Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

PBX9502 PAGOSA/SURF Calibration for 100 µm Grid Size

There are two methods to calibrate the SURF reactive burn explosives model.The first is to calibrate using Pop plot data. Because there are only two main parameters in SURF, called A and B, there is just enough flexibility in SURF to determine the Pop plot line, i.e., equivalent information to a slope and a single point on the line. However, due to the linearity of the Pop plot being based on logarithmic scales, a slight deviation off the Pop plot (though the fit to the Pop plot might be very good overall) can make considerable difference when comparing with the velocity profile data. The second calibration method thusly focuses strongly on matching entire velocity profile data. This is to say that individual velocity profiles extracted from embedded gages (in the case of PBX 9502, we refer to R. Gustavsen’s experimental data) may fit poorly, while the overall fit to the Pop plot may seem reasonable. In addition, there are other factors that could produce slightly different calibrations for SURF, while leading to an overall acceptable fit to data. One of those may be the physics code used and here we use Pagosa. Another is mesh size dependence. A third one stems from fitting a reactive burn model being done in conjunction with an equation of state (EOS) of the reactants and one for the products – different EOS can result in slightly different parameterizations. Finally, there are several secondary material parameters in SURF, and the overall fit will depend on the entire parameterization. The goal of this report is to clarify some of our previously made statements about SURF calibration, as well as to redo a systematic calibration using 100 µm grid resolution.

42 ENGINEERING↗

Statistics of the charge spectrum of photo-multipliers and methods for absolute calibration

We derive the full expression for the shape of the charge spectrum that results from the illumination of a photo-multiplier tube. The derivation is for low intensity illumination with constant gain, a common condition for most nuclear and particle physics applications. Under these conditions, it is shown that an analytic expression can be formulated that describes details of the spectrum including the pedestal and dark noise with excellent fidelity to allow statistical fits to data. The derivation and full formula using either Gaussian or Poisson models for gain, and its limiting forms under various simplifying assumptions are presented with strategies on their use. The analytic description can be used to formulate data acquisition strategies to perform precise absolute calibration of photo-multipliers, the digitizers, and the data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction and commissioning of a technological prototype of a highly granular SiPM-on-tile scintillator-steel hadronic calorimeter

The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype of the Analog Hadron Calorimeter has been built, based on a design and construction techniques scalable to a collider detector. The prototype consists of a steel absorber structure and active layers of small scintillator tiles that are individually read out by directly coupled SiPMs. Each layer has an active area of 72 × 72 cm^2 and a tile size of 3 × 3 cm^2. With 38 active layers, the prototype has nearly 22,000 readout channels, and its total thickness amounts to 4.4 nuclear interaction lengths. The dedicated readout electronics provide time stamping of each hit with an expected resolution of about 1 ns. The prototype was constructed in 2017 and commissioned in beam tests at DESY. It recorded muons, hadron showers and electron showers at different energies in test beams at CERN in 2018. In this paper, the design of the prototype, its construction and commissioning are described. The methods used to calibrate the detector are detailed, and the performance achieved in terms of uniformity and stability is presented.

47 OTHER INSTRUMENTATION↗

A gain series method for accurate EMCCD calibration

Abstract Calibration of the gain and digital conversion factor of an EMCCD is necessary for accurate photon counting. We present a new method to quickly calibrate multiple gain settings of an EMCCD camera. Acquiring gain-series calibration data and analyzing the resulting images with the EMCCD noise model more accurately estimates the gain response of the camera. Furthermore, we develop a method to compare the results from different calibration approaches. Gain-series calibration outperforms all other methods in this self-consistency test.

36 MATERIALS SCIENCE↗

Photometric calibration in u -band using blue halo stars

ABSTRACT We develop a method to calibrate u-band photometry based on the observed colour of blue Galactic halo stars. The Galactic halo stars belong to an old stellar population of the Milky Way and have relatively low metallicity. The ‘blue tip’ of the halo population – the main sequence turn-off (MSTO) stars – is known to have a relatively uniform intrinsic edge u-g colour with only slow spatial variation. In SDSS data, the observed variation is correlated with Galactic Latitude, which we attribute to contamination by higher metallicity disc stars and fit with an empirical curve. This curve can then be used to calibrate u-band imaging if g-band imaging of matching depth is available. Our approach can be applied to single-field observations at |b| > 30°, and removes the need for standard star observations or overlap with calibrated u-band imaging. We include in our method the calibration of g-band data with ATLAS-Refcat2. We test our approach on stars in KiDS DR 4, ATLAS DR 4, and DECam imaging from the NOIRLab Source Catalog (NSC DR2), and compare our calibration with SDSS. For this process, we use synthetic magnitudes to derive the colour equations between these data sets, in order to improve zero-point accuracy. We find an improvement for all data sets, reaching a zero-point precision of 0.016 mag for KiDS (compared to the original 0.033 mag), 0.020 mag for ATLAS (originally 0.027 mag), and 0.016 mag for DECam (originally 0.041 mag). Thus, this method alone reaches the goal of 0.02 mag photometric precision in u-band for the Rubin Observatory’s Legacy Survey of Space and Time (LSST).

79 ASTRONOMY AND ASTROPHYSICS↗

Methods and apparatus for calibration and response time testing of level sensors

Systems and methods of diagnosing performance of a level sensor of a fluid test chamber, including a data acquisition and processing unit configured to receive output signals of one or more level sensors that are installed to a fluid chamber, the data acquisition and processing unit being configured to connect to the one or more level sensors to record and process the output signals to test operation of the one or more level sensors.

Hashemian, Alexander Hashem↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black carbon aerosol number and mass concentration measurements by picosecond short-range elastic backscatter lidar

Abstract Black carbon aerosol emissions are recognized as contributors to global warming and air pollution. There remains, however, a lack of techniques to remotely measure black carbon aerosol particles with high range and time resolution. This article presents a direct and contact-free remote technique to estimate the black carbon aerosol number and mass concentration at a few meters from the emission source. This is done using the Colibri instrument based on a novel technique, referred to here as Picosecond Short-Range Elastic Backscatter Lidar (PSR-EBL). To address the complexity of retrieving lidar products at short measurement ranges, we apply a forward inversion method featuring radiometric lidar calibration. Our method is based on an extension of a well-established light-scattering model, the Rayleigh–Debye–Gans for Fractal-Aggregates (RDG-FA) theory, which computes an analytical expression of lidar parameters. These parameters are the backscattering cross-sections and the lidar ratio for black carbon fractal aggregates. Using a small-scale Jet A-1 kerosene pool fire, we demonstrate the ability of the technique to quantify the aerosol number and mass concentration with centimetre range-resolution and millisecond time-resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Advancing earth system model calibration: a diffusion-based method

Understanding of climate impact on ecosystems globally requires site-specific model calibration. Here we introduce a novel diffusion-based uncertainty quantification (DBUQ) method for efficient model calibration. DBUQ is a score-based diffusion model that leverages Monte Carlo simulation to estimate the score function and evaluates a simple neural network to quickly generate samples for approximating parameter posterior distributions. DBUQ is stable, efficient, and can effectively calibrate the model given diverse observations, thereby enabling rapid and site-specific model calibration on a global scale. This capability significantly advances Earth system modeling and our understanding of climate impacts on Earth systems. We demonstrate DBUQ's capability in E3SM land model calibration at the Missouri Ozark AmeriFlux forest site. Both synthetic and real-data applications indicate that DBUQ produces accurate parameter posterior distributions similar to those generated by Markov Chain Monte Carlo sampling but with 30X less computing time. This efficiency marks a significant stride in model calibration, paving the way for more effective and timely climate impact analyses.

Liu, Yanfang↗

GEANT4 parameter tuning using Professor

The GEANT4 toolkit is used extensively in high energy physics to simulate the passage of particles through matter and to predict effects such as detector efficiencies and smearing. GEANT4 uses many underlying models to predict particle interaction kinematics, and uncertainty in these models leads to uncertainty in high energy physics measurements. The GEANT4 collaboration recently made free parameters in some models accessible through partnership with GEANT4 developers. We present a study of the impact of varying parameters in three GEANT4 hadronic physics models on agreement with thin target datasets and describe fits to these datasets using the Professor model tuning framework [1]. We find that varying parameters produces substantially better agreement with some datasets, but that more degrees of freedom are required for full agreement. This work is a first step towards a common framework for propagating uncertainties in GEANT4 models to high energy physics measurements, and we outline future work required to complete that goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Normalizing flows for domain adaptation when identifying Λ hyperon events

Here this study focuses on the application of a normalizing flow as a method of domain adaptation when classifying physics data. Normalizing flows offer a way to transform data points between two different distributions. The present study investigates a novel method of transforming latent representations of physics data to a normal distribution and then to a physics distribution again. The final distribution models a simulated distribution. After being transformed, the data can be classified by a neural network trained on labeled simulation data. The present study succeeds in training two normalizing flows that can transform between data (or simulation) and a Gaussian distribution.

47 OTHER INSTRUMENTATION↗

A direct detection method of galaxy intrinsic ellipticity-gravitational shear correlation in non-linear regimes using self-calibration

Intrinsic alignment (IA) of galaxies is a challenging source of contamination in the Cosmic shear (GG) signals. The galaxy intrinsic ellipticity-gravitational shear (IG) correlation is generally the most dominant component of such contamination for cross-correlating redshift bins. One of the most effective techniques to mitigate such contamination is the self-calibration (SC) method which extracts the IG correlation and allows for its removal from the GG signal. In a photometric survey, the SC method first extracts the galaxy number density-galaxy intrinsic ellipticity (gI) correlation from the observed galaxy-galaxy lensing correlation using the redshift dependence of lens-source pairs. The IG correlation is computed through a scaling relation using the gI correlation and other lensing observables. The applicability of the SC method has so far been focused on the linear IA scales and the linear galaxy bias. We extend the SC method beyond the linear regime by modifying its scaling relation which can account for the non-linear galaxy bias model and various IA models. In this study, we provide a framework to detect the IG correlation for the redshift bins for source galaxies for the proposed year 1 survey of the Rubin Legacy Survey of Space and Time (LSST Y1). We tested the method for the tidal alignment and tidal torquing (TATT) model of IA and we found that the scaling relation is accurate within 10% and 20% for cross-correlating and auto-correlating redshift bins, respectively. Hence the suppression of IG contamination in observed GG correlation can be accomplished with a factor of 10 and 5, for cross-correlating and auto-correlating redshift bins, respectively. We tested the method's robustness and found that the suppression of IG contamination by a factor of 5 is still achievable for all combinations of cross-correlating bins even with the inclusion of a moderate amount of uncertainties on IA and bias parameters, respectively. We also make available, a branch of the code FAST-PT to provide gI correlations up to 1-loop order term used by the new SC method.

gravitational lensing↗

AI-assisted detector design for the EIC (AID(2)E)

Artificial Intelligence is poised to transform the design of complex, large-scale detectors like ePIC at the future Electron Ion Collider. Featuring a central detector with additional detecting systems in the far forward and far backward regions, the ePIC experiment incorporates numerous design parameters and objectives, including performance, physics reach, and cost, constrained by mechanical and geometric limits. This project aims to develop a scalable, distributed AI-assisted detector design for the EIC (AID(2)E), employing state-of-the-art multiobjective optimization to tackle complex designs. Supported by the ePIC software stack and using G EANT 4 simulations, our approach benefits from transparent parameterization and advanced AI features. The workflow leverages the PanDA and iDDS systems, used in major experiments such as ATLAS at CERN LHC, the Rubin Observatory, and sPHENIX at RHIC, to manage the compute intensive demands of ePIC detector simulations. Tailored enhancements to the PanDA system focus on usability, scalability, automation, and monitoring. Ultimately, this project aims to establish a robust design capability, apply a distributed AI-assisted workflow to the ePIC detector, and extend its applications to the design of the second detector (Detector-2) in the EIC, as well as to calibration and alignment tasks. Additionally, we are developing advanced data science tools to efficiently navigate the complex, multidimensional trade-offs identified through this optimization process.

97 MATHEMATICS AND COMPUTING↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clumped 13 CH 2 D and 12 CHD 2 compositions of methyl groups from wood and synthetic monomers: Methods, experimental and theoretical calibrations, and initial results

Methyl groups are found in numerous biogenic and synthetic materials including geologically preserved materials such as wood. The carbon and hydrogen isotope compositions of methyl groups are used as tracers in biogeochemical cycles, as paleothermometers, and to determine the hydrogen isotopic composition of ancient rain. Here we present analyses of resolved 13 C–D ( 13 CH 2 D) and D–D ( 12 CHD 2 ) clumped isotope compositions of methyl groups as new variables for the study of methyl groups in the present and past. We first present chemical methods to extract, purify, and derivatize methyl groups from methoxyl (R–O–CH 3 ) groups as CH 3 F and CH 3 Cl, and high-resolution mass spectrometric techniques to determine the clumped isotope compositions of these species. We achieve precisions for 13 C–D clumping of ±0.25‰ and D–D clumping of ±2.5‰. We anchor our clumped isotopic measurements to a thermodynamic reference frame by first calculating the theoretical temperature dependences of 13 C–D and D–D clumping in CH 3 Cl, then placing our measurements onto this reference frame through experimental internal isotopic equilibration of CH 3 Cl at 200 °C. Finally, we provide and analyze an initial dataset of clumped 13 C–D and D–D compositions of methyl groups from various commercial/synthetic monomers and environmental woods. We observe ranges in clumped isotope compositions of ~11‰ in 13 C–D and ~48‰ in D–D, and systematic differences within these ranges between methyl groups from commercial monomers and wood. Specifically, commercial clumped 13 C–D compositions are between 0 and 3‰, which correspond to apparent equilibrium temperatures between 170 °C and the infinite temperature limit. In contrast, the clumped 13 C–D compositions of wood methoxyl groups are distinctively high (9.50–11.25‰) and 3–6‰ higher than would be expected if formed in internal isotopic equilibrium at Earth-surface temperatures. Commercial/synthetic methyl and wood methoxyl clumped D–D compositions are also distinct: -5 to +13‰ in commercial monomers vs. -35 to -8‰ in wood—such negative values cannot result from formation in isotopic equilibrium and require kinetic processes to have occurred. Overall, these results indicate that wood methoxyl groups are formed out of isotopic equilibrium and that clumped isotope compositions of methyl groups may be useful tracers of methyl group sources and sinks in the environment. For instance, isotopic clumping in methyl groups may be useful for understanding controls on isotopic clumping in methane produced by methylotrophic methanogens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physics-constrained fault diagnosis framework for monitoring a standalone component of a thermal hydraulic system

A method for diagnosing faults includes receiving a description of a component of a thermal hydraulic system, where the description also indicates one or more sensors of the component. The method also includes constructing, based on a physical conservation law and using the description, a physics-based model describing operation of the component, the physics-based model including one or more unknown parameters. The method further includes calibrating the physics-based model by calculating the one or more unknown parameters using historical measurements to produce a calibrated model. Further, the method includes receiving sensor measurements captured by the one or more sensors, and calculating residuals corresponding to differences between measurements predicted by the calibrated model and the sensor measurements. The method also includes determining, based on the calculated residuals, a fault of the component or of a sensor of the one or more sensors, and generating an alert indicating the fault.

Nguyen, Tat Nghia↗