Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circulator pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Pressure and Circulation Data April, 2024

This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from April 3rd to April 17th, while the circulation test occurred on April 27th, 2024. Data is in excel files, with ReadMe files for each of the .zip folders that detail what data is available. Also attached here is wellhead pressure data from Pason that is referred to in the ReadMe files.

15 GEOTHERMAL ENERGY↗

Rheo–Electric Foundations and Engineering of Carbon Slurry Flow Electrodes

Flowable carbon slurry electrodes promise continuous, scalable electrochemical desalination and energy storage when their rheology (flow and stability) and electronic connectivity are jointly optimized. This report integrates six complementary thrusts that we executed under the Laboratory Directed Research and Development (LDRD) project: (i) a fast, ex situ, centrifuge-compatible method to quantify pellet (packed slurry) electronic conductivity, with a validated cell constant (“shape factor”) and quantitative structure–property insights for carbon mixtures; (ii) a controlled circulation study showing that peristaltic pumping can irreversibly alter particle size and morphology over laboratory-relevant durations; (iii) development of a miniature jet pump that preserves particle integrity while achieving entrainment ratios of 2–4 at practical flow rates; (iv) a comprehensive mapping of how a representative non-ionic surfactant (Tween 20) collapses the carbon gel network, separating network-percolation losses from intrinsic particle contact resistance; (v) in-situ visualization revealing how gravitational settling and flow-driven mixing compete to control charge transport, with dynamic bed layers preventing saturation while achieving 30-fold local concentration enhancement; and (vi) a simple, widely adoptable fabrication route to structured, gas-nitrided titanium nitride (TiN) titanium current collectors that dramatically lower interfacial losses and enable geometry-driven performance gains. Together, these results provide a coherent toolchain and design rules to accelerate formulation screening, de-risk device prototyping, and standardize characterization for carbon slurry electrodes in flow-electrode capacitive deionization (FCDI), electrochemical flow capacitor (EFC), and related systems.

25 ENERGY STORAGE↗

Comparison of spatial dynamics and point kinetics approaches in multiphysics modeling of the molten salt reactor experiment

In this work, we present validation test results of fully coupled neutronics and thermal-hydraulics models of the Molten Salt Reactor Experiment (MSRE) against experimental data of the zero power pump transients and the natural circulation tests at low power. To capture the strong coupling between neutronics and thermal-hydraulics due to fuel circulation, and to account for the delayed neutron precursor (DNP) distribution, the porous media thermal-hydraulics solver Pronghorn was fully coupled to the spatial neutron dynamics code Griffin, which solves the neutron diffusion equation, and to the 0-D point kinetics solver Squirrel, using a 2-D homogenized representation of the MSRE. The validation test results show very good agreement with experimental data for both point kinetics and spatial dynamics simulations, capturing the strong feedback effect and DNP losses in the MSRE. The 0-D code Squirrel accurately predicted the time-dependent behavior in the MSRE given the steady-state spatial dynamics solution of Griffin.

42 - ENGINEERING↗

Closed-cycle power supply for fluidic control systems

Power supply utilizes small quantities of two-phase fluid of suitable thermodynamic properties for circulation in a capillary-pumped heat transfer loop. Fluid is vaporized in evaporator, passed through fluidic system load, condensed, pumped by multistage capillary pump, and returned to the evaporator.

Fiet, O.↗

Membrane water deaerator investigation

The purpose of the membrane water deaerator program was to develop data on a breadboard hollow fiber membrane unit that removes both dissolved and evolved gas from a water transfer system in order to: (1) assure a hard fill of the EVLSS expendable water tank; (2) prevent flow blockage by gas bubbles in circulating systems; and (3) prevent pump cavitation.

Elam, J.↗

Tubular sublimatory evaporator heat sink

An evaporative refrigerator or cooler comprising a bundle of spaced, porous walled tubes closed at one of their ends and vented to a vacuum at the other end is disclosed. The tube bundle is surrounded by a water jacket having a hot water inlet distribution manifold and a cooled water outlet through a plenum chamber. Hot water is pumped into the jacket to circulate around the tubes, and when this water meets the vacuum existing inside the tubes, it evaporates thereby cooling the water in the jacket. If cooling proceeds to the point where water penetrating or surrounding all or part of the tubes freezes, operation continues with local sublimation of the ice on the tubes while the circulating water attempts to melt the ice. Both sublimation and evaporation may take place simultaneously in different regions of the device.

Webbon, B. W.↗

Capillary-Condenser-Pumped Heat-Transfer Loop

Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

Silverstein, Calvin C.↗

Nonazeotropic Heat Pump

Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

Ealker, David H.↗

Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

Spacesuit Water Membrane Evaporator - Baseline heat rejection technology for the Portable Life Support System of the Advanced EMU center dot Replaces sublimator in the current EMU center dot Contamination insensitive center dot Can work with Lithium Chloride Absorber Radiator in Spacesuit Evaporator Absorber Radiator (SEAR) to reject heat and reuse evaporated water The Spacesuit Water Membrane Evaporator (SWME) is being developed to replace the sublimator for future generation spacesuits. Water in LCVG absorbs body heat while circulating center dot Warm water pumped through SWME center dot SWME evaporates water vapor, while maintaining liquid water - Cools water center dot Cooled water is then recirculated through LCVG. center dot LCVG water lost due to evaporation (cooling) is replaced from feedwater The Independent TCV Manifold reduces design complexity and manufacturing difficulty of the SWME End Cap. center dot The offset motor for the new BPV reduces the volume profile of the SWME by laying the motor flat on the End Cap alongside the TCV.

Bue, Grant C.↗

Modernization of NASA's Johnson Space Center Chamber: A Liquid Nitrogen System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the “Great Observatories”, scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the steps performed in efforts to convert the existing the 60’s era Liquid Nitrogen System from a forced flow (pumped) process to a natural circulation (thermo-siphon) process. In addition, the paper will describe the dramatic conservation of liquid nitrogen to support the long duration thermal vacuum testing. Lastly, describe the simplistic and effective control system which results in zero to minimal human inputs during steady state conditions.

Garcia, Sammy↗

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft↗

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated Reaction Control System↗

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated↗

International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

Morton, Richard D.↗

No Moving Parts

Under a NASA SBIR (Small Business Innovative Research), Research International developed the solid state micromachined pump used for cooling electronics in space, circulation of heat transfer fluids on spacecraft, and monitoring fire and gas hazards aboard naval warships. Incorporating Lewis Research Center's pumping technology, commercial applications for this product include both detection of toxins and pollutants in coal mines, and early warning smoke detectors for industrial applications.

Source record↗

Multiphysics Modeling of an Annular Linear Induction Pump With Applications to Space Nuclear Power Systems

An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.

Kilbane, J.↗

Two-Step Multi-Physics Analysis of an Annular Linear Induction Pump for Fission Power Systems

One of the key technologies associated with fission power systems (FPS) is the annular linear induction pump (ALIP). ALIPs are used to circulate liquid-metal fluid for transporting thermal energy from the nuclear reactor to the power conversion device. ALIPs designed and built to date for FPS project applications have not performed up to expectations. A unique, two-step approach was taken toward the multi-physics examination of an ALIP using ANSYS Maxwell 3D and Fluent. This multi-physics approach was developed so that engineers could investigate design variations that might improve pump performance. Of interest was to determine if simple geometric modifications could be made to the ALIP components with the goal of increasing the Lorentz forces acting on the liquid-metal fluid, which in turn would increase pumping capacity. The multi-physics model first calculates the Lorentz forces acting on the liquid metal fluid in the ALIP annulus. These forces are then used in a computational fluid dynamics simulation as (a) internal boundary conditions and (b) source functions in the momentum equations within the Navier-Stokes equations. The end result of the two-step analysis is a predicted pump pressure rise that can be compared with experimental data.

Fission Power Systems↗

Two-Step Multi-Physics Analysis of an Annular Linear Induction Pump for Fission Power Systems

One of the key technologies associated with fission power systems (FPS) is the annular linear induction pump (ALIP). ALIPs are used to circulate liquid-metal fluid for transporting thermal energy from the nuclear reactor to the power conversion device. ALIPs designed and built to date for FPS project applications have not performed up to expectations. A unique, two-step approach was taken toward the multi-physics examination of an ALIP using ANSYS Maxwell 3D and Fluent. This multi-physics approach was developed so that engineers could investigate design variations that might improve pump performance. Of interest was to determine if simple geometric modifications could be made to the ALIP components with the goal of increasing the Lorentz forces acting on the liquid-metal fluid, which in turn would increase pumping capacity. The multi-physics model first calculates the Lorentz forces acting on the liquid metal fluid in the ALIP annulus. These forces are then used in a computational fluid dynamics simulation as (a) internal boundary conditions and (b) source functions in the momentum equations within the Navier-Stokes equations. The end result of the two-step analysis is a predicted pump pressure rise that can be compared with experimental data.

Fission Power Systems↗