Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biosensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bees as Biosensors: Chemosensory Ability, Honey Bee Monitoring Systems, and Emergent Sensor Technologies Derived from the Pollinator Syndrome

This review focuses on critical milestones in the development path for the use of bees, mainly honey bees and bumble bees, as sentinels and biosensors. These keystone species comprise the most abundant pollinators of agro-ecosystems. Pollinating 70%–80% of flowering terrestrial plants, bees and other insects propel the reproduction and survival of plants and themselves, as well as improve the quantity and quality of seeds, nuts, and fruits that feed birds, wildlife, and us. Flowers provide insects with energy, nutrients, and shelter, while pollinators are essential to global ecosystem productivity and stability. A rich and diverse milieu of chemical signals establishes and maintains this intimate partnership. Observations of bee odor search behavior extend back to Aristotle. In the past two decades great strides have been made in methods and instrumentation for the study and exploitation of bee search behavior and for examining intra-organismal chemical communication signals. In particular, bees can be trained to search for and localize sources for a variety of chemicals, which when coupled with emerging tracking and mapping technologies create novel potential for research, as well as bee and crop management.

54 ENVIRONMENTAL SCIENCES↗

An Imaging Surface Plasmon Resonance Biosensor Assay for the Detection of T-2 Toxin and Masked T-2 Toxin-3-Glucoside in Wheat

A sensitive, rapid, and reproducible imaging surface plasmon resonance (iSPR) biosensor assay was developed to detect T-2 toxin and T-2 toxin-3-glucoside (T2-G) in wheat. In this competitive assay, an amplification strategy was used after conjugating a secondary antibody (Ab 2 ) with gold nanoparticles. Wheat samples were extracted with a methanol/water mixture (80:20 v/v), then diluted with an equal volume of primary antibody (Ab1) for analysis. Matrix-matched calibration curves were prepared to determine T-2 toxin and T2-G. Recovery studies were conducted at three spiking levels in blank wheat. Mean recoveries ranged from 86 to 90%, with relative standard deviations for repeatability (RSDr) of less than 6%. Limits of detection were 1.2 ng/mL of T-2 toxin and 0.9 ng/mL of T2-G, equivalent to their levels in wheat, of 48 and 36 µg/kg, respectively. The developed iSPR assay was rapid and provided enough sensitivity for the monitoring of T-2 toxin/T2-G in wheat. This is the first iSPR assay useful for detecting the “masked” T2-G in wheat.

Food Science & Technology↗

BioSentinel: Developing a Space Radiation Biosensor

BioSentinel is an autonomous fully self-contained science mission that will conduct the first study of the biological response to space radiation outside low Earth orbit (LEO) in over 40 years. The 4-unit (4U) BioSentinel biosensor system, is housed within a 6-Unit (6U) spacecraft, and uses yeast cells in multiple independent microfluidic cards to detect and measure DNA damage that occurs in response to ambient space radiation. Cell growth and metabolic activity will be measured using a 3-color LED detection system and a metabolic indicator dye with a dedicated thermal control system per fluidic card.

Radiation biosensor↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Performance

During future human exploration missions, spaceflight crews will encounter adverse health outcomes and decrements in performance during the missions and for long term health. The Psychophysiological Research Lab is currently conducting a technology demonstration of a prototype wearable biosensor system (Astroskin) on astronaut surrogates during 30 day missions within NASAs Human Exploration Research Analog (HERA). HERA, located at Johnson Spaceflight Center, represents a flight analog for simulation of isolation, confinement and remote conditions of mission exploration scenarios. Astroskin, an autonomous medical monitoring system, consists of an intelligent garment for the upper body and a headband fitted with sensors, and associated software and hardware that can measure, transmit and store vital signs (ECG, respiration, blood pressure, etc.), sleep quality and activity level of the wearer. One of the main goals of the technology demonstration is to evaluate the performance of the Astroskin system (i.e., data quality), crew usability and comfort. To validate the Astroskin as a viable option for use during future spaceflight missions, crew data from HERA are sent to Ames researchers for processing and analyses. Crew surveys on usability and comfort will also be evaluated. This work supports the Exploration Medical Capabilities element within NASAs Human Research Program.

space analog↗

BioSentinel/Mars: Interplanetary Space Radiation Biosensor Experiment in Martian Transit on Mars 2020

Despite significant progress understanding biological radiation effects via terrestrial studies, no terrestrial source duplicates space’s unique radiation environment. Furthermore, no biological experiments have been conducted beyond low Earth orbit since Apollo. Understanding space’s fundamental biological effects requires overcoming these limitations. The BioSentinel 4U payload, under development for flight aboard Exploration Mission-1, measures biological responses to deep space radiation. Traveling to more than 1AU from Earth, BioSentinel/EM-1 will record DNA double-strand breaks (DSBs) repaired using a pathway common to humans and BioSentinel’s bioengineered yeast model organism, responding to as few as one biologically repaired DSB. The BioSentinel/Mars 4U instrument (6-8kg; 5-8W; 0.2-1MB/week) would include eighteen 16-well biosensor fluidic cards, activated biweekly during Mars 2020’s cruise phase, to provide a dose-dependent rate of DSB/repair. The instrument, which includes solid-state sensors for total ionizing dose and linear-energy-transfer spectra, addresses MEPAG SKG-B3 by simultaneously measuring both spectra and biological effects of space radiation. Biological measurements are rendered reliable by independent replicate experiments. The spatio-temporal uniformity of interplanetary galactic cosmic radiation makes BioSentinel/EM1 and BioSentinel/Mars approximate replicates, except for any major differences in solar particle events. Results will be compared to Earth and ISS controls to characterize the radiation/reduced-gravity parameter space by its biological impact.

BioSentinel↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Yeast Strain Development and Hardware Testing in Preparation of a Lunar BioSensor

With Artemis missions underway, it is clear we are going back to the Moon to stay. Before sending Astronauts for long-duration missions, it is crucial to understand the technological and biomedical countermeasures needed to protect them before they get there. We can use knowledge gained from biological CubeSats to guide the next generation of experiments to support human habitation on the Moon. Lunar Explorer Instrument for space biology Applications (LEIA) is NASA’s latest BioSensor, adapted BioSentinel, the only CubeSat to travel Beyond Low Earth Orbit. BioSentinel launched on Artemis I and is currently >50 million kilometers from Earth (as of July 2024). LEIA aims to identify biological responses to the Lunar environment, which unprotected against would pose a threat to astronauts (cancer, cardiovascular disease, neurological impairment). The suite of instruments within LEIA detects Lunar radiation using two on-board radiation sensors (ARES charged particle detector, Mini-Fast Neutron Detector), then monitors real-time biological responses to the Lunar environment via an autonomous microfluidic system, fit with 3-LED emitter and detector boards and the alamarBlue metabolic indicator dye. LEIA will use a genetic approach in addition to synthetic biology to test counter-measure production in space, with the goal to inform and protect astronauts for future Moon missions. We have conducted preliminary tests in preparation for launch to the anticipated South Pole of the Moon, optimizing the biology (strain down-selection, desiccation tolerance, radiation sensitivity) and improving the hardware (including a blue LED to detect the beta-carotene countermeasure product). Our team will discuss these findings in several parts – an overview of the LEIA mission (Mark Settles), adapting flexible CubeSat platforms for deep-space applications (Sergio Santa Maria, Kira Rienecker), developing new technologies to support LEIA ground studies (Chinmayee Govinda Raj), and yeast strain development and hardware testing in preparation for LEIA (presented here).

synthetic biology↗

R&D 100 Winner 2010: Acoustic Wave Biosensors

The acoustic wave biosensor is innovative device that is a handheld, battery-powered, portable detection system capable of multiplex identification of a wide range of medically relevant pathogens and their biomolecular signatures — viruses, bacteria, proteins, and DNA — at clinically relevant levels. This detection occurs within minutes — not hours — at the point of care, whether that care is in a physician's office, a hospital bed, or at the scene of a biodefense or biomedical emergency.

47 OTHER INSTRUMENTATION↗

A Universal Biosensor for Infectious Disease

With increased travel and globalization, the spread of new diseases has become a threat to global health—and global security. Whether in a rural village or an urban medical clinic, healthcare workers need diagnostics that provide answers then and there, for any disease, in order to effectively treat individual patients or widespread outbreaks. That’s why Harshini Mukundan and her team at Los Alamos National Laboratory are working to develop a universal biosensor. “If we are able to mimic the body’s immune recognition in the laboratory, we could have a universal strategy for the early diagnosis of all infections,” said Mukundan. Our immune system recognizes pathogens, regardless of their origin, by identifying discrete signatures in the human host. Mukundan's team is working to imitate this ability in the laboratory, which could lead to a simple solution to diagnose all diseases and improve lives across the world.

59 BASIC BIOLOGICAL SCIENCES↗

Design and analysis of graphene–MoS{sub 2} hybrid layer based SPR biosensor with TiO{sub 2}–SiO{sub 2} nano film for formalin detection: numerical approach

In this paper, a Surface Plasmon Resonance (SPR) biosensor has been numerically developed that used Graphene–MoS{sub 2}–Au–TiO{sub 2}–SiO{sub 2} hybrid structure for the detection of formalin. This developed sensor has been sensed the presence the formalin based on attenuated total reflection (ATR) method by observing the change of “surface plasmon resonance angle-the change of minimum reflectance attributor” and “the resonance frequency characteristics (RFC)-maximum transmittance attributor”. Chitosan has been used as probe sensing medium to accelerate particular reaction with the formalin. Here, graphene is used as biomolecular recognition element because of its high adsorption ability and optical characteristics which helps to improve sensor sensitivity, MoS{sub 2} used for it has larger band gap, high fluroscence quenching ability, higher optical absorption efficiency, TiO{sub 2}–SiO{sub 2} bilayer as the improvement of sensitivity and Gold (Au) as the sharp SPR curve. Numerical results give the impression that the variation of RFC and SPR angle for improper sensing of formalin is quiet negligible that confirms no formalin is detected whereas for proper sensing these change are considerably countable that confirms the detection of formalin. From the sensor sensitivity analysis, owing to add TiO{sub 2}–SiO{sub 2} bilayer with Graphene–MoS{sub 2} Hybrid layer, maximum sensitivity of 85.375% has been numerically resulted. This high sensor performance is for taking advantages of Graphene surface high selectively which detect bio molecular compounds through pi-stacking force, larger work function (5.1 eV) of MoS{sub 2} which allows the high sensitive detection of bio targets and Rich plasmon happens at the TiO{sub 2}–SiO{sub 2} interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single molecule insights into interfacial molecular recognition for model electrochemical DNA biosensors

Electrochemical sensors that use surface-immobilized DNA to bind analytes and transduce the binding into electrochemical signals, have the potential for rapid, specific, and sensitive detection of bioanalytes via a compact and portable platform. However, accessing the structure of these surfaces/interfaces at the relevant spatial scale (< 10 nm), which determines the interfacial interactions and ultimately sensing performance, remains an unsolved challenge. Here, we review studies that have used high resolution atomic force microscope imaging and spatial statistical analysis tools to understand crowding interactions between thiolated DNA probes immobilized on gold electrodes and how such interactions impact target binding. We also review related studies that attempt to control the nanoscale spatial arrangement of the immobilized recognition elements to optimize sensing performance. Furthermore, these efforts have led to new advances in understanding of the structure-function relationships of DNA-based electrochemical biosensors to move the field toward rational engineering of these biosensing interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of the Escherichia coli Phosphonate Binding Protein PhnD and Rationally Optimized Phosphonate Biosensors

The phnD gene of Escherichia coli encodes the periplasmic binding protein of the phosphonate (Pn) uptake and utilization pathway. We have crystallized and determined structures of E. coli PhnD (EcPhnD) in the absence of ligand and in complex with the environmentally abundant 2-aminoethylphosphonate (2AEP). Similar to other bacterial periplasmic binding proteins, 2AEP binds near the center of mass of EcPhnD in a cleft formed between two lobes. Comparison of the open, unliganded structure with the closed 2AEP-bound structure shows that the two lobes pivot around a hinge by {approx}70{sup o} between the two states. Extensive hydrogen bonding and electrostatic interactions stabilize 2AEP, which binds to EcPhnD with low nanomolar affinity. These structures provide insight into Pn uptake by bacteria and facilitated the rational design of high signal-to-noise Pn biosensors based on both coupled small-molecule dyes and autocatalytic fluorescent proteins.

08 HYDROGEN↗

Preparation and characterization of reduced graphene oxide/Fe3O4 nanocomposite by a facile in-situ deposition method for glucose biosensor applications

Highlights: • The rGO/Fe{sub 3}O{sub 4} nanocomposite is successfully prepared by in-situ deposition. • The rGO/Fe{sub 3}O{sub 4} nanocomposite can provide an accelerated electron transfer of GOx. • The rGO/Fe{sub 3}O{sub 4}/GOx/GCE exhibits excellent performance for glucose biosensing. - Abstract: In this work, the reduced graphene oxide-Fe{sub 3}O{sub 4} nanocomposite (rGO/Fe{sub 3}O{sub 4}) was prepared by a facile in-situ deposition of Fe{sub 3}O{sub 4} nanoparticles on graphene sheets. The fact that graphene oxide (GO) was completely reduced to graphene by Fe{sup 2+} was evidenced by X-ray diffractometer, ultraviolet visible spectrophotometer, Fourier transform infrared spectrometer and X-ray photoelectron spectroscopy. The results showed Fe{sub 3}O{sub 4} nanoparticles were generated uniformly and bonded on the surface of rGO with a particle size of about 50 nm. In addition, the rGO/Fe{sub 3}O{sub 4} nanocomposite showed a good conductivity and was considered as a high volume-surface ratio matrix for the immobilization of glucose oxidase (GOx) on a glassy carbon electrode (GCE). The fabricated rGO/Fe{sub 3}O{sub 4}/GOx/GCE exhibited a fast electron transfer and good electrocatalytic activity due to the good electrochemical properties of the rGO/Fe{sub 3}O{sub 4} nanocomposite. These results demonstrated that the rGO/Fe{sub 3}O{sub 4} nanocomposite prepared by in-situ deposition could be applied to high performance biosensor for glucose detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Biosensor libraries harness large classes of binding domains for construction of allosteric transcriptional regulators

Abstract The ability of bacteria to sense specific molecules within their environment and trigger metabolic responses in accordance is an invaluable biotechnological resource. While many transcription factors (TFs) mediating such processes have been studied, only a handful have been leveraged for molecular biology applications. To expand the repertoire of biotechnologically relevant sensors we present a strategy for the construction and testing of chimeric TF libraries, based on the fusion of highly soluble periplasmic binding proteins (PBPs) with DNA-binding domains (DBDs). We validate this concept by constructing and functionally testing two unique sense-and-respond regulators for benzoate, an environmentally and industrially relevant metabolite. This work will enable the development of tailored biosensors for novel synthetic regulatory circuits.

59 BASIC BIOLOGICAL SCIENCES↗

ATP biosensor reveals microbial energetic dynamics and facilitates bioproduction

Adenosine-5’-triphosphate (ATP), the primary energy currency in cellular processes, drives metabolic activities and biosynthesis. Despite its importance, understanding intracellular ATP dynamics’ impact on bioproduction and exploiting it for enhanced bioproduction remains largely unexplored. Here, we harness an ATP biosensor to dissect ATP dynamics across different growth phases and carbon sources in multiple microbial strains. We find transient ATP accumulations during the transition from exponential to stationary growth phases in various conditions, coinciding with fatty acid (FA) and polyhydroxyalkanoate (PHA) production in Escherichia coli and Pseudomonas putida, respectively. We identify carbon sources (acetate for E. coli, oleate for P. putida) that elevate steady-state ATP levels and boost FA and PHA production. Moreover, we employ ATP dynamics as a diagnostic tool to assess metabolic burden, revealing bottlenecks that limit limonene bioproduction. Our results not only elucidate the relationship between ATP dynamics and bioproduction but also showcase its value in enhancing bioproduction in various microbial species.

59 BASIC BIOLOGICAL SCIENCES↗

Self assembled monolayer based liquid crystal biosensor for free cholesterol detection

A unique cholesterol oxidase (ChOx) liquid crystal (LC) biosensor, based on the disruption of orientation in LCs, is developed for cholesterol detection. A self-assembled monolayer (SAM) of Dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP) and (3-Aminopropyl)trimethoxy-silane (APTMS) is prepared on a glass plate by adsorption. The enzyme (ChOx) is immobilized on SAM surface for 12 h before utilizing the film for biosensing purpose. LC based biosensing study is conducted on SAM/ChOx/LC (5CB) cells for cholesterol concentrations ranging from 10 mg/dl to 250 mg/dl. The sensing mechanism has been verified through polarizing optical microscopy, scanning electron microscopy, and spectrometric techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗