Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Analysis of Aerobee 17.012 data

The results are summarized of reduction and analysis of data acquired during the flight of NASA-Aerobee 17.012CG. This rocket was launched from White Sands Missile Range on 6 April 1974 at 0410 U.T. The primary instrument in the experiment payload was a singly focussing x-ray reflector system sensitive in the range from 0.18 to 3 keV. X-ray detectors for this system consisted of two gas flow proportional counters with fields of view defined by apertures of 0.1 deg and 0.3 deg at the reflector focus. A Bragg spectrometer utilizing KAP crystals was included in the payload with the objective of detecting the Lyman alpha line of 0 VIII at 18.97A in the Puppis supernova remanant. A 35 mm camera photographed the star field every 1.6 sec throughout the flight to provide aspect information.

Catura, R. C.↗

An imaging vector magnetograph for the next solar maximum

Measurements of the vector magnetic field in the solar atmosphere with high spatial and temporal resolution over a large field of view are critical to understanding the nature and evolution of currents in active regions. Such measurements, when combined with the thermal and nonthermal X-ray images from the upcoming Solar-A mission, will reveal the large-scale relationship between these currents and sites of heating and particle acceleration in flaring coronal magnetic flux tubes. The conceptual design of an imaging vector magnetograph that combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and a rapid digital tape recorder are described. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (4 x 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectra range (5000 to 8000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically dominated chromosphere, as well as effective co-alignment with Solar-A's X-ray images.

Canfield, Richard C.↗

Instrumentation in astronomy VII; Proceedings of the Meeting, Tucson, AZ, Feb. 13-17, 1990

The topics discussed include IR detectors and instrumentation, detectors, other instrumentation, optical instrumentation, and space instrumentation. Papers are presented on the IR spectrometer/imager for the ESO VLT, the fiber-coupled high-resolution IR array spectrometer for the Kuiper Airborne Observatory, the Balloon-Borne Infrared Telescope for FIR spectroscopy, and a simple transputer-based CCD camera controller. Attention is given to CCD guidance system for William Herschel Telescope, the New Technology Telescope control/acquisition system as a prototype for the VLT, a control system for spincasting 8-m borosilicate honeycomb mirrors, echelle spectrographs for 8-m class telescopes, and fiber spectroscopy at Palomar Observatory. Other papers are on the Kitt Peak National Observatory fiber actuator device, a two-star photoelectric photometer, an ultrahigh-resolution XUV spectroheliograph, an optical monitor for X-ray satellites, and large-format electrographic and array detectors for a space Schmidt imaging telescope.

Crawford, David L.↗

Highly versatile computer-controlled television detector system

A description is presented of a television detector system which has been designed to accommodate a wide range of applications. It is currently being developed for use in X-ray diffraction, X-ray astrophysics, and electron microscopy, but it is also well suited for astronomical observations. The image can be integrated in a large, high-speed memory system, in the memory of a computer system, or the target of the TV tube or CCD array. The detector system consists of a continuously scanned, intensified SIT vidicon with scan and processing electronics which generate a digital image that is integrated in the detector memory. Attention is given to details regarding the camera system, scan control and image processing electronics, the memory system, and aspects of detector performance.

Kalata, K.↗

A normal incidence X-ray telescope sounding rocket payload

Progress is reported on the following major activities on the X-ray telescope: (1) complete design of the entire telescope assembly and fabrication of all front-end components was completed; (2) all rocket skin sections, including bulkheads, feedthroughs and access door, were specified; (3) fabrication, curing and delivery of the large graphite-epoxy telescope tube were completed; (4) an engineering analysis of the primary mirror vibration test was completed and a decision made to redesign the mirror attachment system to a kinematic three-point mount; (5) detail design of the camera control, payload and housekeeping electronics were completed; and (6) multilayer mirror plates with 2d spacings of 50 A and 60 A were produced.

Golub, L.↗

Thermographic measurement of fatigue damage

The paper presents a thermographic technique developed to measure the extent of fatigue damage in composite materials during fatigue loading. It is noted that heat generated by cyclic loading of fatigue damaged material raises the surface temperature. These temperatures were measured with an infrared camera and were used as boundary conditions in a finite element heat transfer program, which has been developed especially to calculate the extent of the heat generation zone, and thereby to define the fatigue damage zone. It is reported that the finite element program was verified by comparing calculated heat generation with the actual heat generation for a simple heat transfer problem that had a closed form solution. Damage zones are calculated for several boron/epoxy fatigue specimens from thermograms of specimens. The calculated damage zones were compared with damage detected by C-scan, X-ray, and scanning electron microscope (SEM) examinations. It is concluded that the analysis was effective in locating the boundaries of the fatigue damage zones.

Whitcomb, J. D.↗

Solid state imagers and their applications; Proceedings of the Meeting, Cannes, France, November 26, 27, 1985

Topics treated include the use of semiconductor imagers in high energy particle physics, an X-ray image sensor based on an optical TDI-CCD imager, and an electron-sensitive CCD readout array for a circular-scan streak tube. Papers are presented on the pan-imager, high resolution linear arrays, the reduction of reflection losses in solid-state image sensors, a high resolution CCD imager module with swing operation, large area CCD image sensors for scientific applications, and new readout techniques for frame transfer CCDs. Consideration is given to advanced optoelectronical sensors for autonomous rendezvous/docking and proximity operations in space, the testing and characterization of CCDs for the Rosat star sensors, an advanced radial camera for the Hubble Space Telescope, and scanning or staring infrared imagers.

Declerck, Gilbert J.↗

Apollo 15 orbital science summary.

In this paper, summary results of the Apollo 15 orbital science payload are given, and some quick-look results of Apollo 16 are discussed. Geochemical instruments, consisting of gamma-ray, X-ray, and alpha particle spectrometers, have provided a chemical map of the lunar surface flown over by Apollo 15. The Laser Altimeter and frontside gravity data have shown some unexpected results with regard to the lunar shape, and provided new basis for understanding lunar mascons. A magnetometer, aboard the small subsatellite, has located magnetic anomalies principally on the lunar farside, and has shown that the small lunar magnetic field is smoother on the frontside than on the back. The mass spectrometer, in orbit aboard the Command and Service Modules, has measured unexpectedly large populations of molecules at orbital altitude (110 km), mostly due to spacecraft contamination. Two major camera systems have provided the first systematic metric quality photography and concurrent high resolution stereo coverage of the lunar surface.

Esenwein, G. F.↗

IUE observations of a luminous M supergiant that exhibits emission continuum in the far ultraviolet

IUE observations of the late-type M supergiant star TV Gem which reveal an intense continuum in the far ultraviolet are discussed. TV Gem was observed in low dispersion in November 1979 and in high and low dispersion in January 1980 by the short and long wavelength cameras of the IUE spectrometer. An essentially featureless UV continuum was obtained, with the exception of a number of broad absorption features in the short wavelength region. A comparison with ground-based observations indicates that at wavelengths greater than 3200 A the continuum emission is essentially due to the M1 supergiant, while at shorter wavelengths the continuum is dominated by a hot companion. The UV continuum can be explained by a B9 or A1 III-IV early companion approximately 2 to 3 magnitudes fainter than the M1 supergiant, or by an accretion disk formed by mass transfer from the extended envelope of the M1 primary onto the surface of a highly condensed secondary. Soft X-ray observations from HEAO 2 are suggested as a means to investigate these interpretations.

Michalitsianos, A. G.↗

Soft X-Ray Telescope (SXRT)

The soft X-ray telescope (SXRT) will provide direct images of the solar corona with spatial resolution of about 1 arcsecond. These images will show the global structure of the corona, the location and area of coronal holes, and the presence of even the smallest active regions and flares. The good spatial resolution will show the fine scale magnetic structure and changes in these phenomena. These observations are essential for monitoring, predicting, and understanding the solar magnetic cycle, coronal heating, solar flares, coronal mass ejections, and the solar wind. These observations complement those of the White Light Coronagraph and Ultra-Violet Coronal Spectrometer; the SXRT will detect active regions and coronal holes near the east limb, thereby giving a week or more of advanced warning for disturbed geomagnetic conditions at Earth. The instrument consists of a grazing incidence collecting mirror with a full disk film camera at the primary focus, and a secondary relay optic that feeds a CCD camera with a field of view about the size of an average active region.

Moore, R. L.↗

Soft X-ray telescope (SXRT)

The soft X-ray telescope (SXRT) will provide direct images of the solar corona with spatial resolution of about 1 arcsecond. These images will show the global structure of the corona, the location and area of coronal holes, and the presence of even the smallest active regions and flares. The good spatial resolution will show the fine scale magnetic structure and changes in these phenomena. These observations are essential for monitoring, predicting, and understanding the solar magnetic cycle, coronal heating, solar flares, coronal mass ejections, and the solar wind. These observations complement those of the White Light Coronagraph and Ultra-Violet Coronal Spectrometer; the SXRT will detect active regions and coronal holes near the east limb, thereby giving a week or more of advanced warning for disturbed geomagnetic conditions at Earth. The instrument consists of a grazing incidence collecting mirror with a full-disk film camera at the primary focus, and a secondary relay optic that feeds a CCD camera with a field of view about the size of an average active region.

Moore, R.↗

Method for X-ray study under extreme temperature and pressure conditions

Vacuum chamber environmental simulator and X ray camera are used to study the stability of various minerals in extreme environmental conditions. An ion pump creates the desired vacuum. Exact sample positioning is obtained with a bellows sealed linear motion feed-through. Temperature control is by means of fluid conductive heat transfer.

Paus, L. L.↗

Apollo scientific experiments data handbook

A brief description of each of the Apollo scientific experiments was described, together with its operational history, the data content and formats, and the availability of the data. The lunar surface experiments described are the passive seismic, active seismic, lunar surface magnetometer, solar wind spectrometer, suprathermal ion detector, heat flow, charged particle, cold cathode gage, lunar geology, laser ranging retroreflector, cosmic ray detector, lunar portable magnetometer, traverse gravimeter, soil mechanics, far UV camera (lunar surface), lunar ejecta and meteorites, surface electrical properties, lunar atmospheric composition, lunar surface gravimeter, lunar seismic profiling, neutron flux, and dust detector. The orbital experiments described are the gamma-ray spectrometer, X-ray fluorescence, alpha-particle spectrometer, S-band transponder, mass spectrometer, far UV spectrometer, bistatic radar, IR scanning radiometer, particle shadows, magnetometer, lunar sounder, and laser altimeter. A brief listing of the mapping products available and information on the sample program were also included.

Eichelman, W. F.↗

Long-term X-ray studies of Sco X-1

No modulation of the 3-6 keV X-ray intensity of Sco X-1 at a level of excess of 1% was observed at the optical period of .787313d. Evidence is found for shot-noise character in a large fraction of the X-ray emission. Almost all of the Sco X-1 emission can be synthesized in terms of approximately 200 shots per day, each with a duration of approximately 1/3 day. A pinhole camera was used to obtain data and the data were statistically analyzed.

Holt, S. S.↗

The Pinhole/Occulter Facility

A large occulting system in space can be used for high resolution X-ray observations and for large aperture coronagraphic observations in visible and UV light. The X-ray observations can combine high angular resolution in hand (10 keV) X-radiation with the high sensitivity of a multiple pinhole camera, and can permit sensitive observations of bremsstrahlung from nonthermal particles in the corona. The large aperture coronagraphs have two major advantages: high angular resolution and good photon collection. This will permit observations of small scale structures in the corona for the first time and will give sufficient counting rates above the coronal background rates for sensitive diagnostic analysis of intensities and line profiles for coronal structures in the solar wind acceleration region. The technical basis for performing observations with a large occulting system in these three wavelength ranges is described as well as a pinhole/occulter facility presently being considered for Spacelab. Some indications about future developments are included.

Hudson, H. S.↗

Three-dimensional and tomographic imaging device for X-ray and gamma-ray emitting objects

An instrument for obtaining quantitative, three-dimensional and tomographic information relating to X-ray and gamma-ray emitting objects and for the orthoscopic viewing of such objects includes a multiple-pinhole aperture plate held spaced from an X-ray or gamma-ray to visible-light converter which is coupled to a visible-light image intensifier. The spacing between the aperture plate and the converter is chosen such that the mini-images of an emitting object formed by the pinholes do not substantially overlap as they impinge on the converter. The output of the image intensifier is digitized by a digitizing camera in terms of position and intensity and fed into a digital computer. The computer may output quantitative information relating to the emitting object directly, such as that relating to tomograms, or provide information in analogue form when coupled with a suitable viewing device to give an orthoscopic, three-dimensional image of the object.

Yin, L. I.↗

The AXAF high resolution camera (HRC) and its use for observations of distant clusters of galaxies

The High Resolution Camera being developed for AXAF is briefly described, comparing it with its predecessor, the Einstein HRI, and providing preliminary performance data. The HRC is a 10 cm x 10 cm detector with CsI coated microchannel plates providing a large field of view device with high X-ray quantum efficiency. The overall sensitivity of the HRC on AXAF is about 50 times that of the Einstein HRI. An example of the power of this instrument is discussed in the context of studies of distant clusters of galaxies. The HRC can detect individual galaxies in a cluster of redshift 1, if they are similar to the early-type galaxies in nearby clusters that have been observed by the Einstein instruments. The HRC will be used to measure the luminosity function for clusters of galaxies as a function of their distance up to a redshift of 1. This will allow observation of evolutionary effects in clusters as a whole, while the detection of individual galaxies will permit studies of galaxy evolution in a cluster environment.

Murray, S. S.↗