Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A spacecraft cooling system for a charged coupled device

This paper describes the thermal analysis, design, and testing of a dedicated cooling system for a Spartan spacecraft payload. A simple reliable design that requires minimum power consumption and minimum weight was developed. The payload has a CCD detector that must be maintained at a temperature of approximately -40 C or colder. The cooling system consists of a fin radiator, dual redundant heat pipes, and a thermal electric device (TED). The system was analytically modeled through the use of the Simplified Shuttle Payload Thermal Analyzer (SSPTA) computer program. A thermal test of the system simulating flight conditions was conducted to correlate the computer model and verify performance specifications.

Walker, Mary S.↗

Charge-coupled-device response to electron beam energies of less than 1 keV up to 20 keV

Recent developments of backside treatment for the backside-illuminated scientifc CCD imagers have shown near-theoretical efficiency even at the short wavelength region of the spectrum. By using SEM performance comparisons of backside-treated and untreated CCDs to an electron flux varying from 1 to 100 pA and beam energy ranging from less than 1 keV up to 20 keV are obtained. The theoretical analysis, the SEM testing procedure, and the quantum efficiency measurement results are presented. It is shown, for example, that the average quantum efficiency increases from less than 1 percent for an untreated CCD to nearly 40 percent for a backside-treated CCD at a beam energy of 1 kev.

Daud, Taher↗

Lick Observatory charge-coupled-device data acquisition system

The Lick Observatory CCD data acquisition system is described, with some observational results to illustrate the system capability. The electronics for the CCD are subdivided into those attached to the dewar, a 'smart' controller near the dewar, and a computer connected by serial link to the smart controller. Software for the controller is in assembler code, while the software for data acquisition and on-line analysis is written in C and uses the UNIX operating system. The computers and controllers are programmed to recognize and operate several different types of CCD. Three separate instruments that use the CCDs are described briefly, together with examples of the data they produce.

Robinson, L. B.↗

High performance visible and near-infrared charge-coupled-device array for spectroscopy applications

This paper describes the design and performance of a scientific CCD array for use in NASA's Shuttle Image Spectrometer Experiment. The device is a four-phase, buried-channel CCD structure that operates in the frame-transfer mode. The sensor consists of 64 x 404 pixels, has a 100 percent fill factor, and operates in the visible and near-infrared spectral regions. In operation, the 404 horizontal elements provide spatial information, while the 64 vertical elements give spectral information covering the wavelength range of 400 to 1000 nm in 10 nm increments. The high full-well capacity of each pixel and low noise floor yield a dynamic range of more than 95 dB. In addition, the device has been designed to have good linearity characteristics. The unique dual-output structure allows a horizontal row to be read out to the right or to the left, or it can be split from the middle to both right and left output circuits simultaneously for high speed applications. The power dissipation of the device is about 60 mW.

Wang, Weng-Lyang↗

Flash technology for charge-coupled-device imaging in the ultraviolet

The introduction of the flash gate has made possible the fabrication of backside-illuminated CCDs with high sensitivity and stability throughout a wide range of ultraviolet and visible wavelengths (100 to 5000 A). It had been determined previously that the characteristics of the oxide layer beneath the gate are critical to the ultimate achievable CCD performance. However, by creating an improved oxide layer in conjunction with the flash gate, it is now possible to consistently produce CCDs with near-ideal UV performance. In this paper recent results and related background theory that optimize the flash gate specifically for application in the UV are presented.

Janesick, James R.↗

Optical tracking using charge-coupled devices

The extraction of precise positional information from CCD images of point-source and extended optical targets is considered, and three examples of CCD optical trackers for space-based operation are described. For ideal point sources, a centerfinding accuracy of 1/100 pixel and a measuremet jitter of less than 1/250 pixel have been obtained using thinned, backside-illuminated devices. Tracker accuracy is shown to be limited by small variation in the optical image shape. Techniques for tracking, and methods for searching the entire field for the desired targets, are also discussed.

Stanton, Richard H.↗

Imaging and nondispersive spectroscopy of soft X rays using a laboratory X-ray charge-coupled-device system

This paper describes the design and performance of a laboratory instrument for imaging and nondispersive spectroscopy of soft X-rays (300 eV to 10 keV) utilizing a virtual-phase CCD. This instrument has achieved a spatial resolution of 22 microns (limited by pixel size) with an overall array area of 584 x 390 pixels. It has achieved an energy resolution of about 140 eV FWHM for single-pixel Fe-55 X-ray events (5.9 keV) with the CCD operated at -30 C. The CCD has been operated in photon-counting mode at room temperature, and X-ray spectra with an energy resolution of about 450 eV at 5.9 keV have been obtained. The low energy X-ray sensitivity of the CCD also has been demonstrated by detecting carbon K-alpha X-rays (277eV).

Luppino, Gerard A.↗

Design of low noise, high performance X-ray charge-coupled-device cameras

This paper describes some of the critical details of the MIT X-ray CCD camera design. Special attention is given to those portions of the system that deviate from conventional practice in the design of CCD cameras. Furthermore, an attempt has been made to generalize the design so that both optical and X-ray requirements can be satisfied whenever possible. Currently, noise levels of less than 8 electrons rms are routinely achieved with this design, and even lower levels (less than 5 electrons) should be realizable.

Doty, J. P.↗

Charge coupled devices vs. microchannel plates in the extreme and far ultraviolet - A comparison based on the latest laboratory measurements

While microchannel plates (MCPs) have been established as imaging photon counters in the EUV and FUV for some years, CCDs are associated with low light level sensing at visible and near-IR wavelengths. Attention is presently given to recent proposals for CCDs' use as EUV and FUV detectors with quantum efficiencies sometimes exceeding those of MCPs; quantum resolution, format size, dynamic range, and long-term stability are also used as bases of comparison, for the cases of both space-based astronomical and spectroscopic applications.

Vallerga, J.↗

NASA Charge Coupled Device (CCD) Spectrometer System (NCSS)

A small lightweight NCSS was designed, constructed, and is now being bench tested at Wallops. The unit provides 256, 2.7 nm wide channels in the visible spectrum from approximately 400 to 1100 nm. The present input slit provides a spectral impulse response of about 10 nm. Up to five NCSS sensors may be bused to one data system interface. The NCSS contains a high speed, 16 bit analog to digital converter (ADC) with an integral wide-band sample-and-hold amplifier. The NCSS was developed primarily for use with the Airbone Oceanographic Lidar (AOL). A prototype NCSS is presently interfaced to the AOL. The AOL will use two new NCSS units onboard the Goddard P-3A aircraft. They will provide the AOL with high resolution sky and ocean spectra. The up-looking NCSS will provide the AOL data system (AOLDS) with down-welling solar radiance, and the down-looking NCSS will provide ocean color spectra. The solar radiance will be used to correct various ocean color algorithms now being researched.

Wright, C. W.↗

Charge-coupled device spectra of asteroids. I - Near-earth and 3:1 resonance asteroids

Main-belt asteroids and cometary nuclei are both frequently suggested sources of the relatively short-lived near-earth asteroids (NEAs). The asteroidal origin hypothesis is studied by obtaining new high-quality reflectivity spectra of 19 NEAs and 23 asteroids near the 3:1 resonance, and by performing a systematic comparison of these two groups of spectra. Nonparametric statistical tests are used to check for consistency between the color distributions of the two populations. The tests indicate that the difference between the two distributions is generally not significant at the 3 sigma level. However, this conclusion is dependent on the (unknown) size distribution of the NEAs. The observations are compatible with the hypothesis that the NEAs are derived from the 3:1 resonance region, but do not imply that this is the only possible source region.

Luu, Jane X.↗

New advancements in charge-coupled device technology - Sub-electron noise and 4096 x 4096 pixel CCDs

This paper reports on two new advancements in CCD technology. The first area of development has produced a special purpose CCD designed for ultra low-signal level imaging and spectroscopy applications that require sub-electron read noise floors. A nondestructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are reported. The second development involves the design and performance of a high resolution imager of 4096 x 4096 pixels, the largest CCD manufactured in terms of pixel count. The device utilizes a 7.5-micron pixel fabricated with three-level poly-silicon to achieve high yield.

Janesick, James R.↗

Open-Pinned-Phase Charge-Coupled Device

Acceptable quantum efficiency obtained without back illumination and back-side thinning. NEW CCD technology referred to as "open-pinned-phase" (OPP) invented to unite best attributes of multiphase and virtual-phase technologies. Delivers high front-side sensitivity in conjunction with ultralow-signal-level performance.

Janesick, James R.↗

Scanning with charge-coupled devices

Results are presented of an investigation of six modes of using CCDs for searches of gamma-ray bursters, debris in geosynchronous space, satellites of asteroids, brown dwarfs, the tenth planet, comets, cometesimals, and various types of asteroids. A new discipline in astrophysics, 'scannerscopy', i.e., surveying with a CCD rather than with photography at a Schmidt telescope, is described. It uses the CCD in scanning rather than in sequencing of stare exposures as is done at most observatories, which can save telescope time and obviates the need for flat-fielding. Attention is given to the Tektronix 2048 x 2048 CCD, 38 arcmin wide, which is used to a limiting magnitude of 20.5 V. It is also shown to be successful for discovering rare and small near-earth asteroids. Possibilities with cameras on spacecraft that pass through the asteroid belt are described.

Gehrels, Tom↗

Charge coupled devices (CCDs) in X-ray astronomy

The application of CCDs to X-ray imaging and spectroscopy in astronomy is discussed with special attention given to the special requirements of CCDs for X-ray astronomy (as opposed to those for traditional optical applications). The development status of CCDs for X-ray astronomy applications is described, and results of recent research in the area of optimizing the CCD X-ray response are presented. It is shown that very high quantum efficiencies and Fano noise-limited energy resolutions can be obtained using CCDs.

Lumb, D. H.↗

Charge-coupled device imaging spectroscopy of Mars. II - Results and implications for Martian ferric mineralogy

Materials similar to nanophase ferric oxides are presently seen to dominate the spectral behavior of the Martian surface in the visible-to-near-IR, in view of imaging spectroscopic observations of Mars. Attention is accordingly given to models for the formation of hematite and other ferric minerals in both current terrestrial environments and in the current and past, possibly wetter Martian climate. It is noted that imaging spectroscopy is an ideal tool for high spatial resolution spacecraft and telescopic studies of the Martian surface.

Bell, James F., III↗

Development of a large pixel, spectrally optimized, pinned photodiode/interline charge coupled device (CCD) detector for the Earth Observing System (EOS)/Moderate-Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument

A pinned photodiode/interline CCD Detector Array is under development for the EOS/MODIS-T project. Outstanding features of the device include large pixels, spectrally optimized fill factors, and blooming protection. The detector has 30 spatial rows and 32 spectral columns. The device layout is split into two halves; each half has its own detector area, storage area, and output structure.

Ewin, Audrey J.↗

Charge-coupled device imaging spectroscopy of Mars. I - Instrumentation and data reduction/analysis procedures

This paper describes the collection, reduction, and analysis of 0.4-1.0-micron Mars imaging spectroscopy data obtained during the 1988 and 1990 oppositions from Mauna Kea Observatory and provides a general outline for the acquisition and analysis of similar imaging spectroscopy data sets. The U.H. 2.24-m Wide Field Grism CCD Spectrograph was used to collect 13 3D image cubes covering 90 percent of the planet south of 50 deg N in the 0.4-0.8 micron region and covering 55 percent of the planet south of 50 deg N in the 0.5-1.0 micron region. Spectra extracted from these image cubes reveal the detailed character of the Martian near-UV to visible spectrum. Images at red wavelengths reveal the 'classical' albedo markings at 100-500 km spatial resolution while images at blue wavelengths show little surface feature contrast and are dominated by condensate clouds/hazes and polar ice.

Bell, James F., III↗