Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Elementary theory of synchronous arterio-arterial blood pumps

In the technique of arterio-arterial pumping, a volume of fluid is withdrawn from the aorta during systole and reinjected during diastole, thereby reducing the systolic pressure of the heart and adding energy to the systemic circulation. It is found that an upper bound for the effectiveness of such devices is given by a formula that considers stroke output of the unaided heart and the increment caused by the pump with a stroke. The division of effort of the pump between the reduction of pressure and the increase of flow depends on the physiological mechanical impedance of the heart. The total effect is, however, independent of the impedance.

Jones, R. T.↗

Ultrasonic Doppler measurement of renal artery blood flow

An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

Freund, W. R.↗

Quantitative analysis of regional myocardial performance in coronary artery disease

Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.

Stewart, D. K.↗

Parametric Performance of a Spiral-Artery, Liquid-Trap-Diode Heat Pipe

A series of parametric investigations are described which determine the effect of various fluid charges on the performance of a 0.635-cm-diam spiral-artery, liquid-trap diode in both the forward and reverse modes. Specific parameters such as forward- and reverse-mode conductances, shutdown times and energies, and recovery to forward-model operation, are evaluated for ethane as a working fluid in the temperature range 170 K to 220 K. Results indicate that the heat pipe will not reliably start up in the forward mode. However, startup can be initiated when preceded by a diode reversal. Also included are data which show the susceptibility of the diode to fluid charge and tilt. The optimum fluid charge was found to be 2.67 g and transport capability at this charge was in excess of 1200 W-cm at 200 K. The diode in the reverse mode exhibited a rapid shutdown (within 9 min) with a shutdown energy of 1150 J (0.32 Wh).

Williams, R. J.↗

Evaluation of thallium-201 scanning for detection of latent coronary artery disease

The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.

Johnson, P. C.↗

Compliant transducer measures artery profile

Instrument consisting of compliant fingers with attached semiconductor pickups measures inside contours of narrow vessels. Instrument, originally designed to monitor human arteries, is drawn through vessel to allow finges to follow contours. Lead wires transmit electrical signals to external processing equipment.

Feldstein, C.↗

Dynamics of change in rat arterial pressure under conditions of immobilization

Emotional stress developed in immobilized rats was shown to be accompanied by changes in the regulation of arterial pressure and the frequency of cardiac contractions. A group of adapting rats displayed definite resistance to emotional stress, while a group of rats incapable of adapting to acute emotional stress died with characteristics of cardiovascular insufficiency. The mechanisms providing resistance to emotional stress in numerous conflict situations were analyzed.

Yumatov, Y. A.↗

Changes in cardiac output and tibial artery flow during and after progressive LBNP

A 3.0 MHz Pulsed Doppler velocity meter (PD) was used to determine blood velocities in the ascending aorta from the suprasternal notch before, during and after progressive 5 min stages of lower body negative pressure (LBNP) in 7 subjects. Changes in stroke volume were calculated from the systolic velocity integrals. A unique 20 MHz PD was used to estimate bloodflow in the posterior tibial artery. With -20 torr mean stroke volume fell 11% and then continued to decline by 48% before LBNP was terminated. Mean tibial flow fell progressively with LBNP stress, due to an increase in reverse flow component and a reduction in peak forward flow and diameter. Stroke volume increased and heart rate fell dramatically during the first 15 sec of recovery. The LBNP was terminated early in 2 subjects because of vasovagal symptons (V). During V the stroke volume rose 86% which more than compensated for the drop in heart rate. This implies that V is accompanied by a paradoxical increase in venous return and that the reduction in HR is the primary cardiovascular event. During the first 15 sec of recovery these 2 subjects had a distinctive marked rise to heart rate reminiscent of the Bainbridge reflex.

Source record↗

Velocity and attenuation of sound in arterial tissues

The velocity of sound in excised human and canine arterial tissues is measured in order to serve as a basis for the development and application of ultrasonic techniques for the diagnosis of atherosclerotic lesions. Measurements of sound velocity at different regions of 11 human and six canine aortas were made by a time delay spectrometer technique at frequencies from 2 to 10 MHz, and compared with ultrasonic attenuation parameters and the results of biochemical assays. Sound velocity is found to increase with increasing attenuation at all frequencies, and with increasing collagen content. A strong dependence of sound velocity on cholesterol content or low calcium contents is not observed, although velocities of up to 2000 m/sec are observed in highly organized calcified lesions. A decrease in velocity with decreasing temperature is also noted. It is thus concluded that it is principally the differences in tissue collagen levels that contribute to image formation according to sound velocity.

Rooney, J. A.↗

Effect of mild atherosclerosis on flow resistance in a coronary artery casting of man

An in-vitro flow study was conducted in a mildly atherosclerotic main coronary artery casting of man using sugar-water solutions simulating blood viscosity. Steady flow results indicated substantial increases in pressure drop, and thus flow resistance at the same Reynolds number, above those for Poiseuille flow by 30 to 100 percent in the physiological Reynolds number range from about 100 to 400. Time-averaged pulsatile flow data showed additional 5 percent increases in flow resistance above the steady flow results. Both pulsatile and steady flow data from the casting were found to be nearly equal to those from a straight, axisymmetric model of the casting up to a Reynolds number of about 200, above which the flow resistance of the casting became gradually larger than the corresponding values from the axisymmetric model.

Back, L. H.↗

Measurement and prediction of flow through a replica segment of a mildly atherosclerotic coronary artery of man

Pressure distributions were measured along a hollow vascular axisymmetric replica of a segment of the left circumflex coronary artery of man with mildly atherosclerotic diffuse disease. A large range of physiological Reynolds numbers from about 60 to 500, including hyperemic response, was spanned in the flows investigation using a fluid simulating blood kinematic viscosity. Predicted pressure distributions from the numerical solution of the Navier-Stokes equations were similar in trend and magnitude to the measurements. Large variations in the predicted velocity profiles occurred along the lumen. The influence of the smaller scale multiple flow obstacles along the wall (lesion variations) led to sharp spikes in the predicted wall shear stresses. Reynolds number similarity was discussed, and estimates of what time averaged in vivo pressure drop and shear stress might be were given for a vessel segment.

Back, L. H.↗

Fluid dynamic study in a femoral artery branch casting of man with upstream main lumen curvature for steady flow

An in-vitro, steady flow investigation was conducted in a hollow, transparent vascular replica of the profunda femoris branch of man for a range of physiological flow conditions. The replica casting tested was obtained from a human cadaver and indicated some plague formation along the main lumen and branch. The flow visualization observations and measured pressure distributions indicated the highly three-dimensional flow characteristics with arterial curvature and branching, and the important role of centrifugal effects in fluid transport mechanisms.

Cho, Y. I.↗

Effect of posture on arterial baroreflex control of heart rate in humans

The effects of blood-volume redistribution induced by postural changes on baroreflex activity are investigated. The central blood volume and baroreceptor functions of ten males between 23-51 years old were examined while they were in the head-up tilt (HUT), head-down tilt (HDT), and supine positions. It is observed that during HDT at 15 deg the pulse interval over the first five cardiac cycles following neck suction onset is 51 + or - 18 ms longer, at 30 deg it is 61 + or - 20 ms longer, and at 45 deg it is 74 + or - 35 ms longer than at supine; during HUT at 15 deg the pulse interval is 25 + or - 9 ms shorter than when supine, but for the 30 and 45 deg there is no significant difference in pulse interval detected. The data reveal that posture does modify arterial baroreflex control of heart rate.

Harrison, M. H.↗

Modelling the performance of the tapered artery heat pipe design for use in the radiator of the solar dynamic power system of the NASA Space Station

The paper presents a computer program developed to model the steady-state performance of the tapered artery heat pipe for use in the radiator of the solar dynamic power system of the NASA Space Station. The program solves six governing equations to ascertain which one is limiting the maximum heat transfer rate of the heat pipe. The present model appeared to be slightly better than the LTV model in matching the 1-g data for the standard 15-ft test heat pipe.

Evans, Austin Lewis↗

Best estimate of luminal cross-sectional area of coronary arteries from angiograms

We have reexamined the problem of estimating the luminal area of an elliptically-shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cae of two orthogonal views, closed form expressions have been derived for calculating the area and the uncertainty. Assuming that the underlying ellipse has limited ellipticity (major/minor axis ratio less than five), it is shown that the average uncertainty in the area is less than 14 percent. When more than two views are available, we suggest using a least-squares fit method to extract all available information from the data.

Lee, P. L.↗

Ultrasonic Imaging Of Deep Arteries

Swept-frequency sound replaces pulsed sound. Ultrasonic medical instrument produces images of peripheral and coronary arteries with resolutions higher and at depths greater than attainable by previous ultrasonic systems. Time-delay-spectrometry imager includes scanning, image-processing, and displaying equipment. It sweeps in frequency from 0 to 10 MHz in 20 ms, pauses for 5 ms, and repeats sweep. Intended for use in noninvasive detection and measurement of atherosclerotic lesions.

Rooney, James A.↗

Flow measurements in a model of the mildly curved femoral artery of man

The effects of curvature on the flow rate near the wall in the vicinity of the mildly curved femoral artery of man, and on the pressure distributions along the curved segment, were investigated using glass and tygon flow models constructed to conform to the shape of the femoral angiogram of a human subject. The test fluid was 33 percent aqueous sucrose. Steady flow observations, made using a dye flow visualization system, revealed a flow pattern like that observed in coiled pipes. A double helical type flow was found to develop, with converging streamlines in the wall vicinity from the upper and lower plane of curvature merging asymptotically along the inner curvature in a stable manner. Pressure measurements for steady flow revealed progressively larger pressure drops with distance along the entrance region of the curved segment, relative to that for a straight lumen.

Back, L. H.↗