Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Phase identification using co‐association matrix ensemble clustering

Calibrating distribution system models to aid in the accuracy of simulations such as hosting capacity analysis is increasingly important in the pursuit of the goal of integrating more distributed energy resources. The recent availability of smart meter data is enabling the use of machine learning tools to automatically achieve model calibration tasks. This research focuses on applying machine learning to the phase identification task, using a co‐association matrix‐based, ensemble spectral clustering approach. The proposed method leverages voltage time series from smart meters and does not require existing or accurate phase labels. This work demonstrates the success of the proposed method on both synthetic and real data, surpassing the accuracy of other phase identification research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advances in Westinghouse fuel rod design technology (PAD5)

The Westinghouse Performance Analysis and Design (PAD) code for light-water reactors has been recently updated to version PAD5 and submitted to NRC for review. PAD5 incorporates extensive updates in fuel performance and material property models, including fuel thermal conductivity, pellet fragment relocation, fission gas release, fission gas swelling, and cladding creep and growth. Advances in thermal models are mainly in pellet fragment relocation, radial power distribution within the pellet, and the changes in fuel thermal conductivity due to changes in temperature, burnup and fuel porosity. The PAD5 thermal fission gas release model is a phenomenological model based on the irradiation dependence of the gas release from mechanistic processes for the diffusion of the fission gas generated in the fuel grains to the grain boundaries, formation of fission gas bubbles on the grain boundaries and release of the fission gas when these grain boundary bubbles inter-link. The PAD5 cladding creep model is predominantly a combination of the following mechanisms: thermal creep, irradiation induced creep, and irradiation enhanced creep. The fuel performance database used for the development, calibration and testing of the PAD5 code covers a broad range of both commercial irradiation data and test rod data and requires continuously additional data focusing on the latest development of the PAD5 code. Test programs are also included in the database. These data are checked and stored in a hierarchical database structure that supports the automation of model development and calibration. New data, once incorporated into the database, can be quickly evaluated with respect to key fuel and cladding performance models to confirm expected trends or to evaluate potential model improvements. This automated calibration system has been integrated with state-of-the-art optimization packages in DAKOTA Analysis Kit to provide for advanced statistical assessments and model coefficient optimization. Calibration results are automatically tabulated and plotted to provide easy assessment of trends or new behaviors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A gamma ray monitor for the OSO-7 spacecraft

A 3 in. x 3 in. NaI(Tl) gamma ray (0.3 to 10 MeV) spectrometer with a CsI(Na) charged particle and anti-Compton shield has been developed for the Orbiting Solar Observatory (OSO-7) which was launched September 30, 1971. The instrument, designed for a rotating wheel compartment, utilizes a 377 channel quadratic PHA with accumulation times of 3, 1, or 0.5 minutes. Quick look and calibration data obtained via a direct data link to a minicomputer allows near real time monitoring and control of the experiment. Various commands changing the operating mode can be executed. The functions which can be commanded include: rotation of the quadrants in which data is collected by 90 deg; gain adjustment of the central detector over a 6:1 range; manual or automatic sequencing of calibrations; variations of accumulation times by telemetering selected channels; and selection of reference directions. A small X-ray detector covering the range 7.5 to 120 keV is also included.

Higbie, P. R.↗

A full range detector for the HIRRBS high resolution RBS magnetic spectrometer

The UAlbany HIRRBS (High Resolution RBS) system has been updated for better use in rapid analysis. The focal plane detector now covers the full range from U down to O using a linear stepper motor to translate the 1-cm detector across the 30-cm range. Input is implemented with zero-back-angle operation in all cases. The chamber has been modified to allow for quick swapping of sample holders, including a channeling goniometer. A fixed standard surface-barrier detector allows for normal RBS simultaneously with use of the magnetic spectrometer. The user can select a region on the standard spectrum or can select an element edge or an energy point for collection of the expanded spectrum portion. The best resolution currently obtained is about 2-to-3 keV, probably representing the energy width of the incoming beam. Calibration is maintained automatically for any spectrum portion and any beam energy from 1.0 to 3.5 MeV. Element resolving power, sensitivity and depth resolution are shown using several examples. Examples also show the value of simultaneous conventional RBS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

xcalib : a focal spot calibrator for intense X-ray free-electron laser pulses based on the charge state distributions of light atoms

The xcalib toolkit has been developed to calibrate the beam profile of an X-ray free-electron laser (XFEL) at the focal spot based on the experimental charge state distributions (CSDs) of light atoms. Characterization of the fluence distribution at the focal spot is essential to perform the volume integrations of physical quantities for a quantitative comparison between theoretical and experimental results, especially for fluence-dependent quantities. The use of the CSDs of light atoms is advantageous because CSDs directly reflect experimental conditions at the focal spot, and the properties of light atoms have been well established in both theory and experiment. Theoretical CSDs are obtained using xatom , a toolkit to calculate atomic electronic structure and to simulate ionization dynamics of atoms exposed to intense XFEL pulses, which involves highly excited multiple core-hole states. Employing a simple function with a few parameters, the spatial profile of an XFEL beam is determined by minimizing the difference between theoretical and experimental results. The optimization procedure employing the reinforcement learning technique can automatize and organize calibration procedures which, before, had been performed manually. xcalib has high flexibility, simultaneously combining different optimization methods, sets of charge states, and a wide range of parameter space. Hence, in combination with xatom , xcalib serves as a comprehensive tool to calibrate the fluence profile of a tightly focused XFEL beam in the interaction region.

Instruments & Instrumentation↗

Computational Removal of Lanthanum-Cerium Bromide Self-Activity

It has been reported that detectors made of lanthanum–cerium halides, such as LaBr3(Ce) and CeBr3 have superior energy resolution for gamma-radiation detection compared to that offered by conventional sodium iodide [NaI(T1)] detectors. However, it has also been observed that the lanthanum–cerium halides contain certain amount of self-activity caused by the radioactive isotope 138La. Additionally, LaBr3(Ce) and CeBr3 crystals have also been reported to be affected by β-contamination in the low-energy and α-contamination in the high-energy regions. This paper presents a computational approach to reduce self-activity and contamination for LaBr3(Ce) and CeBr3 detectors using a third reference NaI(T1) detector. This procedure can be implemented as an automatic self-calibration module for gamma-radiation detectors made of LaBr3(Ce) and/or CeBr3 crystals.

Lanthanum bromide, Cerium bromide, Linear separati↗

Inexpensive portable drug detector

Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.

Dimeff, J.↗

Automated calibration of a flight particle spectrometer

A system for calibrating both electron and ion imaging particle spectrometers was devised to calibrate flight instruments in a large vacuum facility in the Space Science Laboratory at the Marshall Space Flight Center. An IBM-compatible computer was used to control, via an IEEE 488 buss protocol, a two-axis gimbled table, constructed to fit inside the tank. Test settings of various diagnostic voltages were also acquired via the buss. These spectrometers constructed by the author at UCSD were calibrated in an automatic procedure programmed on the small computer. Data was up-loaded to the SSL VAX where a program was developed to plot the results.

Torbert, R. B.↗

Optical fiber voltage sensors for broad temperature ranges

We describe the development of an optical fiber ac voltage sensor for aircraft and spacecraft applications. Among the most difficult specifications to meet for this application is a temperature stability of +/- 1 percent from -65 C to +125 C. This stability requires a careful selection of materials, components, and optical configuration with further compensation using an optical-fiber temperature sensor located near the sensing element. The sensor is a polarimetric design, based on the linear electro-optic effect in bulk Bi4Ge3O12. The temperature sensor is also polarimetric, based on the temperature dependence of the birefringence of bulk SiO2. The temperature sensor output is used to automatically adjust the calibration of the instrument.

Rose, A. H.↗

A Description of the Philips SO2 Monitor

Strict standards for ambient sulfur dioxide requirements in the San Francisco Bay Area result in strict criteria for monitor operations by private industry. Of nine different monitors tested, three are acceptable. One, the Phillips PW 9700, senses sulfur dioxide by coulometric reaction with bromine in a potassium bromide solution. The monitor has a high degree of sensitivity, rapid response, and stable attendance or maintenance is aided by quality construction, internal reagent supply, and elimination of reagent pump. Options include automatic zeroing and calibration, probe filter and heater, and telemetering output.

Potter, L. B.↗

Innovative Technology Transfer Partnerships

The National Aeronautics and Space Administration (NASA) seeks to license its Advanced Tire and Strut Pressure Monitor (TSPM) technology. The TSPM is a handheld system to accurately measure tire and strut pressure and temperature over a wide temperature range (20 to 120 OF), as well as improve personnel safety. Sensor accuracy, electronics design, and a simple user interface allow operators quick, easy access to required measurements. The handheld electronics, powered by 12-VAC or by 9-VDC batteries, provide the user with an easy-to-read visual display of pressure/temperature or the streaming of pressure/temperature data via an RS-232 interface. When connected to a laptop computer, this new measurement system can provide users with automated data recording and trending, eliminating the chance for data hand-recording errors. In addition, calibration software allows for calibration data to be automatically utilized for the generation of new data conversion equations, simplifying the calibration processes that are so critical to reliable measurements. The design places a high-accuracy pressure sensor (also used as a temperature sensor) as close to the tire or strut measurement location as possible, allowing the user to make accurate measurements rapidly, minimizing the amount of high-pressure volumes, and allowing reasonable distance between the tire or strut and the operator. The pressure sensor attaches directly to the pressure supply/relief valve on the tire and/or strut, with necessary electronics contained in the handheld enclosure. A software algorithm ensures high accuracy of the device over the wide temperature range. Using the pressure sensor as a temperature sensor permits measurement of the actual temperature of the pressurized gas. This device can be adapted to create a portable calibration standard that does not require thermal conditioning. This allows accurate pressure measurements without disturbing the gas temperature. In-place calibration can save considerable time and money and is suitable in many process applications throughout industry.

Kohler, Jeff↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic Retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the OVERFLOW Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent Systems Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and optimized grid systems unique to any given testing condition. Simulations were subjected to successive levels of grid refinement in order to determine solution independence from grid resolution. OVERFLOW Reynolds Averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinsoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle.

Supersonic Retropropulsion↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the Overflow Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent System Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and unique grid systems optimized for any given testing condition. Solution independence from grid resolution was determined by successively increasing grid refinement until asymptotic convergence of the mean aerodynamic loads was observed. Overflow Reynolds-averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinusoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle. Initial investigations into the effect of turbulence modeling fidelity demonstrated significant differences between the aerodynamic loads simulated with RANS and Detached Eddy Simulation (DES). Multiple flow mechanisms were identified as root causes of these differences, including bow shock shape augmentation and reduced entrainment due to reduced turbulence in the DES simulations. Initial comparisons of pitching moment control authority and aerodynamic drag performance between the tested nozzle configurations demonstrated that the 1E configuration may be more advantageous for the Mars Entry, Descent, and Landing (EDL) task.

Supersonic Retropropulsion↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the Overflow Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent System Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and unique grid systems optimized for any given testing condition. Solution independence from grid resolution was determined by successively increasing grid refinement until asymptotic convergence of the mean aerodynamic loads was observed. Overflow Reynolds-averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinusoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle. Initial investigations into the effect of turbulence modeling fidelity demonstrated significant differences between the aerodynamic loads simulated with RANS and Detached Eddy Simulation (DES). Multiple flow mechanisms were identified as root causes of these differences, including bow shock shape augmentation and reduced entrainment due to reduced turbulence in the DES simulations. Initial comparisons of pitching moment control authority and aerodynamic drag performance between the tested nozzle configurations demonstrated that the 1E configuration may be more advantageous for the Mars Entry, Descent, and Landing (EDL) task.

Supersonic Retropropulsion↗

Extensometer automatically measures elongation in elastomers

Extensometer, with a calibrated shaft, measures the elongation of elastomers and automatically records this distance on a chart. It is adaptable to almost any tensile testing machine and is fabricated at a relatively low cost.

Hooper, C. D.↗

Development of an automated potable water bactericide monitoring unit

A monitor unit has been developed that permits the direct determination of the level of elemental iodine, used for microbiological control, in a spacecraft potable water supply system. Salient features of unit include low weight, volume and maintenance requirements, complete automatic operation, no inflight calibration, no expendables (except electrical current) and high accuracy and precision. This unit is capable of providing a signal to a controller that, in turn, automatically adjusts the addition rate of iodine to the potable water system so that a predetermined level of iodine can be maintained. In addition, the monitor provides a reading whereby the crewman can verify that the proper amount of iodine (within a range) is present in the water. A development history of the monitor is presented along with its design and theory of operation. Also presented are the results generated through testing of the unit in a simulated Shuttle potable water system.

Walsh, J. M.↗

Peristaltic pump-based low range pressure sensor calibration system

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗