Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

An investigation of the modulation of capillary and short gravity waves in the open ocean

A preliminary investigation of the modulation of capillary and gravity waves by long ocean waves is described. A pressure transducer is used to obtain water surface displacements, and a high-response laser-optical system is used to detect short-wave slopes. Analytical techniques are developed to account for the orbital motion of long waves. The local mean squared wave slope is found to be maximum leeward of the long-wave crests. For the long waves studied here and for short waves from 1 cm to 1 m, the longer a short-wave component is, the more leeward its maximum tends to occur. Also, the shortest waves tend to modulate least. The modulation of short waves is found to be strong enough to be an important component of the synthetic aperture radar image formation mechanism for long ocean waves.

Evans, D. D.↗

The effects of exercise on blood flow with reference to the human cardiovascular system: a finite element study

This paper reports on a theoretical investigation into the effects of vasomotion on blood through the human cardiovascular system. The finite element method has been used to analyse the model. Vasoconstriction and vasodilation may be effected either through the action of the central nervous system or autoregulation. One of the conditions responsible for vasomotion is exercise. The proposed model has been solved and quantitative results of flows and pressures due to changing the conductances of specific networks of arterioles, capillaries and venules comprising the arms, legs, stomach and their combinations have been obtained.

NASA Discipline Cardiopulmonary↗

Measurement of net whole-body transcapillary fluid transport and effective vascular compliance in humans

BACKGROUND: Net whole-body transcapillary fluid transport (TFT) between the circulation and the interstitial (extravascular) space may be calculated as: IV - deltaPV - UV - IL, where IV=infused or ingested volume (when applicable), deltaPV = change in plasma volume, UV=urine volume, and IL=insensible loss. RESULTS: Infusion of 30 mL/kg isotonic saline over 25 minutes increased supine TFT from a basal capillary reabsorption of -106+/-24 mL/h (mean+/-SE) to a net filtration of 1,229+/-124 mL/h. One hour after infusion, reabsorption of -236+/-102 mL/h was seen, and control reabsorption levels returned by 3 hours. Four hours of 30 mm Hg lower body negative pressure (LBNP) elicited no net TFT, probably because of upper body reabsorptive compensation for lower body capillary filtration. When ingestion of 1 L of isotonic saline accompanied LBNP, filtration of 145+/-10 mL/h occurred. Reabsorption of extravascular fluid into the circulation always followed LBNP. CONCLUSION: Application of this technique could aid understanding of physiologic conditions, experimental interventions, disease states, and therapies that cause or are influenced by fluid shifts between intravascular and interstitial compartments.

NASA Center JSC↗

Extraction and isotopic analysis of medium molecular weight hydrocarbons from Murchison using supercritical carbon dioxide

The large variety of organic compounds present in carbonaceous chondrites poses particular problems in their analysis not the least of which is terrestrial contamination. Conventional analytical approaches employ simple chromatographic techniques to fractionate the extractable compounds into broad classes of similar chemical structure. However, the use of organic solvents and their subsequent removal by evaporation results in the depletion or loss of semi-volatile compounds as well as requiring considerable preparative work to assure solvent purity. Supercritical fluids have been shown to provide a powerful alternative to conventional liquid organic solvents used for analytical extractions. A sample of Murchison from the Field Museum was analyzed. Two interior fragments were used; the first (2.85 g) was crushed in an agate pestel and mortar to a grain size of ca. 50-100 micron, the second (1.80 g) was broken into chips 3-8 mm in size. Each sample was loaded into a stainless steel bomb and placed in the extraction chamber of an Isco supercritical fluid extractor maintained at 35 C. High purity (99.9995 percent) carbon dioxide was used and was pressurized using an Isco syringe pump. The samples were extracted dynamically by flowing CO2 under pressure through the bomb and venting via a 50 micron fused filica capillary into 5 mls of hexane used as a collection solvent. The hexane was maintained at a temperature of 0.5 C. A series of extractions were done on each sample using CO2 of increasing density. The principal components extracted in each fraction are summarized.

Gilmour, Iain↗

Generation of capillary instabilities by external disturbances in a liquid jet

The receptivity problem in a circular liquid jet is considered. A time harmonic axial pressure gradient is imposed on the steady, parallel flow of a jet of liquid emerging from a circular duct. Using a technique developed in plasma physics a casual solution to the forced problem is obtained over certain ranges of Weber number for a number of mean velocity profiles. This solution contains a term which grows exponentially in the downstream direction and can be identified with a capillary instability wave. Hence, it is found that the externally imposed disturbances can indeed trigger instability waves in a liquid jet. The amplitude of the instability wave generated relative to the amplitude of the forcing is computed numerically for a number of cases.

Leib, S. J.↗

Transient electro-osmosis in capillary tubes.

Transient electro-osmosis of water in capillary tubes for pumping and generation modes, analyzing response to step change in pressure or voltage change under external loading

Hanna, W. T.↗

Study of outgassing and decomposition of space shuttle heat protection tiles, fillers and adhesive

The purpose of this project was to determine the chemicals desorbing from the space shuttle heat protection tiles. The original protocol for this project involved direct insertion probe mass spectrometry (DIPMS) analysis of the outgassing products from the tiles. However, this method proved unsatisfactory due to the large number of compounds desorbing from the tiles. A purge and trap technique was then employed to collect and separate the chemicals desorbing from the tiles. The maximum temperature in this analysis was 180 C which is the gas chromatograph fused silica capillary column's temperature limit. The desorption was also carried out at atmospheric pressure with helium as the purge gas. A description of the modified protocol is given. All compounds are tentatively identified.

Proctor, B. L.↗

Preliminary investigation of a low power pulsed arcjet thruster

A type of pulsed arcjet is examined which operates with gaseous helium propellant at powers from 100 to 1500 W and pulse rats from 360 to 6000 pulses per second. During the pulse, peak power is 50 to 250 kW generating chamber pressures of 10 to 50 atmospheres. The high operating pressure substantially reduces ionization in the 2.5 mm diameter x 12.5 mm long capillary and lowers frozen flow losses in the nozzle. The thruster thermal efficiency, measured calorimetrically, is 43 percent at 440 W and 8 mg/sec helium mass flow rate. Thruster performance trends are predicted by a time-dependent lumped-parameter model which includes heat exchange between the propellant and the wall. The model substantially underpredicts the experimental thermal efficiency values. Alternative thruster configurations yielding significant improvements in thrust efficiency and specific impulse are discussed.

Taylor, Russell D.↗

Investigation of VEGGIE Root Mat

VEGGIE is a plant growth facility that utilizes the phenomenon of capillary action as its primary watering system. A cloth made of Meta Aramid fiber, known as Nomex is used to wick water up from a reservoir to the bottom of the plants roots. This root mat system is intended to be low maintenance with no moving parts and requires minimal crew interface time. Unfortunately, the water wicking rates are inconsistent throughout the plant life cycle, thus causing plants to die. Over-wicking of water occurs toward the beginning of the cycle, while under-wicking occurs toward the middle. This inconsistency of wicking has become a major issue, drastically inhibiting plant growth. The primary objective is to determine the root cause of the inconsistent wicking through experimental testing. Suspect causes for the capillary water column to break include: a vacuum effect due to a negative pressure gradient in the water reservoir, contamination of material due to minerals in water and back wash from plant fertilizer, induced air bubbles while using syringe refill method, and material limitations of Nomex's ability to absorb and retain water. Experimental testing will be conducted to systematically determine the cause of under and over-wicking. Pressure gages will be used to determine pressure drop during the course of the plant life cycle and during the water refill process. A debubbler device will be connected to a root mat in order to equalize pressure inside the reservoir. Moisture and evaporation tests will simultaneously be implemented to observe moisture content and wicking rates over the course of a plant cycle. Water retention tests will be performed using strips of Nomex to determine materials wicking rates, porosity, and absorptivity. Through these experimental tests, we will have a better understanding of material properties of Nomex, as well as determine the root cause of water column breakage. With consistent test results, a forward plan can be achieved to resolve the issue and give valuable insight for the next generation of VEGGIE.

Subbiah, Arun M.↗

High-Power Liquid-Metal Heat-Transfer Loop

Proposed closed-loop system for transfer of thermal power operates at relatively high differential pressure between vapor and liquid phases of liquid-metal working fluid. Resembles "capillary-pumped" liquid-metal heat-transfer loop except electric field across permselective barrier of beta alumina keeps liquid and vapor separate at heat-input end. Increases output thermal power, contains no moving parts, highly reliable and well suited to long-term unattended operation.

Bhandari, Pradeep↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Stability of Detached Solidification

Bridgman crystal growth can be conducted in the so-called "detached" solidification regime, where the growing crystal is detached from the crucible wall. A small gap between the growing crystal and the crucible wall, of the order of 100 micrometers or less, can be maintained during the process. A meniscus is formed at the bottom of the melt between the crystal and crucible wall. Under proper conditions, growth can proceed without collapsing the meniscus. The meniscus shape plays a key role in stabilizing the process. Thermal and other process parameters can also affect the geometrical steady-state stability conditions of solidification. The dynamic stability theory of the shaped crystal growth process has been developed by Tatarchenko. It consists of finding a simplified autonomous set of differential equations for the radius, height, and possibly other process parameters. The problem then reduces to analyzing a system of first order linear differential equations for stability. Here we apply a modified version of this theory for a particular case of detached solidification. Approximate analytical formulas as well as accurate numerical values for the capillary stability coefficients are presented. They display an unexpected singularity as a function of pressure differential. A novel approach to study the thermal field effects on the crystal shape stability has been proposed. In essence, it rectifies the unphysical assumption of the model that utilizes a perturbation of the crystal radius along the axis as being instantaneous. It consists of introducing time delay effects into the mathematical description and leads, in general, to stability over a broader parameter range. We believe that this novel treatment can be advantageously implemented in stability analyses of other crystal growth techniques such as Czochralski and float zone methods.

Mazuruk, K.↗

Packed Bed Reactor Experiment (PBRE)-2: Pressure Drop Measurements in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this paper, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and compare with semi-empirical model pressure drop predictions. This work is supported by the National Aeronautics and Space Administration (NASA) under grant no. 80NSSC20K0830

Suratman Number↗

Pressure Gradient and Gas Hold-Up in Two-Phase Flows through Porous Media in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this presentation, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and gas hold-up and compare with semi-empirical model pressure drop predictions.

Brian Motil↗

Liquid Oxygen Liquid Acquisition Device Bubble Point Tests with High Pressure LOX at Elevated Temperatures

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122K) as part of NASA s continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

Measurements of Thermal Conductivity of Superfluid Helium Near its Transition Temperature T(sub lambda) in a 2D Confinement

We report our recent experiments on thermal conductivity measurements of superfluid He-4 near its phase transition in a two-dimensional (2D) confinement under saturated vapor pressure. A 2D confinement is created by 2-mm- and 1-mm-thick glass capillary plates, consisting of densely populated parallel microchannels with cross-sections of 5 x 50 and 1 x 10 microns, correspondingly. A heat current (2 < Q < 400 nW/sq cm) was applied along the channels long direction. High-resolution measurements were provided by DC SQUID-based high-resolution paramagnetic salt thermometers (HRTs) with a nanokelvin resolution. We might find that thermal conductivity of confined helium is finite at the bulk superfluid transition temperature. Our 2D results will be compared with those in a bulk and 1D confinement.

Jerebets, Sergei↗

Performance of the Linear Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer (MOMA) Investigation on the 2018 Exomars Rover

The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from degradation derived from cosmic radiation and/or oxidative chemical reactions. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. The MOMA investigation is led by the Max Planck Institute for Solar System Research (MPS) with the mass spectrometer subsystem provided by NASA GSFC. MOMA's linear ion trap mass spectrometer (ITMS) is designed to analyze molecular composition of: (i) gas evolved from pyrolyzed powder samples and separated in a gas chromatograph; and, (ii) ions directly desorbed from crushed solid samples at Mars ambient pressure, as enabled by a pulsed UV laser system, fast-actuating aperture valve and capillary ion inlet. Breadboard ITMS and associated electronics have been advanced to high end-to-end fidelity in preparation for flight hardware delivery to Germany in 2015.

linear ion trap mass spectrometer↗