Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-Ray Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Lanthanum-Promoted Electrocatalyst for the Oxygen Evolution Reaction: Unique Catalyst or Oxide Deconstruction?

A conventional performance metric for electrocatalysts that promote the oxygen evolution reaction (OER) is the current density at a given overpotential. However, the assumption that increased current density at lower overpotentials indicates superior catalyst design is precarious for OER catalysts in the working environment, as the crystalline lattice is prone to deconstruction and amorphization, thus greatly increasing the concentration of catalytic active sites. We show this to be the case for La 3+ incorporation into Co 3 O 4 . Powder X-ray diffraction (PXRD), Raman spectroscopy and extended X-ray absorption fine structure (EXAFS) reveal smaller domain sizes with decreased long-range order and increased amorphization for La-modified Co 3 O 4 . This lattice deconstruction is exacerbated under the conditions of OER as indicated by operando spectroscopies. The overpotential for OER decreases with increasing La 3+ concentration, with maximum activity achieved at 17% La incorporation. HRTEM images and electron diffraction patterns clearly show the formation of an amorphous overlayer during OER catalysis that is accelerated with La 3+ addition. O 1s XPS spectra after OER show the loss of lattice-oxide and an increase in peak intensities associated with hydroxylated or defective O-atom environments, consistent with Co(O) x (OH) y species in an amorphous overlayer. Furthermore, our results suggest that improved catalytic activity of oxides incorporated with La 3+ ions (and likely other metal ions) is due to an increase in the number of terminal octahedral Co(O) x (OH) y edge sites upon Co 3 O 4 lattice deconstruction, rather than enhanced intrinsic catalysis.

Catalysts↗

Biopolymer-Templated Titania Film Formation for Nanostructured Coatings Revealed by Machine Learning-Supported Time-Resolved Analysis

This study presents a machine learning approach to derive the film formation of biopolymer-templated titania nanostructures during spray deposition, in combination with in situ grazing-incidence small-angle X-ray scattering (GISAXS). A neural network trained on synthetic GISAXS data directly predicts domain-size distributions from experimental two-dimensional scattering patterns, capturing the full kinetics of nanostructure evolution with high temporal resolution. The predictions reveal hierarchical size distributions and periodic growth features, consistent with layer-by-layer spray deposition and validated by complementary scanning electron microscopy (SEM) imaging. Quantitative comparison with conventional parametric GISAXS fits shows good qualitative agreement, with systematic differences explained by domain-shape assumptions and resolved by applying a geometric scaling factor. Simulated SEM-like surfaces derived from neural network outputs reproduce the porous, foam-like nanoscale morphology observed experimentally, reinforcing the method’s credibility. This integrated approach enables real-time, nondestructive, statistically averaged monitoring of bulk nanostructure development in functional coatings, offering a scalable methodology to accelerate the characterization and process control of sustainably manufactured nanostructured titania films for energy-related applications such as photocatalysis and photovoltaics.

Heger, JulianEliah↗

Enabling Bipolar Membrane Manufacturing Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Enabling Roll-to-Roll Manufacturing of Bipolar Membranes Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Pulsed laser synthesis of mesoporous metal chalcogenide thin films

Mesoporous films of the metal chalcogenide B-FeSe were grown on MgO substrates by KrF pulsed laser deposition (PLD) in an argon background. At 100 mTorr, gated intensified charge-coupled device imaging and ion probe measurements showed that the plasma plume responsible for crystal growth initially comprised three components, with distinct expansion velocities. Plume interactions with the substrate heater and ablation target gave rise to complex dynamics, including collisions between the charged leading edge—rebounding between the substrate and the target—and slower-moving species in the plume interior. Film growth was dominated by species with kinetic energies ≤0.5 eV/atom. X-ray reflectivity revealed that films grown in this environment—with a substrate temperature of 350 ° C, a laser fluence of 1.0 J cm −2 , and a 7.5 mm 2 spot area—formed a porous framework with 15% porosity. Atomic force microscopy showed surface features that suggest pore sizes below 100 nm. X-ray diffraction indicated that the porous films were epitaxial with respect to the substrate and likely grew by oriented-attachment of gas-phase molecular clusters or very small nanoparticles, in contrast to the conventional epitaxy of vacuum films from atomic constituents. The in-plane orientation of the mesoporous films was B-FeSe [100]||[110] MgO, attributed to the soft landing of pre-formed crystallites on the MgO substrates, where protruding Se rows of B-FeSe aligned with corrugations of the MgO surface. In conclusion, this work implies that growth of candidate electrocatalyst materials by PLD in inert gas background may allow mesoporous frameworks with a single crystallographic orientation that expose specific crystal facets for electrochemical reactions and active site engineering.

cluster epitaxy↗

Comparative study on the formation of Cr and Ti ohmic contacts to (001) β -Ga 2 O 3

Here, a comparative study of Cr/Au and Ti/Au ohmic contacts on (001) β-Ga 2 O 3 was conducted. The electrical behavior from current-voltage measurements and the interfacial composition and microstructure as determined from high-resolution transmission electron microscopy (TEM) with energy dispersive x-ray analysis were compared for the different contacts at selected points in an annealing series (300–700 °C, 1 min. anneals in N 2 ). Cr/Au contacts became ohmic at temperatures (300–350 °C) approximately 50–100 °C lower than Ti/Au contacts (400–450 °C). Cr/Au and Ti/Au contacts demonstrated optimal ohmic behavior (lowest resistance) when annealed to 450–500 and 500–600 °C, respectively, with Ti/Au contacts yielding a lower total resistance than Cr/Au. Cross-sectional TEM images of Cr/Au contacts annealed at 450 °C revealed the presence of Au nanoclusters at the Ga 2 O 3 interface and CrO x layers at both the top of the contact and the Ga 2 O 3 interface. Whereas TiO x also formed at the top and bottom interfaces in 450 °C-annealed Ti/Au contacts, the TiO x surface layer appeared to be variable in thickness and/or discontinuous, unlike the CrO x surface layer. Au nanoclusters were not detected at the interface in the Ti/Au contacts. The interdiffusion and oxidation observed in both contact metallizations point to the need for diffusion barriers that may allow these contacts to be used in future Ga 2 O 3 -based devices that operate at elevated temperatures.

36 MATERIALS SCIENCE↗

Virtual Inspection of Advanced Manufacturing via Process-Scale Digital Twins (Abbreviated Report)

Inspection and certification comprise the most significant bottlenecks in advanced manufacturing for NNSA applications, often requiring far more time and resources than the fabrication of the parts themselves. Traditional methods, such as manual review and X-ray computed tomography, are not only slow and costly, but also struggle to provide a clear connection between manufacturing instructions and the final performance of critical components. This gap limits both the agility and assurance needed to support the modernization and safety of the United States nuclear stockpile. In response, our Strategic Initiative established a digital twin framework that integrates realtime process monitoring, automated data analysis, and immersive virtual reality collaboration into a unified inspection pipeline. By leveraging data from sensors, machine instructions, and imaging, we created high-fidelity virtual models of manufactured parts that could be rapidly analyzed and certified. This approach was first demonstrated with Direct Ink Write, and then extended to other manufacturing settings, including conventional (or “subtractive”) manufacturing and to predict the end of life performance of parts per the aging and lifetimes programs. The result is a transformational capability: inspection times have been reduced by a factor of 120,000 without loss of accuracy and while simultaneously improving traceability and confidence in part quality. This framework not only streamlines certification for critical applications, but also positions the national security enterprise to respond more flexibly to emerging challenges, supporting agile manufacturing and digital engineering practices across a broad range of mission-relevant domains.

42 ENGINEERING↗

Role of Surface Hydroxyls and Lattice Oxygen in Governing Selectivity and Restructuring During Acetic Acid Conversion on Fe 3 O 4 (001)

Understanding the reactivity of carboxylic acids on metal oxide surfaces is critical for elucidating ketonization mechanisms relevant to biomass upgrading. Here, we investigate the adsorption and thermal decomposition of acetic acid (CH 3 COOH) on Fe 3 O 4 (001) using scanning tunneling microscopy (STM), temperature-programmed reaction spectroscopy (TPRS), and X-ray photoelectron spectroscopy (XPS). At room temperature, acetic acid adsorbs dissociatively to form ordered bidentate acetate (CH 3 COO) overlayer that lifts the (√2 × √2)R 45° surface reconstruction. TPRS reveals ketene (CH 2 CO) as the dominant product, along with CO, CO 2 , and H 2 O, the latter evolving via a Mars–van Krevelen (MvK) mechanism. Isotopic labeling shows preferential CO 2 formation from the carboxyl carbon and a more balanced CO/CO 2 ratio from the methyl carbon, suggesting distinct oxidation pathways. STM imaging reveals embedded acetate intermediates filling surface oxygen vacancies created in MvK steps. Upon product formation completion (~700 K), extensive surface etching is observed, with pits elongated along the octahedral Fe rows. Approximately 20% of the surface oxygen is removed, consistent with vacancy formation stoichiometry inferred from product distributions. These findings demonstrate that carboxylate-induced restructuring of Fe 3 O 4 (001) involves both surface healing and reduction processes, offering mechanistic insights relevant to ketonization and broader carboxylic acid chemistry on metal oxides.

acetic acid↗

On the formation of swelling and related flaws in laser powder bed fusion

Process monitoring in laser powder bed fusion additive manufacturing can provide insights into stochastic anomalies, melt pool and plume dynamics, and part quality. Swelling, a build anomaly where overbuilt material protrudes through the powder layer after recoating, is readily detectable in post-recoat visible light images of the powder bed. Here, this work identifies several of the underlying mechanisms driving swelling formation by analyzing the influence of processing parameters, laser scan paths, and build plate locations on the presence of swelling detected in situ. Swelling near the edge of the part and swelling in the internal region of the part are shown to correlate with different process conditions. Edge and internal swelling may be driven by different phenomena, with edge swelling predominately occurring on the edge of a part facing the laser module and correlated to clusters of near-surface voids (detected with X-ray computed tomography). A larger spot size, higher laser power, and lower scan velocity also increased the presence of edge swelling. Laser spot size and scan path influenced internal swelling, which occurred preferentially with a larger spot size and in regions with large melt pools, caused by localized heat accumulation due to non-optimal processing parameters or scan path strategies. For coupons processed with a slicer-defined maximum scan vector length, swelling seldom occurred at internal vector-stripe boundaries. These results provide a mechanistic understanding of how swelling can be linked to material flaws, insight into how some instances of swelling can be avoided, and evidence supporting the use of swelling as an in situ indicator for quality assurance and part qualification.

Anomaly↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Orbital and short-term variability of iron absorption

We present the first high-resolution spectroscopy of the black hole high-mass X-ray binary Cygnus X-1 with XRISM, including orbital-phase-resolved analyses and tentative evidence of short-term variability in the Fe K band on second timescales. Using data from the Performance Verification phase in 2024 April, we analyzed spectral variability across orbital phases with the Resolve microcalorimeter and the Xtend CCD imager. The unprecedented resolution of Resolve reveals variability in highly ionized Fe absorption lines. The absorption features show orbital-phase-dependent variability in column density, ionization state, and blueshifted velocity, suggesting structural variations in the focused stellar wind along the line of sight. We also find indications of subtle broadening of the neutral Fe emission profile. In addition, intensity-sorted spectroscopy during dip phases suggests possible variability on timescales of a few seconds in the absorption features, consistent with cooler, denser, and lower-ionized gas clumps. Although the statistical significance is limited, these results hint that the stellar wind and the X-rays from the accretion disk around the black hole may interact on timescales as short as a few seconds. These XRISM results constrain wind-fed accretion in Cyg X-1 and highlight Resolve’s capability to probe plasma environments in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Synthesis and Properties of Bulk Mg 3 WN 4 in a Wurtzite-Derived Structure

Experimental synthesis of theoretically predicted materials with controlled elemental coordination environments can lead to the realization of useful properties, such as facile ion transport or ferroelectric switching. Among such materials are ternary nitrides in the Mg−W−N composition space, where several stable and metastable compounds have been predicted and synthesized recently in bulk and film forms. Here, we report for the first time on the bulk synthesis of Mg 3 WN 4 in a wurtzite-derived crystal structure via a solid-state metathesis reaction. In situ synchrotron powder X-ray diffraction shows how the ion exchange proceeds from Li 6 WN 4 + MgCl 2 precursors to Mg 3 WN 4 + LiCl products, with the reaction starting slowly near 380 °C and completing by 600 °C, including the presence of a competing disordered rocksalt-derived phase (Mg,W)N above 440 °C. The follow-up ex situ powder synthesis at 400 °C for 0.5 h with 10% excess MgCl 2 reveals the cation-ordered nature of the wurtzite-derived Mg 3 WN 4 structure with polar symmetry confirmed by second-harmonic generation measurements. Optical absorption spectra, chemical composition analysis, and electron microscopy imaging suggest that bulk Mg 3 WN 4 obtained via metathesis reaction is prone to defect formation. Overall, this study shows that selective ex situ synthesis of the phase-pure ternary nitrides, informed by in situ measurements, is possible by carefully controlling the thermal budget of the reaction and paves the way toward property characterization of the Mg 3 WN 4 wurtzite-derived material.

36 MATERIALS SCIENCE↗

Data for "High-resolution microCT reveals relationships between stomata and interior leaf anatomy in Sorghum"

Includes three different types of stacks, in two folders: "REC_RAW_STACKS.zip" contains: (1) Raw gray-scale reconstructed microCT x-ray scans, in the form of individual stacks per sample. "ML_STACKS.zip" contains: (2) Stacks that have been labeled using a machine-learning mask-RCNN pipeline identifying epidermis, mesophyll, airspace, vascular bundle, and background. (3) Stacks that have stomata locations labeled using a small point. The three types of stacks were used to calculate a variety of anatomical and physiological traits, using ImageJ Macros provided on Github: https://github.com/leakey-lab/microCT-Macros-Fischer. Young leaves from WT and transgenic Sorghum plants. CSV "microCT_REC2_META.csv" contains metadata, including sample/sub-sample labels.

3D↗

Spatiotemporal and Statistical Mapping of Transition Metal Equilibria in Alkaline Media

Transition metal dissolution and redeposition (D/R) kinetics in alkaline media play a critical role in various chemical and electrochemical processes. Competitive reaction kinetics between different transition metals can modulate individual metal behavior in these processes. To date, these phenomena have remained largely unmeasured, and even when captured, they are difficult to statistically characterize due to their dynamic nature, simultaneous occurrence, and spatially heterogeneous nature. Here, in this study, we develop a statistical analysis framework based on in situ and operando X-ray fluorescence microscopy (XFM) to investigate the relative D/R kinetics of multiple transition metals in alkaline media. By employing statistical analysis, we quantify the spatial distribution of D/R species and assess the rate at which the system reaches equilibrium under varying reaction conditions. We show that pH does not simply change the rate of dissolution and redeposition, but reorganizes the cross-element kinetic correlations among Ni, Fe, and Mn and accelerates the spatial equilibration of D/R events, as quantified through correlation analysis, reaction-rate estimation, probability function distributions, and texture-based monitoring statistics. Additionally, we demonstrate how modifying the solvent environment can influence D/R kinetics, providing a pathway for tuning materials synthesis and process optimization. Our study offers valuable insights into the complex interplay between different transition metals and provides a reliable statistical framework for spatial analysis of diverse imaging data sets, enabling deeper extraction of latent information across multiple modalities.

36 MATERIALS SCIENCE↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE↗

Mechanistic Insights into Defect-Mediated Crystallization Revealed by Lattice Strain Evolution

Structural defects and lattice strain are intrinsic to many crystalline materials, yet their roles in controlling chemical reaction mechanisms and directing crystallization pathways remain poorly understood. Here, in this study, we revealed the three-dimensional evolution of strain and dislocation defects at the nanoscale during the growth of heterogeneously nucleated barite (BaSO 4 ) and calcite (CaCO 3 ) crystals by using coherent X-ray scattering, electron microscopy, and molecular simulations. Unlike barite, which formed with minimal internal strain, calcite developed dislocation defects and exhibited spatially varying strain that increased during growth. During growth in Sr-rich solutions, calcite likely incorporates Sr 2+ into the defects, which further modulates the local lattice structure and increases both the compressive and tensile strain. These findings suggest that calcite crystallization was likely dominated by attachment of precursor phases, which gave rise to defect-enriched domain structures not predicted by classical growth models. By linking defect formation to ion incorporation and growth dynamics, this work provides fundamental insight into how lattice-level strain heterogeneity governs the chemical reactivity of ionic crystals.

Bragg coherent diffractive imaging↗