Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Exploring the Chemical Link Between Local Ellipticals and Their High-Redshift Progenitors

We present Keck/MOSFIRE K-band spectroscopy of the first mass-selected sample of galaxies at z approximately 2.3. Targets are selected from the 3D-Hubble Space Telescope Treasury survey. The six detected galaxies have a mean [N II]lambda6584/H-alpha ratio of 0.27 +/- 0.01, with a small standard deviation of 0.05. This mean value is similar to that of UV-selected galaxies of the same mass. The mean gas-phase oxygen abundance inferred from the [N II]/Halpha ratios depends on the calibration method, and ranges from 12+log(O/H)(sub gas) = 8.57 for the Pettini & Pagel calibration to 12+log(O/H)(sub gas) = 8.87 for the Maiolino et al. calibration. Measurements of the stellar oxygen abundance in nearby quiescent galaxies with the same number density indicate 12+log(O/H)(sub stars) = 8.95, similar to the gas-phase abundances of the z approximately 2.3 galaxies if the Maiolino et al. calibration is used. This suggests that these high-redshift star forming galaxies may be progenitors of today's massive early-type galaxies. The main uncertainties are the absolute calibration of the gas-phase oxygen abundance and the incompleteness of the z approximately 2.3 sample: the galaxies with detected Hα tend to be larger and have higher star formation rates than the galaxies without detected H-alpha, and we may still be missing the most dust-obscured progenitors.

Chemical↗

Study Methods to Standardize Thermography NDE

The purpose of this work is to develop thermographic inspection methods and standards for use in evaluating structural composites and aerospace hardware. Qualification techniques and calibration methods are investigated to standardize the thermographic method for use in the field. Along with the inspections of test standards structural hardware, support hardware is designed and fabricated to aid in the thermographic process. Also, a standard operating procedure is developed for performing inspections with the Bales Thermal Image Processor (TIP). Inspections are performed on a broad range of structural composites. These materials include various graphite/epoxies, graphite/cyanide-ester, graphite/silicon-carbide, graphite phenolic and Keviar/epoxy. Also metal honeycomb (titanium and aluminum faceplates over an aluminum honeycomb core) structures are investigated. Various structural shapes are investigated and the thickness of the structures vary from as few as 3 plies to as many as 80 plies. Special emphasis is placed on characterizing defects in attachment holes and bondlines, in addition to those resulting from impact damage and the inclusion of foreign matter. Image processing through statistical analysis and digital filtering is investigated to enhance the quality and quantify the NDE thermal images when necessary.

Walker, James L.↗

Study Methods to Standardize Thermography NDE

The purpose of this work is to develop thermographic inspection methods and standards for use in evaluating structural composites and aerospace hardware. Qualification techniques and calibration methods are investigated to standardize the thermographic method for use in the field. Along with the inspections of test standards structural hardware, support hardware is designed and fabricated to aid in the thermographic process. Also, a standard operating procedure is developed for performing inspections with the Bales Thermal Image Processor (TIP). Inspections are performed on a broad range of structural composites. These materials include graphite/epoxies, graphite/cyanide-ester, graphite/silicon-carbide, graphite phenolic and Kevlar/epoxy. Also metal honeycomb (titanium and aluminum faceplates over an aluminum honeycomb core) structures are investigated. Various structural shapes are investigated and the thickness of the structures vary from as few as 3 plies to as many as 80 plies. Special emphasis is placed on characterizing defects in attachment holes and bondlines, in addition to those resulting from impact damage and the inclusion of foreign matter. Image processing through statistical analysis and digital filtering is investigated to enhance the quality and quantify the NDE thermal images when necessary.

Walker, James L.↗

Optical See-Through Head Mounted Display Direct Linear Transformation Calibration Robustness in the Presence of User Alignment Noise

Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.

Axholt, Magnus↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

Spectroradiometric calibration of the thematic mapper and multispectral scanner system

A list of personnel who have contributed to the program is provided. Sixteen publications and presentations are also listed. A preprint summarizing five in-flight absolute radiometric calibrations of the solar reflective bands of the LANDSAT-5 Thematic Mapper is presented. The 23 band calibrations made on the five dates show a 2.5% RMS variation from the mean as a percentage of the mean. A preprint is also presented that discusses the reflectance-based results of the above preprint. It proceeds to analyze and present results of a second, independent calibration method based on radiance measurements from a helicopter. Radiative transfer through the atmosphere, model atmospheres, the calibration methodology used at White Sands and the results of a sensitivity analysis of the reflectance-based approach is also discussed.

Slater, Philip N.↗

Calibration Plans for the Global Precipitation Measurement (GPM)

The Global Precipitation Measurement (GPM) is an international effort led by the National Aeronautics and Space Administration (NASA) of the U.S.A. and the National Space Development Agency of Japan (NASDA) for the purpose of improving research into the global water and energy cycle. GPM will improve climate, weather, and hydrological forecasts through more frequent and more accurate measurement of precipitation world-wide. Comprised of U.S. domestic and international partners, GPM will incorporate and assimilate data streams from many spacecraft with varied orbital characteristics and instrument capabilities. Two of the satellites will be provided directly by GPM, the core satellite and a constellation member. The core satellite, at the heart of GPM, is scheduled for launch in November 2007. The core will carry a conical scanning microwave radiometer, the GPM Microwave Imager (GMI), and a two-frequency cross-track-scanning radar, the Dual-frequency Precipitation Radar (DPR). The passive microwave channels and the two radar frequencies of the core are carefully chosen for investigating the varying character of precipitation over ocean and land, and from the tropics to the high-latitudes. The DPR will enable microphysical characterization and three-dimensional profiling of precipitation. The GPM-provided constellation spacecraft will carry a GMI radiometer identical to that on the core spacecraft. This paper presents calibration plans for the GPM, including on-board instrument calibration, external calibration methods, and the role of ground validation. Particular emphasis is on plans for inter-satellite calibration of the GPM constellation. With its Unique instrument capabilities, the core spacecraft will serve as a calibration transfer standard to the GPM constellation. In particular the Dual-frequency Precipitation Radar aboard the core will check the accuracy of retrievals from the GMI radiometer and will enable improvement of the radiometer retrievals. Observational intersections of the core with the constellation spacecraft are essential in applying this technique to the member satellites. Information from core spacecraft retrievals during intersection events will be transferred to the constellation radiometer instruments in the form of improved calibration and, with experience, improved radiometric algorithms. In preparation for the transfer standard technique, comparisons using the Tropical Rainfall Measuring Mission (TRMM) with sun-synchronous radiometers have been conducted. Ongoing research involves study of critical variables in the inter-comparison, such as correlation with spatial-temporal separation of intersection events, frequency of intersection events, variable azimuth look angles, and variable resolution cells for the various sensors.

Bidwell, S. W.↗

Methods for Radiometric Cross-Calibration of Imaging Sensors With and Without Overlapping Collections

This slide presentation reviews methods of cross calibration for imaging sensors. Cross calibration methods fall under two categories: (1) Relies on knowledge of a source that is common to both sensors, (2) Typically near-coincident views. Some work has used methods that do not require simultaneous data collections. This talk discusses the International System of Units (SI) -traceable approaches that permit cross-calibration. It describes on-orbit cross-calibration methods that are typically used, with and without overlapping views. It reviews sample results. It also describes a method without overlapping views and without on-site measurements.

Thome, K. J.↗

Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

Lerch, B. A.↗

Detection of fatigue cracks by nondestructive testing methods

The effectiveness was assessed of various NDT methods to detect small tight cracks by randomly introducing fatigue cracks into aluminum sheets. The study included optimizing NDT methods calibrating NDT equipment with fatigue cracked standards, and evaluating a number of cracked specimens by the optimized NDT methods. The evaluations were conducted by highly trained personnel, provided with detailed procedures, in order to minimize the effects of human variability. These personnel performed the NDT on the test specimens without knowledge of the flaw locations and reported on the flaws detected. The performance of these tests was measured by comparing the flaws detected against the flaws present. The principal NDT methods utilized were radiographic, ultrasonic, penetrant, and eddy current. Holographic interferometry, acoustic emission monitoring, and replication methods were also applied on a reduced number of specimens. Generally, the best performance was shown by eddy current, ultrasonic, penetrant and holographic tests. Etching provided no measurable improvement, while proof loading improved flaw detectability. Data are shown that quantify the performances of the NDT methods applied.

Anderson, R. T.↗

Interchangeable end effector tools utilized on the PFMA

An instrumented task board, used for measuring forces applied by the Protoflight Manipulator Arm (PFMA) to the task board, was fabricated and delivered to Marshall Space Flight Center. SRS Technologies phased out the existing IBM compatible data acquisition system, used with a instrumented task board, and integrated the force measuring electronic hardware in with the Macintosh II data acquisition system. The purpose of this change was to acquire all data with the same time tag, allowing easier and more accurate data reduction in addition to real-time graphics. A three-dimensional optical position sensing system for determining the location of the PFMA's end effect or in reference to the center of the instrumented task board was also designed and delivered under. An improved task board was fabricated which included an improved instrumented beam design. The modified design of the task board improved the force/torque measurement system by increasing the sensitivity, reliability, load range and ease of maintenance. A calibration panel for the optical position system was also designed and fabricated. The calibration method developed for the position sensors enhanced the performance of the sensors as well as simplified the installation and calibration procedures required. The modifications made under this effort expanded the capabilities of the task board system. The system developed determines the arm's position relative to the task board and measures the signals to the joints resulting from the operator's control signals in addition to the task board forces. The software and hardware required to calculate and record the position of the PFMA during the performance of tasks with the instrumented task board were defined, designed and delivered to MSFC. PFMA joint input signals can be measured from a breakout box to evaluate the sensitivity or response of the arm operation to control commands. The data processing system provides the capability for post processing of time-history graphics and plots of the PFMA positions, the operator's actions, and the PFMA servo reactions in addition to realtime force and position sensor data presentation.

Cody, Joe↗

Calibration of the Geosar Dual Frequency Interferometric SAR

GeoSAR is an airborne, interferometric Synthetic Aperture Radar (INSAR) system for terrain mapping, currently under development by a consortium including NASA's Jet Propulsion Laboratory (JPL), Calgis, Inc., and the California Department of Conservation (CalDOC) with funding provided by the Topographic Engineering Center (TEC) of the U.S. Army Corps of Engineers and the Defense Advanced Research Projects Agency (DARPA). The radar simultaneously maps swaths on both sides of the aircraft at two frequencies, X-Band and P-Band. For the P-Band system, data is collected for two across track interferometric baselines and at the crossed polarization. The aircraft position and attitude are measured using two Honeywell Embedded GPS Inertial Navigation Units (EGI) and an Ashtech Z12 GPS receiver. The mechanical orientation and position of the antennas are actively measured using a Laser Baseline Metrology System (LBMS). In the GeoSAR motion measurement software, these data are optimally combined with data from a nearby ground station using Ashtech PNAV software to produce the position, orientation, and baseline information are used to process the dual frequency radar data. Proper calibration of the GeoSAR system is essential to obtaining digital elevation models (DEMS) with the required sub-meter level planimetric and vertical accuracies. Calibration begins with the determination of the yaw and pitch biases for the two EGI units. Common range delays are determined for each mode, along with differential time and phase delays between channels. Because the antennas are measured by the LBMS, baseline calibration consists primarily of measuring a constant offset between mechanical center and the electrical phase center of the antennas. A phase screen, an offset to the interferometric phase difference which is a function of absolute phase, is applied to the interferometric data to compensate for multipath and leakage. Calibration parameters are calculated for each of the ten processing modes, each of the operational bandwidths (80 and 160 MHZ), and each aircraft altitude. In this talk we will discuss the layout calibration sites, the synthesis of data from multiple flights to improve the calibration, methods for determining time and phase delays, and techniques for determining radiometric and polarimetric quantities. We will describe how calibration quantities are incorporated into the processor and pre-processor. We will demonstrate our techniques applied to GeoSar data and assess the stability and accuracy of the calibration. This will be compared to the modeled performance determined from calibrating the output of a point target simulator. The details of baseline determination and phase screen calculation are covered in related talks.

Chapine, Elaine↗

Method for Accurately Calibrating a Spectrometer Using Broadband Light

A novel method has been developed for performing very fine calibration of a spectrometer. This process is particularly useful for modern miniature charge-coupled device (CCD) spectrometers where a typical factory wavelength calibration has been performed and a finer, more accurate calibration is desired. Typically, the factory calibration is done with a spectral line source that generates light at known wavelengths, allowing specific pixels in the CCD array to be assigned wavelength values. This method is good to about 1 nm across the spectrometer s wavelength range. This new method appears to be accurate to about 0.1 nm, a factor of ten improvement. White light is passed through an unbalanced Michelson interferometer, producing an optical signal with significant spectral variation. A simple theory can be developed to describe this spectral pattern, so by comparing the actual spectrometer output against this predicted pattern, errors in the wavelength assignment made by the spectrometer can be determined.

Simmons, Stephen↗

Status of the GSICS VIS/NIR DCC Calibration Efforts

This year's goals for the GSICS VIS/NIR group is to finalize the VIS/NIR demonstration product requirements and to process the product for public dissemination provided on the GSICS web page. The GSICS VIS/NIR group members have been working on a unified calibration approach among various agencies. Two calibration methods have been chosen for the visible bands, deep convective clouds (DCC) and lunar invariant targets. To come to consensus across the agencies, each step of the DCC process will be outlined. Brief discussions are to follow to determine any outstanding issues. The presentation will review the DCC calibration process implemented by the CERES calibration team. CERES has already implemented the DCC method across 18 geostationary satellites. The various agencies have taken the framework and optimized the method for their particular geostationary satellite. Several new improvements will be discussed, such as deseasonalization of the DCC reflectances, impact of the bidirectional model, and update frequency.

David Doelling↗

Spectral calibration analysis of the airborne oceanographic lidar

Efforts were concentrated on the spectral resolution of the Airborne Oceanographic Lidar (AOL). This year's work was targeted towards the analysis of calibration techniques to enable the AOL to measure absolute radiances of both passive and active modes of operation. Absolute spectral calibration of the AOL is necessary in order to fully understand and monitor the sensitivity and stability of the total system. Calibration is also needed to obtain valid surface truth data, with which to improve the accuracy of satellite-borne oceanic color scanners. In particular, accurate measurements of oceanic chlorophyll concentrations rests upon reliable irradiance calibrations of both laser induced and solar induced chlorophyll fluoresence. An analysis was performed on the spectral calibration methods used by the AOL. The optical path of the instrumentation was examined to study how the radiance from a calibration sphere was influenced. Ray tracing analysis was performed, including the Cassegrain-telescope optics. It was determined that the calibration radiance was significantly effected by optical-defocusing, due to close positioning of the calibration sphere with respect to the telescope. Since the multi-mode usages of the AOL require varying altitudes and trajectories, a computational algorithm was developed to compensate for image distortions of the telescope optics. Secondary mirror blockage, secondary vignetting, and beam divergence was determined, in order to account for the actual amount of calibrated flux received at the spectral sensors.

Rousey, Carlton E.↗

Measurement of model propulsion system noise in a low-speed wind tunnel

Methods are presented for making overall and directional acoustic measurements with forward velocity in the Lewis 9 x 15 V/STOL wind tunnel. Overall acoustic measurements are discussed; the acoustic calibration methods, instrumentation features, and types of experiments are presented. Selected data are presented as examples of the various types of overall measurements that are possible. The method of making directional acoustic measurements is presented, and the necessary alterations to the tunnel, specialized acoustic instrumentation, and calibration details are described. The results indicate that relative overall acoustic measurements can be made successfully and that directional acoustic measurements are feasible.

Diedrich, J. H.↗

ExEP: Initial super-Nyquist wavefront control experiments in the Decadal Survey Testbed

In order to characterize exoplanets around nearby stars, upcoming and proposed space telescopes are being designed with high contrast coronagraph instruments. Coronagraphs are generally designed to suppress only a single, on-axis star, but there are numerous binary star systems within our observational range. Multi-star wavefront correction (MSWC) is a technique that uses deformable mirror(s) to simultaneously suppress light from more than one star to create a high contrast dark zone in the image. MSWC has already been well demonstrated in simulation and in air-based testbeds. In this paper, we describe our prepatory vacuum experiments in the Decadal Survey Testbed (DST) at the Jet Propulsion Laboratory. First we implemented super-Nyquist wavefront control (SNWC, a critical component of MSWC), and then we proceeded to simultaneous sub- and super-Nyquist control. With our existing calibration methods, SNWC reached a contrast of $8.6{\times}10^{-9}$ in a 10\% bandpass around a first-order diffraction spot; calibration improvements are needed to improve model agreement for higher-order spots. We have also implemented changes to our software (the open-source package FALCO) required for MSWC, and identified the necessary changes in hardware. Here we report our best SNWC lab results and our plans for implementing MSWC during a future set of experiments.

Bendek, Eduardo↗