Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “avalanche diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

III-V alloy heterostructure high speed avalanche photodiodes

Heterostructure avalanche photodiodes have been successfully fabricated in several III-V alloy systems: GaAlAs/GaAs, GaAlSb/GaAlSb, and InGaAsP/InP. These diodes cover optical wavelengths from 0.4 to 1.8 micron. Early stages of development show very encouraging results. High speed response of less than 35 ps and high quantum efficiency more than 95 percent have been obtained. The dark currents and the excess avalanche noise are also dicussed. A direct comparison of GaAlSb, GaAlAsSb, and In GaAsP avalanche photodiodes is given.

Law, H. D.↗

Lunar observer laser altimeter

Understanding the global topography of the Moon is especially important for answering questions concerning lunar origin and evolution. Many outstanding problems in lunar science can be addressed with high resolution topographic data. The severe power, mass, size, and data-rate limitations imposed by the Lunar Geoscience Observer (LGO) and other Observer-class missions are major challenges for all instruments capable of measuring topography. A radar altimeter that meets these strict requirements could obtain a global prespective of lunar topography with a few kilometers spatial resolution and 10 m vertical resolution from a lunar orbit of 100 km. A prototype model is being constructed of the Lunar Observer Laser Altimeter (LOLA) capable of continuously measuring the range to the lunar surface with sub-meter vertical resolution within a 30 to 300 m diameter surface footprint. This same instrument is also designed to provide a direct measure of the surface height distribution in the footprint by waveform analysis of the backscattered laser pulse. Both these measurements are to be made in a continuous, nadir profile across the lunar surface from a 100 km orbit. The wavelength of the altimeter is 1064 nm. A short-pulse (2 nsec), diode-pumped Nd:YAG laser combined with a 25 cm diameter telescope, silicon avalanche photodiode detector, ranging electronics, and instrument computer was designed to make these measurements and meet all the requirements of the LGO mission.

Bufton, J. L.↗

Video Guidance Sensor System with Laser Rangefinder

A video guidance sensor system for use in automated docking of a chase vehicle with a target vehicle wherein the chase. vehicle includes a laser rangefinder that uses pulse or phase time of flight measurement to measure distance. The laser rangefinder includes a diode laser pulse or phase driver that produces an output signal to a timing element and simultaneously operates a laser diode. The laser diode produces an intense light beam of a predetermined wavelength which is directed to retroreflectors that are positioned on a passive target. The laser rangefinder includes an avalanche photodetector that produces a corresponding output signal when detecting light reflected from the retroreflectors. The timing element measures a time interval between the output of the laser diode and the detection of light and supplies a corresponding output signal to a computer in order to determine the range of the target vehicle relative to the chase vehicle.

Richard T Howard↗

Optical communication with semiconductor laser diode

This interim report describes the progress in the construction of a 220 Mbps Q=4 PPM optical communication system that uses a semiconductor laser as the optical transmitter and an avalanche photodiode (APD) as the photodetector. The transmitter electronics have been completed and contain both GaAs and ECL III IC's. The circuit was able to operate at a source binary data rate from 75 Mbps to 290 Mbps with pulse rise and fall times of 400 ps. The pulse shapes of the laser diode and the response from the APD/preamplifier module were also measured.

Davidson, Frederic↗

Direct detection optical intersatellite link at 220 Mbps using AlGaAs laser diode and silicon APD with 4-ary PPM signaling

A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the preamplifier high frequency response.

Sun, Xiaoli↗

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implanted Guard Ring Edge Termination With Avalanche Capability for Vertical GaN Devices

Edge termination is the key building block in power devices to enable near-ideal, avalanche breakdown voltage (BV). Here, this work presents the design, fabrication, and physics of a GaN guard ring (GR) edge termination formed by selective-area nitrogen implantation through an epitaxial p-GaN layer. The fabrication of this termination only includes a single implantation step that does not require precise control of implant depth, rendering a large process latitude. The selective-area implantation produces p-GaN rings that are separated by the implanted, semi-insulating regions. The number and spacing of the p-type rings are found to determine the BV of the vertical GaN p-n diode. The 16-ring structure enables a BV of 1800 V, being 88% of the theoretical 1-D parallel-plane limit. Avalanche characteristics are observed in devices with a large variety of GR designs. Finally, we present a comprehensive survey on the efficiency, fabrication complexity, real estate, and avalanche capability of various edge termination techniques that have been reported in vertical GaN devices. The high efficiency (among the highest reported in avalanche-capable GaN terminations), simple and robust fabrication process, and uniform avalanche capability make this implanted GR a promising edge termination for high-voltage GaN devices.

42 ENGINEERING↗

Design Considerations for Heavily-Doped Cryogenic Schottky Diode Varactor Multipliers

Diode modeling for Schottky varactor frequency multipliers above 500 GHz is presented with special emphasis placed on simple models and fitted equations for rapid circuit design. Temperature- and doping-dependent mobility, resistivity, and avalanche current multiplication and breakdown are presented. Next is a discussion of static junction current, including the effects of tunneling as well as thermionic emission. These results have been compared to detailed measurements made down to 80 K on diodes fabricated at JPL, followed by a discussion of the effect on multiplier efficiency. Finally, a simple model of current saturation in the undepleted active layer suitable for inclusion in harmonic balance simulators is derived.

Schlecht, E.↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gallium nitride electromagnetic pulse arrestor

A GaN diode EMP arrestor exhibits breakdown in <10 ns at reverse-bias voltage >20 kV. Additionally, the arrestor exhibits avalanche ruggedness at 1 kA/cm 2 in a 1 mm 2 device (i.e. 10 A absolute current) over a period of 500 ns following the onset of breakdown. Finally, the specific on-resistance in the forward direction is <20 mΩ cm 2 .

Kaplar, Robert↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Implementation and Assessment of Advanced Analog Vector-Matrix Processor

This paper discusses the design and implementation of an analog optical vecto-rmatrix coprocessor with a throughput of 128 Mops for a personal computer. Vector matrix calculations are inherently parallel, providing a promising domain for the use of optical calculators. However, to date, digital optical systems have proven too cumbersome to replace electronics, and analog processors have not demonstrated sufficient accuracy in large scale systems. The goal of the work described in this paper is to demonstrate a viable optical coprocessor for linear operations. The analog optical processor presented has been integrated with a personal computer to provide full functionality and is the first demonstration of an optical linear algebra processor with a throughput greater than 100 Mops. The optical vector matrix processor consists of a laser diode source, an acoustooptical modulator array to input the vector information, a liquid crystal spatial light modulator to input the matrix information, an avalanche photodiode array to read out the result vector of the vector matrix multiplication, as well as transport optics and the electronics necessary to drive the optical modulators and interface to the computer. The intent of this research is to provide a low cost, highly energy efficient coprocessor for linear operations. Measurements of the analog accuracy of the processor performing 128 Mops are presented along with an assessment of the implications for future systems. A range of noise sources, including cross-talk, source amplitude fluctuations, shot noise at the detector, and non-linearities of the optoelectronic components are measured and compared to determine the most significant source of error. The possibilities for reducing these sources of error are discussed. Also, the total error is compared with that expected from a statistical analysis of the individual components and their relation to the vector-matrix operation. The sufficiency of the measured accuracy of the processor is compared with that required for a range of typical problems. Calculations resolving alloy concentrations from spectral plume data of rocket engines are implemented on the optical processor, demonstrating its sufficiency for this problem. We also show how this technology can be easily extended to a 100 x 100 10 MHz (200 Cops) processor.

Gary, Charles K.↗

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

Avalanche Photodiode Statistics in Triggered-avalanche Detection Mode

The output of a triggered avalanche mode avalanche photodiode is modeled as Poisson distributed primary avalanche events plus conditionally Poisson distributed trapped carrier induced secondary events. The moment generating function as well as the mean and variance of the diode output statistics are derived. The dispersion of the output statistics is shown to always exceed that of the Poisson distribution. Several examples are considered in detail.

Tan, H. H.↗

6 um Pulsed OP-GaAs OPO Laser for Unambiguous Water Ice Detection on the Moon and Other Planetary Bodies

NASA demands a laser transmitter for planetary remote sensing to detect water-ice on the Moon and other planetary bodies. Based on the measurement of the Moon Mineralogy Mapper (M3) instrument, the discovery of water ice on the Moon was acclaimed, but the measurement is disputed because OH- and/or H2O-bearing materials share the absorption line around 3 μm wavelength. Lunar Flashlight, another mission project exploring the surface of Moon which will be launched later this year, enables to map the minerals on dark area of the Moon, but could not resolve the above-mentioned ambiguity. The absorption of 6.08 μm light is uniquely associated with the bending resonance of H2O since there is no comparable vibration in confounding OH-bearing materials. 6.08 μm laser between the atmospheric windows: middle-wave infrared (3-5 μm) and long-wave infrared (8-12 μm) has not been commercially available. Our approach is a Q-switched Ho:YLF laser pumped the orientation-pattern Gallium Arsenide optical parametric oscillator (OP-GaAs OPO) for generating high-energy laser pulses at the wavelength of 6.08 μm. In the current design, a 1.94 μm Tm:fiber is used as the pump source. In the compact design, a 1.94 μm laser diode will replace the Tm:fiber laser as the pump source. We will combine this proposed mid-infrared laser with the latest HgCdTe avalanche photodiode (APD) array to design a lidar for detecting water ice on the Moon and Mars from their respective orbits, enabling novel science and in-situ resource utilization. Our instrument is an enabling technology aboard the Artemis program and others.

mid-infrared laser↗

Evaluation of a satellite laser ranging technique using pseudonoise code modulated laser diodes

Several types of Satellite Laser Ranging systems exist, operating with pulsed, high-energy lasers. The distance between a ground point and an orbiting satellite can be determined to within a few centimeters. A new technique substitutes pseudonoise code modulated laser diodes, which are much more compact, reliable and less costly, for the lasers now used. Since laser diode technology is only now achieving sufficiently powerful lasers, the capabilities of the new technique are investigated. Also examined are the effects of using an avalanche photodiode detector instead of a photomultiplier tube. The influence of noise terms (including background radiation, detector dark and thermal noise and speckle) that limit the system range and performance is evaluated.

Ball, Carolyn Kay↗

The Mars Observer laser altimeter investigation

The primary objective of the Mars Observer laser altimeter (MOLA) investigation is to determine globally the topography of Mars at a level suitable for addressing problems in geology and geophysics. Secondary objectives are to characterize the 1064-nm wavelength surface reflectivity of Mars to contribute to analyses of global surface mineralogy and seasonal albedo changes, to assist in addressing problems in atmospheric circulation, and to provide geodetic control and topographic context for the assessment of possible future Mars landing sites. The principal components of MOLA are a diode-pumped, neodymium-doped yttrium aluminum garnet laser transmitter that emits 1064-nm wavelength laser pulses, a 0.5-m-diameter telescope, a silicon avalanche photodiode detector, and a time interval unit with 10-ns resolution. MOLA will provide measurements of the topography of Mars within approximately 160-m footprints and a center-to-center along-track foot print spacing of 300 m along the Mars Observer subspacecraft ground track. The elevation measurements will be quantized with 1.5 m vertical resolution before correction for orbit- and pointing induced errors. MOLA profiles will be assembled into a global 0.2 deg x 0.2 deg grid that will be referenced to Mars' center of mass with an absolute accuracy of approximately 30 m. Other data products will include a global grid of topographic gradients, corrected individual profiles, and a global 0.2 deg x 0.2 deg grid of 1064-nm surface reflectivity.

Zuber, M. T.↗