Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “YAg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

Both technical and simulation progress has been made toward implementing a laser inverse Compton scattering diagnostic on the DIII-D tokamak. This is a novel diagnostic which uses a short (sub-ns) pulse laser together with a fast (sub-ns) gated x-ray detector to measure relativistic electrons inside a tokamak plasma. The study of these relativistic electrons is important to make sure they can be removed from any tokamak-based power reactor, as they could damage vessel walls and cooling lines. This diagnostic is completely new for magnetic fusion research and has never been implemented before on a tokamak. It is found that good signals and radial profiles could be obtained with an optimized high-energy (7 Joule) laser. Using a standard off-the-shelf Nd:YAG (0.7 Joule) laser would give some signals above the noise but no ability to measure the relativistic electron radial profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Segregation of Chromium and Titanium in Sapphire Optical Fiber Grown via the Laser-Heated Pedestal Growth Technique

Our research involves growth of single crystal (SC) optical fibers to be used for sensing applications in harsh environments. Silica optical fibers are an affordable and reliable option for a wide variety of applications including optical fiber sensors and fiber lasers. However, for applications in harsh environments, such as high temperatures, radioactivity, corrosivity, etc., silica fibers are not suitable due to their instability under such conditions. Fibers composed of SC materials such as sapphire and YAG are mechanically, chemically, and thermally more robust to harsh conditions, and thus are more appropriate for sensing applications in environments such as nuclear reactors, jet engines, and boiler. However, SC fibers grown via the laser-heated pedestal growth (LHPG) technique do not intrinsically have a functional cladding layer. A cladding layer is required to reduce the modal volume for distributed sensing applications, to reduce frustrated total internal reflection induced by surface contact of the fiber in certain applications, and to improve transmissivity. Our lab investigates introduction of dopant materials during LHPG to induce an effective core-cladding structure while maintain the crystallinity of the host material. This process results in optical fiber that is not only robust to harsh environments, but also has improved optical properties for distributed sensor applications.

distributed sensing↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

Plasma Emission, Wave Speeds, and Temperatures of Laser-Supported Plasmas in Air

A study of the generation and subsequent expansion of plasmas using a single beam (532 nm) from the second harmonic generator of a Q-switched Nd:YAG laser is described. The plasmas in air are studied using an intensified charge-coupled device camera over periods of 1000 ns following the laser pulses. The plasma experimental results are interpreted in terms of wave speeds and plasma temperatures. Energy balance equations are considered to estimate the plasma temperatures and the laser-supported radiation (LSR) and the laser-supported detonation (LSD) wave speeds. Within 1000 ns observation time, the circular spectral images turn elliptical because of plasma expansion toward the laser beam. The plasma expansion increases with increasing laser irradiance. A laser irradiance range of [Formula: see text] yields LSR wave speeds between 45 and 170 km/s and LSD wave speeds of 90–130 km/s. The measured wave speeds are compared with the LSR and the LSR wave speed models. The plasma temperatures are between 90,000 and 120,000 K at 15 ns after the laser pulse based on measured emission spectra and are between 640,000 and 760,000 K at 3 ns based on the LSR model.

Engineering↗

Hypersonic Wake Velocity Measurements Using Acetone Molecular Tagging Velocimetry

A non-intrusive laser diagnostic known as molecular tagging velocimetry was used to find quantitative off-body velocity measurements in the wake of a sphere in the Mach 7 Ludwieg Tube Wind Tunnel located at The University of Texas at San Antonio. Acetone gas seeded in the flow was excited using the 4th harmonic of a pulse-burst Nd:YAG laser. The experimental results were used to validate and compare to simulations using a continuous Galerkin flow solver. Both the experimental and simulated results agreed on negative velocities in the viscous shear layer. Near the centerline of the sphere, average velocities of -200 m/s were observed due to reverse flow in the recirculation region. Outside of the shear layer, velocities of 800 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight case was estimated to be ±27 m/s. The flow features of the wake were visualized using schlieren imaging, and the experimental results agreed well with the simulated results.

Shoemake, Lawton↗

First Results from the Thomson Scattering Diagnostic on the Large Plasma Device

We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.

Kaloyan, Marietta (ORCID:0000000182593038)↗

New Solids in As-O-Mo, As(P)-O-Mo(W) and As(P)-O-Nb(W) Systems That Exhibit Nonlinear Optical Properties

Interactions between well-mixed fine powders of As 2 O 3 , P 2 O 5 , MoO 3 , WO 3 and Nb 2 O 5 at different stoichiometry in quartz ampoules under vacuum at ~1000 °C in the presence of metallic molybdenum (or niobium), over several weeks, led to shiny dichroic crystalline materials being formed in cooler parts of the reaction vessel. An addition of small quantities of metals-Mo or Nb-was made with the aim of partially reducing their highly oxidized Mo(VI), W(VI) or Nb(V) species to corresponding Mo(V), W(V) and Nb(IV) centers, in order to form mixed valence solids. Sublimed crystals of four new compounds were investigated using a variety of techniques, with prime emphasis on the X-ray analysis, followed by spectroscopy (diffusion reflectance, IR, Raman and EPR), second harmonic generation (SHG), thermal analysis under N 2 and air atmosphere, and single crystals electrical conductivity studies. The results evidenced the formation of new complex solids of previously unknown compositions and structures. Three out of four compounds crystallized in non-centrosymmetric space groups and represent layered 2D polymeric puckered structures that being stacked on each other form 3D lattices. All new solids exhibit strong second-harmonic-generation (SHG effect; based on YAG 1064 nm tests with detection of 532 nm photons), and a rare photosalient effect when crystals physically move in the laser beam. Single crystals’ electrical conductivity of the four new synthesized compounds was measured, and the results showed their semiconductor behavior. Values of band gaps of these new solids were determined using diffusion reflectance spectroscopy in the visible region. Aspects of new solids’ practical usefulness are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Sub-Nanosecond, Room-Temperature, Mid-IR Fe:ZnSe Gain-Switched Laser: Experimental Characterization and Modeling

We present the modeling and experimental characterization of a room-temperature, sub-nanosecond, gain-switched (GS) Fe:ZnSe laser operating at 4.4–4.8 μm. As pump sources, we used a 2.79 µm Q-switched Cr:Er:YSGG laser with a pulse duration of 52 ns and the 2.98 μm idler of a Nd:YAG pumped KTA-OPO system with a pulse duration of 9 ns. The shortest pulse durations were measured to be 1.4 ns and 0.7 ns under excitation by the Cr:Er:YSGG laser and KTA-OPO system, respectively. The developed Fe:ZnSe laser model showed good agreement with the experimental results. Optimization of the laser parameters based on model simulations suggests that an Fe:ZnSe microchip laser configuration could be achieved with a pulse duration of ~250 ps and an efficiency of ~20%.

Ghimire, Saugat↗

Toward Revealing Microcystin Distribution in Mouse Liver Tissue Using MALDI-MS Imaging

Cyanotoxins can be found in water and air during cyanobacterial harmful algal blooms (cHABs) in lakes and rivers. Therefore, it is very important to monitor their potential uptake by animals and humans as well as their health effects and distribution in affected organs. Herein, the distribution of hepatotoxic peptide microcystin-LR (MC-LR) is investigated in liver tissues of mice gavaged with this most common MC congener. Preliminary matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging experiments performed using a non-automated MALDI matrix deposition device and a MALDI-time-of-flight (TOF) mass spectrometer yielded ambiguous results in terms of MC-LR distribution in liver samples obtained from MC-LR-gavaged mice. The tissue preparation for MALDI-MS imaging was improved by using an automated sprayer for matrix deposition, and liver sections were imaged using an Nd:YAG MALDI laser coupled to a 15 Tesla Fourier-transform ion cyclotron resonance (FT-ICR)-mass spectrometer. MALDI-FT-ICR-MS imaging provided unambiguous detection of protonated MC-LR (calculated m/z 995.5560, z = +1) and the sodium adduct of MC-LR (m/z 1017.5380, z = +1) in liver sections from gavaged mice with great mass accuracy and ultra-high mass resolution. Since both covalently bound and free MC-LR can be found in liver of mice exposed to this toxin, the present results indicate that the distribution of free microcystins in tissue sections from affected organs, such as liver, can be monitored with high-resolution MALDI-MS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Combined Experimental/Numerical Study of the Soot Formation Process in a Gasoline Direct-Injection Spray in the Presence of Laser-Induced Plasma Ignition

Here, combustion issued from an eight-hole, direct-injection spray was experimentally studied in a constant-volume pre-burn combustion vessel using simultaneous high-speed diffused back-illumination extinction imaging (DBIEI) and OH* chemiluminescence. DBIEI has been employed to observe the liquid-phase of the spray and to quantitatively investigate the soot formation and oxidation taking place during combustion. The fuel-air mixture was ignited with a plasma induced by a single-shot Nd:YAG laser, permitting precise control of the ignition location in space and time. OH* chemiluminescence was used to track the high-temperature ignition and flame. The study showed that increasing the delay between the end of injection and ignition drastically reduces soot formation without necessarily compromising combustion efficiency. For long delays between the end of injection and ignition (1.9 ms) soot formation was eliminated in the main downstream charge of the fuel spray. However, poorly atomized and large droplets formed at the end of injection (dribble) eventually do form soot near the injector even when none is formed in the main charge. The quantitative soot measurements for these spray and ignition scenarios, resolved in time and space, represents a significant new achievement. Reynolds-averaged Navier-Stokes (RANS) simulations were performed to assess spray mixing and combustion. An analysis of the predicted fuel-air mixture in key regions, defined based upon experimental observations, was used to explain different flame propagation speeds and soot production tendencies when varying ignition timing. The mixture analysis indicates that soot production can be avoided if the flame propagates into regions where the equivalence ratio (Φ) is already below 2. Reactive RANS simulations have also been performed, but with a poor match against the experiment, as the flame speed and heat-release rate are largely over estimated. This modeling weakness appears related to a very high level of turbulent viscosity predicted for the high-momentum spray in the RANS simulations, which is an important consideration for modeling ignition and flame propagation in mixtures immediately created by the spray.

42 ENGINEERING↗

Corrosion Behavior of Laser-Interference Structured AA2024 Coated with a Chromate-Containing Epoxy Primer

In this study, the corrosion behavior of laser-interference treated AA2024-T3 specimens, which are coated with a primer, is presented. The surface of as-received AA2024-T3 specimens were laser-interference structured by splitting the primary beam of a Q-switched Nd:YAG pulsed nanosecond laser into two beams and focusing them to the same spot on the specimen surface. After being stored in plastic cases for up to 70 d, without any additional cleaning, the specimens were spray painted with a chromate-containing epoxy primer, CA7233, compliant to MIL-PRF-23377 Type I Class C2 specification. The corrosion behavior of laser-interference specimens was assessed against that of specimens prepared by chromated conversion coating and sulfuric acid anodizing treatments. After the ASTM B117 corrosion exposure, it was found that the laser processed specimens exhibited only few blisters. On one hand, most specimens prepared at a laser fluence of 1.78 J/cm 2 , without any additional chemical cleaning, were found to develop one very small blister after only 96 h of exposure. However, the growth of these blisters was not significant even after 1,000 h of salt spray exposure. On the other hand, only a fraction of the specimens prepared at a laser fluence of 1.24 J/cm 2 and acetone wiped right after the laser structuring were found to develop several tiny blisters after 790 h and longer exposure. Overall, it was found that the corrosion damage was minimized at a laser rastering speed of 4 mm/s, a condition for which only 33% of specimens developed very minor corrosion damage. Furthermore, the ASTM D1654 creepage ratings, which was used to evaluate the corrosion damage along the scribe lines, were found to be at least nine for all coated panels. These results indicate that the laser-interference technique with the additional acetone wiping has the potential to be further developed as a nonchemical surface preparation technique for chromate-containing epoxy primers coating systems.

36 MATERIALS SCIENCE↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

PRODUCTION OF GLASS-TO-METAL SEALS USING ADDITIVE MANUFACTURING TECHNIQUES

Glass-to-metal (GtM) seals are hermetic barriers between glass and metal components, often used in the electronic and vacuum industries. Creating the seals traditionally requires heating all the components to the glass melting temperature, where the glass will flow and bond to the metal. Due to the manufacturing constraints of the individual components and sealing conditions there are geometric and material restrictions. Additive manufacturing techniques were used to make GtM seals to reduce these restrictions. Hermetic, single pin seals were produced using printed metal shells, by selective laser melting (SLM), and digital light processing (DLP) printed glass preforms. Glass preforms were printed with photosensitive resin mixed with a silicate sealing glass powder in a 1:2 weight ratio. Thermal analysis, TGA/DSC, and screening experiments were used to determine an organic removal schedule. Video techniques determined a sintering schedule by producing a densification curve at different isothermal holds which were fit with a viscous sintering model. Single pin seals were also produced use a laser assisted manufacturing (LAM) process as an alternative to the conventional furnace sealing process. A Nd:YAG laser was focused on a solid glass preform, heating the glass to form the glass-metal bond. The sealing glass was doped with a transition metal oxide, Fe2O3 or CuO, to increase absorption of the laser wavelength. The interface of hermetic LAM seals were analyzed using electron microscopy, compared to conventional prepared seals, finding a reduction of interfacial morphologies.

Read, Aaron Reece↗

Microstructure geometry for thermal barrier coatings to mitigate CMAS attack

Thermal barrier coatings and methods to make such coatings present improved resistance to CMAS infiltration. The method for forming a thermal barrier coating includes applying a layer of the thermal barrier coating to a component having a surface, forming a plurality of first channels in the thermal barrier coating, and forming a plurality of second channels in the thermal barrier coating. The first channels extend through a thickness of the thermal barrier coating from an interface with the surface of the component to a free surface opposite the interface. The second channels are disposed between the free surface and the interface and extending lengthwise generally parallel to the free surface of the thermal barrier coating, wherein the thermal barrier coating comprises a material comprising yttrium aluminum garnet (YAG) or yttria stabilized zirconia (YSZ).

Jordan, Eric↗

Dopant Segregation in Single-Crystal Optical Fiber Grown via the Laser-Heated Pedestal Growth Technique

Single crystal (SC) optical fiber has promising potential to be used for optical fiber sensing applications in harsh conditions due to its robustness to high temperature, high radioactivity, and resistance to chemical corrosion as compared to optical sensors using silica fiber. However, SC fiber grown via the laser-heated pedestal growth (LHPG) technique innately does not have a core-cladding structure found in standard optical fiber, resulting in optical losses. In this work we investigate optimization of the growth parameters of a two LHPG process used to grow SC fiber with a graded index via introduction of dopants to the feedstock material. Feedstock material is fabricated with the first LHPG device, then sol-gel dip-coated to create outer films of dopant material. The dip-coated feedstock is used to grow SC fiber in which segregation of the dopant constituents occurs, resulting in a graded index of refraction across the fiber, and an effective core-cladding structure. Hardware and software improvements to both LHPG systems are presented and the growth parameters for short pieces of ~320-330 μm diameter YAG fiber has been established. Characterization techniques/procedures have also been established for future grown SC fiber. These improvements and preparations are anticipated to result in a significant increase in grown fiber quality with a similar growth rate to that previously established.

Lander, Gary↗