Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accountability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Case study: Accounting for response measurement error in fitting a regression model

This article presents a case study motivated by a plot of data that suggested an emerging trend that the authors were faced with explaining. When the measurement error of the data is accounted for, it turns out there was no real trend. Furthermore, this article shows how to use a Bayesian modeling approach to account for the measurement error.

42 ENGINEERING↗

Dislocation vs. production bias revisited with account of radiation-induced emission bias I. Void swelling under electron and light ion irradiation

Early experimental data on void swelling in electron-irradiated materials disagree with the dislocation bias models based on the dislocation-point defect elastic interactions. Later this became one of the reasons that prompted the development of models based on production bias (PBM) as the main driver for swelling, which assumed that the dislocation bias was much lower than that predicted by theory. However, the PBM in its present form fails to account for important and common observations: the indefinite void growth often observed under cascade irradiation and the swelling saturation observed under high dose irradiation and in void lattices. In this paper we show that these contradictions can be naturally resolved in the framework of the rate theory modified with account of the radiation-induced vacancy emission from extended defects, such as voids, dislocations and grain boundaries. The modified rate theory agrees well with the experimental data, which proves that original dislocation bias should be used in rate theory models in different irradiation. The modified theory predictions include (but not limited to) the radiation-induced annealing of voids, swelling saturation under high dose irradiation, generally, and in void lattices, in particular.

Dubinko, Volodymyr↗

ACCOUNTING FOR CALIBRATION UNCERTAINTIES IN X-RAY ANALYSIS: EFFECTIVE AREAS IN SPECTRAL FITTING

While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted values of model parameters. Accounting for such uncertainties currently requires extensive case-specific simulations if using existing analysis packages. Here, we present general statistical methods that incorporate calibration uncertainties into spectral analysis of high-energy data. We first present a method based on multiple imputation that can be applied with any fitting method, but is necessarily approximate. We then describe a more exact Bayesian approach that works in conjunction with a Markov chain Monte Carlo based fitting. We explore methods for improving computational efficiency, and in particular detail a method of summarizing calibration uncertainties with a principal component analysis of samples of plausible calibration files. This method is implemented using recently codified Chandra effective area uncertainties for low-resolution spectral analysis and is verified using both simulated and actual Chandra data. Our procedure for incorporating effective area uncertainty is easily generalized to other types of calibration uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

AN ACCOUNTING OF THE DUST-OBSCURED STAR FORMATION AND ACCRETION HISTORIES OVER THE LAST {approx}11 BILLION YEARS

We report on an accounting of the star-formation- and accretion-driven energetics of 24 {mu}m-detected sources in the Great Observatories Origins Deep Survey-North field. For sources having infrared (IR; 8-1000 {mu}m) luminosities {approx}>3 x 10{sup 12} L{sub sun} when derived by fitting local spectral energy distributions (SEDs) to 24 {mu}m photometry alone, we find these IR luminosity estimates to be a factor of {approx}4 times larger than those estimated when the SED fitting includes additional 16 and 70 {mu}m data (and in some cases mid-IR spectroscopy and 850 {mu}m data). This discrepancy arises from the fact that high-luminosity sources at z >> 0 appear to have far- to mid-IR ratios, as well as aromatic feature equivalent widths, typical of lower luminosity galaxies in the local universe. Using our improved estimates for IR luminosity and active galactic nucleus (AGN) contributions, we investigate the evolution of the IR luminosity density versus redshift arising from star formation and AGN processes alone. We find that, within the uncertainties, the total star-formation-driven IR luminosity density is constant between 1.15 {approx}< z {approx}< 2.35, although our results suggest a slightly larger value at z {approx}> 2. AGNs appear to account for {approx}<18% of the total IR luminosity density integrated between 0 {approx}< z {approx}< 2.35, contributing {approx}<25% at each epoch. Luminous infrared galaxies (LIRGs; 10{sup 11} L{sub sun} {<=} L{sub IR} < 10{sup 12} L{sub sun}) appear to dominate the star formation rate density along with normal star-forming galaxies (L{sub IR} < 10{sup 11} L{sub sun}) between 0.6 {approx}< z {approx}< 1.15. Once beyond z {approx}> 2, the contribution from ultraluminous infrared galaxies (L{sub IR} {>=} 10{sup 12} L{sub sun}) becomes comparable with that of LIRGs. Using our improved IR luminosity estimates, we find existing calibrations for UV extinction corrections based on measurements of the UV spectral slope typically overcorrect UV luminosities by a factor of {approx}2, on average, for our sample of 24 {mu}m-selected sources; accordingly we have derived a new UV extinction correction more appropriate for our sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of data collection taking radiation damage into account

Software implementing a new method for the optimal choice of data-collection parameters, accounting for the effects of radiation damage, is presented. To take into account the effects of radiation damage, new algorithms for the optimization of data-collection strategies have been implemented in the software package BEST. The intensity variation related to radiation damage is approximated by log-linear functions of resolution and cumulative X-ray dose. Based on an accurate prediction of the basic characteristics of data yet to be collected, BEST establishes objective relationships between the accessible data completeness, resolution and signal-to-noise statistics that can be achieved in an experiment and designs an optimal plan for data collection.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accounting for spectroscopic effects in laser‐based open‐path eddy covariance flux measurements

Abstract A significant portion of the production and consumption of trace gases (e.g. CO 2 , CH 4 , N 2 O, NH 3 , etc.) by world ecosystems occurs in areas without sufficient infrastructure or easily available grid power to run traditional closed‐path flux stations. Open‐path analyzer design allows such measurements with power consumption 10–150 times below present closed‐path technologies, helping to considerably expand the global coverage and improve the estimates of gas emissions and budgets, informing the remote sensing and modeling communities and policy decisions, all the way to IPCC reports. Broad‐band nondispersive infrared devices have been used for open‐path CO 2 and H 2 O measurements since the late 1970s, but since recently, a growing number of new narrow‐band laser‐based instruments are being rapidly developed. The new design comes with its own challenges, specifically: (a) mirror contamination, and (b) uncontrolled air temperature, pressure and humidity, affecting both the gas density and the laser spectroscopy of the measurements. While the contamination can be addressed via automated cleaning, and density effects can be addressed via the Webb‐Pearman‐Leuning approach, the spectroscopic effects of the in situ temperature, pressure and humidity fluctuations on laser‐measured densities remain a standing methodological question. Here we propose a concept accounting for such effects in the same manner as Webb et al. proposed to account for respective density effects. Derivations are provided for a general case of flux of any gas, examined using a specific example of CH 4 fluxes from a commercially available analyzer, and then tested using “zero‐flux” experiment. The proposed approach helps reduce errors in open‐path, enclosed, and temperature‐ or pressure‐uncontrolled closed‐path laser‐based flux measurements due to the spectroscopic effects from few percents to multiple folds, leading to methodological advancement and geographical expansion of the use of such systems providing reliable and consistent results for process‐level studies, remote sensing and Earth modeling applications, and GHG policy decision‐making.

Burba, George↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated treatment planning for a dedicated multi-source intra-cranial radiosurgery treatment unit accounting for overlapping structures and dose homogeneity

Purpose: The purpose of this work is to advance the two-step approach for Gamma Knife{sup ®} Perfexion™ (PFX) optimization to account for dose homogeneity and overlap between the planning target volume (PTV) and organs-at-risk (OARs).Methods: In the first step, a geometry-based algorithm is used to quickly select isocentre locations while explicitly accounting for PTV-OARs overlaps. In this approach, the PTV is divided into subvolumes based on the PTV-OARs overlaps and the distance of voxels to the overlaps. Only a few isocentres are selected in the overlap volume, and a higher number of isocentres are carefully selected among voxels that are immediately close to the overlap volume. In the second step, a convex optimization is solved to find the optimal combination of collimator sizes and their radiation duration for each isocentre location.Results: This two-step approach is tested on seven clinical cases (comprising 11 targets) for which the authors assess coverage, OARs dose, and homogeneity index and relate these parameters to the overlap fraction for each case. In terms of coverage, the mean V{sub 99} for the gross target volume (GTV) was 99.8% while the V{sub 95} for the PTV averaged at 94.6%, thus satisfying the clinical objectives of 99% for GTV and 95% for PTV, respectively. The mean relative dose to the brainstem was 87.7% of the prescription dose (with maximum 108%), while on average, 11.3% of the PTV overlapped with the brainstem. The mean beam-on time per fraction per dose was 8.6 min with calibration dose rate of 3.5 Gy/min, and the computational time averaged at 205 min. Compared with previous work involving single-fraction radiosurgery, the resulting plans were more homogeneous with average homogeneity index of 1.18 compared to 1.47.Conclusions: PFX treatment plans with homogeneous dose distribution can be achieved by inverse planning using geometric isocentre selection and mathematical modeling and optimization techniques. The quality of the obtained treatment plans are clinically satisfactory while the homogeneity index is improved compared to conventional PFX plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correcting radiation survey data to account for increased leakage during intensity modulated radiotherapy treatments

Purpose: Intensity modulated radiotherapy (IMRT) treatments require more beam-on time and produce more linac head leakage to deliver similar doses to conventional, unmodulated, radiotherapy treatments. It is necessary to take this increased leakage into account when evaluating the results of radiation surveys around bunkers that are, or will be, used for IMRT. The recommended procedure of applying a monitor-unit based workload correction factor to secondary barrier survey measurements, to account for this increased leakage when evaluating radiation survey measurements around IMRT bunkers, can lead to potentially costly overestimation of the required barrier thickness. This study aims to provide initial guidance on the validity of reducing the value of the correction factor when applied to different radiation barriers (primary barriers, doors, maze walls, and other walls) by evaluating three different bunker designs.Methods: Radiation survey measurements of primary, scattered, and leakage radiation were obtained at each of five survey points around each of three different radiotherapy bunkers and the contribution of leakage to the total measured radiation dose at each point was evaluated. Measurements at each survey point were made with the linac gantry set to 12 equidistant positions from 0° to 330°, to assess the effects of radiation beam direction on the results.Results: For all three bunker designs, less than 0.5% of dose measured at and alongside the primary barriers, less than 25% of the dose measured outside the bunker doors and up to 100% of the dose measured outside other secondary barriers was found to be caused by linac head leakage.Conclusions: Results of this study suggest that IMRT workload corrections are unnecessary, for survey measurements made at and alongside primary barriers. Use of reduced IMRT workload correction factors is recommended when evaluating survey measurements around a bunker door, provided that a subset of the measurements used in this study are repeated for the bunker in question. Reduction of the correction factor for other secondary barrier survey measurements is not recommended unless the contribution from leakage is separately evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-C-17A-06: Online Adaptive Re-Planning to Account for Independent Motions Between Multiple Targets During Radiotherapy of Lung Cancer

Purpose: To quantify interfractional independent motions between multiple targets in radiotherapy (RT) of lung cancer, and to study the dosimetric benefits of an online adaptive replanning method to account for these variations. Methods: Ninety five diagnostic-quality daily CTs acquired for 9 lung cancer patients treated with IGRT using an in-room CT (CTVision, Siemens) were analyzed. On each daily CT set, contours of the targets (GTV, CTV, or involved nodes) and organs at risk were generated by populating the planning contours using an auto-segmentation tool (ABAS, Elekta) with manual editing. For each patient, an IMRT plan was generated based on the planning CT with a prescription dose of 60 Gy in 2Gy fractions. Three plans were generated and compared for each daily CT set: an IGRT (repositioning) plan by copying the original plan with the required shifts, an online adaptive plan by rapidly modifying the aperture shapes and segment weights of the original plan to conform to the daily anatomy, and a new fully re-optimized plan based on the daily CT using a planning system (Panther, Prowess). Results: The daily deviations of the distance between centers of masses of the targets from the plans varied daily from -10 to 8 mm with an average −0.9±4.1 mm (one standard deviation). The average CTV V100 are 99.0±0.7%, 97.9±2.8%, 99.0±0.6%, and 99.1±0.6%, and the lung V20 Gy 928±332 cc, 944±315 cc, 917±300 cc, and 891±295 cc for the original, repositioning, adaptive, and re-optimized plans, respectively. Wilcoxon signed-rank tests show that the adaptive plans are statistically significantly better than the repositioning plans and comparable with the reoptimized plans. Conclusion: There exist unpredictable, interfractional, relative volume changes and independent motions between multiple targets during lung cancer RT which cannot be accounted for by the current IGRT repositioning but can be corrected by the online adaptive replanning method.

60 APPLIED LIFE SCIENCES↗

Introduction of corrections taking into account interdependence of multigroup constants to the results of multigroup perturbation theory calculations

In multigroup calculations of reactivity and sensitivity coefficients, methodical errors can appear if the interdependence of multigroup constants is not taken into account. For this effect to be taken into account, so-called implicit components of the aforementioned values are introduced. A simple technique for computing these values is proposed. It is based on the use of subgroup parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New method for taking into account radiative events in the MOLLER inclusive experiment

A new method (N-method) for taking into account radiative events in inclusive polarized experiments that, in principle, makes no use of an unphysical separation into soft-and hard-photon regions is demonstrated. A procedure for taking into account bremsstrahlung in theMOLLER forthcoming ultraprecise experiment at the Thomas Jefferson Laboratory is developed on the basis of this method. The algorithm of the method is described in detail, and the results obtained by means of the N method are compared with the results of applying traditional methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Revisiting Statistical Aspects of Nuclear Material Accounting

Nuclear material accounting (NMA) is the only safeguards system whose benefits are routinely quantified. Process monitoring (PM) is another safeguards system that is increasingly used, and one challenge is how to quantify its benefit. This paper considers PM in the role of enabling frequent NMA, which is referred to as near-real-time accounting (NRTA). We quantify NRTA benefits using period-driven and data-driven testing. Period-driven testing makes a decision to alarm or not at fixed periods. Data-driven testing decides as the data arrives whether to alarm or continue testing. The difference between period-driven and datad-riven viewpoints is illustrated by using one-year and two-year periods. For both one-year and two-year periods, period-driven NMA using once-per-year cumulative material unaccounted for (CUMUF) testing is compared to more frequent Shewhart and joint sequential cusum testing using either MUF or standardized, independently transformed MUF (SITMUF) data. We show that the data-driven viewpoint is appropriate for NRTA and that it can be used to compare safeguards effectiveness. In addition to providing period-driven and data-driven viewpoints, new features include assessing the impact of uncertainty in the estimated covariance matrix of the MUF sequence and the impact of both random and systematic measurement errors.

Burr, T.↗

Accuracy of genomic prediction in switchgrass ( Panicum virgatum L.) improved by accounting for linkage disequilibrium

Switchgrass is a relatively high-yielding and environmentally sustainable biomass crop, but further genetic gains in biomass yield must be achieved to make it an economically viable bioenergy feedstock. Genomic selection (GS) is an attractive technology to generate rapid genetic gains in switchgrass, and meet the goals of a substantial displacement of petroleum use with biofuels in the near future. In this study, we empirically assessed prediction procedures for genomic selection in two different populations, consisting of 137 and 110 half-sib families of switchgrass, tested in two locations in the United States for three agronomic traits: dry matter yield, plant height, and heading date. Marker data were produced for the families’ parents by exome capture sequencing, generating up to 141,030 polymorphic markers with available genomic-location and annotation information. We evaluated prediction procedures that varied not only by learning schemes and prediction models, but also by the way the data were preprocessed to account for redundancy in marker information. More complex genomic prediction procedures were generally not significantly more accurate than the simplest procedure, likely due to limited population sizes. Nevertheless, a highly significant gain in prediction accuracy was achieved by transforming the marker data through a marker correlation matrix. Our results suggest that marker-data transformations and, more generally, the account of linkage disequilibrium among markers, offer valuable opportunities for improving prediction procedures in GS. Furthermore, some of the achieved prediction accuracies should motivate implementation of GS in switchgrass breeding programs.

59 BASIC BIOLOGICAL SCIENCES↗

Double-Difference Tomography for Sequestration MVA [monitoring, verification, and accounting]

Analysis of synthetic data was performed to determine the most cost-effective tomographic monitoring system for a geologic carbon sequestration injection site. Double-difference tomographic inversion was performed on 125 synthetic data sets: five stages of CO2 plume growth, five seismic event regions, and five geophone arrays. Each resulting velocity model was compared quantitatively to its respective synthetic velocity model to determine an accuracy value. The results were examined to determine a relationship between cost and accuracy in monitoring, verification, and accounting applications using double-difference tomography. The geophone arrays with widely-varying geophone locations, both laterally and vertically, performed best. Additionally, double difference seismic tomography was performed using travel time data from a carbon sequestration site at the Aneth oil field in southeast Utah as part of a Department of Energy initiative on monitoring, verification, and accounting (MVA) of sequestered CO2. A total of 1,211 seismic events were recorded from a borehole array consisting of 22 geophones. Artificial velocity models were created to determine the ease with which different CO2 plume locations and sizes can be detected. Most likely because of the poor geophone arrangement, a low velocity zone in the Desert Creek reservoir can only be detected when regions of test site containing the highest ray path coverage are considered. MVA accuracy and precision may be improved through the use of a receiver array that provides more comprehensive ray path coverage.

47 OTHER INSTRUMENTATION↗

Bio-Carbon Accounting for Bio-Oil Co-Processing: 14 C and 13 C/ 12 C

This is a powerpoint presentation on bio-carbon accounting for bio-oil co-processing. Because of the overlapping range in the stable C isotope compositions of fossil oils and biooils from C3-type feedstocks, it is widely thought that stable isotopes are not useful to track renewable carbon during co-production. In contrast, our study demonstrates the utility of stable isotopes to: • capture a record of renewable carbon allocation between FCC products of co-processing • record changes in carbon apportionments due to changes in reactor or feed temperature Stable isotope trends as a function of percent bio-oil in the feed are more pronounced when the δ 13 C of the bio-oil endmember differs greatly from the VGO (i.e., it has a C4 biomass source–corn stover, switch grass, Miscanthus, sugarcane– versus a C3 biomass source– pine, wheat, rice, potato), but trends on the latter case are significant for endmember differences of just a few permil. The correlation between measured 14 C and δ 13 C may be useful as an alternative to carbon accounting, but the relationship must first be established for different bio-oil sources.

09 BIOMASS FUELS↗

Accounting Methodology for Source Energy of Non-Combustible Renewable Electricity Generation

As non-combustible sources of renewable power (wind, solar, hydro, and geothermal) do not consume fuel, the “source” (or “primary”) energy from these sources cannot be accounted for in the same manner as it is for fossil fuel sources. The methodology chosen for these technologies is important as it affects the perception of the relative size of renewable source energy to fossil energy, affects estimates of source-based building energy use, and overall source energy based metrics such as energy productivity. This memo reviews the methodological choices, outlines implications of each choice, summarizes responses to a request for information on this topic, and presents guiding principles for the U.S. Department of Energy, (DOE) Office of Energy Efficiency and Renewable Energy (EERE) to use to determine where modifying the current renewable source energy accounting method used in EERE products and analyses would be appropriate to address the issues raised above.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Social Media Account Resolution and Verification

In this SAND report, we discuss various authorship attribution techniques for social media platforms to identify separate accounts controlled by one user. We look at three main categories of techniques: stylometric, semantic, and temporal, and we test several algorithms in each category. We then combine these techniques to increase predictive power, and perform cross-platform account verification on Twitter and Stack Exchange datasets. Additionally, we briefly examine graphical techniques, and analyze the predictive power of unsupervised approaches. Finally, we apply our techniques to unbalanced data sets. Our experiments reveal that normalized compression distance shows great promise in analyzing social media.

97 MATHEMATICS AND COMPUTING↗