Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Experimental Generation of Extreme Electron Beams for Advanced Accelerator Applications

In this Letter, we report on the experimental generation of high energy (10 GeV), ultrashort (femtosecond-duration), ultrahigh current (∼ 0.1 MA), petawatt peak power electron beams in a particle accelerator. These extreme beams enable the exploration of a new frontier of high-intensity beam-light and beam-matter interactions broadly relevant across fields ranging from laboratory astrophysics to strong field quantum electrodynamics and ultrafast quantum chemistry. We demonstrate our ability to generate and control the properties of these electron beams by means of a laser-electron beam shaping technique. In conclusion, this experimental demonstration opens the door to on-the-fly customization of extreme beam current profiles for desired experiments and is poised to benefit a broad swath of cross-cutting applications of relativistic electron beams.

43 PARTICLE ACCELERATORS↗

Uncertainty Aware Deep Learning for Fault Prediction Using Multivariate Time Series Signals

The superconducting radio-frequency cavities are a crucial component of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. When a cavity faults, beam delivery to experimental end users is disrupted. Prediction of cavity faults prior to onset is essential to reduce operation and maintenance costs. In this work, a parallel long short-term memory (LSTM)-convolution neural network (CNN)-based deep learning (DL) model is proposed to predict impending faults using pre-fault signals. Further, we introduce an uncertainty quantification approach using Monte Carlo dropout with the LSTM-CNN model to ascertain confidence in the prediction. The model was tested using multivariate time series signals from stable cavity operations and before faults. Initial results show that on the test dataset, the model can identify impending faults before their onset with an average 10-fold cross validation accuracy of 97.39% and a standard deviation of 0.12% using a 100-ms time window. It is also observed that the model performs better as the prediction time moves closer to the fault onset. For additional context, we compare the performance of the model with three machine-learning-based (ML) fault prediction models. Our proposed parallel LSTM-CNN-based DL method shows better performance than the ML-based methods.

Rahman, Md Monibor↗

Measurement of the EMC Effect of the Helium-3 Nucleus at Jefferson Lab

The MARATHON (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A=3 EMC Effect in Deep Inelastic Scattering Off the Tritium and Helium MirrOr Nuclei) experiment ran in the Hall A Facility of the Thomas Jefferson National Accelerator Facility (JLab). The experiment used a 10.59 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) of JLab to measure the ratio of the F2 structure functions of Helium-3 and Deuterium. Data were taken in the kinematic range of 0.195 lte x lte 0.825, 2.5 (GeV/c)2 lte Q2 lte 13 (GeV/c)2, and 3.5 (GeV/c2)^2 lte W^2 lte 13 (GeV/c2)^2. This is the first measurement of the 3He EMC effect that is purely in the Deep Inelastic Scattering region. The results of this experiment constitute an important, complimentary addition, to the limited data presently available for the EMC effect of light nuclei. The MARATHON results are compared to the world data for light, medium, and heavy nuclei. This measurement is considered an essential component to uncovering the nature of the EMC effect.

Hague, Tyler↗

A STUDY OF SHORT-RANGE CORRELATED PAIR FORMATION MECHANISMS

Short-Range Correlations (SRCs) refers to pairs of nucleons that are temporary high density fluctuations with high relative momenta and lower center-of-mass momenta com pared to the nuclear Fermi momentum (kF). SRCs account for 20–25% of the nucleons in medium to heavy nuclei, make up essentially all nucleons with momentum greater than kF, and contribute most of the kinetic energy carried by nucleons in nuclei. The existing semi-inclusive and exclusive measurements only cover a handful of light nu clei or heavy elements. This does not allow for a systematic study of the dependence of SRC pairs on nuclear mass and proton-neutron asymmetry. It also does not allow for insights into SRC pairing mechanisms. Therefore, we systematically studied the individual probabilities for finding SRC protons in symmetric and neutron-rich asymmetric nuclei d, 9Be, 10B, 11B, 12C, 40Ca, 48Ca, 54Fe, and 197Au. We measured the (e,e'p) reaction in kinematics dominated by scattering off mean-field nucleons (k = kF) and nucleons in SRC pairs (k = kF) at the Thomas Jefferson National Accelerator Facility (JLab) in Hall C of the Continuous Electron Beam Accelerator Facility (CEBAF) in the Fall of 2022. The measured results were used to determine the SRC pairing probabilities for protons to examine how pairing depends on nuclear mass, proton-neutron asymmetry, and nuclear shell structure. The extracted cross-section ratios were also compared to theoretical calculations. We found that SRC pair formation depends more on the nuclear shell structure with sharp increases locally within the general trend of a slower increase with larger A. We also found that intra-shell pairing has a much larger influence than inter-shell pairing. Comparisons to theory suggest that angular momentum selection rules are important to SRC pair formation and can provide new constraints for new theoretical models.

Swan, Noah [Old Dominion Univ., Norfolk, VA (Unite↗

Exploring Causes of Beam Loss at CEBAF

At Jefferson Lab, the Continuous Electron Beam Accelerator (CEBAF) features a unique design with two linear accelerators and two arc sections allowing for multiple turns of the electron beam, as well as four experimental end stations. This topology leads to increased beam losses, especially in the spreader and recombiner regions connecting the arcs to the linacs and in the extraction regions connecting the experimental end stations to the accelerator. These losses result in equipment activation and operational interruptions. Recent upgrades to the facility’s diagnostic systems, including the addition of xenon ion chambers, have provided higher-resolution data regarding these loss events. Building on this improved observational capability, we are developing a simulation framework using optics codes and the Geant4-based BDSIM to model beam extinction and halo formation in these regions. This work aims to correlate simulation results with experimental data to isolate the causes of beam loss and inform future machine tuning strategies. We present a summary of conclusions drawn from recent operational studies and outline a plan to model the beam loss and validate the simulations.

Matthews, C. [Old Dominion Univ., Norfolk, VA (Uni↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

Simulations of positron injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130‑370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The simulation results for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are presented, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, <1 mm bunch length and normalized emittance of <100 mm mrad). The impact of target thickness, drive electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated.

Accelerator Physics↗

High Power Solid Target for Positron Source at CEBAF

The progress in the development of a polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is presented. The polarized positron beam is generated by a high current polarized electron beam (>1 mA @ 120 MeV) via bremsstrahlung radiation and e+e- pair production in the tungsten target. The simulations show that using an optimized target and positron beamline, the positron injector can provide a cw positron beam with a current larger than 50 nA and a polarization as large as 60%. Injected into the North Linac of CEBAF at an energy of 123 MeV, the positron beam can reach a maximum energy of 12 GeV to perform a rich experimental program. The results of the thermal and structural FEA analysis of the heat load in the target are presented, as well as the simulation results of radiation damage in the target. The performed and planned target material fatigue and radiation damage tests are discussed. This work is supported by the U.S. DOE, Office of Science, Office of Nuclear Physics, Contract No. DE-AC05-06OR23177 and the European Union?s Horizon 2020 research and innovation program under grant agreement No. 824093.

Ushakov, Andriy↗

Status of conceptual horizontal splitter design for FFA@CEBAF energy upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. Horizontal splitters are needed to control the beam parameters through these FFA arcs. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

CEBAF Injector for K Long Beam Conditions

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab concurrently operates four experimental Halls with distinct bunch charge specifications and repetition rates. Numerous critical beam parameters within CEBAF are configured in the injector, some remaining unchanged throughout the accelerator. Consequently, the injector plays a crucial role in determining final beam characteristics, including bunch structure, beam sizes, bunch lengths, energy spread, and beam transmission. The Jefferson Lab KL experiment is scheduled to take place at CEBAF in Hall D, featuring a much lower bunch repetition rate of 7.80 MHz or 15.59 MHz, below the nominal values of 249.5 MHz or 499 MHz. Although the proposed average current of 5 ?A or 10 ?A is low compared to the maximum CEBAF cur- rent of approximately 180 ?A, the corresponding bunch charge is unusually high for CEBAF injector operation. This study focuses on the behavior of low-repetition-rate, high-bunch- charge (0.32 to 0.64 pC) beams in the CEBAF injector. We investigated the evolution and transmission of low-charge beams to space-charge dominated high-charge beams in the front end of the CEBAF injector for two configurations: the pre-existing CEBAF Phase 1 injector upgrade, operated at 130 kV, and the existing CEBAF Phase 2 injector upgrade, operated at 140 kV, 180 kV, and to be operated at 200 kV. The electron beam through the CEBAF injector is characterized using beam dynamics simulations and comparisons with the available measurements performed at 130 kV. Multi-objective genetic optimizations of the CEBAF injector were performed to determine the operating magnetic elements and RF settings for the evolution and transmission of low, moderate, and high charge beams in the CEBAF injector at 180 kV and 200 kV DC gun voltages. Subsequently, simulations at the same voltages were conducted to obtain the beam characteristics at the front end of the CEBAF injector. The laser spot size and laser pulse length at the cathode were varied to observe their effects on beam transmission in the injector at different voltages (130 kV, 180 kV, and 200 kV). Experimental studies at 130 kV, 140 kV, and 180 kV validate the simulations. Beam study measurements are carried out using EPICS tools, while optimizations and simulations are facilitated by General Particle Tracer. Based on the findings, optimal parameters for the upcoming Jefferson Lab KL experiment are proposed, utilizing a lower repetition rate and higher bunch charge

Pokharel, Sunil↗

Acceleration of heavy ions in inverse free electron laser

In conventional linear accelerators, the beam is accelerated with a synchronous harmonic of the radio frequency field where the electric field component is collinear with the beam direction. This approach requires the design of complex accelerating structures, especially for low-energy heavy ions. If the beam motion were sustainably coupled to transverse electromagnetic fields, this could significantly simplify the accelerating structure design, and even allow acceleration with free-space waves. However, despite the long history of the proposed concept for accelerating low-velocity ion beams, it has not found practical application, partially because of the complexity of the technical design. In this paper, we present a practical design approach for this undulator-based accelerator for low-energy heavy-ions, reminiscent of the inverse free electron laser operating principle, but in a different parameter space.

47 OTHER INSTRUMENTATION↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

Explainable Graph Learning for Particle Accelerator Operations

Particle accelerators are vital tools in physics, medicine, and industry, requiring precise tuning to ensure optimal beam performance. However, real-world deviations from idealized simulations make beam tuning a time-consuming and error-prone process. In this work, we propose an explanation-driven framework for providing actionable insight into beamline operations, with a focus on the injector beamline at the Continuous Electron Beam Accelerator Facility (CEBAF). We represent beamline configurations as heterogeneous graphs, where setting nodes represent elements that human operators can actively adjust during beam tuning, and reading nodes passively provide diagnostic feedback. To identify the most influential setting nodes responsible for differences between any two beamline configurations, our approach first predicts the resulting changes in reading nodes caused by variations in settings, and then learns importance scores that capture the joint influence of multiple setting nodes. Experimental results on real-world CEBAF injector data demonstrate the framework’s ability to generate interpretable insights that can assist human operators in beamline tuning and reduce operational overhead.

Wang, Song [Univ. of Virginia, Charlottesville, VA↗

First demonstration of a triton beam using target normal sheath acceleration

Tritiated titanium targets were irradiated by the short-pulse OMEGA EP laser (1.25 kJ, 10 ps) to generate a laser accelerated pulsed beam of tritons by target normal sheath acceleration. Using a Thomson parabola, the beam was found to contain 10 12 tritons per pulse, with a mean energy of 2.2 MeV and an exponential tail reaching up to 10 MeV. In a separate experiment, the triton beam was directed onto a secondary deuterated polyethylene (CD) target to induce deuterium–tritium (D–T) nuclear reactions. Using neutron time-of-flight spectrometers, approximately 10 8 D–T fusion neutrons were observed per laser pulse. Furthermore, this triton beam presents new research opportunities for the study of the 3 H(t, 2n) 4 He reaction and di-neutron transfers to lithium and beryllium that may produce exotic neutron-rich nuclei of interest to basic nuclear science, astrophysics, and inertial confinement fusion technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗