Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “binary instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

THE CYCLES OF {alpha} CENTAURI

The main AB pair of the nearby {alpha} Centauri triple system has one of the most extensive X-ray records of any cosmic object, stretching over 30 years. The primary, {alpha} Cen A (G2 V), is a near twin of the Sun, with a similarly soft (1-2 MK) corona. The secondary, {alpha} Cen B (K1 V), is more active than the Sun, with a generally harder coronal spectrum. Here, more than a decade of spatially resolved measurements from ROSAT, XMM-Newton, and Chandra are compared on a common basis, with careful attention to conversion factors that translate count rates of the different instruments into absolute energy fluxes. For the latter purpose, two epochs of Chandra transmission grating spectra, which fully resolve the binary, were modeled using a differential emission measure formalism. The aggregate time series suggests that {alpha} Cen B was near X-ray maximum in the mid-1990s, minimum in the late-1990s, then peaked again in 2004-2005, and more recently has been declining toward another minimum. Meanwhile, {alpha} Cen A showed minimal variability 1995-2000, and like the secondary presently is mired in an activity lull (in fact, as seen by XMM-Newton, the primary 'fainted' from view in the 2005 time frame). Comparisons between X-ray luminosities in the 0.2-2 keV (6-60 A) ROSAT 'WGACAT' band and a softer counterpart 0.06-1.2 keV (10-200 A) reinforce the idea that cycle depth is strongly dependent on the energy span of the measurement, and that much of the coronal luminosity of cool-corona objects like the Sun falls at longer wavelengths than are recorded efficiently by contemporary instruments. Consequently, one must be careful in discussing X-ray cycles, their amplitudes, and coronal heating requirements unless one can demonstrate good control over the out-of-band component.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH ENERGY SPECTRAL EVOLUTION OF V404 CYGNI DURING THE 2015 JUNE OUTBURST AS OBSERVED BY INTEGRAL

The black hole binary GS 2023+338 exhibited an unprecedently bright outburst in 2015 June. On 2015 June 17, the high energy instruments on board INTEGRAL detected an extremely variable emission during both bright and low luminosity phases, with dramatic variations of the hardness ratio on timescales of approximately seconds. The analysis of the IBIS and SPI data reveals the presence of hard spectra in the brightest phases, compatible with thermal Comptonization with a temperature of kT{sub e} ∼ 40 keV. The seed photon’s temperature is best fit by kT{sub 0} ∼ 7 keV, which is too high to be compatible with blackbody emission from the disk. This result is consistent with the seed photons being provided by a different source, which we hypothesize to be a synchrotron driven component in the jet. During the brightest phase of flares, the hardness shows a complex pattern of correlation with flux, with the maximum energy released in the range of 40–100 keV. The hard-X-ray variability for E > 50 keV is correlated with flux variations in the softer band, showing that the overall source variability cannot originate entirely from absorption, but at least part of it is due to the central accreting source.

79 ASTRONOMY AND ASTROPHYSICS↗

Resonance Counters as the Best Tool for the Investigations in Material Science

Sensitivity and resolution play a crucial role when Moessbauer spectroscopy is used in the materials science. Application of resonance counters in Moessbauer spectrometers allows us to increase the parameters mentioned above, and also signal-to-noise ratio considerably. The last one provides diminishing the time needed for obtaining given statistical accuracy. We carried out investigations of development of optimal counters for following isotopes: {sup 57}Fe, {sup 119}Sn, and {sup 151}Eu. Influence of different parameters of resonant radiation converters on experimental results was considered theoretically. Optimization of design has been performed using mathematical modeling based on Monte-Carlo method. Comparison of different types of counters used for resonant detecting was carried out. Results of experimental works on selection of efficient radiation converters are given. Comparison of scintillation and gas resonance counters was carried out. FeAl and FeGe{sub 2} alloys and K{sub 2}MgFe(CN){sub 6} have been used as converters for experiments with {sup 57}Fe-isotope, CaSnO{sub 3} has been used for {sup 119}Sn and Eu{sub 2}O{sub 3} and EuF{sub 3}--for {sup 151}Eu isotope. Gamma-optical scheme for versatile spectrometer, which expands the range of application of resonant detection for other Moessbauer isotopes, was suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation of anti-adhesion surfaces on aluminium substrates of rubber plastic moulds using a coupling method of liquid plasma and electrochemical machining

Hard anti-adhesion surfaces, with low roughness and wear resistance, on aluminium substrates of rubber plastic moulds were fabricated via a new coupling method of liquid plasma and electrochemical machining. With the aid of liquid plasma thermal polishing and electrochemical anodic dissolution, micro/nano-scale binary structures were prepared as the base of the anti-adhesion surfaces. The anti-adhesion behaviours of the resulting aluminium surfaces were analysed by a surface roughness measuring instrument, a scanning electron microscope (SEM), a Fourier-transform infrared spectrophotometer (FTIR), an X-ray diffractometer (XRD), an optical contact angle meter, a digital Vickers micro-hardness (Hv) tester, and electronic universal testing. The results show that, after the liquid plasma and electrochemical machining, micro/nano-scale binary structures composed of micro-scale pits and nano-scale elongated boss structures were present on the sample surfaces. As a result, the anti-adhesion surfaces fabricated by the above coupling method have good anti-adhesion properties, better wear resistance and lower roughness.

36 MATERIALS SCIENCE↗

CHANDRA DETECTION OF EXTENDED X-RAY EMISSION FROM THE RECURRENT NOVA RS OPHIUCHI

Radio, infrared, and optical observations of the 2006 eruption of the symbiotic recurrent nova RS Ophiuchi showed that the explosion produced non-spherical ejecta. Some of this ejected material was in the form of bipolar jets to the east and west of the central source. Here we describe X-ray observations taken with the Chandra X-ray Observatory one and a half years after the beginning of the outburst that reveal narrow, extended structure with a position angle of approximately 300 deg. (east of north). Although the orientation of the extended feature in the X-ray image is consistent with the readout direction of the CCD detector, extensive testing suggests that the feature is not an artifact. Assuming it is not an instrumental effect, the extended X-ray structure shows hot plasma stretching more than 1900 AU from the central binary (taking a distance of 1.6 kpc). The X-ray emission is elongated in the northwest direction-in line with the extended infrared emission and some minor features in the published radio image. It is less consistent with the orientation of the radio jets and the main bipolar optical structure. Most of the photons in the extended X-ray structure have energies of less than 0.8 keV. If the extended X-ray feature was produced when the nova explosion occurred, then its 1.''2 length as of 2007 August implies that it expanded at an average rate of more than 2 mas day{sup -1}, which corresponds to a flow speed of greater than 6000 km s{sup -1} (days/1.6 kpc) in the plane of the sky. This expansion rate is similar to the earliest measured expansion rates for the radio jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating the Multi-epoch Direct Detection Technique to Isolate the Thermal Emission of the Non-transiting Hot Jupiter HD187123b

We report the 6.5σ detection of water from the hot Jupiter HD187123b with a Keplerian orbital velocity K {sub p} of 53 ± 13 km s{sup −1}. This high-confidence detection is made using a multi-epoch, high-resolution, cross-correlation technique, and corresponds to a planetary mass of 1.4{sub −0.3}{sup +0.5} M {sub J} and an orbital inclination of 21° ± 5°. The technique works by treating the planet/star system as a spectroscopic binary and obtaining high signal-to-noise, high-resolution observations at multiple points across the planet’s orbit to constrain the system’s binary dynamical motion. All together, seven epochs of Keck/NIRSPEC L-band observations were obtained, with five before the instrument upgrade and two after. Using high-resolution SCARLET planetary and PHOENIX stellar spectral models, we were able to drastically increase the confidence of the detection by running simulations that could reproduce, and thus remove, the nonrandom structured noise in the final likelihood space well. The ability to predict multi-epoch results will be extremely useful for furthering the technique. Here, we use these simulations to compare three different approaches to combining the cross correlations of high-resolution spectra and find that the Zucker log(L) approach is least affected by unwanted planet/star correlation for our HD187123 data set. Furthermore, we find that the same total signal-to-noise ratio (S/N) spread across an orbit in many, lower S/N epochs rather than fewer, higher S/N epochs could provide a more efficient detection. This work provides a necessary validation of multi-epoch simulations, which can be used to guide future observations and will be key to studying the atmospheres of farther separated, non-transiting exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Phenomenological Implications of Heavy Axion Models

Several models predict the existence of heavy (mass{approx}MeV or so) pseudoscalar (axion-like) particles. This possibility is permitted only if the relation between the axion mass and the Peccei-Quinn constant is relaxed.Here we consider a possible phenomenological consequence of these models. After being produced in the supernova core, these heavy axions would escape and a fraction of them would decay into photons before reaching the earth. We calculated the expected spectrum of these photons from the supernovae SN1987A and CAS A, in terms of the axion mass and the Peccei-Quinn constant f{sub a}, and compared our results to the data from the FERMI Large Area Telescope. The analysis provides strong constraints on the allowed region in the axion parameter space for 100 keV < or approx. m{sub a} < or approx. 1 GeV. This mass region is completely excluded unless f{sub a}>10{sup 112} GeV. For axion masses {approx}100 MeV, the constraint is stronger f{sub a}> a few 10{sup 14} GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Validation of Numerical Simulations of a New-Generation NiTi Endodontic File Under Bending

The superelasticity of NiTi shape memory alloy has been used in endodontics since the 1990s. To study the mechanical behavior of endodontic instruments, a traditional approach consists in experimental investigations. However, finite element analysis constitutes another way to assess their mechanical behavior and to facilitate their design. The main aim of this study is to compare experimental and numerical bending results on different structures (NiTi wire, spreader, and instruments) to estimate the reliability of the finite element simulations. These investigations were carried out as follows. Firstly, experimental material parameters identification was performed using NiTi wires. These parameters were implemented in an appropriate NiTi model. Bending was numerically applied to the meshed structures generated by the finite element method. Experimental tests were performed on real structures under bending, with exactly the same loading, in order to compare experimental and numerical results. These results were in good agreement for each of the considered structures. This enabled the validation of the simulation results and the use of simulations to design new endodontic instruments.

36 MATERIALS SCIENCE↗

Estimating the parameters of nonspinning binary black holes using ground-based gravitational-wave detectors: Statistical errors

We assess the statistical errors in estimating the parameters of nonspinning black hole binaries using ground-based gravitational-wave detectors. While past assessments were based on partial information provided by only the inspiral and/or ring-down pieces of the coalescence signal, the recent progress in analytical and numerical relativity enables us to make more accurate projections using complete inspiral-merger-ring-down waveforms. We employ the Fisher information-matrix formalism to estimate how accurately the source parameters will be measurable using a single interferometric detector as well as a network of interferometers. Those estimates are further vetted by full-fledged Monte Carlo simulations. We find that the parameter accuracies of the complete waveform are, in general, significantly better than those of just the inspiral waveform in the case of binaries with total mass M > or approx. 20M{sub {center_dot}}. In particular, for the case of the Advanced LIGO detector, parameter estimation is the most accurate in the M=100-200M{sub {center_dot}} range. For an M=100M{sub {center_dot}} system, the errors in measuring the total mass and the symmetric mass-ratio are reduced by an order of magnitude or more compared to inspiral waveforms. Furthermore, for binaries located at a fixed luminosity distance d{sub L}, and observed with the Advanced LIGO-Advanced Virgo network, the sky-position error is expected to vary widely across the sky: For M=100M{sub {center_dot}} systems at d{sub L}=1 Gpc, this variation ranges mostly from about a hundredth of a square degree to about a square degree, with an average value of nearly a tenth of a square degree. This is more than 40 times better than the average sky-position accuracy of inspiral waveforms at this mass range. For the mass parameters as well as the sky position, this improvement in accuracy is due partly to the increased signal-to-noise ratio and partly to the information about these parameters harnessed through the post-inspiral phases of the waveform. The error in estimating d{sub L} is dominated by the error in measuring the wave's polarization and is roughly 43% for low-mass (M{approx}20M{sub {center_dot}}) binaries and about 23% for high-mass (M{approx}100M{sub {center_dot}}) binaries located at d{sub L}=1 Gpc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composite gravitational-wave detection of compact binary coalescence

The detection of gravitational waves from compact binaries relies on a computationally burdensome processing of gravitational-wave detector data. The parameter space of compact-binary-coalescence gravitational waves is large and optimal detection strategies often require nearly redundant calculations. Previously, it has been shown that singular value decomposition of search filters removes redundancy. Here we will demonstrate the use of singular value decomposition for a composite detection statistic. This can greatly improve the prospects for a computationally feasible rapid detection scheme across a large compact binary parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTION OF SHARP SYMMETRIC FEATURES IN THE CIRCUMBINARY DISK AROUND AK Sco

The Search for Planets Orbiting Two Stars survey aims to study the formation and distribution of planets in binary systems by detecting and characterizing circumbinary planets and their formation environments through direct imaging. With the SPHERE Extreme Adaptive Optics instrument, a good contrast can be achieved even at small (<300 mas) separations from bright stars, which enables studies of planets and disks in a separation range that was previously inaccessible. Here, we report the discovery of resolved scattered light emission from the circumbinary disk around the well-studied young double star AK Sco, at projected separations in the ∼13–40 AU range. The sharp morphology of the imaged feature is surprising, given the smooth appearance of the disk in its spectral energy distribution. We show that the observed morphology can be represented either as a highly eccentric ring around AK Sco, or as two separate spiral arms in the disk, wound in opposite directions. The relative merits of these interpretations are discussed, as well as whether these features may have been caused by one or several circumbinary planets interacting with the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic Pairs: A DESI Census of Dual and Offset AGN as Precursors to Massive Black Hole Binaries

We present a systematic census of dual and offset active galactic nuclei (AGN) using spectroscopic data from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). After correcting for observational systematics, our final sample contains $>7,000$ dual AGN and 27,000 galaxy pairs containing one AGN over the redshift range $0 \lesssim z \lesssim 3.6$. This sample expands the known dual AGN sample by $\sim 1-2$ orders of magnitude at $0.2 \lesssim z \lesssim 0.4$, includes $\sim 50$ dwarf dual AGN candidates in a regime where only a handful were previously known, and triples the census at $z>2$. Dual AGN are preferentially found at small separations, consistent with merger-driven triggering of AGN activity. The two members of a pair differ in their star formation response: the more massive (primary) host changes little with separation, while the less massive (secondary) lies $\sim 0.3$ dex above matched inactive and one-AGN companions at the same projected separation in main-sequence offset. Using ASTRID simulations, we predict that the fraction of DESI dual AGN whose central black holes will merge by $z \sim 0$ increases with redshift, reaching $\sim 76\%$ by $z \sim 2$, while the fraction producing LISA-detectable mergers peaks at $\sim 37\%$ near $z \sim 0.9$. These results provide the largest uniformly selected spectroscopic sample of kpc-scale dual and offset AGN candidates from a single survey, connecting their host-galaxy and AGN demographics to the progenitor population of massive black hole mergers detectable by LISA.

Dadiani, Ekaterine [Carnegie Mellon U.] (ORCID:000↗

HIGH-PRECISION ORBITAL AND PHYSICAL PARAMETERS OF DOUBLE-LINED SPECTROSCOPIC BINARY STARS-HD78418, HD123999, HD160922, HD200077, AND HD210027

We present high-precision radial velocities (RVs) of double-lined spectroscopic binary stars HD78418, HD123999, HD160922, HD200077, and HD210027. They were obtained based on the high-resolution echelle spectra collected with the Keck I/HIRES, Shane/CAT/Hamspec, and TNG/Sarge telescopes/spectrographs over the years 2003-2008 as part of the TATOOINE search for circumbinary planets. The RVs were computed using our novel iodine cell technique for double-line binary stars, which relies on tomographically disentangled spectra of the components of the binaries. The precision of the RVs is of the order of 1-10 m s{sup -1}, and to properly model such measurements one needs to account for the light-time effect within the binary's orbit, relativistic effects, and RV variations due to tidal distortions of the components of the binaries. With such proper modeling, our RVs combined with the archival visibility measurements from the Palomar Testbed Interferometer (PTI) allow us to derive very precise spectroscopic/astrometric orbital and physical parameters of the binaries. In particular, we derive the masses, the absolute K- and H-band magnitudes, and the parallaxes. The masses together with the absolute magnitudes in the K and H bands enable us to estimate the ages of the binaries. These RVs allow us to obtain some of the most accurate mass determinations of binary stars. The fractional accuracy in msin i only, and hence based on the RVs alone, ranges from 0.02% to 0.42%. When combined with the PTI astrometry, the fractional accuracy in the masses in the three best cases ranges from 0.06% to 0.5%. Among them, the masses of HD210027 components rival in precision the mass determination of the components of the relativistic double pulsar system PSR J0737 - 3039. In the near future, for double-lined eclipsing binary stars we expect to derive masses with a fractional accuracy of the order of up to {approx}0.001% with our technique. This level of precision is an order of magnitude higher than of the most accurate mass determination for a body outside the solar system-the double neutron star system PSR B1913+16.

79 ASTRONOMY AND ASTROPHYSICS↗

ACCRETION FLOW DYNAMICS OF MAXI J1659-152 FROM THE SPECTRAL EVOLUTION STUDY OF ITS 2010 OUTBURST USING THE TCAF SOLUTION

Transient black hole candidates are interesting objects to study in X-rays as these sources show rapid evolutions in their spectral and temporal properties. In this paper, we study the spectral properties of the Galactic transient X-ray binary MAXI J1659-152 during its very first outburst after discovery with the archival data of RXTE Proportional Counter Array instruments. We make a detailed study of the evolution of accretion flow dynamics during its 2010 outburst through spectral analysis using the Chakrabarti–Titarchuk two-component advective flow (TCAF) model as an additive table model in XSPEC. Accretion flow parameters (Keplerian disk and sub-Keplerian halo rates, shock location, and shock strength) are extracted from our spectral fits with TCAF. We studied variations of these fit parameters during the entire outburst as it passed through three spectral classes: hard, hard-intermediate, and soft-intermediate. We compared our TCAF fitted results with standard combined disk blackbody (DBB) and power-law (PL) model fitted results and found that variations of disk rate with DBB flux and halo rate with PL flux are generally similar in nature. There appears to be an absence of the soft state, unlike what is seen in other similar sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolved Imaging of the AR Puppis Circumbinary Disk

Circumbinary disks are common around post-asymptotic giant branch (post-AGB) stars with a stellar companion on orbital timescales of a few 100 to few 1000 days. The presence of a disk is usually inferred from the system’s spectral energy distribution and confirmed, for a sub-sample, by interferometric observations. We used the Spectro-Polarimetric High-contrast Exoplanet REsearch (SPHERE) instrument on the Very Large Telescope to obtain extreme adaptive optics assisted scattered light images of the post-AGB binary system AR Puppis. Data have been obtained in the V, I, and H bands. Our observations have produced the first resolved images of AR Puppis’s circumbinary disk and confirm its edge-on orientation. In our high-angular-resolution and high-dynamic-range images we identify several structural components such as a dark mid-plane, the disk surface, and arc-like features. We discuss the nature of these components and use complementary photometric monitoring to relate them to the orbital phase of the binary system. Because the star is completely obscured by the disk at visible wavelengths, we conclude that the long-term photometric variability of the system must be caused by variable scattering, not extinction, of starlight by the disk over the binary orbit. Finally, we discuss how the short disk lifetimes and fast evolution of the host stars compared to the ages at which protoplanetary disks are typically observed make systems like AR Puppis valuable extreme laboratories to study circumstellar disk evolution and constrain the timescale of dust grain growth during the planet formation process.

79 ASTRONOMY AND ASTROPHYSICS↗

GSC 07396-00759 = V4046 Sgr C[D]: A WIDE-SEPARATION COMPANION TO THE CLOSE T TAURI BINARY SYSTEM V4046 Sgr AB

We explore the possibility that GSC 07396-00759 (spectral type M1e) is a widely separated ({approx}2.'82, or projected separation {approx}12,350 AU) companion to the 'old' (age {approx}12 Myr) classical T Tauri binary system V4046 Sgr AB, as suggested by the proximity and similar space motions of the two systems. If the two systems are equidistant and coeval, then GSC 07396-00759, like V4046 Sgr AB, must be a spectroscopic binary with nearly equal-mass components, and V4046 Sgr must be at least {approx}8 Myr old. Analysis of a serendipitous Chandra X-ray grating spectrum and light curve as well as XMM-Newton light curves and CCD spectra of GSC 07396-00759 obtained during long exposures targeting V4046 Sgr AB reveals a relatively hard (T{sub X} {approx} 10{sup 7} K) X-ray spectrum, strong flaring, and relatively low-density plasma. These X-ray characteristics of GCS 07396-00759 are indicative of a high level of coronal activity, consistent with its apparent weak-lined T Tauri star status. Interactions between V4046 Sgr AB and GCS 07396-00759 when the two systems were more closely bound may be responsible for (1) their dissolution {approx}10{sup 6} yr ago, (2) the present tight, circular orbit of V4046 Sgr AB, and (3) the persistence of the gaseous circumbinary disk still orbiting V4046 Sgr AB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STELLAR CORONAE, SOLAR FLARES: A DETAILED COMPARISON OF {sigma} GEM, HR 1099, AND THE SUN IN HIGH-RESOLUTION X-RAYS

The Chandra High Energy Transmission Grating Spectrometer (HETG) spectra of the coronally active binary stars {sigma} Gem and HR 1099 are among the highest fluence observations for such systems taken at high spectral resolution in X-rays with this instrument. This allows us to compare their properties in detail to solar flare spectra obtained with the Russian CORONAS-F spacecraft's RESIK instrument at similar resolution in an overlapping bandpass. Here we emphasize the detailed comparisons of the 3.3-6.1 A region (including emission from highly ionized S, Si, Ar, and K) from solar flare spectra to the corresponding {sigma} Gem and HR 1099 spectra. We also model the larger wavelength range of the HETG, from 1.7 to 25 A - having emission lines from Fe, Ca, Ar, Si, Al, Mg, Ne, O, and N-to determine coronal temperatures and abundances. {sigma} Gem is a single-lined coronally active long-period binary which has a very hot corona. HR 1099 is a similar, but shorter period, double-lined system. With very deep HETG exposures we can even study emission from some of the weaker species, such as K, Na, and Al, which are important since they have the lowest first ionization potentials, a parameter well known to be correlated with elemental fractionation in the solar corona. The solar flare temperatures reach Almost-Equal-To 20 MK, comparable to the {sigma} Gem and HR 1099 coronae. During the Chandra exposures, {sigma} Gem was slowly decaying from a flare and its spectrum is well characterized by a collisional ionization equilibrium plasma with a broad temperature distribution ranging from 2 to 60 MK, peaking near 25 MK, but with substantial emission from 50 MK plasma. We have detected K XVIII and Na XI emission which allow us to set limits on their abundances. HR 1099 was also quite variable in X-rays, also in a flare state, but had no detectable K XVIII. These measurements provide new comparisons of solar and stellar coronal abundances, especially at the lowest first ionization potential (FIP) values. The low FIP elements do not show enhancement in the stellar coronae as they do in the Sun, except perhaps for K in {sigma} Gem. While {sigma} Gem and HR 1099 differ in their emission measure distributions, they have very similar elemental abundances.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗