Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

On-Ground Calibration and Optical Alignment for the Orion Optical Navigation Camera

The Orion Multi-Purpose Crew Vehicle on-board Navigation System will utilize the Optical Navigation measurements of the Moon and Earth during cis-lunar operations. Misalignment or an un-calibrated optical navigation camera may cause large measurement residuals in any on-board attitude determination and navigation system. Therefore, a novel estimation technique to calibrate the internal camera parameters, and a high accuracy optical alignment procedure to estimate the external camera alignment are introduced in this paper. The intrinsic camera parameters such as the focal length, the principle point offsets, and the camera lens distortion parameters will be estimated and evaluated using images of star fields. This calibration estimation technique can be used either on-ground or in flight. The proposed technique in this paper is using the discrepancy between imaged star vectors attained from the OpNav camera, and the matched star vectors from the star catalog to determine the changes in internal camera parameters. This gave rise to the two basic types of calibration the attitude dependent and attitude independent methods. The former utilizes the errors in imaged and cataloged vectors themselves, and the latter using the discrepancy in angles between pairs of vectors from the camera and catalog. The alignment procedure is carried out using Theodolite autocollimator measurements taken off alignment cubes mounted on the Orion frame and also the measurements from the OpNav focal plane. It is assumed that the alignment cubes and OpNav camera are rigidly mounted to the frame so that flexing effects do not significantly alter the orientation of the cubes relative to the OpNav camera.

Samaan, Malak↗

Photometric calibration of the International Ultraviolet Explorer (IUE) at low resolution - The LWP camera

We present and discuss the low resolution absolute calibration for the LWP camera of the International Ultraviolet Explorer (IUE). The calibration, implemented in routine processing of LWP low resolution images on December 22, 1987 at both GSFC and VILSPA IUE ground stations, is based on the last set of Intensity Transfer Function (ITF 2) obtained in September 1984 and on a substantially larger amount of IUE observations of standard stars than used for the preliminary calibration by Cassatella & Harris (1983) based on the earlier ITF (ITF 1). The new ITF and the associated calibration provide upgraded performances in flux accuracy, signal-to-noise ratio and linearity with respect to the earlier LWP ITF1 which was implemented in processing LWP data obtained in the period from October 16, 1983 until December 21, 1987.

Cassatella, A.↗

Method and apparatus for calibrating a display using an array of cameras

The present invention overcomes many of the disadvantages of the prior art by providing a display that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, the present invention provides one or more cameras to capture an image that is projected on a display screen. In one embodiment, the one or more cameras are placed on the same side of the screen as the projectors. In another embodiment, an array of cameras is provided on either or both sides of the screen for capturing a number of adjacent and/or overlapping capture images of the screen. In either of these embodiments, the resulting capture images are processed to identify any non-desirable characteristics including any visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and/or other visible artifacts.

Johnson, Michael J.↗

Virtual Reality Calibration and Preview/Predictive Displays for Telerobotics

A virtual reality (VR) calibration technique of matching a virtual environment of simulated 3-D graphic models with actual camera views of the remote site task environment has been developed. This VR calibration enables high-fidelity preview/predictive displays with calibrated graphics overlay on live video. Reliable and accurate calibration is achieved by operator-interactive camera calibration and object localization procedures based on new linear/nonlinear least-squares algorithms that can handle multiple-camera views.

Virtual↗

A Precise Calibration Technique for Measuring High Gas Temperatures

A technique was developed for direct measurement of gas temperatures in the range of 2050 K - 2700 K with improved accuracy and reproducibility. The technique utilized the low-emittance of certain fibrous Materials, and the uncertainty of the technique was limited by the uncertainty in the melting points of the materials, i.e., +/- 15 K. The materials were pure, thin, metal-oxide fibers whose diameters varied from 60 mm to 400 mm in the experiments. The sharp increase in the emittance of the fibers upon melting was utilized as indication of reaching a known gas temperature. The accuracy of the technique was confirmed by both calculated low emittance values of transparent fibers, of order 0.01, up to a few degrees below their melting point and by the fiber-diameter independence of the results. This melting-point temperature was approached by increments not larger than 4 K, which was accomplished by controlled increases of reactant flow rates in hydrogen-air and/or hydrogen- oxygen flames. As examples of the applications of the technique, the gas-temperature measurements were used (a) for assessing the uncertainty in infering gas temperatures from thermocouple measurements, and (b) for calibrating an IR camera to measure gas temperatures. The technique offers an excellent calibration reference for other gas-temperature measurement methods to improve their accuracy and reliably extending their temperature range of applicability.

Gokoglu, Suleyman A.↗

A Precise Calibration Technique for Measuring High Gas Temperatures

A technique was developed for direct measurement of gas temperatures in the range of 2050 K 2700 K with improved accuracy and reproducibility. The technique utilized the low-emittance of certain fibrous materials, and the uncertainty of the technique was United by the uncertainty in the melting points of the materials, i.e., +/-15 K. The materials were pure, thin, metal-oxide fibers whose diameters varied from 60 microns to 400 microns in the experiments. The sharp increase in the emittance of the fibers upon melting was utilized as indication of reaching a known gas temperature. The accuracy of the technique was confirmed by both calculated low emittance values of transparent fibers, of order 0.01, up to a few degrees below their melting point and by the fiber-diameter independence of the results. This melting-point temperature was approached by increments not larger than 4 K, which was accomplished by controlled increases of reactant flow rates in hydrogen-air and/or hydrogen-oxygen flames. As examples of the applications of the technique, the gas-temperature measurements were used: (a) for assessing the uncertainty in inferring gas temperatures from thermocouple measurements, and (b) for calibrating an IR camera to measure gas temperatures. The technique offers an excellent calibration reference for other gas-temperature measurement methods to improve their accuracy and reliably extending their temperature range of applicability.

Gokoglu, Suleyman A.↗

Melt Pool Imaging using a Configurable Architecture Additive Testbed System

This paper describes the inline (coaxial to laser) near infrared (NIR) camera sensor on the Configurable Architecture Additive Testbed (CAAT). The CAAT is an instrument that provides the capability to investigate laser based additive manufacturing (AM) processes and is configured for the metal powder bed fusion process. A low cost NIR camera is radiometrically calibrated to obtain coaxial, inline, imagery of laser generated melt pools. The camera capabilities, system optical path, and the uncertainty in the temperature measurement from NIR surface area scans on a bare titanium alloy plate are presented and discussed. The surface radiance measurements are compared to optical microscopy images of the melt pool width and depth. A metallic additive manufacturing process thermal model is developed in order to predict thermal distributions during laser scanning. The predicted thermal distributions by the model for different configurations are compared to the coaxial NIR measurements and discussed.

Additive manufacturing↗

The Clementine instrument complement

The recent successes of the Galileo solid-state imaging (SSI) experiment at the Moon and Gaspra show the utility of multispectral imaging of planetary objects. 'Clementine' is the planetary community's 'code name' for the SDIO (Space Defense Initiative Organization), mission to the Moon and the asteroid Geographos. This mission is designed as a long term stressing test on sensors and space systems developed for SDIO. In the course of this test Clementine will obtain science data using a varied and powerful array of remote sensing instruments which were developed by or for Lawrence Livermore National Laboratory in Livermore, California. Clementine carries five cameras, one for navigation and four for science experiments. In addition, a laser ranger is included which will serve as a laser altimeter. The Clementine cameras cover a wider range of spatial resolutions and wavelength range than did Galileo and are almost ideally suited to mapping of mafic rock types as are present on the Moon and expected at Geographos. Calibration of the cameras will occur at the sensor calibration laboratory at LLNL. In flight calibrations, using standard stars and other standards should improve the stated accuracies. Signal-to-noise ratios (SNRs) include the following noise sources: shot noise, calibration error, digitization noise, readout noise, and frame transfer noise (where applicable). The achieved SNRs are a balance between detector saturation and acceptable image smear. The 'worst' case uses the longest possible integration times.

Lucey, Paul G.↗

Calibration and performance of the Viking lander cameras

The paper discusses Viking lander cameras which have an angular resolution of 0.12 deg, and (for broadband imaging) a resolution of 0.04 deg, used for the acquisition of data in six spectral bands for color and near-infrared imaging. Attention is given to photogrammetric calibration techniques used in the determination of spatial and spectral brightness variations from image data. The effects of sampling on the achievable photogrammetric precision are described along with techniques for preflight spectral calibrations and the corrections required for degradation in the infrared response of the detectors. The effects of the known internal reflections on the qualitative images (such as the appearance of artifact clouds) are presented, noting their effects on skyline radiometry. The qualitative and quantitative effects of the signal quantization are briefly reviewed.

Patterson, W. R., III↗

Automatically calibrating admittances in KATE's autonomous launch operations model

This report documents a 1000-line Symbolics LISP program that automatically calibrates all 15 fluid admittances in KATE's Autonomous Launch Operations (ALO) model. (KATE is Kennedy Space Center's Knowledge-based Autonomous Test Engineer, a diagnosis and repair expert system created for use on the Space Shuttle's various fluid flow systems.) As a new KATE application, the calibrator described here breaks new ground for KSC's Artificial Intelligence Lab by allowing KATE to both control and measure the hardware she supervises. By automating a formerly manual process, the calibrator: (1) saves the ALO model builder untold amounts of labor; (2) enables quick repairs after workmen accidently adjust ALO's hand valves; and (3) frees the modeler to pursue new KATE applications that previously were too complicated. Also reported are suggestions for enhancing the program: (1) to calibrate ALO's TV cameras, pumps, and sensor tolerances; and (2) to calibrate devices in other KATE models, such as the shuttle's LOX and Environment Control System (ECS).

Morgan, Steve↗

Biomechanics of the Treadmill Locomotion on the International Space Station

Exercise prescriptions completed by International Space Station (ISS) crewmembers are typically based upon evidence obtained during ground-based investigations, with the assumption that the results of long-term training in weightlessness will be similar to that attained in normal gravity. Coupled with this supposition are the assumptions that exercise motions and external loading are also similar between gravitational environments. Normal control of locomotion is dependent upon learning patterns of muscular activation and requires continual monitoring of internal and external sensory input [1]. Internal sensory input includes signals that may be dependent on or independent of gravity. Bernstein hypothesized that movement strategy planning and execution must include the consideration of segmental weights and inertia [2]. Studies of arm movements in microgravity showed that individuals tend to make errors but that compensation strategies result in adaptations, suggesting that control mechanisms must include peripheral information [3-5]. To date, however, there have been no studies examining a gross motor activity such as running in weightlessness other than using microgravity analogs [6-8]. The objective of this evaluation was to collect biomechanical data from crewmembers during treadmill exercise before and during flight. The goal was to determine locomotive biomechanics similarities and differences between normal and weightless environments. The data will be used to optimize future exercise prescriptions. This project addresses the Critical Path Roadmap risks 1 (Accelerated Bone Loss and Fracture Risk) and 11 (Reduced Muscle Mass, Strength, and Endurance). Data were collected from 7 crewmembers before flight and during their ISS missions. Before launch, crewmembers performed a single data collection session at the NASA Johnson Space Center. Three-dimensional motion capture data were collected for 30 s at speeds ranging from 1.5 to 9.5 mph in 0.5 mph increments with a 12-camera system. During flight, each crewmember completed up to 6 data collection sessions spread across their missions, performing their normal exercise prescription for the test day, resulting in varying data collection protocols between sessions. Motion data were collected by a single HD video camera positioned to view the crewmembers' left side, and tape markers were placed on their feet, legs, and neck on specific landmarks. Before data collection, the crewmembers calibrated the video camera. Video data were collected during the entire exercise session at 30 Hz. Kinematic data were used to determine left leg hip, knee, and ankle range of motion and contact time, flight time, and stride time for each stride. 129 trials in weightlessness were analyzed. Mean time-normalized strides were found for each trial, and cross-correlation procedures were used to examine the strength and direction of relationships between segment movement pattern timing in each gravitational condition. Cross-correlation analyses between gravitational conditions revealed highly consistent movement patterns at each joint. Peak correlation coefficients occurred at 0% phase, indicating there were no lags in movement timing. Joint ranges of motion were similar between gravitational conditions, with some slight differences between subjects. Motion patterns in weightlessness were highly consistent at a given speed with those occurring in 1G, indicating that despite differing sensory input, subjects maintain running kinematics. The data suggest that individuals are capable of compensating for loss of limb weight when creating movement strategies. These results have important implications for creating training programs for use in weightlessness as practitioners can have greater confidence in running motions transferring across gravitational environments. Furthermore, these results have implications for use by researchers investigating motor control mechanisms and investigating hypotheses related to movement strategies when using sensory input that is dependent upon gravity.

DeWitt, John↗

Calibration Status and Results for Wide Field Camera 3

Wide Field Camera 3 (WFC3) is a general-purpose imager in development for installation in HST Servicing Mission 4 (SM4). Covering the wavelength range of 200-1700 nm in two observing channels, WFC3 offers powerful new capabilities, particularly in the near-ultraviolet and near-infrared bands. During 2004, the instrument was integrated and underwent a substantial suite of end-to-end characterization and performance tests. In this paper, we present a brief overview of the design and scientific purpose of WFC3, summarize the results of its test program to date, and highlight some recent developments in detector technology that will further enhance the performance of WFC3 s IR channel.

Kimble, Randy A.↗

Comparison of In-situ Near Infrared Melt Pool Imagery to Optical Microscopy Measurements

Additive manufacturing (AM) is a rapidly growing technology. An area of major importance is the integrity and repeatability of AM parts. The goal is to reduce obstacles to certify AM built parts to allow for use in critical aerospace applications. In-situ nondestructive evaluation sensors can be used for build assessment and can potentially play a key role in certifying AM parts. For example, melt pool features are understood to have a strong correlation to microstructural defects and the use of a near infrared (NIR) camera can be used to record the melt pool, cooling areas, and temperature gradients during the build. This work explores the use of a low cost NIR camera to obtain single line track imagery of the Ti-6Al-4V melt pools for various processing parameters. The NIR camera is radiometrically calibrated and configured in-line with the laser source to obtain high resolution imagery of the melt pool shape and dynamics. The challenge to measure melt pool shapes is to identify the transition points between the metal solid to liquid phase. Factors for melt pool measurements such as thermal camera pixel resolution, surface emissivity, and blurring due to the laser beam movement are discussed. Lastly, the melt pool imagery are compared to optical microscopy measurements for validation.

additive manufacturing↗

MISR Calibration Issues in High-Contrast Scenes, and Empirical Corrections

We diagnose the potential causes for the Multi-angle Imaging SpectroRadiometer's (MISR) persistent high aerosol optical depth (AOD) bias at low AOD with the aid of coincident MODerate-resolution Imaging Spectroradiometer (MODIS) imagery from NASA's Terra satellite. Internal reflections within the MISR instrument are responsible for a large portion of the high AOD bias in high-contrast scenes, which are especially common as broken-cloud situations over ocean. Discrepancies between MODIS and MISR nadir-viewing near-infrared (NIR) images are used to optimize nine parameters, along with a background reflectance modulation term (that was modeled separately), to represent the observed features. Independent, surface-based AOD measurements from the AErosol RObotic NETwork (AERONET) and the Marine Aerosol Network (MAN) are compared with MISR Research Algorithm (RA) AOD retrievals for 1118 coincidences to validate the corrections when applied to the nadir and off-nadir cameras. Additionally, the calibration coefficients for the red and NIR channels used for MISR over-water aerosol retrievals were reassessed with the RA to be consistent on a camera-by-camera basis. With these corrections, plus the baseline RA corrections applied (except enhanced cloud screening), the median AOD bias in the mid-visible (green) band decreases from 0.010 to 0.002, the RMSE decreases by approx. 10%, and the slope and correlation of the MISR vs. sun photometer Ångström Exponent improves. For AOD558 nm < 0.10 and with additional cloud screening, the median bias for the RA-retrieved AOD in the green band decreases from 0.011 to 0.003, compared to ~ 0.023 for the Standard Algorithm (SA). RMSE decreases by ~ 20% compared to the baseline (uncorrected) RA and by 17-53% compared to the SA. After all corrections and cloud screening are implemented, for AOD558 nm < 0.10, which includes about half the validation data, 68% absolute AOD errors for the RA have dropped to < 0.02 (approx. 0.018).

MISR↗

Proceedings of the 2004 High Spatial Resolution Commercial Imagery Workshop

Topics covered include: NASA Applied Sciences Program; USGS Land Remote Sensing: Overview; QuickBird System Status and Product Overview; ORBIMAGE Overview; IKONOS 2004 Calibration and Validation Status; OrbView-3 Spatial Characterization; On-Orbit Modulation Transfer Function (MTF) Measurement of QuickBird; Spatial Resolution Characterization for QuickBird Image Products 2003-2004 Season; Image Quality Evaluation of QuickBird Super Resolution and Revisit of IKONOS: Civil and Commercial Application Project (CCAP); On-Orbit System MTF Measurement; QuickBird Post Launch Geopositional Characterization Update; OrbView-3 Geometric Calibration and Geopositional Accuracy; Geopositional Statistical Methods; QuickBird and OrbView-3 Geopositional Accuracy Assessment; Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images; Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps; Stennis Space Center Verification and Validation Capabilities; Joint Agency Commercial Imagery Evaluation (JACIE) Team; Adjacency Effects in High Resolution Imagery; Effect of Pulse Width vs. GSD on MTF Estimation; Camera and Sensor Calibration at the USGS; QuickBird Geometric Verification; Comparison of MODTRAN to Heritage-based Results in Vicarious Calibration at University of Arizona; Using Remotely Sensed Imagery to Determine Impervious Surface in Sioux Falls, South Dakota; Estimating Sub-Pixel Proportions of Sagebrush with a Regression Tree; How Do YOU Use the National Land Cover Dataset?; The National Map Hazards Data Distribution System; Recording a Troubled World; What Does This-Have to Do with This?; When Can a Picture Save a Thousand Homes?; InSAR Studies of Alaska Volcanoes; Earth Observing-1 (EO-1) Data Products; Improving Access to the USGS Aerial Film Collections: High Resolution Scanners; Improving Access to the USGS Aerial Film Collections: Phoenix Digitizing System Product Distribution; System and Product Characterization: Issues Approach; Innovative Approaches to Analysis of Lidar Data for the National Map; Changes in Imperviousness near Military Installations; Geopositional Accuracy Evaluations of QuickBird and OrbView-3: Civil and Commercial Applications Project (CCAP); Geometric Accuracy Assessment: OrbView ORTHO Products; QuickBird Radiometric Calibration Update; OrbView-3 Radiometric Calibration; QuickBird Radiometric Characterization; NASA Radiometric Characterization; Establishing and Verifying the Traceability of Remote-Sensing Measurements to International Standards; QuickBird Applications; Airport Mapping and Perpetual Monitoring Using IKONOS; OrbView-3 Relative Accuracy Results and Impacts on Exploitation and Accuracy Improvement; Using Remotely Sensed Imagery to Determine Impervious Surface in Sioux Falls, South Dakota; Applying High-Resolution Satellite Imagery and Remotely Sensed Data to Local Government Applications: Sioux Falls, South Dakota; Automatic Co-Registration of QuickBird Data for Change Detection Applications; Developing Coastal Surface Roughness Maps Using ASTER and QuickBird Data Sources; Automated, Near-Real Time Cloud and Cloud Shadow Detection in High Resolution VNIR Imagery; Science Applications of High Resolution Imagery at the USGS EROS Data Center; Draft Plan for Characterizing Commercial Data Products in Support of Earth Science Research; Atmospheric Correction Prototype Algorithm for High Spatial Resolution Multispectral Earth Observing Imaging Systems; Determining Regional Arctic Tundra Carbon Exchange: A Bottom-Up Approach; Using IKONOS Imagery to Assess Impervious Surface Area, Riparian Buffers and Stream Health in the Mid-Atlantic Region; Commercial Remote Sensing Space Policy Civil Implementation Update; USGS Commercial Remote Sensing Data Contracts (CRSDC); and Commercial Remote Sensing Space Policy (CRSSP): Civil Near-Term Requirements Collection Update.

Source record↗

Bacterial contamination monitor

Economical, simple, and fast method uses apparatus which detects bacteria by photography. Apparatus contains camera, film assembly, calibrated light bulb, opaque plastic plate with built-in reflecting surface and transparent window section, opaque slide, plate with chemical packages, and cover containing roller attached to handle.

Rich, E.↗