characterized using optical microscopy, Electron Backscatter Diffraction (EBSD), and X-ray diffraction (XRD), and mechanical properties were evaluated through uniaxial tensile testing. Based on these results, recommendations are provided for achieving improved wrought-like performance in LPBF 17-4 PH steel.

17-4 PH↗

Increasing Electric Vehicle Adoption Among Disadvantaged Populations: A Case Study in Los Angeles

In striving for 100% carbon-free energy by 2035, ensuring equitable access and benefits across all populations is crucial. The shift toward clean energy and sustainable transport involves numerous challenges, requiring collective efforts from various stakeholders to develop inclusive strategies and policies. This includes community engagement, equitable funding for technology, and expansion of programs to foster an equitable energy transition. Additionally, while cities have initiated incentive programs to promote electric vehicle (EV) adoption, the effectiveness of these programs in ensuring affordable EV ownership for disadvantaged communities is yet to be fully understood. This paper, using Los Angeles as a case study, highlights the importance of evaluating and refining these incentive programs to enhance EV accessibility for marginalized groups.

ADVANCED PROPULSION SYSTEMS↗

A Ce 4+ Aluminum Hydride Complex

Complexes of reducing hydride ligands by high-oxidation state cerium are unknown due to the fundamental mismatch in their redox chemistry. Herein we report the synthesis, characterization, and reactivity of the first example of a Ce 4+ aluminum hydride complex. Synthetic strategies adapted from the preparation of Ce 4+ alkyl complexes facilitated the isolation of [Ce 4+ (κ 2 -H 3 AlC(TMS) 3 )(NP( t Bu) 3 ) 3 ] (CeHAl). The bonding and structure of this complex is characterized by single-crystal XRD, NMR, and UV–vis–NIR spectroscopy, and DFT computations. The fundamental reactivity profile is evaluated by cyclic voltammetry and small-molecule reactions.

anions↗

An AI-driven framework for evaluating local and state authorities’ permitting processes

The demand for new energy infrastructure is increasing across the United States, but heterogenous permitting processes and embedded requirements across different local jurisdictions can cause project delays, increase “soft costs,” and hinder developer expansion. This study analyzes the variability in local permitting requirements across the U.S. and develops a quantitative approach to describe their clarity and effectiveness in enabling infrastructure project development. By using an Energy Language Model (ELM), a large language model (LLM) for energy technologies, we systematically gathered permitting information from nearly 300 state-, county-, and city-level documents, creating a structured dataset of requirements and procedures on an unprecedented scale and speed. Our analysis revealed that local (city and county) permitting requirement documents are underrepresented compared to state-level guidance documents, which can impede timely and cost-effective installation of new electric infrastructure. Our validation process showed that the final database has an accuracy of approximately 95%. We, further, created a new quantitative method to score permitting requirements for clarity and efficiency, with electric vehicle supply equipment as an initial use case. The average local permitting document scored a 1.8 out of 5, which we interpret as meaning that half of the requirements developers face when installing electric infrastructure are ambiguous, increasing both cost and time. We also created a “Generalized Permit Process”, highlighting common procedural steps and identifying specific opportunities for municipalities to improve their documentation. This research establishes a systematic and scalable framework for evaluating the complexities of local infrastructure permitting processes by combining LLM-powered data collection and quantitative scoring. The framework enables policymakers and developers to identify and mitigate procedural bottlenecks, with the expectation that these improvements can accelerate application review and approval, reduce project costs, and expedite connection to utility distribution grids. As a foundational approach for streamlining local project development processes, this study’s methods are intended to be extended to a wide range of energy applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Estimation of intensity, footprint, and capacity of surface urban heat islands using a direction-enhanced adaptive synchronous extraction (DEASE) method

Here, the surface urban heat island (SUHI) effect, assessed through remotely sensed land surface temperature (LST), remains a focal point in urban climate research. Conventional indicators like SUHI intensity (SUHII) and footprint (SUHIF) capture peak values and spatial extent but fail to account for the cumulative thermal load—a critical dimension reflecting the total heat exposure imposed by spatially continuous warming, which directly limits a holistic assessment of ecological and societal impacts of the SUHI effect. Therefore, this study introduces an indicator termed SUHI capacity (SUHIC), designed to quantify the aggregated SUHI effect by integrating the magnitude of the warming signal across all affected areas, thereby enabling a more comprehensive evaluation of urban thermal environments. Furthermore, a direction-enhanced adaptive synchronous extraction (DEASE) method is proposed for the quantification of SUHIC. This method can dynamically identify the optimal background reference area based on the urban-rural LST gradients in various directions within the city, without relying on predefined mathematical models as previously. The results from 102 European cities first confirm that the directional variations in urban-rural LST gradients, and the DEASE method can effectively capture these distinctions for the simultaneous estimation of SUHII, SUHIF, and SUHIC. Secondly, the spatial patterns of absolute SUHIC values show strong associations with those of SUHIF (R2>0.86), while its relative values (normalized by the area of urban) align more closely with SUHII (R2 > 0.64). More importantly, SUHIC can serve as a crucial reference for assessing the urban thermal signal when SUHII and SUHIF diverge. The proposed method and framework contribute to standardizing the quantification of the SUHI effect.

Indicator↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing environmental assessment of the circular economy: Challenges and opportunities

The lifecycle assessment (LCA) framework is widely applied to comprehensively evaluate and improve the environmental performance of a circular economy (CE). The advances and application of LCA has been primarily restricted to evaluate the environmental performance of the CE at a micro-level, wherein the CE is implemented for a single product system. However, the CE can be operationalized at two broader levels: the meso–level (for eco-industrial parks) and the macro-level (for a city, state, or nation). Six methodological challenges emerge when applying LCA to a meso- or macro-level CE and remain unaddressed in the existing literature. This includes: selecting a relevant system boundary and functional unit, addressing data paucity and uncertainty, accounting for stakeholder behavior, assessing the trade-offs from renewable energy (RE) use, accounting for manufacturing and technology evolution, and quantifying displacement and rebound. This article proposes potential solutions and research priorities to address the above challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Travel Decision Survey - San Francisco - 2013

On behalf of the San Francisco Municipal Transportation Agency (SFMTA), Corey, Canapary & Galanis undertook a Travel Decision Survey within the City and County of San Francisco, as well as the eight surrounding Bay Area counties of Alameda, Contra Costa, San Mateo, Marin, Santa Clara, Napa, Sonoma, and Solano. The primary goals of this study were to: 1. Assess percent mode share for travel in San Francisco for evaluation of the SFMTA Strategic Objective 2.3: Mode Share target of 50% non-private auto travel by FY 2018 with a 95% confidence level and margin of error ±5% or less. 2. Evaluate the above statement based on number of trips to, from, and within San Francisco by Bay Area residents. Trips by visitors to the Bay Area and for commercial purposes are not included. 3. Provide additional trip details, including trip purpose for each trip in the mode-share question series. 4. Collect demographic data on the population of Bay Area residents who travel to, from, and within San Francisco. 5. Collect data on travel behavior and opinions that support other SFMTA strategy and project evaluation needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Travel Decision Survey - San Francisco - 2014

On behalf of the San Francisco Municipal Transportation Agency (SFMTA), Corey, Canapary & Galanis undertook a Travel Decision Survey within the City and County of San Francisco, as well as the eight surrounding Bay Area counties of Alameda, Contra Costa, San Mateo, Marin, Santa Clara, Napa, Sonoma, and Solano. The primary goals of this study were to: 1. Assess percent mode share for travel in San Francisco for evaluation of the SFMTA Strategic Objective 2.3: Mode Share target of 50% non-private auto travel by FY 2018 with a 95% confidence level and margin of error ±5% or less. 2. Evaluate the above statement based on number of trips to, from, and within San Francisco by Bay Area residents. Trips by visitors to the Bay Area and for commercial purposes are not included. 3. Provide additional trip details, including trip purpose for each trip in the mode-share question series. 4. Collect demographic data on the population of Bay Area residents who travel to, from, and within San Francisco. 5. Collect data on travel behavior and opinions that support other SFMTA strategy and project evaluation needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Travel Decision Survey - San Francisco - 2015

On behalf of the San Francisco Municipal Transportation Agency (SFMTA), Corey, Canapary & Galanis undertook a Travel Decision Survey within the City and County of San Francisco, as well as the eight surrounding Bay Area counties of Alameda, Contra Costa, San Mateo, Marin, Santa Clara, Napa, Sonoma, and Solano. The primary goals of this study were to: 1. Assess percent mode share for travel in San Francisco for evaluation of the SFMTA Strategic Objective 2.3: Mode Share target of 50% non-private auto travel by FY 2018 with a 95% confidence level and margin of error ±5% or less. 2. Evaluate the above statement based on number of trips to, from, and within San Francisco by Bay Area residents. Trips by visitors to the Bay Area and for commercial purposes are not included. 3. Provide additional trip details, including trip purpose for each trip in the mode-share question series. 4. Collect demographic data on the population of Bay Area residents who travel to, from, and within San Francisco. 5. Collect data on travel behavior and opinions that support other SFMTA strategy and project evaluation needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Travel Decision Survey - San Francisco - 2017

On behalf of the San Francisco Municipal Transportation Agency (SFMTA), Corey, Canapary & Galanis undertook a Travel Decision Survey within the City and County of San Francisco, as well as the eight surrounding Bay Area counties of Alameda, Contra Costa, San Mateo, Marin, Santa Clara, Napa, Sonoma, and Solano. The primary goals of this study were to: 1. Assess percent mode share for travel in San Francisco for evaluation of the SFMTA Strategic Objective 2.3: Mode Share target of 50% non-private auto travel by FY 2018 with a 95% confidence level and margin of error ±5% or less. 2. Evaluate the above statement based on number of trips to, from, and within San Francisco by Bay Area residents. Trips by visitors to the Bay Area and for commercial purposes are not included. 3. Provide additional trip details, including trip purpose for each trip in the mode-share question series. 4. Collect demographic data on the population of Bay Area residents who travel to, from, and within San Francisco. 5. Collect data on travel behavior and opinions that support other SFMTA strategy and project evaluation needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Authentication Vulnerability Assessment of Connected Lighting Systems

Emerging connected lighting systems (CLS) that incorporate distributed intelligence, network interfaces, and sensors can become data-collection platforms that enable a wide range of valuable new capabilities as well as greater energy savings in buildings and cities. However, CLS technology is currently at an early stage of development, and its increased connectivity introduces cybersecurity risks that are new to the lighting industry and that must be addressed for successful integration with other systems. While a number of existing frameworks, guidelines, and tests for evaluating cybersecurity vulnerability may apply to CLS in whole or in part, there is currently no mandatory requirement for cybersecurity testing or certification. The lighting industry, including technology developers and specification organizations, is currently evaluating the suitability of existing frameworks and guidelines for CLS. To support these efforts, Pacific Northwest National Laboratory (PNNL) is conducting a series of studies intended to educate lighting industry stakeholders on specific cybersecurity practices and characterize their implementation in commercially available CLS with varying system architectures, network-communication technologies, and degrees of maturity. This study demonstrates that tests for authentication vulnerabilities can be developed with objective pass/fail criteria, therby facilitating comparisons between CLS. Based on the limited results of this study, it appears that the CLS that are being brought to market have varying levels of authentication vulnerability. It is hoped that these evaluations will support and perhaps accelerate industry discussions on the risks of specific security vulnerabilities, what vulnerabilities should be addressed by in-development of future lighting-specific best practices, and whether any such practices should be included in voluntary lighting standards.

42 ENGINEERING↗

USAID Colombia Young Leaders Workforce Training Program Action Plans: Planning for Electric Vehicle Charging Infrastructure in Bogotá

As part of the U.S. Agency for International Development (USAID)-National Renewable Energy Laboratory (NREL) Young Leaders Workforce Training Program in Colombia, the Grupo Energía Bogotá (GEB) participants leveraged their training and professional experience to develop an action plan for modeling and evaluating Bogotá's projected electric vehicle (EV) charging needs to meet future demand. This case study summarizes the collaboration between USAID-NREL, GEB, and the Bogotá Department of Transportation Mobility Secretariat (SDM) to estimate EV charging station needs to meet projected future EV sales in the city of Bogotá and determine high-priority locations within the greater Bogotá metropolitan area for planning and applying EVSE investment and installation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterizing Connected Lighting Systems

In the context of evaluating a lighting control system, characterization refers to the identification and description of key attributes and distinctive features of that system. NGLS has to date characterized both the form and function of 14 lighting control systems installed in the Living Lab at Parsons School of Design in New York City. The goal of NGLS characterizations in the Living Lab has been to achieve a broad understanding of “these types of systems” as a class, rather than a detailed description of any individual system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

Delineating the Effects of Counterions on the Structural and Vibrational Properties of U(IV) Lindqvist Polyoxometalate Complexes

Herein we conducted a full investigation into the fundamental structural and vibrational properties of uranium(IV) Peacock−Weakley-type lacunary Lindqvist (W 10 ) polyoxometalate (POM) complexes. We recently demonstrated the importance of the secondary lattice elements in tuning the distortion of the D 4d symmetry in W 10 POM complexes, and here, we synthesized eight UW 10 complexes with different alkali metal counterions and evaluated how the composition and packing of counterion species affected complex structural and vibrational properties. Single-crystal X-ray diffraction analysis on complexes 1−8 revealed changes in structural distortion parameters as a function of differences in counterion configurations, while far-infrared and Raman spectra for 1−8 also demonstrated that vibrational mode frequencies were sensitive to changes in counterion composition and packing. To more effectively compare different counterion configurations, we developed counterion effective ionic radius (eIR) as a new structural parameter, and comparisons between structural distortion parameters and eIR values strongly suggested that modulation by the secondary lattice elements can affect structural and vibrational manifolds within POM complexes. Partial least squares (PLS) analysis was used to quantitatively evaluate correlations observed within this investigation, and PLS statistical models showed a strong correlation between counterion eIR and both structural distortion parameters and vibrational mode frequencies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗