Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “checklists”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Dose-Dependent Effects of Radiation Therapy on Cerebral Blood Flow, Metabolism, and Neurocognitive Dysfunction

Purpose: A prospective study was performed to formally relate dose-dependent radiologically defined changes in normal brain induced by radiotherapy (RT) to neurocognitive dysfunction in subjects with primary brain tumors. Methods and Materials: Adult patients receiving three-dimensional RT for central nervous system (CNS) tumors were enrolled. Positron emission tomography (PET) scanning and neuropsychological testing were performed before RT and 3 weeks and 6 months after treatment. Analyses were performed for correlations between changes in 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose (FDG)-PET (metabolism), {sup 15}O-PET (relative blood flow), regional radiation dose, follow-up time, and neuropsychological test scores. Results: Eleven subjects were enrolled and 6 completed follow-up studies. The PET data showed reduced FDG uptake, with average decreases of 2-6% in regions of the brain receiving greater than 40 Gy at 3 weeks' and 6 months' follow-up. The {sup 15}O-H{sub 2}O PET showed increases (<10%) at 3 weeks in relative regional blood flow in brain receiving greater than 30 Gy, but less at the 6-month follow-up studies. There were significant correlations between decreases in FDG uptake and increased scores from the Symptom Checklist-90-R, with an average increase in T score of 2 (p < 0.0001). The Wisconsin Card Sorting Test showed a significant correlation of decreased FDG uptake with increased errors and perseveration in test performance, with an average decrease in T score of 11 (p = 0.037). Conclusions: A dose-dependent response of CNS tissue was detected using FDG PET in this small number of patients. Decreases in CNS metabolism correlated with decreased performance on neuropsychological tests for problem solving, cognitive flexibility, and global measures of psychopathology. Additional research is needed to verify and define these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure Mode and Effect Analysis for Delivery of Lung Stereotactic Body Radiation Therapy

Purpose: To improve the quality and safety of our practice of stereotactic body radiation therapy (SBRT), we analyzed the process following the failure mode and effects analysis (FMEA) method. Methods: The FMEA was performed by a multidisciplinary team. For each step in the SBRT delivery process, a potential failure occurrence was derived and three factors were assessed: the probability of each occurrence, the severity if the event occurs, and the probability of detection by the treatment team. A rank of 1 to 10 was assigned to each factor, and then the multiplied ranks yielded the relative risks (risk priority numbers). The failure modes with the highest risk priority numbers were then considered to implement process improvement measures. Results: A total of 28 occurrences were derived, of which nine events scored with significantly high risk priority numbers. The risk priority numbers of the highest ranked events ranged from 20 to 80. These included transcription errors of the stereotactic coordinates and machine failures. Conclusion: Several areas of our SBRT delivery were reconsidered in terms of process improvement, and safety measures, including treatment checklists and a surgical time-out, were added for our practice of gantry-based image-guided SBRT. This study serves as a guide for other users of SBRT to perform FMEA of their own practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emotional and Behavioral Functioning After Conformal Radiation Therapy for Pediatric Ependymoma

Purpose: The standard of care for pediatric patients with ependymoma involves postoperative radiation therapy. Prior research suggests that conformal radiation therapy (CRT) is associated with relative sparing of cognitive and academic functioning, but little is known about the effect of CRT on emotional and behavioral functioning. Methods and Materials: A total of 113 patients with pediatric ependymoma underwent CRT using photons as part of their enrollment on an institutional trial. Patients completed annual evaluations of neurocognitive functioning during the first 5 years after CRT. Emotional and behavioral functioning was assessed via the Child Behavior Checklist. Results: Before CRT, emotional and behavioral functioning were commensurate with those of the normative population and within normal limits. After 5 years, means remained within normal limits but were significantly below the normative mean. Linear mixed models revealed a significant increase in attention problems over time. These problems were associated with age at diagnosis/CRT, tumor location, and extent of resection. A higher-than-expected incidence of school problems was present at all assessment points after baseline. Conclusions: The use of photon CRT for ependymoma is associated with relatively stable emotional and behavioral functioning during the first 5 years after treatment. The exception is an increase in attention problems. Results suggest that intervening earlier in the survivorship period—during the first year posttreatment—may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A critical review and meta-analysis of energy demand, carbon footprint, and other environmental impacts from carbon fiber manufacturing

The demand for carbon fibers and carbon fiber-reinforced polymers (CFRPs) is rapidly growing due to their outstanding mechanical properties and potential to enhance sustainability, particularly for lightweighting applications. However, carbon fibers are typically produced from fossil-based feedstocks, involve energy-intensive processes, and have limited options for sustainable end-of-life management or circularity. Despite these challenges, the energy demand and lifecycle environmental implications of their production remain poorly understood. Here, we conduct a critical literature review and meta-analysis of carbon fiber manufacturing, revealing significant variations in reported energy demand, carbon footprint, and lifecycle inventory data. Our analysis makes two novel contributions. First, we identify key underlying factors driving these variations. Second, we highlight that carbon fiber, far from being a homogeneous product, has grades varying substantially in mechanical properties, end-use markets, energy intensity of manufacturing processes, and therefore environmental impacts—an aspect often underrepresented in life cycle assessments. We assert that current data are insufficient for reliably evaluating environmental impacts, posing a risk of misleading decision-making. Addressing this gap requires new lifecycle inventory datasets clearly incorporating carbon fiber heterogeneity and key influencing factors identified in this study. Additionally, we propose actionable recommendations, including a checklist, to advance sustainability in the carbon fiber sector.

CED↗

Enhancing the Quality and Reliability of Machine Learning Interatomic Potentials through Better Reporting Practices

Recent developments in machine learning interatomic potentials (MLIPs) have empowered even nonexperts in machine learning to train MLIPs for accelerating materials simulations. However, reproducibility and independent evaluation of presented MLIP results is hindered by a lack of clear standards in current literature. In this Perspective, we aim to provide guidance on best practices for documenting MLIP use while walking the reader through the development and deployment of MLIPs including hardware and software requirements, generating training data, training models, validating predictions, and MLIP inference. We also suggest useful plotting practices and analyses to validate and boost confidence in the deployed models. Finally, we provide a step-by-step checklist for practitioners to use directly before publication to standardize the information to be reported. Altogether, we hope that our work will encourage the reliable and reproducible use of these MLIPs, which will accelerate their ability to make a positive impact in various disciplines including materials science, chemistry, and biology, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Minimum information about a single amplified genome (MISAG) and a metagenome-assembled genome (MIMAG) of bacteria and archaea

Here, we present two standards developed by the Genomic Standards Consortium (GSC) for reporting bacterial and archaeal genome sequences. Both are extensions of the Minimum Information about Any (x) Sequence (MIxS). The standards are the Minimum Information about a Single Amplified Genome (MISAG) and the Minimum Information about a MetagenomeAssembled Genome (MIMAG), including, but not limited to, assembly quality, and estimates of genome completeness and contamination. These standards can be used in combination with other GSC checklists, including the Minimum Information about a Genome Sequence (MIGS), Minimum Information about a Metagenomic Sequence (MIMS), and Minimum Information about a Marker Gene Sequence (MIMARKS). Community-wide adoption of MISAG and MIMAG will facilitate more robust comparative genomic analyses of bacterial and archaeal diversity.

59 BASIC BIOLOGICAL SCIENCES↗

Corrigendum: Minimum information about a single amplified genome (MISAG) and a metagenome-assembled genome (MIMAG) of bacteria and archaea

Here, we present two standards developed by the Genomic Standards Consortium (GSC) for reporting bacterial and archaeal genome sequences. Both are extensions of the Minimum Information about Any (x) Sequence (MIxS). The standards are the Minimum Information about a Single Amplified Genome (MISAG) and the Minimum Information about a Metagenome- Assembled Genome (MIMAG), including, but not limited to, assembly quality, and estimates of genome completeness and contamination. These standards can be used in combination with other GSC checklists, including the Minimum Information about a Genome Sequence (MIGS), Minimum Information about a Metagenomic Sequence (MIMS), and Minimum Information about a Marker Gene Sequence (MIMARKS). Community-wide adoption of MISAG and MIMAG will facilitate more robust comparative genomic analyses of bacterial and archaeal diversity.

59 BASIC BIOLOGICAL SCIENCES↗

Minimum Information Specification For In Situ Hybridization and Immunohistochemistry Experiments (MISFISHIE)

Herein, we present for consideration such a specification, termed “Minimum Information Specification For In Situ Hybridization and Immunohistochemistry Experiments (MISFISHIE)”. It is modelled after the MIAME (Minimum Information About a Microarray Experiment) specification for microarray experiments. The purpose of data standards like MIAME and MISFISHIE is to specify information content without specifying a format for encoding that information. The MISFISHIE standard specifies six sections of information that must be detailed for each experiment: Experimental Design, Specimens, Reporters, Staining, Imaging Data, and Image Characterizations. A general checklist is provided to quickly and efficiently establish adherence to the standard. Currently, we estimate that most articles describing gene expression localization studies, such as in situ hybridization assays, do not fully provide the minimum information needed for independent verification of results. In a small survey of 32 journal articles from the past five years, we found that nearly 90% did not meet all the requirements, although many met most of them. We propose that requiring authors to provide the minimum experimental detail about gene expression localization experiments would substantially facilitate reproducibility and interpretability of results by fellow investigators. Furthermore, inclusion of specific experimental details such as reagents and methods in publications would ultimately allow others to readily search the literature for these data items, especially given the ongoing trend towards open access full text journals.

Deutsch, Eric W↗

STREAMS guidelines: standards for technical reporting in environmental and host-associated microbiome studies

The interdisciplinary nature of microbiome research, coupled with the generation of complex multi-omics data, makes knowledge sharing challenging. The Strengthening the Organization and Reporting of Microbiome Studies (STORMS) guidelines provide a checklist for the reporting of study information, experimental design and analytical methods within a scientific manuscript on human microbiome research. Here, in this Consensus Statement, we present the standards for technical reporting in environmental and host-associated microbiome studies (STREAMS) guidelines. The guidelines expand on STORMS and include 67 items to support the reporting and review of environmental (for example, terrestrial, aquatic, atmospheric and engineered), synthetic and non-human host-associated microbiome studies in a standardized and machine-actionable manner. Based on input from 248 researchers spanning 28 countries, we provide detailed guidance, including comparisons with STORMS, and case studies that demonstrate the usage of the STREAMS guidelines. In conclusion, STREAMS, like STORMS, will be a living community resource updated by the Consortium with consensus-building input of the broader community.

59 BASIC BIOLOGICAL SCIENCES↗

Community-Driven Metadata Standards for Agricultural Microbiome Research

Accelerating the pace of microbiome science to enhance crop productivity and agroecosystem health will require transdisciplinary studies, comparisons among datasets, and synthetic analyses of research from diverse crop management contexts. However, despite the widespread availability of crop-associated microbiome data, variation in field sampling and laboratory processing methodologies, as well as metadata collection and reporting, significantly constrains the potential for integrative and comparative analyses. Here we discuss the need for agriculture-specific metadata standards for microbiome research, and propose a list of “required” and “desirable” metadata categories and ontologies essential to be included in a future minimum information metadata standards checklist for describing agricultural microbiome studies. We begin by briefly reviewing existing metadata standards relevant to agricultural microbiome research, and describe ongoing efforts to enhance the potential for integration of data across research studies. Our goal is not to delineate a fixed list of metadata requirements. Instead, we hope to advance the field by providing a starting point for discussion, and inspire researchers to adopt standardized procedures for collecting and reporting consistent and well-annotated metadata for agricultural microbiome research.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Evaluation of joint resistance in SSC Rutherford type cable splices for Torus magnet for the Jefferson Lab 12 GeV Upgrade

The Hall B 3.6-T superconducting torus magnet is being designed and built as part of the Jefferson Lab 12-GeV upgrade. The magnet consists of six trapezoidal coils connected in series, with an operating current of 3770 A. The magnet and the joints (or splices) connecting the coils are all conduction cooled by supercritical 4.6-K helium. This paper studies the design and manufacturing process of the splices made between two SSC Rutherford-type cables and discusses the tests performed to evaluate the performance of the splices under varying incident magnetic fields.

Ghoshal, Probir K.↗

Implementation of early psychosis services in Latin America: A scoping review

Abstract Aim The evidence of the effectiveness and cost‐effectiveness of early intervention for psychosis (EIP) services has motivated their implementation worldwide. However, complex interventions of such EIP services require local adaptations to successfully match population needs and cultural differences. Latin America is a heterogenous region where EIP services are progressively being adopted. Our aim is to map such initiatives in the region with a focus on implementation outcomes. Methods A scoping review following the Preferred Reporting Items for Systematic review and Meta‐Analysis extension for Scoping Reviews guidelines was conducted. International and regional databases were searched for publications describing EIP programmes in the region. Besides mapping the services, we described implementation outcomes based on the Standards for Reporting Implementation Studies Checklist. Results Ten articles describing seven EIP initiatives from the region were found. Four countries were represented: Argentina, Brazil, Chile and Mexico. The implementation outcomes reporting was heterogenous, although it was possible to ascertain EIP services are feasible and adequate for the region's context. Also, there is some evidence of effectiveness in terms of reducing hospitalizations and improving symptoms. Information about fidelity measures was scarce and there was no information about costs or cost‐effectiveness. Conclusions Only a small proportion of Latin American countries have adopted EIP services. Although these programmes seem to be feasible and effective, data on other implementation outcomes, such as fidelity, cultural appropriateness, cost‐effectiveness and affordability are not available. This might in part explain why this effective approach has not been yet scaled‐up at nationwide levels.

Aceituno, David↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.

60 APPLIED LIFE SCIENCES↗

SU-E-T-310: Targeting Safety Improvements Through Analysis of Near-Miss Error Detection Points in An Incident Learning Database

Purpose: Radiation treatment planning involves a complex workflow that can make safety improvement efforts challenging. This study utilizes an incident reporting system to identify detection points of near-miss errors, in order to guide our departmental safety improvement efforts. Previous studies have examined where errors arise, but not where they are detected or their patterns. Methods: 1377 incidents were analyzed from a departmental nearmiss error reporting system from 3/2012–10/2013. All incidents were prospectively reviewed weekly by a multi-disciplinary team, and assigned a near-miss severity score ranging from 0–4 reflecting potential harm (no harm to critical). A 98-step consensus workflow was used to determine origination and detection points of near-miss errors, categorized into 7 major steps (patient assessment/orders, simulation, contouring/treatment planning, pre-treatment plan checks, therapist/on-treatment review, post-treatment checks, and equipment issues). Categories were compared using ANOVA. Results: In the 7-step workflow, 23% of near-miss errors were detected within the same step in the workflow, while an additional 37% were detected by the next step in the workflow, and 23% were detected two steps downstream. Errors detected further from origination were more severe (p<.001; Figure 1). The most common source of near-miss errors was treatment planning/contouring, with 476 near misses (35%). Of those 476, only 72(15%) were found before leaving treatment planning, 213(45%) were found at physics plan checks, and 191(40%) were caught at the therapist pre-treatment chart review or on portal imaging. Errors that passed through physics plan checks and were detected by therapists were more severe than other errors originating in contouring/treatment planning (1.81 vs 1.33, p<0.001). Conclusion: Errors caught by radiation treatment therapists tend to be more severe than errors caught earlier in the workflow, highlighting the importance of safety checks in dosimetry and physics. We are utilizing our findings to improve manual and automated checklists for dosimetry and physics.

60 APPLIED LIFE SCIENCES↗

SU-E-T-627: Failure Modes and Effect Analysis for Monthly Quality Assurance of Linear Accelerator

Purpose: To develop and implement a failure mode and effect analysis (FMEA) on routine monthly Quality Assurance (QA) tests (physical tests part) of linear accelerator. Methods: A systematic failure mode and effect analysis method was performed for monthly QA procedures. A detailed process tree of monthly QA was created and potential failure modes were defined. Each failure mode may have many influencing factors. For each factor, a risk probability number (RPN) was calculated from the product of probability of occurrence (O), the severity of effect (S), and detectability of the failure (D). The RPN scores are in a range of 1 to 1000, with higher scores indicating stronger correlation to a given influencing factor of a failure mode. Five medical physicists in our institution were responsible to discuss and to define the O, S, D values. Results: 15 possible failure modes were identified and all RPN scores of all influencing factors of these 15 failue modes were from 8 to 150, and the checklist of FMEA in monthly QA was drawn. The system showed consistent and accurate response to erroneous conditions. Conclusion: The influencing factors of RPN greater than 50 were considered as highly-correlated factors of a certain out-oftolerance monthly QA test. FMEA is a fast and flexible tool to develop an implement a quality management (QM) frame work of monthly QA, which improved the QA efficiency of our QA team. The FMEA work may incorporate more quantification and monitoring fuctions in future.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking checklist item in the pre-treatment plan check assessment; the ramification of which will be assessed in future data.

60 APPLIED LIFE SCIENCES↗