At least 145 records · Page 8

Actinometric measurement of j(O3-O(1D)) using a luminol detector

The photolysis frequency of ozone to singlet D oxygen atoms has been measured by means of a chemical actinometer using a luminol based detector. The instrument measures j(O3-O(1D)) with a precision of 10 percent. The data collected in winter and spring of 1991 is in agreement with model predictions and previously measured values. Data from a global solar radiometer can be used to estimate the effects of local cloudiness on j(O3-O(1D)).

Bairai, Solomon T.↗

U-238-U-234-Th-230-Th-232 systematics and the precise measurement of time over the past 500,000 years

A method is presented for the high-precision measurement of the Th-230 abundance in corals by isotope-dilution mass spectrometry using techniques developed by Chen and Wasserburg (1980, 1981) and Chen et al. (1986). It is shown that 6 x 10 to the 8th atoms of Th-230 can be measured to + or - 30 percent (2 sigma) and 2 x 10 to the 10th atoms of Th-230 to + or - 2 percent. The time over which useful age data on corals can be obtained ranges from a few years to about 500 ky, with the uncertainty in age ranging from 5 y for a 180-y-old coral, to 44 y for a 8294-y-old coral, to 1.1 ky for a 123.1-ky-old coral. Ages were determined with high analytical precision for several corals that grew during high sea-level stands about 120 ky ago, supporting the view that the dominant cause of Pleistocene climate change was Milankovitch forcing.

Edwards, R. Lawrence↗

Photochemistry of Methane in Model Atmospheres of Jupiter and Titan

The two central findings were 1) hydrogen atoms and hydrogen molecules photodissociated from methane are relatively richer in H than in D in other words deuterium atoms have a greater probability of remaining attached to the carbon atom. Titan, a moon of Saturn has an atmosphere which is largely nitrogen but also contains about 3% methane as well as smaller amounts of C2 and C3 hydrocarbons. If all these hydrocarbons are of biological origin, the isotopic scrambling occurring in living organisms would result in equal D atom abundances. On the other hand, if the higher hydrocarbons are derived from methane by photodissociation of methane, they should be richer in D than methane. Precise values for the enrichment were derived from our photochemical data. 2) When methane is dissociated by vuv light, methylene is produced in a singlet state. This explains why the higher hydrocarbons are sparse on Jupiter but relatively rich on Titan.

Bersohn, Richard↗

Independent Technical Assessment of NASA and External Quantum Sensing Capability

The recent FY 2020 federal Research and Development Budget Priorities memo addresses the leadership need in Quantum Information Science (QIS) directing agencies to “prioritize QIS research and development (R&D), which will build the technical and scientific base necessary to explore the next generation of QIS theory, devices, and applications.” Quantum Sensing (QS) is an integral part of QIS. NASA is a key part of the directive to forward American space exploration and commercialization by providing “capabilities that have broad potential applications in space and on Earth.” QS provides an arena for NASA to demonstrate leadership in both areas of the administrative directive. QS uses quantum properties to achieve unprecedented measurement sensitivity and performance, including quantum-enhanced methodologies that outperform their classical counterparts. Typical quantum sensors exploit techniques such as atomic systems, matter waves, quantum entanglement, quantum superposition of states, quantum illumination methods, and manipulation of photons and atoms, in general. Guided by advancements in our ability to generate, manipulate, and control quantum systems, the emerging quantum sensing technologies promise unrivalled sensitivity, resolution, and precision, potentially leading to game-changing applications. Significant gains include technologies important for a range of NASA missions such as remote sensing, in situ measurements, metrology, interferometry, quantum communication, ranging, imaging, radar and lidar receivers, and gravity measurements. NASA Engineering and Safety Center has convened an independent external panel, comprising of Quantum Sensing Experts from Government, DoD, academia, and Federally funded Research and Development Center to conduct an independent technical assessment of the agency's capabilities in Quantum Sensing to understand NASA's internal needs and competencies related to Quantum Sensing and compare agency capabilities with those available externally including industry, academia, and other government agencies. The outcomes of the assessment will help the agency in establishing appropriate strategies and investments to develop and maintain the state-of-the-art sensing competence and capabilities required to meet the agency’s future needs. The External Experts Panel (EEP) is collaborating with HQ, various NASA Center and the representatives in the NASA Quantum Sensing Community of Practice (QS CoP), a part of NASA Sensors and Instrumentation Technical Fellow Technical Discipline Team, in obtaining common, current understanding of agency mission needs where QS can be an important enabler for future needs, and any programs, projects, assets, and technologists working in QS. The EEP organized a Quantum Sensing Workshop of practitioners from industry, academia, other government agencies, external experts, and interested NASA personnel to gather the assessment information. EEP also conducted information gathering on the industry at large, educational institutions, and other government agency research efforts for capture in the assessment database. At the conclusion of this assessment, EEP team will develop findings and conclusions describing NASA’s capabilities for the mission needs, NASA's relative position on new, enabling technologies, and an analysis of the gaps that may present any risks to near-term or far-term mission needs. This presentation will give details of the NASA and External Quantum Sensing Assessment outcomes, findings, observations, and its recommendation to NASA as how it can advance Quantum Sensing technologies and techniques for its science and explorations related missions.

External Quantum Sensing Capability↗

Laboratory Methods for the Measurement of Pollutants in Water and Waste Effluents

The requirement for accurate, precise, and rapid analytical procedures for the examination of water and waste samples requires the use of a variety of instruments. The instrumentation in water laboratories includes atomic absorption, UV-visible. and infrared spectrophotometers, automatic colorimetric analyzers, gas chromatographs and mass spectrometers. Because of the emphasis on regulatory action, attention is being directed toward quality control of analytical results. Among the challenging problems are the differentiation of metallic species in water at nanogram concentrations, rapid measurement of free cyanide and free ammonia, more sensitive methods for arsenic and selenium and improved characterization of organic contaminants.

Ballinger, Dwight G.↗

CO2 Reduction Assembly Prototype Using Microlith-Based Sabatier Reactor for Ground Demonstration

The utilization of CO2 to produce life support consumables, such as O2 and H2O, via the Sabatier reaction is an important aspect of NASA's cabin Atmosphere Revitalization System (ARS) and In-Situ Resource Utilization (ISRU) architectures for both low-earth orbit and long-term manned space missions. Carbon dioxide can be reacted with H2, obtained from the electrolysis of water, via Sabatier reaction to produce methane and H2O. Methane can be stored and utilized as propellant while H2O can be either stored or electrolyzed to produce oxygen and regain the hydrogen atoms. Depending on the application, O2 can be used to replenish the atmosphere in human-crewed missions or as an oxidant for robotic and return missions. Precision Combustion, Inc. (PCI), with support from NASA, has previously developed an efficient and compact Sabatier reactor based on its Microlith® catalytic technology and demonstrated the capability to achieve high CO2 conversion and CH4 selectivity (i.e., ≥90% of the thermodynamic equilibrium values) at high space velocities and low operating temperatures. This was made possible through the use of high-heat-transfer and high-surface-area Microlith catalytic substrates. Using this Sabatier reactor, PCI designed, developed, and demonstrated a stand-alone CO2 Reduction Assembly (CRA) test system for ground demonstration and performance validation. The Sabatier reactor was integrated with the necessary balance-of-plant components and controls system, allowing an automated, single "push-button" start-up and shutdown. Additionally, the versatility of the test system prototype was demonstrated by operating it under H2-rich (H2/CO2 of >4), stoichiometric (ratio of 4), and CO2-rich conditions (ratio of <4) without affecting its performance and meeting the equilibrium-predicted water recovery rates. In this paper, the development of the CRA test system for ground demonstration will be discussed. Additionally, the performance results from testing the system at various operating conditions and the results from durability testing will be presented.

Junaedi, Christian↗

Smallest Nanoelectronics with Adatom Chains

This viewgraph presentation is focused on the general aspect of atomic chain electronics that I have been studying. Results have been published before, but are being rederived here using a new physical/mathematical picture/model, which deepens the physical understanding. Precise adatom structures can be used as a template on a regulated surface with no uncertainty.

Yamada, Toshishige↗

The Investigation Of Carbon Contamination And Sputtering Effects Of Xenon Ion Thrusters

The Electro-Physics Branch of the NASA Glenn Research Center investigates the effect of atomic oxygen, environmental durability of high performance power materials and surfaces, and low earth orbit. One of its current projects involves the analysis of ion thrusters. Ion thrusters are devices that initiate a beam of ions to a target area. The type of ion thruster that I have been working with this Summer of 2004 emits positively charged Xenon (Xe(+)) atoms through two grids, the screen grid and the accelerator grid, after it enters an ionization chamber. Insulators are used to mechanically hold and separate these two grids. A propellant isolator, an instrument that closely resembles insulators, is placed in front of the ionization chamber. Both the insulator and isolator are made with a ceramic compound and filled with insulating beads. The main difference between the two devices is that the propellant isolator allows gas to flow through, in this case, the gas is Xe(+) and the insulators do not. In order to avoid carbon deposits and other contaminating chemicals to settle on the insulators and propellant isolator, a metal shadow shield is placed around them. These shadow shields function as a protectant and can be shaped in numerous configurations. Part of my job responsibility this summer is to investigate the effectiveness of different shadow shields that are utilized on three different ion engines: the NSTAR (NASA Solar Electric Propulsion Technology Application Readiness), JIMO (Jupiter Icy Moons Orbiter), and NEXIS (Nuclear Electric Xenon Ion System). Using calculus and other mathematical tactics, I was asked to find the total flux of carbon contamination that was able to pass the protectant shadow shield. I familiarized myself with the software program, MathCad2004, to help perform some mathematical computations such as complex integration. Another method of studying the probability of contamination is by experimental simulation. After attaining the precise parameters of the actual shadow shields, I created replicas of three types of shadow shielding to be used to undergo testing. It will be placed in a machine that produces carbon atoms at a high temperature of 200 C. or beam is aimed at a targeted material. As a result of this collision, atoms and other particles are ejected out of the target surface. Another part of my internship consisted of research on sputter ejection, or the angle distribution of sputtered material. This research entailed finding the past results of sputter ejection investigation as well as creating another type of mock simulation. Other minor projects include calculating the path of Xe(+) gas through the insulating beads of the isolators and assisting my mentor in collecting data for his paper for the Joint Propulsion Conference & Exhibit to be held July 11-14,2004 in Fort Lauderdale, Florida.

Prak, Moline K.↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

The scattered solar X-ray background of the ROSAT PSPC

A model for accurately reproducing the light curves and spectra of the scattered solar X-ray background (SB) affecting ROSAT XRT/PSPC pointed observations is presented and demonstrated. This procedure, the modeling and subtraction of the SB, is vital for analysis of all observations of extended X-ray objects and the soft X-ray diffuse background where noncosmic background constituents must be precisely known. At the orbital altitude of ROSAT, about 550 km, and the zenith angles at which the XRT/PSPC observers, 97 deg or less, the scattering is dominated by atomic oxygen with Thomson-scattered X-rays in the 1/4 keV band and oxygen K-alpha fluorescently scattered X-rays at 0.54 keV. This produces field-of-view-integrated minimum count rates in the 0.1-1.0 keV band of about 0.25 counts/s during dayside observations with excursions to about 40 counts/s or more in particularly bad geometries. Typical cosmic background count rates in the same band range from 3 to 12 counts/s, demonstrating the need for the procedure described here.

Snowden, S. L.↗

NASA Tech Briefs, April 2005

Gas-Tolerant Device Senses Electrical Conductivity of Liquid Nanoactuators Based on Electrostatic Forces on Dielectrics Replaceable Microfluidic Cartridges for a PCR Biosensor CdZnTe Image Detectors for Hard-X-Ray Telescopes High-Aperture-Efficiency Horn Antenna Full-Circle Resolver-to-Linear-Analog Converter Continuous, Full-Circle Arctangent Circuit Advanced Three-Dimensional Display System Automatic Focus Adjustment of a Microscope Topics covered include: FastScript3D - A Companion to Java 3D; Generating Mosaics of Astronomical Images; Simulating Descent and Landing of a Spacecraft; Simulating Vibrations in a Complex Loaded Structure; Rover Sequencing and Visualization Program; Software Template for Instruction in Mathematics; Support for User Interfaces for Distributed Systems; Nanostructured MnO2-Based Cathodes for Li-Ion/Polymer Cells; Multi-Layer Laminated Thin Films for Inflatable Structures; Two-Step Laser Ranging for Precise Tracking of a Spacecraft; Growing Aligned Carbon Nanotubes for Interconnections in ICs; Multilayer Composite Pressure Vessels; Texturing Blood-Glucose-Monitoring Optics Using Oxygen Beams; Fault-Tolerant Heat Exchanger; Atomic Clock Based on Opto-Electronic Oscillator; Microfocus/Polycapillary-Optic Crystallographic X-Ray Sys; Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings; One-Dimensional Photonic Crystal Superprisms; Measuring Low-Order Aberrations in a Segmented Telescope; Mapping From an Instrumented Glove to a Robot Hand; Application of the Hilbert-Huang Transform to Financial Data; Optimizing Parameters for Deep-Space Optical Communication; and Low-Shear Microencapsulation and Electrostatic Coating.

Source record↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. Nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely hig-hsurface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL s ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile.

Sheam, Michael J.↗

Reflective Coating for Lightweight X-Ray Optics

X-ray reflective coating for next generation's lightweight, high resolution, optics for astronomy requires thin-film deposition that is precisely fine-tuned so that it will not distort the thin sub-mm substrates. Film of very low stress is required. Alternatively, mirror distortion can be cancelled by precisely balancing the deformation from multiple films. We will present results on metallic film deposition for the lightweight optics under development. These efforts include: low-stress deposition by magnetron sputtering and atomic layer deposition of the metals, balancing of gross deformation with two-layer depositions of opposite stresses and with depositions on both sides of the thin mirrors.

Chan, Kai-Wing↗

Preliminary Investigation of Onboard Orbit Determination Using Deep Space Atomic Clock Based Radio Tracking

The Deep Space Atomic Clock mission is developing a small, mercury ion atomic clock with Allan deviation of less than 1e-14 at one day (current estimates < 3e-15) for a yearlong space demonstration beginning late- 2016/early-2017. DSAC’s stability yields one-way radiometric data precision on par with current two-way data. Uplink one-way tracking with an appropriately configured radio enables the possibility of onboard, autonomous radio navigation. This study examines the modeling needed to efficiently process this data for an onboard implementation.

Ely, Todd A.↗

Design considerations for ultra-precision magnetic bearing supported slides

Development plans for a prototype servocontrolled machine with 1 angstrom resolution of linear motion and 50 mm range of travel are described. Two such devices could then be combined to produce a two dimensional machine for probing large planar objects with atomic resolution, the Angstrom Resolution Measuring Machine (ARMM).

Slocum, Alexander H.↗

Spray combustion under oscillatory pressure conditions

The performance and stability of liquid rocket engines is often argued to be significantly impacted by atomization and droplet vaporization processes. In particular, combustion instability phenomena may result from the interactions between the oscillating pressure field present in the rocket combustor and the fuel and oxidizer injection process. Few studies have been conducted to examine the effects of oscillating pressure fields on spray formation and its evolution under rocket engine conditions. The pressure study is intended to address the need for such studies. In particular, two potentially important phenomena are addressed in the present effort. The first involves the enhancement of the atomization process for a liquid jet subjected to an oscillating pressure field of known frequency and amplitude. The objective of this part of the study is to examine the coupling between the pressure field and or the resulting periodically perturbed velocity field on the breakup of the liquid jet. In particular, transverse mode oscillations are of interest since such modes are considered of primary importance in combustion instability phenomena. The second aspect of the project involves the effects of an oscillating pressure on droplet coagulation and secondary atomization. The objective of this study is to examine the conditions under which phenomena following the atomization process are affected by perturbations to the pressure or velocity fields. Both coagulation and represent a coupling mechanism between the pressure field and the energy release process in rocket combustors. It is precisely this coupling which drives combustion instability phenomena. Consequently, the present effort is intended to provide the fundamental insights needed to evaluate these processes as important mechanisms in liquid rocket instability phenomena.

Jacobs, H. R.↗

Allan deviation computations of a linear frequency synthesizer system using frequency domain techniques

Allan Deviation computations of linear frequency synthesizer systems have been reported previously using real-time simulations. Even though it takes less time compared with the actual measurement, it is still very time consuming to compute the Allan Deviation for long sample times with the desired confidence level. Also noises, such as flicker phase noise and flicker frequency noise, can not be simulated precisely. The use of frequency domain techniques can overcome these drawbacks. In this paper the system error model of a fictitious linear frequency synthesizer is developed and its performance using a Cesium (Cs) atomic frequency standard (AFS) as a reference is evaluated using frequency domain techniques. For a linear timing system, the power spectral density at the system output can be computed with known system transfer functions and known power spectral densities from the input noise sources. The resulting power spectral density can then be used to compute the Allan Variance at the system output. Sensitivities of the Allan Variance at the system output to each of its independent input noises are obtained, and they are valuable for design trade-off and trouble-shooting.