Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacitive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering of Self‐Aggregation‐Resistant MnO 2 Heterostructure with A Built‐in Field for Enhanced High‐Mass‐Loading Energy Storage

Abstract Although MnO 2 has been intensively investigated for energy storage, further applications are limited by van der Waals force‐triggered self‐aggregation that always leads to poorly exposed active sites and compromised reaction dynamics, especially under high‐mass‐loading conditions. Herein, by synergistically coupling interfacial modulation with the Kirkendall effect, this work achieves in situ topological structure reorganization of MnOOH toward the high‐aspect‐ratio MnO 2 heterostructure (Heter‐MnO 2 ) with fully exposed active sites, which is ready to assemble into self‐supporting high‐mass‐loading film (30 mg cm −2 ) with restrained self‐aggregation. Theoretical calculation and dynamics analysis results demonstrate the generation of the built‐in field within the heterostructure, thus enhancing the electronic‐transfer and ionic‐adsorption/transport rates. As such, the 30 mg cm −2 Heter‐MnO 2 electrode achieves a superior areal capacitance of 4762 mF cm −2 at 1 mA cm −2 and a sound rate performance (79% at 100 mA cm −2 ) comparable to those of low‐mass‐loading/thin‐film electrodes. As a proof of concept, the fabricated planar interdigital quasi‐solid‐state symmetric micro‐supercapacitor (MSC) based on the Heter‐MnO 2 electrode can deliver a remarkable areal capacitance of 181 mF cm −2 and a considerable volumetric energy density of 10.3 mWh cm −3 . This methodology highlights the promise of surface/interface chemistry modulation for the configuration of easy‐to‐integrate hierarchical nanostructures to better meet practical energy applications.

Chemistry↗

Dynamic Capacitive Wireless Power Transfer System for Electric Vehicles (CRADA Final Report)

Road transportation accounts for 23% of our nation's total energy consumption, 59% of our petroleum consumption and 22% of our total emissions. Electric vehicles (EVs) have much higher well-to-wheel efficiency compared to gasoline vehicles and can reduce our dependence on oil, minimize emissions, improve local air quality and provide a platform for technological innovation and economic growth. While major progress has been made in the development of electric vehicles, their penetration remains under 1 The main hurdles in their widespread adoption are high cost, limited range and long charging times, due to limitations in battery technology. An approach to overcome these hurdles is to substantially reduce the on-board energy storage and instead deliver power wirelessly to the vehicle while it is in motion dynamic wireless power transfer (WPT). For EV charging applications, researchers have traditionally focused on inductive WPT. An issue with inductive WPT systems is that for magnetic flux guidance and shielding, they require ferrite cores, making them expensive, bulky and difficult to embed in the roadway. Under an ARPA-E IDEAS grant, the CU Boulder team has recently developed an alternative approach to WPT based on capacitive coupling that is much smaller, lighter, less expensive, and easier to embed in the roadway than inductive WPT; and have demonstrated a 1.2-kW 6.78-MHz version of this capacitive WPT system on a stationary platform. Under this seed grant program, preliminary work will be carried out on a dynamic capacitive WPT system to prepare a strong proposal for the ARPA-E OPEN 2018 FOA.

33 ADVANCED PROPULSION SYSTEMS↗

Detection of Chemical Precursors of Explosives

Certain selected chemicals associated with terrorist activities are too unstable to be prepared in final form. These chemicals are often prepared as precursor components, to be combined at a time immediately preceding the detonation. One example is a liquid explosive, which usually requires an oxidizer, an energy source, and a chemical or physical mechanism to combine the other components. Detection of the oxidizer (e.g. H2O2) or the energy source (e.g., nitromethane) is often possible, but must be performed in a short time interval (e.g., 5 15 seconds) and in an environment with a very small concentration (e.g.,1 100 ppm), because the target chemical(s) is carried in a sealed container. These needs are met by this invention, which provides a system and associated method for detecting one or more chemical precursors (components) of a multi-component explosive compound. Different carbon nanotubes (CNTs) are loaded (by doping, impregnation, coating, or other functionalization process) for detecting of different chemical substances that are the chemical precursors, respectively, if these precursors are present in a gas to which the CNTs are exposed. After exposure to the gas, a measured electrical parameter (e.g. voltage or current that correlate to impedance, conductivity, capacitance, inductance, etc.) changes with time and concentration in a predictable manner if a selected chemical precursor is present, and will approach an asymptotic value promptly after exposure to the precursor. The measured voltage or current are compared with one or more sequences of their reference values for one or more known target precursor molecules, and a most probable concentration value is estimated for each one, two, or more target molecules. An error value is computed, based on differences of voltage or current for the measured and reference values, using the most probable concentration values. Where the error value is less than a threshold, the system concludes that the target molecule is likely. Presence of one, two, or more target molecules in the gas can be sensed from a single set of measurements.

Li, Jing↗

A linearly controlled direct-current power source for high-current inductive loads in a magnetic suspension wind tunnel

The NASA Langley 6 inch magnetic suspension and balance system (MSBS) requires an independently controlled bidirectional DC power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance coupled thyratron controlled rectifiers as well as AC to DC motor generator converters, is obsolete, inefficient, and unreliable. A replacement six phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full load efficiency is 80 percent compared to 25 percent for the resistance coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20 kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

Tripp, John S.↗

A solid-state controllable power supply for a magnetic suspension wind tunnel

The NASA Langley 6-inch Magnetic Suspension and Balance System (6-in. MSBS) requires an independently controlled bidirectional dc power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance-coupled thyratron-controlled rectifiers as well as ac to dc motor-generator converters, is obsolete, inefficient, and unreliable. A replacement six-phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full-load efficiency is 80 percent compared with 25 percent for the resistance-coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20-kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

Daniels, Taumi S.↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

An extensometer for global measurement of bone strain suitable for use in vivo in humans

An axial extensometer able to measure global bone strain magnitudes and rates encountered during physiological activity, and suitable for use in vivo in human subjects, is described. The extensometer uses paired capacitive sensors mounted to intraosseus pins and allows measurement of strain due to bending in the plane of the extensometer as well as uniaxial compression or tension. Data are presented for validation of the device against a surface-mounted strain gage in an acrylic specimen under dynamic four-point bending, with square wave and sinusoidal loading inputs up to 1500 mu epsilon and 20 Hz, representative of physiological strain magnitudes and frequencies. Pearson's correlation coefficient (r) between extensometer and strain gage ranged from 0.960 to 0.999. Mean differences between extensometer and strain gage ranged up to 15.3 mu epsilon. Errors in the extensometer output were directly proportional to the degree of bending that occurs in the specimen, however, these errors were predictable and less than 1 mu epsilon for the loading regime studied. The device is capable of tracking strain rates in excess of 90,000 mu epsilon/s.

Non-NASA Center↗

Capacitive Sensor With Driven Shields And Bridge Circuit

Like other capaciflectors described in prior articles in NASA Tech Briefs, this one includes sensing electrode driven by alternating voltage, giving rise to electric field in vicinity of electrode; object entering electric field detected by its effect on capacitance between sensing electrode and electrical ground. Also includes shielding electrode (in this case, driven shield 1), excited via voltage follower at same voltage as that applied to sensing electrode to concentrate more of electric field outward from sensing electrode, increasing sensitivity and range of sensor. Because shielding electrode driven via voltage follower, it does not present significant electrical load to source of alternating voltage.

Vranish, John M.↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

RF Reference Switch for Spaceflight Radiometer Calibration

The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve rejection. The use of open-circuit stubs instead of a via to provide an improved RF short is unique to this design. The stubs are easily tunable to provide high rejection at specific frequencies while maintaining very low insertion loss in-band.

Knuble, Joseph↗

Upcycling Linear Low-Density Polyethylene Waste into Graphene for High Mass Loading Supercapacitors

Upcycling plastic into advanced carbons, such as graphene and porous carbon, offers attractive options to manage waste streams by converting the plastic into carbon electrode materials for energy storage devices. Linear low density polyethylene (LLDPE) is firstly bulk-oxidized with a facile and scalable method and then carbonized and catalyticlly graphenized into porous graphene materials. The LLDPE derived graphene (LLDPE-G) has a BET specific surface area up to 1800 m2/g and Raman ID/IG ratio of 0.85. When used as electrode material for symmetric supercapacitor, LLDPE-G possesses outstanding specific capacitance and excellent areal capacitance. Moreover, LLDPE-G exhibits exceptional cycling stability with capacitance retention of 95.8% after 100,000 cycles. Last but not least, KCl is recycled and reused over 3 cycles with material quality and electrocapacitive performance of LLDPE-G retained and verified after each cycle.

Gao, Yuan↗

Resistively loaded coplanar waveguide for microwave measurements of induced carriers

We describe the use of a coplanar waveguide (CPW) whose slots are filled with a resistive film, a resistively loaded CPW (RLCPW), to measure two-dimensional electron systems (2DESs). The RLCPW applied to the sample hosting the 2DES provides a uniform metallic surface serving as a gate to control the areal charge density of the 2DES. As a demonstration of this technique, we present measurements on a Si metal–oxide–semiconductor field-effect transistor and a model that successfully converts microwave transmission coefficients into conductivity of a nearby 2DES capacitively coupled to the RLCPW. We also describe the process of fabricating the highly resistive metal film required for fabrication of the RLCPW.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Fireset Acceptance Using Established Evaluation Measurements

As new insight is gained into the relationship between firesets and detonators, tighter control of the circuit parameters is desired to maintain consistent and optimum system performance. An analysis of the established acceptance method reveals that it has insufficient precision to guarantee a uniform population of units. While the production has been historically very uniform, the uniformity has been primarily due to the quality and consistency of the manufacturing process rather than to the stringency of the acceptance criteria. The established method of evaluating and accepting firesets for the stockpile has been to discharge the units into a representative load and to record the output current waveform. Three characteristics of the output waveform (Peak Current, Rise Time, and Pulse Width) are then analyzed and an acceptance window is applied directly to these measurements. The purpose of this paper is to introduce a new approach that incorporates these same established measurements. However, instead of applying acceptance criteria to the three measurements directly, rather these measurements are used to evaluate the circuit values of capacitance, inductance and resistance to provide a more stringent and uniform acceptance criteria.

42 ENGINEERING↗

Power matching to pulsed inductively coupled plasmas

Matching of power delivery to nonlinear loads in plasma processing is a continuing challenge. Plasma reactors used in microelectronics fabrication are increasingly multi-frequency and/or pulsed, producing a non-linear and, in many cases, non-steady state electrical termination that can complicate efficient power coupling to the plasma. This is particularly the case for pulsed inductively coupled plasmas where the impedance of the plasma can significantly change during the start-up-transient and undergo an E–H (capacitive-to-inductive) transition. In this paper, we discuss the results from a computational investigation of the dynamics of power matching to pulsed inductively coupled plasmas (Ar/Cl 2 mixtures of tens of mTorr pressure) using fixed component impedance matching networks and their consequences on plasma properties. In this investigation, we used set-point matching where the components of the matching network provide a best-case impedance match (relative to the characteristic impedance of the power supply) at a chosen time during the pulsed cycle. Matching impedance early during the pulse enables power to feed the E-mode, thereby emphasizing capacitive coupling and large excursions in the plasma potential. This early power coupling enables a more rapid ramp-up in plasma density while being mismatched during the H-mode later in the pulse. The early match also produces more energetic ion bombardment of surfaces. Matching late in the pulse diminishes power dissipated in the E-mode at the cost of also reducing the rate of increase in plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Passive components for high temperature operation

The development of resistors, capacitors, and interconnect metalizations utilizing a low pressure chemical vapor deposition (LPCVD) process is described. The LPCVD process allows the passive components to be fabricated at temperatures higher than their highest operating temperatures. The deposition of thin films by LPCVD is accomplished by reacting one or more gases on the surface of a heated substrate. The substrates to be coated are placed on a graphite susceptor and then loaded into the center of a quartz reaction tube. The RF power is applied to the coil on the outside of the reaction tube which in turn is coupled into the graphite susceptor causing it to heat. Pressures of several torr or less are typical, with carrier flow rates of 0.1 to 2.0 liters/min. Nitrogen, hydrogen, and helium are typical carrier gases. These are controlled with mass flow controllers and the pressure is continuously monitored with a capacitive manometer. Materials selection and device testing are also discussed.

Raymond, L. S.↗

High-Energy-Density Electrolytic Capacitors

Reductions in weight and volume make new application possible. Supercapacitors and improved ultracapacitors advanced electrolytic capacitors developed for use as electric-load-leveling devices in such applications as electric vehicle propulsion systems, portable power tools, and low-voltage pulsed power supplies. One primary advantage: offer power densities much higher than storage batteries. Capacitors used in pulse mode, with short charge and discharge times. Derived from commercially available ultracapacitors. Made of lightweight materials; incorporate electrode/electrolyte material systems capable of operation at voltages higher than previous electrode/electrolyte systems. By use of innovative designs and manufacturing processes, made in wide range of rated capacitances and in rated operating potentials ranging from few to several hundred volts.

Yen, Shiao-Ping S.↗

Analysis and Design of Crew Sleep Station for ISS

This paper details the analysis and design of the Temporary Sleep Station (TeSS) environmental control system for International Space Station (ISS). The TeSS will provide crewmembers with a private and personal space, to accommodate sleeping, donning and doffing of clothing, personal communication and performance of recreational activities. The need for privacy to accommodate these activities requires adequate ventilation inside the TeSS. This study considers whether temperature, carbon dioxide, and humidity within the TeSS remain within crew comfort and safety levels for various expected operating scenarios. Evaluation of these scenarios required the use and integration of various simulation codes. An approach was adapted for this study, whereby results from a particular code were integrated with other codes when necessary. Computational Fluid Dynamics (CFD) methods were used to evaluate the flow field inside the TeSS, from which local gradients for temperature, velocity, and species concentration such as CO (sub 2) could be determined. A model of the TeSS, containing a human, as well as equipment such as a laptop computer, was developed in FLUENT, a finite-volume code. Other factors, such as detailed analysis of the heat transfer through the structure, radiation, and air circulation from the TeSS to the US Laboratory Aisle, where the TeSS is housed, were considered in the model. A complementary model was developed in G189A, a code which has been used by NASA/JSC for environmental control systems analyses since the Apollo program. Boundary conditions were exchanged between the FLUENT and G189A TeSS models. G189A provides human respiration rates to the FLUENT model, while the FLUENT model provides local convective heat transfer coefficients to G189A model. An additional benefit from using an approach with both a systems simulation and CFD model, is the capability to verify the results of each model by comparison to the results of the other model. The G189A and FLUENT models were used to evaluate various ventilation designs for the TeSS over a range of operating conditions with varying crew metabolic load, equipment operating modes, ventilation flow rates, and with the TeSS doors open and closed. Results from the study were instrumental in the optimization of a design for the TeSS ventilation hardware. A special case was considered where failure of the TeSS ventilation system occurred. In this case, a study was conducted in order to determine the time required for the CO (sub 2) concentration inside the TeSS to increase to ISS limit values under transient conditions. A lumped-capacitance code, SINDA-FLUINT was used in this case to provide accurate predictions of the human reaction to the TeSS cabin conditions including core and skin temperatures and body heat storage. A simple two-dimensional CFD model of a crewmember inside the TeSS was developed in FLUENT in order to determine the volume envelope of the respired air from the human, which maintained a minimum velocity profile. This volume was then used in the SINDA-FLUINT model to facilitate the calculations of CO (sub 2) concentrations, dry bulb temperatures and humidity levels inside the TeSS.

Keener, John F.↗