At least 145 records · Page 8

Free-standing ultrathin lithium metal–graphene oxide host foils with controllable thickness for lithium batteries

Thin (≤20 μm) and free-standing Li metal foils would enable precise prelithiation of anode materials and high-energy-density Li batteries. Existing Li metal foils are too thick (typically 50 to 750 μm) or too mechanically fragile for these applications. Here, we developed a facile and scalable process for the synthesis of an ultrathin (0.5 to 20 μm), free-standing and mechanically robust Li metal foil within a graphene oxide host. In addition to low areal capacities of ~0.1 to 3.7 mAh cm –2 , this Li foil also has a much-improved mechanical strength over conventional pure Li metal foil. Our Li foil can improve the initial Coulombic efficiency of graphite (93%) and silicon (79.4%) anodes to around 100% without generating excessive Li residue, and increases the capacity of Li-ion full cells by 8%. In conclusion, the cycle life of Li metal full cells is prolonged by nine times using this thin Li composite anode.

25 ENERGY STORAGE↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Power subsystem performance prediction /PSPP/ computer program.

A computer program which simulates the operation of the Viking Orbiter Power Subsystem has been developed. The program simulates the characteristics and interactions of a solar array, battery, battery charge controls, zener diodes, power conditioning equipment, and the battery spacecraft and zener diode-spacecraft thermal interfaces. This program has been used to examine the operation of the Orbiter power subsystem during critical phases of the Viking mission - from launch, through midcourse maneuvers, Mars orbital insertion, orbital trims, Lander separation, solar occultations and unattended operation - until the end of the mission. A typical computer run for the first 24 hours after launch is presented which shows the variations in solar array, zener diode, battery charger, batteries and user load characteristics during this period.

Weiner, H.↗

Controlling fires in silver/zinc batteries

Silver/zinc storage battery fires are often difficult to extinguish. Improved technique employs manifold connected to central evacuation chamber to rapidly vent combustion-supporting gases generated by battery plate oxides.

Boshers, W. A.↗

Stress characterization for friction-stir-welded electric vehicle battery trays with application of neutron diffraction

The battery tray is an essential component that protects and controls battery-cell temperatures in electric and plug-in hybrid vehicles. The functional stress limit of the battery tray heavily depends on the residual stress acquired from the manufacturing process. Consequently, exceeding the stress limit of the battery tray during operation could compromise the battery-cell banks and may risk the vehicle's safety. Hence, understanding residual stress formation is vital for design and safety concerns. Here, in the current study, AA 6061-plates were friction stir welded to an A365 high-pressure die-cast battery tray to create sealed coolant channels in the battery tray. However, this multi-material lap friction stir weld introduces residual stress into the battery tray, resulting in distortion. This distortion was mitigated using burnishing or coining operations, though straightening the battery tray had initially unknown effects on the residual stress. Therefore, neutron diffraction was utilized to characterize residual stresses after straightening. The results indicate that the friction stir welding (FSW) operation generated residual stresses exceeding the yield strength of the material, consequently deforming the battery tray by ±3 mm from the pre-weld geometry. The burnishing operation reduced the residual stresses below the material's yield strength while restoring the tray to within ±0.75 mm of the pre-weld geometry. Similarly, the coining operation restored the battery tray to within ±0.75 mm of the pre-weld geometry, however, increasing the number of locations where the residual stress exceeds the yield strength of the material.

36 MATERIALS SCIENCE↗

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

Cycle life characteristics of sealed silver-zinc cell with inorganic separator

Two batteries containing 18 cells have been cycling in a simulated synchronous (24-hour) orbit for over a year at 40% depth of discharge at 22 C. One battery is under individual cell monitoring and control and the other battery is controlled at the battery level. The battery with individual cell monitoring and protection has performed over 350 cycles with no sign of failure. The battery without individual cell protection failed at 270 cycles from failure to remain above the specified minimum discharge voltage. A significant conclusion is that the sealed Ag-Zn cells manufactured with the inorganic separator material have demonstrated their capability to cycle at a fairly high depth of discharge and are worthy of consideration in short life synchronous orbit applications.

Lear, J. W.↗

LST power system long life design techniques

The LST mission of up to 15 years plus about two years allotment for ground return maintenance could stretch the LST operation to the end of the century. This extended mission life, combined with the large power requirements of the telescope and the scientific instruments, imposes stringent requirements on the electrical power subsystem. The use of an onboard microprocessor for individual battery cell control and monitoring offers a technique that could improve the battery cycle life dramatically. The battery configuration includes spare battery cells which can be switched by the microprocessor to replace failed cells. The microprocessor can also be used for inflight reconditioning of the batteries to increase performance and verify ampere-hour capacity. The Flexible Roll-Up Solar Array (FRUSA) system offers a solar array at an acceptable cost that can stay within weight and volume constraints.

Smith, O. B.↗

STS-96 Mission Highlights

In this second part of a three-part video mission-highlights set, on-orbit spacecrew activities performed on the STS-96 Space Shuttle Orbiter Discovery and the International Space Station are reviewed. The flight crew consists of Kent V. Rominger, Commander; Rick D. Husband, Pilot; and Mission Specialists Ellen Ochoa, Tamara E. Jernigan, Daniel T. Barry, Julie Payette (Canadian), and Valery Ivanovich Tokarev (Russian). The primary goals of this mission were to work on logistics and resupply the International Space Station. This second part in the mission series features video from Flight Day 4-7 (FD 4-7). FD 4 of STS-96 presents astronauts Tammy Jernigan and Dan Barry completing the second longest space walk in shuttle history. Footage includes Jernigan and Barry transferring and installing two cranes from the shuttle's payload bay to locations on the outside of the station. The astronauts enter the International Space Station delivering supplies and prepare the outpost to receive its first resident crew, scheduled to arrive in early 2000 on FD 5. The video also captures the crew involved in logistics transfer activities within the Discovery/ISS orbiting complex. FD 6 includes footage of Valery Tokarev and Canadian astronaut Julie Payette charging out the final six battery recharge controller units for two of Zarya's power-producing batteries and all crew members' involvement in logistics transfer activities from the SPACEHAB module to designated locations in the International Space Station. With the transfer work of FD 6 all but complete, the astronauts conduct some additional work, installing parts of a wireless strain gauge system that will help engineers track the effects of adding modules to the station throughout its assembly. Moving the few remaining items from Discovery to the ISS, then closing a series of hatches within the station's modules leading back to the shuttle are the primary activities contained in FD 7. Final coverage features Discovery's astronauts finishing their work inside the International Space Station, closing all of the hatches and readying the shuttle's small thrusters to be fired to raise the entire complex's orbit in preparation for the undocking and departure set for FD 8.

Source record↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Design description of the Tangaye Village photovoltaic power system

The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

Martz, J. E.↗

Control-Oriented Modeling of Lithium-Ion Batteries

Battery management systems (BMSs), which monitor and optimize performance while ensuring safety, require control-oriented models, i.e., models tailored to the design and implementation of estimation and control algorithms. Physics-based electrochemical models describe detailed battery phenomena, but are too computationally intensive for use in estimation and control applications. Single particle models (SPMs), which retain some of the physics of electrochemical models, are often used for control-oriented battery modeling since they are computationally efficient; however, they are only valid over very low frequency ranges and C-rates. Empirical equivalent circuit models (ECMs) are also used for control-oriented battery modeling since they are computationally efficient and can describe battery behavior over wide frequency ranges; however, they provide no physical understanding of the battery and, therefore, have limited applicability. Further, fractional order terms (e.g., Warburg impedances) are often employed, making the models unwieldy for use in the time domain. This work provides a control-oriented battery model that combines the benefits of SPM and ECM models, while overcoming their limitations. The proposed model incorporates some of the battery physics found in electrochemical models, can easily be used in both the time and frequency domains, and describes battery behavior over its entire frequency range. A linearized single particle model, which incorporates key electrochemical parameters, is used for modeling battery physics at very low frequencies. For low frequencies, integer-order linear systems are used to approximate diffusion physics described by Warburg impedances, and high frequency behavior is modeled by the double layer capacitance effect. The proposed battery model is more computationally efficient than full electrochemical models since it does not require the solution of PDEs, is accurate for a wider frequency range than the SPM considered in this paper, and does not suffer from the unwieldiness and limited applicability of empirical ECMs. Finally, the model is validated in the time and frequency domains via a comparison to pseudo-two-dimensional (P2D) model simulations and experimental data.

25 ENERGY STORAGE↗

Results from the testing and analysis of LDEF batteries

Batteries were used on the Long Duration Exposure Facility (LDEF) to provide power to both the active experiments and the experiment support equipment such as the Experiment Initiative System, Experiment Power and Data System (data acquisition system), and the Environment Exposure Control Canisters. Three different types of batteries were used: lithium sulfur dioxide (LiSO2), lithium carbon monofluoride (LiCF), and nickel cadmium (NiCd). A total of 92 LiSO2, 10 LiCF, and 1 NiCd batteries were flown on the LDEF. In addition, approximately 20 LiSO2 batteries were kept in cold storage at NASA LaRC. The various investigations and post-flight analyses of the flight and control batteries are reviewed. The primary objectives of these studies was to identify degradation modes (if any) of the batteries and to provide information useful to future spacecraft missions. Systems SIG involvement in the post-flight evaluation of LDEF batteries was two-fold: (1) to fund SAFT (original manufacturer of the LiSO2 batteries) to perform characterization of 13 LiSO2 batteries (10 flight and 3 control batteries); and (2) to integrate investigator results.

Spear, Steve↗

Use of COTS Batteries on ISS and Shuttle

This presentation focuses on COTS Battery testing for energy content, toxicity, hazards, failures modes and controls for different battery chemistries. It also discusses the current program requirements, challenges with COTS Batteries in manned vehicle COTS methodology, JSC test details, and gives a list of incidents from consumer protection safety commissions. The Battery test process involved testing new batteries for engineering certification, qualification of batteries, flight acceptance, cell and battery, environment, performance and abuse. Their conclusions and recommendations were that: high risk is undertaken with the use of COTS batteries, hazard control verification is required to allow the use of these batteries on manned space flights, failures during use cannot be understood if different scenarios of failure are not tested on the ground, and that testing is performed on small sample numbers due to restrictions on cost and time. They recommend testing of large sample size to gain more confidence in the operation of the hazard controls.

Jeevarajan, Judith A.↗

A nickel-cadmium battery reconditioning circuit

The circuit presented is simple and small enough to be included in a typical battery charge/power control assembly, yet provides the advantage of a complete ground-type battery reconditioning discharge. Test results on the circuit when used to recondition two 24 cell, 20 A-h nickel-cadmium batteries are given. These results show that a battery reconditioned with this circuit returns to greater than 90 percent of its original capacity (greater than nameplate capacity) and follows a typical new battery degradation curve even after over 20,000 simulated orbital cycles for a 4 year period. Applications of the circuit are considered along with recommendations relative to its use. Its application in low voltage (22 to 36 Vdc) power systems and in high voltage (100 to 150 Vdc) power systems is discussed. The implications are that the high voltage systems have a greater need for battery reconditioning than their low voltage counterparts, and that using these circuit techniques, the expected life of a battery in low Earth orbit can be up to 5 years.