Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impact of Testing Method on Safety Assessment of Aged Li-Ion Cells: Part II – Aged Cells Without Li Plating

Understanding the safety profile of aged Li-ion batteries is essential for developing effective battery management and hazard mitigation strategies. However, most safety assessments have focused on fresh batteries, with just a few calorimetry studies on aged batteries with metal oxide positive electrodes. This study provides a broad assessment of commercial 18650-type Li-ion batteries with NCA, NMC, and LFP positive electrodes, both uncycled and aged under conditions that promoted solid electrolyte interphase (SEI) growth as the dominant degradation mechanism. The cells underwent mechanical (nail penetration, crush), electrical (overcharge, overdischarge), and thermal (accelerating rate calorimetry) abuse tests. Safety was rated on general characteristics such as mass loss, maximum temperature, and EUCAR (European Council for Automotive R&D) hazard level, as well as characteristics specific to individual abuse tests. Generally, aged cells with SEI growth exhibited similar or improved safety compared to uncycled cells, contrasting with our previous findings on NCA cells with Li plating as the dominant aging mechanism (Part I of this series). Yet, some tests and characteristics indicated reduced aged cell safety, such as earlier triggering of mechanical failure. These results emphasize the need to examine aged battery safety across diverse empirical techniques, degradation modes, and chemistries.

Lithium-ion cells↗

Mechanical Unloading Effects Hematopoiesis and Subsequent Red Blood Cell Life Cycle Evaluated at Singe Cell Resolution

Red blood cell formation or erythropoiesis in the bone marrow and exit into circulation are known to be affected by mechanical loading. Specifically, space anemia is a condition observed during prolonged microgravity unloading in which the red blood cell (RBC) mass in circulation is reduced. However, the mechanisms causing space anemia are yet to be clearly established, but may include increased hemolysis of RBC in circulation, decreased RBC production or a combination of both factors. The presentation of space anemia is comparable to chronic anemia conditions associated with aging, disuse, and poor health. Molecular dysregulation in the RBC's life cycle is poorly defined and is a significant concern in the context of disuse anemia as mechanotransduction significantly alters of gene expression, protein synthesis and cell signaling pathways. Our study analyzes mouse single cell RNA sequencing libraries from the bone marrow, circulating blood, and spleen and integrates the RBC lineage populations from the tissues into a RBC life cycle atlas. This study also probes how age at time of spaceflight contributes to the molecular signature of space anemia. The overarching objective of the study is to develop a mechanistic understanding of space anemia and translate the findings to a better understanding of aging, disuse, and poor health-related anemia to defining the role of mechanical loading in health and devise potential therapeutic interventions. Important findings of our study are: 1) that mechanical unloading in microgravity alters the proportion of developmental RBC lineage cells, skewing toward progenitor, indicating that fewer RBCs may be present in blood; 2) that late reticulocyte number is elevated in the bone marrow of older animals, suggesting a failure to enter circulation; and 3) that the molecular signature of the circulating RBCs is not significantly altered in microgravity. However, expression markers for eryptosis and erythrophagocytosis are elevated in circulating and spleen RBCs, suggesting spaceflight may shorten the lifetime of RBCs after exit from the marrow. In conclusion our results suggest early stages of erythropoiesis proliferation and differentiation in the marrow are key factors in space anemia and mechanical loading may be a necessary step of RBC entry in circulation.

blood↗

Linking DSC/TGA to Cell Levels: Energetics, Evolved Gases, and Thermal Safety of NMC811‐Graphite Micro‐Cell

Thermochemical characterization of battery materials links intrinsic material properties to decomposition pathways, heat generation, and gas evolution that govern performance and safety. Despite extensive work on NMC811-Graphite, variability across partial configurations and the limited adoption of micro-cell architectures (cathode+anode+electrolyte+separator) hinder robust cell-scale interpretation. Accordingly, this work establishes a bottom-up, component-resolved methodology integrating DSC/TGA, evolved gas analysis (EGA), and in situ XRD to link decomposition pathways and energy release across partial and micro-cell configurations, providing a transferable assessment of safety and stability in emerging chemistries. In separator-free configurations, the gas–solid reaction between cathode-evolved O 2 and anode-leached Li dominates the net heat release (1139 J g −1 ). In contrast, in the micro-cell configuration, the separator hinders O 2 transport and alters the timing and pathways of other reactions, and reduces the net energy release to 618 J g −1 . Energy release was organized into defined temperature windows that provide a framework for a thermodynamic model combining quantified gas evolution with selected decomposition pathways and effective reaction enthalpies to estimate net specific energy release, with agreement between DSC and cell-level tests. Ex situ XPS of heat-treated samples extends post-mortem analysis to thermal-abuse regimes, supporting key pathway elements.

25 ENERGY STORAGE↗

Evaluation program for secondary spacecraft cells. Initial evaluation tests of Eagle-Picher Industries, Incorporated 3.0 ampere-hour nickel-cadmium spacecraft cells

The capacity of the cells ranged from 3.58 to 3.97 amperehours during the three capacity tests. Three cells were removed from test, due to high pressure, during the C/10, 24-hour charge at room ambient temperature. The voltage requirement of 1.480 volts was exceeded by the cells during the C/10, 24-hour charge at 20 C, although the end-of-charge voltage was below this value (1.466-1.475 volts). Average capacity out during the 20 C charge efficiency test was 0.84 AH which represents 48% and is below the minimum requirement of 55%. The cells exhibited no pressure decay during the open-circuit stand portion of the pressure versus capacity test, as all cells reached their voltage limit (1.550 volts) before their pressure reached 20 psia with the highest pressure being 8 psia during charge.

Harkness, J. D.↗

Results from the IMP-J violet solar cell experiment and violet cell balloon flights

The IMP-J violet solar cell experiment was flown in an orbit with mild thermal cycling and low hard particle radiation. The results of the experiment show that violet cells degrade at about the same rate as conventional cells in such an orbit. Balloon flight measurements show that violet solar cells produce approximately 20% more power than conventional cells.

Gaddy, E. M.↗

Results from the IMP-J violet solar cell experiment and violet cell balloon flights

The Interplanetary Monitoring Platform-J violet solar cell experiment was flown in an orbit with mild thermal cycling and low hard-particle radiation. The results of the experiment show that violet cells degrade at about the same rate as conventional cells in such an orbit. Balloon flight measurements show that violet solar cells produce approximately 20% more power than conventional cells.

Gaddy, E. M.↗

Sensitivity of solar-cell performance to atmospheric variables. 2: Dissimilar cells at several locations

Several solar cells having dissimilar spectral response curves and cell construction were measured at various locations in the United States to determine sensitivity of cell performance to atmospheric water vapor and turbidity. The locations selected represent a broad range of summer atmospheric conditions, from clear and dry to turbid and humid. Cell short circuit current under direct normal incidence sunlight, the intensity, water vapor and turbidity were measured. Regression equations were developed from the limited data base in order to provide a single method of prediction of cell current sensitivity to the atmospheric variables.

Klucher, T. M.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company, 6.0 ampere-hour nickel-cadmium spacecraft cells for the GOES-D, E and F satellite program

The tests are to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are referenced to normally expected values based on past performance of aerospace nickel-cadmium cells with demonstrated life characteristics. Recommendations for the improvement of the manufacturing processes are presented.

Harkness, J. D.↗

NASA Redox cell stack shunt current, pumping power, and cell performance tradeoffs

The NASA Redox energy storage system is under active technology development. The hardware undergoing laboratory testing is either 310 sq. cm. or 929 sq. cm. (0.33 sq. ft. or 1.0 sq. ft. per cell active area with up to 40 individual cells connected to make up a modular cell stack. This size of hardware allows rather accurate projections to be made of the shunt power/pump power tradeoffs. The modeling studies that were completed on the system concept are reviewed along with the approach of mapping the performance of Redox cells over a wide range of flow rates and depths of discharge of the Redox solutions. Methods are outlined for estimating the pumping and shunt current losses for any type of cell and stack combination. These methods are applicable to a variety of pumping options that are present with Redox systems. The results show that a fully developed Redox system has acceptable parasitic losses when using a fixed flow rate adequate to meet the worst conditions of current density and depth of discharge. These losses are reduced by about 65 percent if variable flow schedules are used. The exact value of the overall parasitics will depend on the specific system requirements of current density, voltage limits, charge, discharge time, etc.

Hagedorn, N.↗

The effect of cell design and test criteria on the series/parallel performance of nickel cadmium cells and batteries

Three batteries were operated in parallel from a common bus during charge and discharge. SMM utilized NASA Standard 20AH cells and batteries, and LANDSAT-D NASA 50AH cells and batteries of a similar design. Each battery consisted of 22 series connected cells providing the nominal 28V bus. The three batteries were charged in parallel using the voltage limit/current taper mode wherein the voltage limit was temperature compensated. Discharge occurred on the demand of the spacecraft instruments and electronics. Both flights were planned for three to five year missions. The series/parallel configuration of cells and batteries for the 3-5 yr mission required a well controlled product with built-in reliability and uniformity. Examples of how component, cell and battery selection methods affect the uniformity of the series/parallel operation of the batteries both in testing and in flight are given.

Halpert, G.↗

Calibration of solar cells by the reference cell method - The spectral mismatch problem

The calibration of solar cells by means of solar simulators and calibrated reference cells has always been faced with the problem of errors due to source spectral irradiance mismatch and cell spectral response mismatch. A general expression is derived in this paper to enable calculation of mismatch error. The information required to make this calculation is the relative spectra responses of the test and reference cells, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar standard is assumed given. Experimental results are presented.

Seaman, C. H.↗

Impedance studies of Ni/Cd and Ni/H cells using the cell case as reference electrode

Many impedance studies were carried out on Ni electrodes and Ni/Cd and Ni/H batteries. In order for impedance to become a diagnostic tool, accurate and reproducible measurements must be made, and some way of separating the contributions of the individual electrodes must be found. Using the PAR and the Solartron impedance equipment, studies have found that consistent measurements can be made if the cells or electrodes are equilibrated at the voltage of interest. In the charged state, equilibration times required are short, on the order of a few hours or less, but the equilibration time required becomes progessively longer as the voltage is lowered. The cell case can be used as a reference electrode during impedance measurements. The voltage of the case with respect to the electrodes is unimportant provided that it does not change appreciably during the course of the measurement. Measurements were made with several uncycled Ni/Cd cells, one from a lot which was known to have faulty Cd electrodes and another from a lot which showed excellent cycle life and presumably had good Cd electrodes. The impedances of the Ni electrodes vs. the case were similar, while the impedance of the poor Cd electrodes vs. the case. A 50 AH Ni/H cell was also investigated. After subtraction of the ohmic resistances, the sums of the impedances of the individual electrodes were very close to the impedance of the total cell. This indicates that the method is valid for examining the characteristics of the individual electrodes in situ.

Reid, Margaret A.↗

An advanced space photovoltaic concentrator array using Fresnel lenses, gallium arsenide cells, and prismatic cell covers

The current status of a space concentrator array which uses refractive optics, gallium arsenide cells, and prismatic cell covers to achieve excellent performance at a very low array mass is documented. The prismatically covered cells have established records for space cell performance (24.2 percent efficient at 100 AM0 suns and 25 C) and terrestrial single-junction cell performance (29.3 percent efficient at 200 AM1.5 suns and 25 C).

O'Neill, Mark J.↗

Graded-bandgap AlGaAs solar cells for AlGaAs/Ge cascade cells

Some p/n graded-bandgap Al(x)Ga(1-x)As solar cells were fabricated and show AMO conversion efficiencies in excess of 15 percent without antireflection (AR) coatings. The emitters of these cells are graded between 0.008 is less than or equal to x is less than or equal to 0.02 during growth of 0.25 to 0.30 micron thick layers. The keys to achieving this performance were careful selection of organometallic sources and scrubbing oxygen and water vapor from the AsH3 source. Source selection and growth were optimized using time-resolved photoluminescence. Preliminary radiation-resistance measurements show AlGaAs cells degraded less than GaAs cells at high 1 MeV electron fluences, and AlGaAs cells grown on GaAs and Ge substrates degrade comparably.

Timmons, M. L.↗

Effect of Flow on Gene Regulation in Smooth Muscle Cells and Macromolecular Transport Across Endothelial Cell Monolayers

Endothelial cells line all of the vessels of the circulatory system, providing a non-thrombogenic conduit for blood flow; they regulate many complex functions in the vasculature, such as coagulation, fibrinolysis, platelet aggregation, vessel tone and growth, and leukocyte traffic; and they form the principal barrier to transport of substances between the blood and the surrounding tissue space. The permeability of endothelial cell changes with environmental stimuli; shear stress, in particular, applied either in vivo, or in vitro, induces changes in protein expression and secretion of vasoactive factors by endothelial cells. The ability to study the effects of shear on the macromolecular permeability of the cerebral vasculature is particularly important, since in no other place is the barrier function of the endothelium more important than in the brain. The endothelial cells of this organ have developed special barrier properties that keep the cerebral system from experiencing any drastic change in composition; together with glial cells, they form the blood brain barrier (BBB). We have studied the effect of flow on bovine BBB using flow chambers and tissue culture systems.

McIntire, Larry V.↗

Effects of AEA Cell-Bypass-Switch Closure on Charged EOS-Aqua NiH2 Cell

The nominal performance of AEA CBPD under simulated EOS-Aqua/Aura flight hardware configuration has been demonstrated. There is no evidence of cell rupture or excessive heat production during or after CBPD switch activation under simulated high cell impedance (open-circuit cell failure mode). Inadvertent CBPD switch activation with a charged cell (low impedance path) intermittently closes and opens up the switch, therefore the device may or may not provide protection against future open-circuit cell failure. Further testing with switches F01 and F02 may provide clarification. The formation of a continuous low impedance path (a homogeneous low melting point alloy), has been confirmed - which is the expected mode of operation.

Keys, Denney↗

The potato virus X TGBp2 protein association with the endoplasmic reticulum plays a role in but is not sufficient for viral cell-to-cell movement

Potato virus X (PVX) TGBp1, TGBp2, TGBp3, and coat protein are required for virus cell-to-cell movement. Plasmids expressing GFP fused to TGBp2 were bombarded to leaf epidermal cells and GFP:TGBp2 moved cell to cell in Nicotiana benthamiana leaves but not in Nicotiana tabacum leaves. GFP:TGBp2 movement was observed in TGBp1-transgenic N. tabacum, indicating that TGBp2 requires TGBp1 to promote its movement in N. tabacum. In this study, GFP:TGBp2 was detected in a polygonal pattern that resembles the endoplasmic reticulum (ER) network. Amino acid sequence analysis revealed TGBp2 has two putative transmembrane domains. Two mutations separately introduced into the coding sequences encompassing the putative transmembrane domains within the GFP:TGBp2 plasmids and PVX genome, disrupted membrane binding of GFP:TGBp2, inhibited GFP:TGBp2 movement in N. benthamiana and TGBp1-expressing N. tabacum, and inhibited PVX movement. A third mutation, lying outside the transmembrane domains, had no effect on GFP:TGBp2 ER association or movement in N. benthamiana but inhibited GFP:TGBp2 movement in TGBp1-expressing N. tabacum and PVX movement in either Nicotiana species. Thus, ER association of TGBp2 may be required but not be sufficient for virus movement. TGBp2 likely provides an activity for PVX movement beyond ER association.

NASA Discipline Plant Biology↗

Comparison of Genotoxic Damage in Monolayer Cell Cultures and Three-Dimensional Tissue-Like Cell Assemblies

Assessing the biological risks associated with exposure to the high-energy charged particles encountered in space is essential for the success of long-term space exploration. Although prokaryotic and eukaryotic cell models developed in our laboratory and others have advanced our understanding of many aspects of genotoxicity, in vitro models are needed to assess the risk to humans from space radiation insults. Such models must be representative of the cellular interactions present in tissues and capable of quantifying I genotoxic damage. Toward this overall goal, the objectives of this study were to examine the effect of the localized microenvironment of cells, cultured as either 2-dimensional (2D) monolayers or 3-dimensional (3D) aggregates, on the rate and type of genotoxic damage resulting from exposure to iron charged particles, a significant portion of space radiation. We used rodent transgenic cell lines containing 50-70 copies of a LacI transgene to provide the enhanced sensitivity required to quantify mutational frequency and type in the 1,100-bp LacI target as well as assessment of DNA,damage to the entire 45-kbp construct. Cultured cells were exposed to high-ener~ir on charged particles at Brookhaven National Laboratory s Alternating Gradient Synchrotron facility for a total dose of 0, 0.1, 0.25,0.5, 1.0, or 2.0 Gy and allowed to recover for 0, 1, or 7 days, after which mutational type and frequency were evaluated. The mutational frequency was found to be higher in 3D samples than in 2D samples at all radiation doses. Mutational frequency also was higher at 7 days after irradiation than immediately after exposure. DNA sequencing of the mutant targets revealed that deletional mutations contributed an increasingly high percentage (up to 27%) of all mutations in cells as the dose was increased from 0.5 to 2 Gy. Several mutants also showed large and complex deletions in multiple locations within the Lac1 target. However, no differences in mutational type were found between the 2D and the 3D samples. These 3D tissue-like model systems can reduce the uncertainty involved in extrapolating risk between in vitro cellular and in vivo models.

Behravesh, E.↗