Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biosensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Super-Sensitive and Robust Biosensors from Supported Polymer Bilayers

Biological organisms are potentially the most sensitive and selective biological detection systems known, yet we are currently severely limited in our ability to exploit biological interactions in sensory devices, due in part to the limited stability of biological systems and derived materials. This proposal addresses an important aspect of integrating biological sensory materials in a solid state device. If successful, such technology could enable entirely new classes of robust biosensors that could be miniaturized and deployed in the field. The critical aims of the proposed work were 1) the calibration of a more versatile approach to measuring pH, 2) the use of this method to monitor pH changes caused by the light-induced pumping of protons across vesicles with bacteriorhodopsin integrated into the membranes (either polymer or lipid); 3) the preparation of bilayer assemblies on platinum surfaces; 4) the enhanced detection of lightinduced pH changes driven by bR-loaded supported bilayers. I have developed a methodology that may enable that at interfaces and developed a methodology to characterize the functionality of bilayer membranes with reconstituted membrane proteins. The integrity of the supported bilayer films however must be optimized prior to the full realization of the work originally envisioned in the original proposal. Nevertheless, the work performed on this project and the encouraging results it has produced has demonstrated that these goals are challenging yet within reach.

36 MATERIALS SCIENCE↗

Lighting the way to bioproducts: Smart microbial biosensors for conversion pathway design

For several years, Los Alamos scientists have been taking advantage of the molecular machinery within microbial cells to produce fuel precursors and bioproduct building blocks. Today, they are improving this process by adding a biosensor to the microbes that will use fluorescence to tell them how efficiently the product is made—thus enabling high throughput screening to increase overall yield.

59 BASIC BIOLOGICAL SCIENCES↗

Amplification-free nucleic acid detection with a fluorescence-based waveguide biosensor

Early detection of pathogens using nucleic acids in clinical samples often requires sensitivity at the single-copy level, which currently necessitates time-consuming and expensive nucleic acid amplification. Here, we describe 1) a redesigned flow cell in the shape of a trapezoid-subtracted geometric stadium, and 2) modified experimental procedures that allow for the measurement of sub-attomolar analytes in microliter quantities on a fluorescence-based waveguide biosensor. We verified our instrumental sensitivity with a 200-μL sample of a fluorescent streptavidin conjugate at 100 zM (100 zeptomolar, or 100·10 −21 mol L −1 ) and theoretically explored the applicability of this modified sensing platform in a sandwich immunoassay format using a Langmuir adsorption model. We present assays that demonstrate specific detection of synthetic influenza A DNA (in buffer) and RNA (in saliva) oligonucleotides at the single-copy level (200 μL at 10 zM) using a fluorescent molecular beacon. Lastly, we demonstrate detection of isolated genomic influenza A RNA at a clinically relevant concentration. This work constitutes a sensitivity improvement of over twelve orders of magnitude compared to our previous nucleic acid detection work, illustrating the significant enhancements that can be gained with optimized experimental design.

59 BASIC BIOLOGICAL SCIENCES↗

Microbiota functional activity biosensors for characterizing nutrient metabolism in vivo

Methods for measuring gut microbiota biochemical activities in vivo are needed to characterize its functional states in health and disease. To illustrate one approach, an arabinan-containing polysaccharide was isolated from pea fiber, its structure defined, and forward genetic and proteomic analyses used to compare its effects, versus unfractionated pea fiber and sugar beet arabinan, on a human gut bacterial strain consortium in gnotobiotic mice. We produced ‘Microbiota Functional Activity Biosensors’ (MFABs) consisting of glycans covalently linked to the surface of fluorescent paramagnetic microscopic glass beads. Three MFABs, each containing a unique glycan/fluorophore combination, were simultaneously orally gavaged into gnotobiotic mice, recovered from their intestines, and analyzed to directly quantify bacterial metabolism of structurally distinct arabinans in different human diet contexts. Colocalizing pea-fiber arabinan and another polysaccharide (glucomannan) on the bead surface enhanced in vivo degradation of glucomannan. MFABs represent a potentially versatile platform for developing new prebiotics and more nutritious foods.

59 BASIC BIOLOGICAL SCIENCES↗

Fluorescence based biosensor

A novel biosensor comprises at least one fluorophore and at least two quenchers, and is capable of selectively and specifically detecting the presence of an ion in the presence of other ions.

47 OTHER INSTRUMENTATION↗

Fluorescence based biosensor

A novel biosensor comprises at least one fluorophore and at least two quenchers, and is capable of selectively and specifically detecting the presence of an ion in the presence of other ions.

59 BASIC BIOLOGICAL SCIENCES↗

Heavy metal biosensor

Compositions and methods are provided for detection of certain heavy metals using bacterial whole cell biosensors.

47 OTHER INSTRUMENTATION↗

Method and system for real-time analysis of biosensor data

A method of biosensor-based detection of toxins includes the steps of providing a fluid to be analyzed having a plurality of photosynthetic organisms therein, wherein chemical, biological or radiological agents alter a nominal photosynthetic activity of the photosynthetic organisms. At a first time a measured photosynthetic activity curve is obtained from the photosynthetic organisms. The measured curve is automatically compared to a reference photosynthetic activity curve to determine differences therebetween. The presence of the chemical, biological or radiological agents, or precursors thereof, are then identified if present in the fluid using the differences.

47 OTHER INSTRUMENTATION↗

Magneto-optic biosensor using bio-functionalized magnetized nanoparticles

A biosensor utilizing bio-functionalized magnetic nanoparticles is provided. An external magnetic field is applied to a suspension of magnetic nanoparticles. A linearly polarized incident light is applied to the suspension of magnetic nanoparticles. A photocurrent from polarized light scattering by bio-functionalized magnetic nanoparticles in liquid is detected. The magneto-optic sensing technique is applied to a micro-fluidic channel for rapid and sensitive detection with a small sample amount, and subsequent magnetic separation for detoxification. This technique is used for the detection of Brownian relaxation with time sweep as well as frequency sweep. The magneto-optical sensor enables rapidly detecting changes in local dynamic properties of the magnetic nanoparticles in liquids and magnetic modulation of ferromagnetic particles in liquid provides increased signal sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Biosensors for detecting and/or neutralizing bioavailable uranium and related U-sensitive genetic molecular components, gene cassettes, vectors, genetic circuits, compositions, methods and systems

UO 2 F 2 biosensors, and related U-sensing and/or F-sensing genetic molecular components, genetic circuits, compositions, methods and systems are described, which in several embodiments can be used to detect and/or neutralize uranium and in particular bioavailable UO 2 F 2 .

Park, Dan Mcfarland↗

Quantitative multiplex detection of biomarkers on a waveguide-based biosensor using quantum dots

The quantitative, simultaneous detection of multiple biomarkers with high sensitivity and specificity is critical for biomedical diagnostics, drug discovery and biomarker characterization [Wilson 2006, Tok 2006, Straub 2005, Joos 2002, Jani 2000]. Detection systems relying on optical signal transduction are, in general, advantageous because they are fast, portable, inexpensive, sensitive, and have the potential for multiplex detection of analytes of interest. However, conventional immunoassays for the detection of biomarkers, such as the Enzyme Linked Immunosorbant Assays (ELISAs) are semi-quantitative, time consuming and insensitive. ELISA assays are also limited by high non-specific binding, especially when used with complex biological samples such as serum and urine (REF). Organic fluorophores that are commonly used in such applications lack photostability and possess a narrow Stoke's shift that makes simultaneous detection of multiple fluorophores with a single excitation source difficult, thereby restricting their use in multiplex assays. The above limitations with traditional assay platforms have resulted in the increased use of nanotechnology-based tools and techniques in the fields of medical imaging [ref], targeted drug delivery [Caruthers 2007, Liu 2007], and sensing [ref]. One such area of increasing interest is the use of semiconductor quantum dots (QDs) for biomedical research and diagnostics [Gao and Cui 2004, Voura 2004, Michalet 2005, Chan 2002, Jaiswal 2004, Gao 2005, Medintz 2005, So 2006 2006, Wu 2003]. Compared to organic dyes, QDs provide several advantages for use in immunoassay platforms, including broad absorption bands with high extinction coefficients, narrow and symmetric emission bands with high quantum yields, high photostablility, and a large Stokes shift [Michalet 2005, Gu 2002]. These features prompted the use of QDs as probes in biodetection [Michalet 2005, Medintz 2005]. For example, Jaiswal et al. reported long term multiple color imaging of live cells using QD-bioconjugates [Jaiswal 2003]. Gao [Gao 2004] and So [So 2006] have used QDs as probes for in-vivo cancer targeting and imaging. Medintz et al. reported self-assembled QD-based biosensors for detection of analytes based on energy transfer [Medintz 2003]. Others have developed an approach for multiplex optical encoding of biomolecules using QDs [Han 2001]. Immunoassays have also benefited from the advantages of QDs. Recently, dihydrolipoic acid (DHLA) capped-QDs have been attached to antibodies and used as fluorescence reporters in plate-based multiplex immunoassays [Goodman 2004]. However, DHLA-QDs are associated with low quantum efficiency and are unstable at neutral pH. These problems limit the application of this technology to the sensitive detection of biomolecules, especially in complex biological samples. Thus, the development of a rapid, sensitive, quantitative, and specific multiplex platform for the detection of biomarkers in difficult samples remains an elusive target. The goal stated above has applications in many fields including medical diagnostics, biological research, and threat reduction. The current decade alone has seen the development of a need to rapidly and accurately detect potential biological warfare agents. For example, current methods for the detection of anthrax are grossly inadequate for a variety of reasons including long incubation time (5 days from time of exposure to onset of symptoms) and non-specific ('flu-like') symptoms. When five employees of the United State Senate were exposed to B. anthracis in the mail (2001), only one patient had a confirmed diagnosis before death. Since then, sandwich immunoassays using both colorimetric and fluorescence detectors have been developed for key components of the anthrax lethal toxin, namely protective antigen (PA), lethal factor (LF), and the edema factor [Mourez 2001]. While these platforms were successful in assays against anthrax toxins, the sensitivity was poor. Furthermore, no single platform exists for the simultaneous and quantitative detection of multiple components of the B. anthracis toxin. Addressing multiple biomarkers at the same time will increase confidence in a positive result, and may lead to application in the simultaneous detection of anthrax and other biowarfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate

Glyphosate is a globally applied herbicide yet it has been relatively undetectable in-field samples outside of gold-standard techniques. Its presumed nontoxicity toward humans has been contested by the International Agency for Research on Cancer, while it has been detected in farmers’ urine, surface waters and crop residues. Rapid, on-site detection of glyphosate is hindered by lack of field-deployable and easy-to-use sensors that circumvent sample transportation to limited laboratories that possess the equipment needed for detection. Herein, the flavoenzyme, glycine oxidase, immobilized on platinum-decorated laser-induced graphene (LIG) is used for selective detection of glyphosate as it is a substrate for GlyOx. The LIG platform provides a scaffold for enzyme attachment while maintaining the electronic and surface properties of graphene. The sensor exhibits a linear range of 10–260 µm, detection limit of 3.03 µm, and sensitivity of 0.991 nA µm -1 . The sensor shows minimal interference from the commonly used herbicides and insecticides: atrazine, 2,4-dichlorophenoxyacetic acid, dicamba, parathion-methyl, paraoxon-methyl, malathion, chlorpyrifos, thiamethoxam, clothianidin, and imidacloprid. Sensor function is further tested in complex river water and crop residue fluids, which validate this platform as a scalable, direct-write, and selective method of glyphosate detection for herbicide mapping and food analysis.

47 OTHER INSTRUMENTATION↗