Beryllium thin films for resistor applications

Beryllium thin films have a protective oxidation resistant property at high temperature and high recrystallization temperature. However, the experimental film has very low temperature coefficient of resistance.

Fiet, O.↗

Manufacture, assembly, and delivery of beryllium test panels

Details of the fabrication and assembly of two 99 cm by 99 cm (39 in. by 39 in.) beryllium heat shield test panels are presented. Each panel consists of two hat-stiffened, formed skins which overlap a transverse slip joint at the center of the panel; clips join the two skins at the slip joint, and continuous standoffs are provided at the ends of the panel. The hat-stiffeners are joined to the skin by furnace-brazing, using the braze alloy BAg 18. The parts are generally 0.051 cm (0.020 in.) thick. Tools used to form the detail parts are shown, together with the results of preliminary forming and brazing trials to verify processing techniques. Problems encountered in the manufacture of the panels are discussed.

Source record↗

Notched strength of beryllium powder and ingot sheets.

The effects of notches in thin beryllium sheets were studied as functions of material variables and notch severity. Double edge notched samples having stress concentration factors of 1.0 to 15.4 were prepared by milling to size, etching, and electrical discharge machining the notches. Strength was not reduced greatly by sharp notches, and duller notches were more deleterious than sharp notches. The trend was for reduced strength for dull notches, increased strength for sharper notches, and reduced strength for very sharp notches. Differences in material purity or source of the sheet had little affect on notch sensitivity. The most important factors appear to be oxide content and directionality of the sheet microstructure; high oxide content and highly directional microstructure tend to give more notch sensitivity than low oxide content, and more bidirectional microstructure. Postulated causes of the change in notched/unnotched strength are given.

Moss, R. G.↗

A study of the properties of beryllium doped silicon with particular emphasis on diffusion mechanisms: Profiles of depth dependent conductivity as determined by electrical surface probes

Very large diffusion coefficients were encountered and required the determination of impurity profiles for samples approximately 1 cm thick. Since conductivity values are readily converted into concentrations of electrically active impurities, the major problem became that of accurately determining the conductivity profiles of beryllium diffused silicon samples. Four-point probe measurements on samples having depth conductivities are interpreted in terms of conductivity profiles, based on an exact solution of the problem of exponentially depth dependent conductivity. Applications include surface conductivity determination where the form of the conductivity profile is known, and conductivity profile determination from probe measurements taken as the sample surface is progressively lapped away. The application is limited to samples having conductivity monotonically decreasing with depth from the probed surface.

Franks, R. K.↗

Test fixture design for boron-aluminum and beryllium test panels

A detailed description of the test fixture design and the backup analysis of the fixture assembly and its components are presented. The test fixture is required for the separate testing of two boron-aluminum and two beryllium compression panels. This report is presented in conjunction with a complete set of design drawings on the test fixture system.

Breaux, C. G.↗

Cleaning and activation of beryllium-copper electron multiplier dynodes.

Description of a cleaning and activation procedure followed in preparing beryllium-copper dynodes for electron multipliers used in sounding-rocket experiments to detect auroral electrons. The initial degreasing step involved a 5-min bath in trichloroethylene in an ultrasonic cleaner. This was followed by an ultrasonic rinse in methanol and by a two-step acid pickling treatment to remove the oxides. Additional rinsing in water and methanol was followed by activation in a stainless-steel RF induction oven.

Pongratz, M. B.↗

Crack toughness evaluation of hot pressed and forged beryllium.

Fracture toughness tests at room temperature were made on three-point loaded beryllium bend specimens cut from hot pressed block and a forged disk. These specimens had plane proportions conforming to ASTM E 399 and covered a thickness range of from 1/32 to 1/2 in. Two sets of bend specimens were tested, one having fatigue cracks and the other 0.5 mil radius notches. One objective of the investigation was the development of techniques to produce fatigue cracks in accordance with the procedures specified in ASTM E 399. This objective was achieved for the hot pressed material. In plane cracks were not consistently produced in the specimens cut from forged stock.

Jones, M. H.↗

Fracture in hexagonal closed packed metals, zinc and beryllium

It is shown that fracture in zinc and beryllium is nucleation controlled and is independent of the nature of the barrier from which fracture nucleates. The double cantilever cleavage technique was used to determine the energy required to propagate a crack on the basal plane (0001) in single crystals. Tensile fracture data from single and asymmetric bicrystals were used to calculate the energy needed to initiate a cleavage crack on the (0001) plane.

Kamdar, M. H.↗

A non-LTE treatment of beryllium lines - Misidentification of the solar Be I feature at 2650 A

The formation of beryllium lines, with particular reference to the solar Be spectrum, is investigated in a non-LTE context with a 25-level model atom in which 15 levels are allowed to depart from LTE. In some transitions, particularly the Be I 2650-A line, the non-LTE effects can be quite dramatic, changing the deduced abundances by a factor of 4. Based on the non-LTE calculations and Copernicus observations of other stars, it is found that a solar spectral feature at 2650 A, previously identified by numerous investigators as a Be I line, cannot be produced by Be I. Non-LTE effects on the Be II 3131-A line, used for most Be abundance determinations in the literature, are small by comparison.

Shipman, H. L.↗

Linear absorption coefficient of beryllium in the 50-300-A wavelength range

Transmittances of thin-film filters fabricated for an extreme-UV astronomy sounding-rocket experiment yield values for the linear absorption coefficient of beryllium in the 50-300-A wavelength range, in which previous measurements are sparse. The inferred values are consistent with the lowest data previously published and may have important consequences for extreme-UV astronomers.

Barstow, M. A.↗

Beryllium-10 contents of core samples from the St. Severin meteorite

Beryllium-10 contents in the 20-28 dpm/kg range, averaging 24.5 + or - 0.9 dpm/kg, have been obtained for 11 samples taken from along the 35-cm core AIII of the St. Severin LL chondrite. Be-10 content increases with depth in the outermost 8 cm, and there is little change in content at greater depths. Significant disagreement is noted between the measured values and the results of calculations based on the cross sections for proton-induced Be-generating reactions. Cosmogenic Be-10 in stony meteorites is better described as a medium-energy product than a high energy one.

Tuniz, C.↗

Cryogenic infrared imaging beryllium telescope for Infrared Astronomical Satellite (IRAS)

The IRAS mission is the result of an international project involving the cooperation of the U.S., the United Kingdom, and the Netherlands. The Infrared Astronmical Satellite was placed into orbit on January 25, 1983. Its main function is to provide a survey of the entire sky as viewed in four octaves of infrared radiation in the wavelenth region from 8 to 120 microns. The cylindrical structure of the satellite contains a large dewar vessel with 70 liters of superfluid helium. The helium has the function to maintain the contents of the vessel at 2.5 K for the duration of the mission. The IRAS optics is a Ritchey-Chretien telescope of 24 inches aperture. Because of the operational requirements of the mission, it had been specified that all optical components should be beryllium. Attention is given to the cold performance test conducted with IRAS, plans for future infrared telescopes, and reflectance limits.

Devereux, W. P.↗

Cryogenic optical tests of a lightweight HIP beryllium mirror

Five interferometric tests were conducted at cryogenic temperatures on a lightweight, 50 cm diameter, hot isostatic pressed (HIP) beryllium mirror in the Ames Research Center (ARC) Cryogenic Optics Test Facility. The purpose of the tests was to determine the stability of the mirror's figure when cooled to cryogenic temperatures. Test temperatures ranged from room ambient to 8 K. One cycle to 8 K and five cycles to 80 K were performed. Optical and thermal test methods are described. Data is presented to show the amount of cryogenic distortion and hysteresis present in the mirror when measured with an earlier, Shack interferometer, and with a newly-acquired, phase-measuring interferometer.

Melugin, Ramsey K.↗

Solar flare X-ray polarimeter utilizing a large area thin beryllium scattering disk

A model of a solar flare X-ray polarimeter utilizing a large-area thin beryllium scattering disk was developed using Monte Carlo techniques for several classes of solar flares. The solar-flare polarimeter consists of a 30-cm-diam Be disk of about 1/3 of a scattering length thickness, which is surrounded by a cylindrical detector composed of six segmented panels of NaI scintillators, each coupled to 15 photomultiplier tubes. The instrument is sensitive to X-rays from 10 to 100 keV. For a class-M-2 solar flare observed for 10 sec from a balloon at an altitude of 150,000 ft, the minimum detectable polarization at the 99 percent statistical confidence level was found to be 1-6 percent over the energy range 20-100 keV.

Gotthelf, E.↗