Efficiency and cost advantages of an advanced-technology nuclear electrolytic hydrogen-energy production facility

The concept of an advanced-technology (viz., 1985 technology) nuclear-electrolytic water electrolysis facility was assessed for hydrogen production cost and efficiency expectations. The facility integrates (1) a high-temperature gas-cooled nuclear reactor (HTGR) operating a binary work cycle, (2) direct-current (d-c) electricity generation via acyclic generators, and (3) high-current-density, high-pressure electrolyzers using a solid polymer electrolyte (SPE). All subsystems are close-coupled and optimally interfaced for hydrogen production alone (i.e., without separate production of electrical power). Pipeline-pressure hydrogen and oxygen are produced at 6900 kPa (1000 psi). We found that this advanced facility would produce hydrogen at costs that were approximately half those associated with contemporary-technology nuclear electrolysis: $5.36 versus $10.86/million Btu, respectively. The nuclear-heat-to-hydrogen-energy conversion efficiency for the advanced system was estimated as 43%, versus 25% for the contemporary system.

Donakowski, T. D.↗

Comparative assessment of orbital and terrestrial central power plants

Recent studies of the space power system (SPS) are integrated into a total social cost framework developed for terrestrial central electric power systems. Total social costs include the projection of commercial economics to the time frame of interest as well as the federal research, development and demonstration (RD&D) costs, the health impacts, the resources required, the environmental impacts and other social costs. The SPS system is limited to transporting all materials from the earth's surface to geosynchronous orbit. Only silicon photovoltaic is considered as the SPS energy conversion technique. Costs and impacts of the LWR are considered as a reference for nuclear systems, and the low BTU coal gasification with combined cycle gas and steam turbines is considered as a reference for a fossil central electric plant. The ground solar systems considered are solar thermal using the central receiver approach with thermal storage, and solar photovoltaic using the silicon cell with battery storage.

Caputo, R.↗

Supercritical oxygen heat transfer

Heat transfer to supercritical oxygen was experimentally measured in electrical heated tubes. Experimental data were obtained for pressures ranging from 17 to 34.5 MPa (2460 to 5000 psia), and heat fluxes from 2 to 90 million w/sq cm (1.2 to 55 Btu/(sq in. sec)). Bulk temperatures ranged from 96 to 217 K (173 to 391 R). Experimental data obtained by other investigators were added to this to increase the range of pressure down to 2 MPa (290 psia) and increase the range of bulk temperature up to 566 K (1019 R). From this compilation of experimental data a correlating equation was developed which predicts over 95% of the experimental data within + or - 30%.

Spencer, R. G.↗

Design and fabrication of a radiative actively cooled honeycomb sandwich structural panel for a hypersonic aircraft

The panel assembly consisted of an external thermal protection system (metallic heat shields and insulation blankets) and an aluminum honeycomb structure. The structure was cooled to temperature 442K (300 F) by circulating a 60/40 mass solution of ethylene glycol and water through dee shaped coolant tubes nested in the honeycomb and adhesively bonded to the outer skin. Rene'41 heat shields were designed to sustain 5000 cycles of a uniform pressure of + or - 6.89kPa (+ or - 1.0 psi) and aerodynamic heating conditions equivalent to 136 kW sq m (12 Btu sq ft sec) to a 422K (300 F) surface temperature. High temperature flexible insulation blankets were encased in stainless steel foil to protect them from moisture and other potential contaminates. The aluminum actively cooled honeycomb sandwich structural panel was designed to sustain 5000 cycles of cyclic in-plane loading of + or - 210 kN/m (+ or - 1200 lbf/in.) combined with a uniform panel pressure of + or - 6.89 kPa (?1.0 psi).

Ellis, D. A.↗

Applications of thermal energy storage in the cement industry

In the manufacture of cement, literally trillions of Btu's are rejected to the environment each year. The purpose of this feasibility study program was to determine whether thermal energy storage could be used to conserve or allow alternative uses of this rejected energy. This study identifies and quantifies the sources of rejected energy in the cement manufacturing process, established use of this energy, investigates various storage system concepts, and selects energy conservation systems for further study. Thermal performance and economic analyses are performed on candidate storage systems for four typical cement plants representing various methods of manufacturing cement. Through the use of thermal energy storage in conjunction with waste heat electric power generation units, an estimated 2.4 x 10 to the 13th power Btu/year, or an equivalent on investment of the proposed systems are an incentive for further development.

Jaeger, F. A.↗

Open-Cycle Gas Turbine/Steam Turbine Combined Cycles with synthetic fuels from coal

The Open-Cycle Gas Turbine/Steam Turbine Combined Cycle can be an effective energy conversion system for converting coal to electricity. The intermediate step in this energy conversion process is to convert the coal into a fuel acceptable to a gas turbine. This can be accomplished by producing a synthetic gas or liquid, and by removing, in the fuel conversion step, the elements in the fuel that would be harmful to the environment if combusted. In this paper, two open-cycle gas turbine combined systems are evaluated: one employing an integrated low-Btu gasifier, and one utilizing a semi-clean liquid fuel. A consistent technical/economic information base is developed for these two systems, and is compared with a reference steam plant burning coal directly in a conventional furnace.

Shah, R. P.↗

A synoptic description of coal basins via image processing

An existing image processing system is adapted to describe the geologic attributes of a regional coal basin. This scheme handles a map as if it were a matrix, in contrast to more conventional approaches which represent map information in terms of linked polygons. The utility of the image processing approach is demonstrated by a multiattribute analysis of the Herrin No. 6 coal seam in Illinois. Findings include the location of a resource and estimation of tonnage corresponding to constraints on seam thickness, overburden, and Btu value, which are illustrative of the need for new mining technology.

Farrell, K. W., Jr.↗

Shock tube and shock wave research; Proceedings of the Eleventh International Symposium, University of Washington, Seattle, Wash., July 11-14, 1977

Papers are presented on the applications of shock-wave technology to the study of hydrodynamics, the use of the pressure-wave machine for charging diesel engines, and measurements of the heat-transfer rate in gas-turbine components. Consideration is given to shock propagation along 90-degree bends, the explosive dissemination of liquids, and rotational and vibrational relaxation behind weak shock waves in water vapor. Shock phenomena associated with expansion flows are described and stratospheric-related research using the shock tube is outlined. Attention is given to shock-wave ignition of magnesium powders, Mach reflection and boundary layers, and transition in the shock-induced unsteady boundary layer on a flat plate. Shock-tube measurements of induction and post-induction rates for low-Btu gas mixtures are presented and shock-initiated ignition in COS-N2O-Ar mixtures is described. Cluster growth rates in supersaturated lead vapor are presented and a study of laser-induced plasma motion in a solenoidal magnetic field is reviewed.

Ahlborn, B.↗

Residential solar hot water system--Tempe, Arizona

Domestic hot water for single story home is heated by two 4 by 8 foot solar collectors. Solar energy saved 5.54 million Btu in six month period; savings with increased water consumption would be significantly higher.

Source record↗

Solar water-heating performance evaluation-San Diego, California

Report describes energy saved by replacing domestic, conventional natural gas heater with solar-energy subsystem in single-family residence near San Diego, California. Energy savings for 6 month test period averaged 1.089 million Btu. Collector array covered 65 square feet and supplied hot water to both 66-gallon solar storage tank and 40-gallon tank for domestic use. Natural gas supplied house's auxiliary energy.

Source record↗

Solar heating for an observatory--Lincoln, Nebraska

Report describes solar-energy system for 50 seat observatory that provides 60 percent of space heating needs. System includes 9 flat-plate collectors, rock storage bin, blowers, controls, ducting, and auxiliary natural-gas furnace; it has five operation modes. Net energy savings were 11.31 million Btu for 12 months, or equivalent of 1.9 barrels of oil. Report appendixes list performance factor definitions, performance equations, and average area weather conditions.

Source record↗

Single-family-residence solar heating--Carlsbad, New Mexico

Solar-heating and hot-water system includes 408 square feet of flat-plate air collectors, rock storage bin, energy transport system, air-to-water heat exchanger, controls, and hot-water preheat tank. Hot-air oil furnace supplies auxiliary space heating, and electricity powers air-handler blower and hot water preheat pump. For 12 month period, system provided 43 percent of space-heating and 53 percent of hot-water energy; net energy savings were 23.072 million Btu.

Source record↗

Solar-heated ranger station--Glendo, Wyoming

Report evaluates solar-energy system in residential ranger station. Installation provided 22 percent of space-heating and 58 percent of hot-water energy requirements. Annual net energy savings were 30 million Btu. Report describes system and its subsystems: collector array, storage, hot-water, and space-heating. Average weather conditions of test site, performance values, and energy savings are listed.

Source record↗

Residential system--Lansing, Michigan

Air collectors are combined with water storage to supply 15 percent of space-heating and hot-water load to residence. Report discusses typical system operation, energy savings, and miantenance for 11 month period. Although unusual combination of water storage with air collecting medium creates loss of heat exchanging efficiency, net energy savings were 21 million Btu.

Source record↗

Solar space-heating system--Yosemite National Park, California

A 12 months performance of Visitors Center installation suffered from low insolation, high energy dissipation, and equipment breakdown. System has 980 square feet of liquid flat-plate collectors, water energy storage, 4-mode control, heat exchangers, pumps, and plumbing. Design expected system to supply over 50 percent of annual heating demand, but only 109 million Btu were conserved.

Source record↗

The NASA bus communications listening device software

The development of the bus listener is presented. Special software was developed to control the 'bus interface units' (BIU) connecting each of these devices to a communications cable to form the bus communication network. The code used in the BTU is described.

Allen, M. A.↗

Parametric study of potential early commercial MHD power plants

Three different reference power plant configurations were considered with parametric variations of the various design parameters for each plant. Two of the reference plant designs were based on the use of high temperature regenerative air preheaters separately fired by a low Btu gas produced from a coal gasifier which was integrated with the power plant. The third reference plant design was based on the use of oxygen enriched combustion air preheated to a more moderate temperature in a tubular type metallic recuperative heat exchanger which is part of the bottoming plant heat recovery system. Comparative information was developed on plant performance and economics. The highest net plant efficiency of about 45 percent was attained by the reference plant design with the use of a high temperature air preheater separately fired with the advanced entrained bed gasifier. The use of oxygen enrichment of the combustion air yielded the lowest cost of generating electricity at a slightly lower plant efficiency. Both of these two reference plant designs are identified as potentially attractive for early MHD power plant applications.

Hals, F. A.↗