Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capital costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Techno-economic evaluation of emission control configurations for AMP/PZ-based post-combustion CO 2 capture

Minimizing the environmental impacts of amine-based post-combustion carbon capture technologies is essential for regulatory compliance and public acceptance. Experimental campaigns at RWE's CO 2 capture pilot plant in Niederaussem using CESAR1 demonstrated that combining existing emission abatement technologies can substantially reduce the concentration of amines and degradation products in the CO 2 -depleted flue gas to below the detection limit of an infrared spectrometer. The campaign confirmed that a proprietary dry bed technology (OEASE aerozone™) or a second water wash can reduce AMP and PZ emissions to below 1 mg/Nm 3 . However, an acid or chemically active wash downstream of the water wash is necessary to reduce NH 3 emissions to very low levels (<2 mg/Nm 3 ). Combining a dry bed with an acid wash significantly reduces both the required acid solution and the resulting acid waste. The techno-economic analysis indicates that implementing emission mitigation technologies provides substantial environmental benefits for the CESAR1 process, with only a marginal increase (<1 €/tCO 2 ) in both the carbon capture cost (CCC) and CO 2 avoidance cost (CAC). The additional capital cost associated with extra column packing is offset by operational cost savings from reduced solvent losses. For stringent emission permits targeting NH 3 , a configuration combining a dry bed upstream of the water wash followed by an acid wash achieves the best balance between emission control and cost efficiency. This configuration results in a Levelized Cost of Electricity (LCOE) of 143 €/MWh, a CCC of 45.4 €/tCO 2 , and a CAC of 88.4 €/tCO 2 .

AMP↗

Technoeconomic Analysis of the Electrochemically Mediated Amine Regeneration CO 2 Capture Process

The electrochemically mediated amine regeneration (EMAR) process presents an alternative route to the conventional thermal amine regeneration for carbon capture from a flue gas source. In this study, we conducted an economic analysis on the EMAR system for postcombustion CO2 capture from a 550 MWe power plant capturing 3.1 MtCO2 annually and from a mini steel mill with annual capture close to 170 ktCO2. We followed the recommendation of the National Energy Technology Laboratory (NETL) 2010 report to estimate the cost of CO2 avoided ([$/tCO2]). Detailed cost modeling of the electrochemical separation stage was conducted. This is integrated with the entire process flowsheet (e.g., including absorber, compressor, pumps, and other auxiliary equipment). Here, we identified the membrane cost as the dominant capital cost for the electrochemical separation train. At a membrane unit price of less than 10/m2, the CO2 capture cost can be reduced to below 50/tCO2 with optimized process conditions (e.g., desorption pressure and utilization of waste heat). Improvements in process design, cell construction, and solvent formulation may lead to additional reductions in the CO2 capture cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The value of long-duration energy storage under various grid conditions in a zero-emissions future

Long-duration energy storage (LDES) is a key resource in enabling zero-emissions electricity grids but its role within different types of grids is not well understood. Using the Switch capacity expansion model, we model a zero-emissions Western Interconnect with high geographical resolution to understand the value of LDES under 39 scenarios with different generation mixes, transmission expansion, storage costs, and storage mandates. We find that a) LDES is particularly valuable in majority wind-powered regions and regions with diminishing hydropower generation, b) seasonal operation of storage becomes cost-effective if storage capital costs fall below US$\$$5 kWh −1 , and c) mandating the installation of enough LDES to enable year-long storage cycles would reduce electricity prices during times of high demand by over 70%. Given the asset and resource diversity of the Western Interconnect, our results can provide grid planners in many regions with guidance on how LDES impacts and is impacted by energy storage mandates, investments in LDES research and development, and generation mix and transmission expansion decisions.

25 ENERGY STORAGE↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Energy Cost Estimates for Net Zero World Initiative

This report provides recommended parameters for incorporating nuclear energy systems into decarbonization modeling scenarios. The values are primarily intended for the Net Zero World (NZW) Initiative but are expected to prove useful to other related efforts. Both costs and operational metrics are provided in the study. Several cost factors, namely overnight capital costs (OCC) and operational costs are taken to be country specific. OCC is defined as the value of building the reactor in one night considering all costs prior to the start of operations including fuel for the initial core load. The value assumes the build is neither a first nor a ‘Nth’ of a kind, but somewhere in between. All costs are escalated to 2022 USD values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Summary and evaluation of the parametric study of potential early commercial MHD power plants (PSPEC)

Two parallel contracted studies were conducted. Each contractor investigated three base cases and parametric variations about these base cases. Each contractor concluded that two of the base cases (a plant using separate firing of an advanced high temperature regenerative air heater with fuel from an advanced coal gasifier and a plant using an intermediate temperature metallic recuperative heat exchanger to heat oxygen enriched combustion air) were comparable in both performance and cost of electricity. The contractors differed in the level of their cost estimates with the capital cost estimates for the MHD topping cycle and the magnet subsystem in particular accounting for a significant part of the difference. The impact of the study on the decision to pursue a course which leads to an oxygen enriched plant as the first commercial MHD plant is described.

Staigner, P. J.↗

MADE3D: Enabling the Next-Generation High-Torque- Density Wind Generators by Additive Design and 3D Printing

Direct-drive wind turbine generators are increasing in popularity, thanks to recent project developments - especially offshore, where reliability and efficiency are major cost drivers. Yet, high capital costs are forcing many original equipment manufacturers to consider lightweight, high-torque density generators for next-generation multi-megawatt turbines that may be difficult to realize by traditional design or manufacturing methods. In this study, we present a new design framework enabled by advanced machine learning and multimaterial additive manufacturing to perform a magnetic topology optimization that maximizes the torque per rotor active mass for a 15-megawatt direct-drive permanent magnet wind generator. A comparison of the proposed approach against conventional topology optimization demonstrated a significant increase in computational efficiency and accuracy in performance predictions. Results using single and multimaterial compositions for rotor core and magnets identify a wider choice of 3D printable designs for a given specification. A hybrid combination of sintered and dysprosium-free polymer-bonded magnets shows good potential for torque performance by saving material costs up to 8.75%. More than 30% improvement in rotor torque densities is identified which can marginally improve the overall generator torque density. With the rapid evolution of multipowder deposition technologies, this study can greatly inspire a new paradigm for design-driven manufacturing with novel material compositions and lightweight, low-cost, high-strength multimaterial geometries that were previously unexplored for direct-drive generators.

3D printing↗

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗

Magnetohydrodynamics MHD Engineering Test Facility ETF 200 MWe power plant. Conceptual Design Engineering Report CDER. Volume 3: Costs and schedules

The estimated plant capital cost for a coal fired 200 MWE electric generating plant with open cycle magnetohydrodynamics is divided into principal accounts based on Federal Energy Regulatory Commision account structure. Each principal account is defined and its estimated cost subdivided into identifiable and major equipment systems. The cost data sources for compiling the estimates, cost parameters, allotments, assumptions, and contingencies, are discussed. Uncertainties associated with developing the costs are quantified to show the confidence level acquired. Guidelines established in preparing the estimated costs are included. Based on an overall milestone schedule related to conventional power plant scheduling experience and starting procurement of MHD components during the preliminary design phase there is a 6 1/2-year construction period. The duration of the project from start to commercial operation is 79 months. The engineering phase of the project is 4 1/2 years; the construction duration following the start of the man power block is 37 months.

Source record↗

NE-COST plug-in: Expanding ACCERT's Capabilities for Life-Cycle Cost Modeling

The Algorithm for the Capital Cost Estimation of Reactor Technologies (ACCERT) is a structured methodology and software tool designed to simplify and standardize cost estimation for nuclear reactor technologies [1]. By utilizing a relational database structure and modular cost estimation algorithms, ACCERT delivers a robust, flexible, and scalable framework for evaluating costs across various reactor types and configurations [2]. The recent integration of the NE-COST plugin further expands ACCERT’s scope by introducing detailed life-cycle cost modeling and probabilistic analysis of uncertainties. This addition enables users to evaluate costs across front-end processes such as uranium enrichment and fabrication, as well as back-end activities including waste disposal and geologic storage. Through Monte Carlo statistical cost simulations, the plugin provides probabilistic insights into cost ranges, offering critical decision-making support for stakeholders including reactor developers, policymakers, and researchers.

Zhou, Jia↗

Conceptual range estimation for total cost of ownership of modular process‐intensified chemical plants

Abstract Chemical companies have used modularization to reduce capital costs and project timelines, putting capital to work faster and lowering the risk of entering new markets. Nevertheless, the impacts of using modularization along with advanced technologies, such as process intensification, have not yet been fully realized, often due to the uncertain business risks associated with their implementation. Therefore, new methods are needed for quantifying the impact of modular chemical process intensification (MCPI) on the capital and operating costs of chemical plants to help build a business case for this novel approach. This article presents a new conceptual range estimation technique for total cost of ownership that addresses the deficiencies of existing methods for quantifying MCPI impacts. The incorporation of percentage range estimates was employed to allow for adaptability across various cost and size scales. This work also begins to elucidate how chemical engineering and construction firms can benefit from MCPI and identifies barriers that inhibit MCPI applications in the chemical industry.

Alhamouri, Khaled I.↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

Finite Element Analysis and Techno-economic Modeling of Solar Silicon Molten Salt Electrolysis

A new process is presented for low-cost one-step production of pure solid silicon from natural quartzite by molten salt electrolysis. At a process temperature of 1100°C, a techno-economic model including detailed mass and energy balances estimates energy consumption below 15 kWh/kg, with operating cost of $\$1.74$/kg and capital cost around $\$10,500$ per t/a (tonne annually) of production capacity for a 160,000 t/a plant. Use of an inert solid oxide membrane anode results in a pure oxygen by-product and no direct emissions. As a result, finite element analysis estimates the current density distribution and total current to inform the design of slab-shaped solid silicon cathodes.

14 SOLAR ENERGY↗

Chapter 10 - Economic Considerations for Hydrogen Production with a Focus on Polymer Electrolyte Membrane Electrolysis

This Chapter provides an overview of key economic considerations for hydrogen produced from water electrolysis, with the analyses presented here ranging from high-level summaries to detailed considerations of key market and technological drivers. As the electric power sector evolves to account for increasing shares of renewable energy, opportunities are emerging for technologies capable of storing renewable energy in various forms, including as hydrogen. Opportunities for reducing the cost of hydrogen produced from electrolysis include ensuring access to low-cost wholesale electricity, reducing the capital cost of electrolyzers, and development of systems capable of being dispatchable loads without experiencing significant efficiency penalties throughout lifetime. Our analysis indicates that numerous pathways exist for making hydrogen from electrolysis cost-competitive with hydrogen produced from conventional technologies, and significant opportunities exist for research and development to address performance targets for the future electrolysis systems envisioned here.

cost reduction↗

Techno-Economic Analysis of Recycling Strategies for Catalyst and Acid During Catalytic Graphitization

With the aim of meeting the urgent demand for active anode materials (AAM) in energy storage systems, bio-based graphite (biographite) emerges as an affordable solution to de-risk the turbulent supply chain of critical minerals. Anode grade biographite requires high crystallinity and purity, which can be achieved by catalytic graphitization with iron, followed by acid washing. Therefore, a well-conceived process integration that recycles catalyst can be the starting point to commercialization. This study evaluates closed-loop catalyst recovery, and byproducts valorization scenarios through a technoeconomic framework to help understand the scale-up potential of biographite. For the acid washing, three reactors in series meet the required biographite purity at 99.95%. Iron and acid recovery can reduce material consumption and waste generation by ~95%, albeit at the expense of ~80% increase in capital costs. Recovery scenarios present similar capital and operational expenses, yielding minimum selling prices (MSP) near $6 kg-1 of biographite. Monte Carlo methodology reveals that feedstock price accounts for ~60% of MSP variance, followed by plant capacity ~20%. The likelihood of reaching a competitive profit margin of 30% in the U.S. AAM market sits at 85% average for recovery scenarios, and 103% when iron oxide is sold as byproduct. Additionally, an IRR >= 15% can be achieved for half of Monte Carlo simulations, representing promising early-stage results. Biographite production offers a strategic pathway to stabilize the anode market beyond China by integrating established technologies for a scalable, economically viable, and sustainable process. The role of catalyst recovery and byproducts utilization is critical for advancing the biomaterials industry.

97 MATHEMATICS AND COMPUTING↗

Cost analysis of hydrogen production by high-temperature solid oxide electrolysis

In this study, we estimate construction and operation costs of gigawatt-scale solid oxide electrolysis (SOE) facilities for producing high purity hydrogen gas from water. Manufacturing and assembly costs for two types of SOE cell stacks are estimated using a detailed design for manufacture and assembly (DFMA®) analysis. Modular balance of plant (BOP) process equipment is designed and sized with Aspen®, and cost estimated using equipment vendor quotes. Factory and on-site assembly and installation costs for SOEC stack and BOP equipment integration into modular SOE process units are calculated using a simplified DFMA® method. Total stack costs on a stack input power (SIP) basis reduce to <$100/kW e DC SIP for >500 MW e DC SIP /year production rates with electrode cermet, interconnects, and high-temperature heat treatments dominating the total cost. Integration of stacks with larger BOP equipment operating at higher pressures offers ~36% cost reduction in total facility capital cost due to an economies of physical scale effect since BOP equipment comprises >50% of facility costs. Optimized H 2 prices decrease from ~$\$$4/kgH 2 to ~$\$$2/kgH 2 for 1 GWe DCSIP facilities using $\$$0.025/kWh electricity price. All costs are reported in 2021 US dollars.

08 HYDROGEN↗