Miniature space-borne memory monthly technical report no. 2, jan. 4 - 31, 1965
High temperature testing of adhesives and metal protective platings - construction of memory system
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High temperature testing of adhesives and metal protective platings - construction of memory system
Investigation of the pressure load carrying capacity and fatigue strength of filament-wound glass-reinforced plastic pressure vessels subjected to static and cyclic loading at ambient and cryogenic (liquid nitrogen) temperature environments. The results indicate that the static fatigue problem is not critical at cryogenic temperatures. Under static loading at liquid nitrogen temperature, a reinforced plastic cylinder sustained pressurization for 88 days without failure at about 90% of the single cycle burst strength. At ambient temperature, the static life at 90% of the burst strength was about 7 min. Under cyclic loading in liquid nitrogen, no failure resulted after 1509 cycles at 55% of the single cycle burst strength. Under the same cyclic loading at ambient temperature, the test results would predict failure in the reinforced plastic. The results of similar tests upon adhesively bonded polyimide aluminum-foil lined cylinders are also reviewed.-
The properties of organic adhesives were studied to acquire an adequate information base to generate a guideline document for the selection of adhesives for use in high reliability hybrid microcircuits. Specific areas covered include: (1) alternate methods for determining the outgassing of cured adhesives; (2) effects of long term aging at 150C on the electrical properties of conductive adhesives; (3) effects of shelf life age on adhesive characteristics; (4) bond strengths of electrically conductive adhesives on thick film gold metallization, (5) a copper filled adhesive; (6) effects of products outgassed from cured adhesives on device electrical parameters; (7) metal migration from electrically conductive adhesives; and (8) ionic content of electrically insulative adhesives. The tests performed during these investigations are described, and the results obtained are discussed in detail.
The properties of organic adhesives were investigated to acquire information for a guideline document regarding the selection of adhesives for use in high reliability hybrid microcircuits. Specifically, investigations were made of (1) alternate methods for determining the outgassing of cured adhesives, (2) effects of long term aging at 150 C on the electrical properties of conductive adhesives, (3) effects of shelf life age on adhesive characteristics, (4) bond strengths of electrically conductive adhesives on thick film gold metallization, (5) a copper filled adhesive, (6) effects of products outgassed from cured adhesives on device electrical parameters, (7) metal migration from electrically conductive adhesives, and (8) ionic content of electrically insulative adhesives. The tests performed during these investigations are described, and the results obtained are discussed.
Various surface preparations for titanium 6-4 alloy were studied. An anodizing method was investigated, and compared with the results of other chemical treatments, namely, phosphate/fluoride, Pasa-Jell and Turco. The relative durability of the different surface treatments was assessed by monitoring changes in surface chemistry and morphology occasioned by aging at 505 K (450 F). Basic electron spectroscopic data were collected for polyimide and polyphenylquinoxaline adhesives and synthetic precursors. Fractographic studies were completed for several combinations of adherend, adhesive, and testing conditions.
One of the most important criterion for acceptable commercial application of a multiple phase composition is uniformity and reproducibility. This means that the performance characteristics of the coat - e.g., its lubricating properties, bond strength to the substrate, and thermal properties - can be readily predicted to give a desired performance. The improvement of uniformity and reproducibility of the coats, the oxidation behavior at three temperature ranges, the effect of bond coat and the effect of preheat treatment as measured by adhesive strength tests, coating examination procedures, and physical property measurements were studied. The following modifications improved the uniformity and reproducibility: (1) changes and closer control in the particle size range of the raw materials used, (2) increasing the binder content from 3.2% to 4.1% (dried weight), and (3) analytical processing procedures using step by step checking to assure consistency.
A combined experimental-analytical investigation to characterize the cyclic failure mechanism of a simple composite-to-composite bonded joint is conducted. The cracked lap shear (CLS) specimens of graphite/epoxy adherend bonded with EC-3445 adhesive are tested under combined mode 1 and 2 loading. In all specimens tested, fatigue failure occurs in the form of cyclic debonding. The cyclic debond growth rates are measured. The finite element analysis is employed to compute the mode 1, mode 2, and total strain energy release rates (i.e., GI, GII, and GT). A wide range of mixed-mode loading, i.e., GI/GII ranging from 0.03 to 0.38, is obtained. The total strain energy release rate, G sub T, appeared to be the driving parameter for cyclic debonding in the tested composite bonded system.
An experimental investigation of adhesively bonded composite joint was conducted to characterize the debond growth mechanism under mode II static and fatigue loadings. For this purpose, end-notched flexure specimens of graphite/epoxy (T300/5208) adherends bonded with EC 3445 adhesive were tested. In all specimen tested, the fatigue failure occurred in the form of cyclic debonding. The present study confirmed the result of previous studies that total strain-energy-release rate is the driving parameter for cyclic debonding. Further, the debond growth resistance under cyclic loading with full shear reversal (i.e., stress ratio, R = -1) is drastically reduced in comparison to the case when subjected to cyclic shear loading with no shear reversal (i.e., R = 0.1).
Corrosion evaluation studies were conducted on 4130 alloy steel samples coated with electrodeposited zinc-nickel and samples coated with electrodeposited cadmium. The zinc nickel was deposited by the selection electrochemical metallizing process. These coated samples were exposed to a 5-percent salt fog environment at 35 plus or minus 2 C for a period ranging from 96 to 240 hours. An evaluation of the effect of dichromate coatings on the performance of each plating was conducted. The protection afforded by platings with a dichromate seal was compared to platings without the seal. During the later stages of testing, deposit adhesion and the potential for hydrogen entrapment were also evaluated.
A fabrication technique was successfully developed for a metallic aluminum honeycomb, high-accuracy, lightweight, and long-life solar concentrator (mirror) for Advanced Solar Dynamic Space Power Systems. The program scope was limited to the development, fabrication, evaluation, and delivery of a solar concentrator facet (petal) that was sized for a 2-meter deployable solar concentrator. A surface accuracy of 1.0 mrad was achieved. The development incorporated tooling design, material selection, facet forming, adhesive selection, testing, and analysis. Techniques for applying levelizing, reflective, and protective optical coatings were also developed.
Graphite fibers were heated in a vacuum to test the adhesion of deposited films at elevated temperatures. Copper-clad fibers and fibers with bilayer coatings were resistance heated by a direct-current power supply. Where possible, peak temperatures were measured with a long-focal-length optical pyrometer. Fiber surface wetting or nonwetting behavior could be clearly observed after this relatively quick and simple procedure. These results are discussed in the context of creating composites of graphite fibers in a copper matrix.
Adhesive bonding offers many advantages over mechanical fastening, but requires robust materials and processing methodologies before it can be incorporated in primary structures for aerospace applications. Surface preparation is widely recognized as one of the key steps to producing robust and predictable bonds. This report documents an ongoing investigation of a surface preparation technique based on Nd:YAG laser ablation as a replacement for the chemical etch and/or abrasive processes currently applied to Ti-6Al-4V alloys. Laser ablation imparts both topographical and chemical changes to a surface that can lead to increased bond durability. A laser based process provides an alternative to chemical-immersion, manual abrasion, and grit blast process steps which are expensive, hazardous, environmentally unfriendly, and less precise. In addition, laser ablation is amenable to process automation, which can improve reproducibility to meet quality standards for surface preparation. An update on work involving adhesive property testing, surface characterization, surface stability, and the effect of laser surface treatment on fatigue behavior is presented. Based on the tests conducted, laser surface treatment is a viable replacement for the immersion chemical surface treatment processes. Testing also showed that the fatigue behavior of the Ti-6Al-4V alloy is comparable for surfaces treated with either laser ablation or chemical surface treatment.
Explore the source record for details and available documents.
With upcoming missions to the Moon and beyond to Mars, it is increasingly imperative to elucidate the detrimental effects of space travel beyond the lower Earth orbit, particularly to galactic cosmic radiation. Additionally, with the first female astronaut to soon travel to the Moon there is a strong need to understand the biological sex differences to adaptation to the deep space environment. While the effects of spaceflight on the nervous system are not fully known, studies in animal models have shown that exposure to ionizing radiation can cause neuronal damage and lead to downstream cognitive and behavioral deficits. Here, we investigated the neurobehavioral responses to space environment-like radiation exposure. Male and female 23–24-week-old mice (age-matched to average astronaut age) were exposed to 5, 15 and 50 cGy via Five-Ion Galactic Cosmic Ray Simulation at the NASA National Space Radiation Laboratory at Brookhaven National Laboratory. Both early (72hrs post exposure) and late (1-4 months post exposure) cognitive and behavioral deficits were investigated. Early analysis was performed by observing in-cage behavior including frequency/duration of digging, rearing, and grooming and nestlet building. Additionally, late effects were analyzed at NASA Ames via in-cage behavior as well as Catwalk (gait), Zero Maze (anxiety), Adhesive Removal (sensory motor), Novel Object Recognition and Barnes Maze (working memory). There were pronounced sex differences in both early and late time points. Females scored better than males in nestlet building, gait and working memory while males scored better at the sensory motor (adhesive removal) test. Dose effects were primarily observed at 50 cGy for both sexes, particularly with the Barnes Maze (working memory), where both males and females exposed to 50 cGy showed little to no improvement in test performance, though females again performed better than males. Currently, we are investigating the correlations between the observed behavior and cytokine levels in the plasma and brain. Future studies will continue to investigate cognitive consequences of galactic cosmic radiation in combination with other space-like environment stressors, including antigravity and social versus single housing.
The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.
An extensive development and testing program on adhesive systems shows that: (1) A closed cell silicone rubber sponge bonded to substrates with thin bond lines of glass filled adhesive exhibits density and modulus values approximately one third that of solid silicone adhesives; (2) utilization of glass or phenolic microballoons as fillers in silicone adhesives reduces density but increases moduli of the vulcanized materials; (3) the silicone elastomer based adhesives appear to be complex systems rather than homogeneous, isotropic materials. Tensile, shear, and compression properties plotted versus temperature verify this conjecture; and (4) constant strain-stress relaxation tests on glass-filled adhesive show that stress relaxation is most pronounced near the glass transition temperature.
Test equipment modifications, and heat treatment of metal specimens for adhesion testing
The contracted activities for the procurement of 'Investigate Zero-Stress Replicated Optics' to support the AXAF-S x-ray spectrometer mirrors has been completed. To date four large Wolter I grazing incidence x-ray optical shells have been electroformed from nickel. The mirrors were fabricated utilizing each of two nickel alloy plated aluminum substrates twice. A wide variety of testing has been completed by NASA MSFC and UAH. This testing includes heat treatment control tests, subscale plating and fixture testing, alloy control of the electroless nickel, adhesion and release testing of the gold to electroless nickel, electroforming instrumentation and software and fabrication of subscale models. The full scale shells are one millimeter thick nickel electrodeposited over a thin gold layer which in turn has the optical surface on the inside. The optical surface is the replicate of the surface prepared on the substrate. Appendix I briefly outlines the fabrication process. Major objectives which were shared by UAH and MSFC include the design of facilities, equipment and tooling and procurement of materials and equipment. Process development followed with the fabrication of small scale pilot units. Procurement commenced immediately and equipment and materials were ordered to implement the fabrication of first surface full scale substrates (mandrels) and the second surface electroformed optical components. All principal objectives have been achieved. Inspection of the mirrors in visible and x-ray modes validates that the required performance and the quality can be achieved by an electroforming replication process. A very distinct progressive improvement has been achieved with each of the four mirrors produced. The final mirror exceeded the original goals and set an improved standard for flight hardware. The future goal of a 30 arc second resolution at 8 KEV x-ray appears to be achievable by this process when proper cleanliness and process control is utilized.