Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Switchable photovoltaic windows enabled by reversible photothermal complex dissociation from methylammonium lead iodide

Materials with switchable absorption properties have been widely used for smart window applications to reduce energy consumption and enhance occupant comfort in buildings. In this work, we combine the benefits of smart windows with energy conversion by producing a photovoltaic device with a switchable absorber layer that dynamically responds to sunlight. Upon illumination, photothermal heating switches the absorber layer - composed of a metal halide perovskite-methylamine complex - from a transparent state (68% visible transmittance) to an absorbing, photovoltaic colored state (less than 3% visible transmittance) due to dissociation of methylamine. After cooling, the methylamine complex is re-formed, returning the absorber layer to the transparent state in which the device acts as a window to visible light. The thermodynamics of switching and performance of the device are described. In conclusion, this work validates a photovoltaic window technology that circumvents the fundamental tradeoff between efficient solar conversion and high visible light transmittance that limits conventional semitransparent PV window designs.

14 SOLAR ENERGY↗

Planck 2013 results. IV. Low Frequency Instrument beams and window functions

This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relies on the measurements performed during Jupiter observations. By stacking the datafrom multiple Jupiter transits, the main beam profiles are measured down to-20 dB at 30 and 44 GHz, and down to-25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. The Planck pre-launch optical model is conveniently tuned to characterize the main beams independently of any noise effects. This approach provides an optical model whose beams fully reproduce the measurements in the main beam region, but also allows a description of the beams at power levels lower than can be achieved by the Jupiter measurements themselves. The agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band. The simulated beams are used for the computation of the window functions for the effective beams. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer bandshapes. The total uncertainties in the effective beam window functions are: 2% and 1.2% at 30 and 44 GHz, respectively (at ℓ ≈ 600), and 0.7% at 70 GHz (at ℓ ≈ 1000).

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2015 results: IV. Low Frequency Instrument beams and window functions

This article presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30 and 44 GHz, and down to -30 dB at 70 GHz. It has been confirmed that the agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band (within the 20 dB contour from the peak, the rms values are 0.1% at 30 and 70 GHz; 0.2% at 44 GHz). Simulated polarized beams are used for the computation of the effective beam window functions. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer band shapes. The total uncertainties in the effective beam window functions are 0.7% and 1% at 30 and 44 GHz, respectively (at ℓ ≈ 600); and 0.5% at 70 GHz (at ℓ ≈ 1000).

79 ASTRONOMY AND ASTROPHYSICS↗

Electron Bernstein wave heating and emission measurement through the very narrow O-X-B mode conversion window in the LHD

In the large helical device (LHD), the theoretically predicted width of the ordinary-extraordinary-electron Bernstein wave (O-X-B) mode conversion (MC) window is comparable to the beam width and the power deposition is located in the off-axis region if the 77GHz fundamental electron cyclotron (EC) wave of is launched from an existing horizontal port antenna. In the experiment, the actual MC window location was looked for with changing the aiming. The effective aiming with that the increase of the stored energy was observed was two degrees apart from the location of the theoretical MC window at a maximum. Measurement of the waves originated from the thermally emitted EBW and radiated via the B-X-O mode conversion process is effective to improve the accuracy of the theoretical prediction with comparison between the theoretical and the experimental results. The theoretical prediction suggests that the width of the MC window of the fundamental 77GHz EC wave can be expanded if the lower port antenna is used. On the other hand, the MC window of the second harmonic 154GHz EC wave is blocked by horizontal port wall if another horizontal port antenna is used. It is required to move the final mirror of the quasi-optical antenna toward the plasma surface. Focusing of the beam at the plasma cutoff is (PC) also necessary for the effective mode conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The suppression effect of a periodic surface with semicircular grooves on the high power microwave long pill-box window multipactor phenomenon

To improve the transmitting power in an S-band klystron, a long pill-box window that has a disk with grooves with a semicircular cross section is theoretically investigated and simulated. A Monte-Carlo algorithm is used to track the secondary electron trajectories and analyze the multipactor scenario in the long pill-box window and on the grooved surface. Extending the height of the long-box window can decrease the normal electric field on the surface of the window disk, but the single surface multipactor still exists. It is confirmed that the window disk with periodic semicircular grooves can explicitly suppress the multipactor and predominantly depresses the local field enhancement and the bottom continuous multipactor. The difference between semicircular and sharp boundary grooves is clarified numerically and analytically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing the performance of bandpass photon detectors for inverse photoemission: Transmission of alkaline earth fluoride window crystals

Bandpass photon detectors are widely used in inverse photoemission in the isochromat mode at energies in the vacuum-ultraviolet spectral range. The energy bandpass of gas-filled counters is usually formed by the ionization threshold of the counting gas as high-pass filter and the transmission cutoff of an alkaline earth fluoride window as low-pass filter. The transmission characteristics of the window have, therefore, a crucial impact on the detector performance. We present transmission measurements in the vacuum-ultraviolet spectral range for alkaline earth fluoride window crystals in the vicinity of the transmission cutoff as a function of crystal purity, surface finish, surface contamination, temperature, and thickness. Our findings reveal that the transmission characteristics of the window crystal and, thus, the detector performance depend critically on these window parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting operational windows of ELMs suppression by resonant magnetic perturbations in the DIII-D and KSTAR tokamaks

A newly developed plasma response model, combining the nonlinear two-fluid MHD code TM1 and toroidal MHD code GPEC run in ideal mode, quantitatively predicts the narrow isolated q 95 windows (Δq 95 ~ 0.1) of ELM suppression by n = 1, 2 and 3 resonant magnetic perturbations (RMPs) in both DIII-D and KSTAR tokamaks across a wide range of plasma parameters. The key physics that unites both experimental observations and our simulations is the close alignment of essential resonant q-surfaces and the location of the top of the pedestal prior to an ELM. This alignment permits an applied RMP to produce field penetration due to the lower E × B rotation at the pedestal top rather than being screened. The model successfully predicts that narrow magnetic islands form when resonant field penetration occurs at the top of pedestal, and these islands are easily screened when q 95 moves off resonance, leading to very narrow windows of ELM suppression (typically Δq 95 ~ 0.1). Furthermore, the observed reduction in the pedestal height is also well captured by the calculated classical collisional transport across the island. We recover observed q 95 , β N and plasma shape dependence of ELM suppression due to the effect of magnetic islands on pedestal transport and Peeling-Ballooning- Mode (PBM) stability. Importantly, experiments do occasionally observe wide windows of ELM suppression (Δq 95 > 0.5). Our model reveals that at low pedestal-top density multiple islands open, leading to wide operational windows of ELM suppression consistent with experiment. The model indicates that wide q95 windows of ELM suppression can be achieved at substantially higher pedestal pressure with less confinement degradation in DIII-D by operating at higher toroidal mode number (n = 4) RMPs. As a result, this can have significant implications for the operation of the ITER ELM control coils for maintaining high confinement together with ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Analysis of Design Alternatives of Actively Cooled RF Window for MPEX

The Materials Plasma Exposure eXperiment (MPEX) has been designed as a linear plasma divertor simulator in order to address plasma material interaction (PMI) science for next-generation fusion devices. It will have the capability to test neutron irradiated samples with plasma fluxes of greater than 10 24 m -2 s -1 . It is expected to operate steady state for up to 10 6 s to consider PMI affects through reactor end of life. The conceptual design of MPEX was completed in 2019, with preliminary design having begun in 2020. The plasma source for MPEX is a helicon antenna, where the energized helical antenna sits outside of the vacuum in order to minimize impurities in the plasma. It is expected to receive up to 200 kW of continuous power, and so the antenna and the window must be actively cooled. The water-cooled copper antenna has been operated at full power on the Proto-MPEX device (which is a test facility to demonstrate the plasma source and heating systems). The water-cooled window, however, is a novel component that must meet numerous competing requirements. It requires a low dielectric loss to allow the Radio Frequency (RF) power to create the plasma within the vacuum boundary. It must be structurally robust to handle the significant heat flux from the plasma and any heat from dielectric coupling. It must be compatible with the coolant (preferably water). It requires a vacuum seal that minimizes impurities into the plasma and does not compromise the structural integrity of the window. Two window designs have been tested. Results from these tests, where temperatures are measured and heat fluxes inferred from infrared camera data, have been correlated with thermal-structural simulations. When these simulations are extrapolated to the full power steady-state heat fluxes that are expected in MPEX, the designs do not appear to have the necessary structural robustness. This study explores design alternatives for the MPEX helicon antenna window, presents analysis results for several of the alternatives, and shows a viable solution that satisfies the requirements for MPEX operation.

Tipton Jr, Joseph↗

Impact of window temperature variations on ITER toroidal interferometer and polarimeter (TIP) measurements

Abstract The toroidal interferometer and polarimeter (TIP) is one of the primary electron density diagnostics on ITER. To meet measurement requirements over several thousand seconds, environmental factors such as changes in the window temperature, air temperature, and humidity, which can cause uncompensated phase drifts, must be minimized. This paper reports measurements of the phase shift induced by ZnSe and BaF₂ windows as their temperature is varied utilizing the TIP prototype. To accomplish these measurements, test pieces of BaF₂ and ZnSe are placed in a small oven that is located in one leg of the 10.59/5.22 micron two-color interferometer TIP prototype. The oven temperature was varied from room temperature to ∼90 °C, which is slightly higher than the expected window temperatures on ITER. The vibration compensated phase shifts measured for these two materials are dϕᵥ꜀ /dT/L = 0.0121 and −0.275 deg. /°C/cm −1 for BaF₂ and ZnSe, respectively. From these measurements, it was concluded that temperature variations of the environmental/secondary confinement barrier window and primary vacuum window have to be suppressed within approximately 1°C and 2°C, respectively, in order to passively meet the electron density measurement requirements in ITER.

Akiyama, T (ORCID:0000000198469795)↗

Data-driven estimates for light-quark-connected and strange-plus-disconnected hadronic g − 2 window quantities

A number of discrepancies have emerged between lattice computations and data-driven dispersive evaluations of the RBC/UKQCD intermediate-window-hadronic contribution to the muon anomalous magnetic moment. It is therefore interesting to obtain data-driven estimates for the light-quark-connected and strange-plus-disconnected components of this window quantity, allowing for a more detailed comparison between the lattice and data-driven approaches. The aim of this paper is to provide these estimates, extending the analysis to several other window quantities, including two windows designed to focus on the region in which the two-pion contribution is dominant. Clear discrepancies are observed for all light-quark-connected contributions considered, while good agreement with lattice results is found for strange-plus-disconnected contributions to the quantities for which corresponding lattice results exist. The largest of these discrepancies is that for the RBC/UKQCD intermediate window, where, as previously reported, our data-driven result, a μ W 1 , lqc = 198.9 ( 1.1 ) × 10 − 10 , is in significant tension with the results of 8 different recent lattice determinations. Our strategy is the same as recently employed in obtaining data-driven estimates for the light-quark-connected and strange-plus-disconnected components of the full leading-order hadronic vacuum polarization contribution to the muon anomalous magnetic moment. Updated versions of those earlier results are also presented, for completeness. Published by the American Physical Society 2024

Benton, Genessa (ORCID:0009000515763654)↗

The Critical Role of AlInP Window Design in III–V Rear-Emitter Solar Cells

This article highlights the critical role of window design on short circuit carrier collection in rear-emitter solar cells, as demonstrated through modeling and experiment using metamorphic GaAs y P 1-y . Ultimately, if the window design is not carefully considered, surface depletion caused by Fermi level pinning at the window/air interface can extend into regions of active collection resulting in a large increase in effective window/base interface recombination velocity. This was experimentally shown here to result in a potential AM1.5G photocurrent loss of 8.1 mA/cm 2 , or nearly 50%, based on integrated internal quantum efficiency (IQE). Associated IQE modeling and curve fitting indicate that the effective IRV at the GaAs 0.75 P 0.25 /Al 0.64 In 0.36 P interface is increased by multiple orders of magnitude when the window is not sufficiently thick or doped to fully contain the surface depletion to within the window layer. Calculations of the surface depletion depth as a function of doping and the surface Fermi pinning energy level provides insight into the fundamental limits of window thickness. As a result, this allows the estimation of the Al 0.64 In 0.36 P surface pinning level to be at least 1.25 eV below the conduction band edge, or in the bottom half of the bandgap.

14 SOLAR ENERGY↗

Sci—Thur PM: Imaging — 04: An iterative triple energy window (TEW) approach to cross talk correction in quantitative small animal Tc99m and In111 SPECT

Dual isotope SPECT allows simultaneous measurement of two different tracers in vivo. With In111 (emission energies of 171keV and 245keV) and Tc99m (140keV), quantification of Tc99m is degraded by cross talk from the In111 photons that scatter and are detected at an energy corresponding to Tc99m. TEW uses counts recorded in two narrow windows surrounding the Tc99m primary window to estimate scatter. Iterative TEW corrects for the bias introduced into the TEW estimate resulting from un-scattered counts detected in the scatter windows. The contamination in the scatter windows is iteratively estimated and subtracted as a fraction of the scatter-corrected primary window counts. The iterative TEW approach was validated with a small-animal SPECT/CT camera using a 2.5mL plastic container holding thoroughly mixed Tc99m/In111 activity fractions of 0.15, 0.28, 0.52, 0.99, 2.47 and 6.90. Dose calibrator measurements were the gold standard. Uncorrected for scatter, the Tc99m activity was over-estimated by as much as 80%. Unmodified TEW underestimated the Tc99m activity by 13%. With iterative TEW corrections applied in projection space, the Tc99m activity was estimated within 5% of truth across all activity fractions above 0.15. This is an improvement over the non-iterative TEW, which could not sufficiently correct for scatter in the 0.15 and 0.28 phantoms.

60 APPLIED LIFE SCIENCES↗

Low RF Loss DC Conductive Ceramic for High Power Input Coupler Windows for SRF Cavities

Euclid Techlabs, LLC is developing a low RF loss/DC conductive MgTi ceramics for high power input coupler windows for SRF cavities, under DOE SBIR phase II grant DE-SC0017150. JLab was subcontracted to: fabricate two 500 kW capable pre-stressed coaxial windows; provide an RF testing fixture, and test the window with low power and high power RF. This collaboration helped to develop a better material for high power RF windows, with low RF loss and less prone to arcing, with the potential to improve the state of the art high power RF window performance.

36 MATERIALS SCIENCE↗

Thermally Insulating Transparent Barrier (THINNER) coatings on single pane windows

Conventional silica aerogel monoliths can provide remarkable thermal insulation but the presence of large pores (> 30 nm) tends to scatter visible light and render the material opaque or translucent instead of transparent. In addition, they are prone to cracking during synthesis and handling which makes them difficult to integrate in products and in particular in window solutions. This project developed two new solgel synthesis methods using silica precursors or preformed silica nanoparticles and ambient drying to produce mesoporous organo-silica monoliths. The monoliths were (i) thermally insulating, (ii) optically transparent, (iii) flexible, and (iv) hydrophobic. They feature porosity ranging from 50% to 90% with narrow pore size distribution with pore less than 20 nm resulting in excellent optical clarity (haze < 2%) and very low thermal conductivity (< 30 mW/mK). Interestingly, not only porosity but also pore size and mass fractal dimension were found to affect the thermal conductivity of the mesoporous silica. The superior transparency of the monoliths was shown to be attributed to dependent scattering among silica nanoparticles. Flexibility was achieved through trimethylchlorosilane surface modification. Furthermore, process scale-up and integration of the ambigel monoliths into window solutions using optically clear adhesives were also demonstrated in 6”x6” double-pane windows. The aerogel and the window solution were shown to be durable to accelerated aging under UV, moisture, and/or temperature gradient and thermal cycling. Overall, the window solution achieved the technical performance and the cost target of $10/sqft set for the SHIELD program. However, scaling to industry relevant scale (> 10’x10’) remains a challenge due to requirements on the drying process and fume hood size and to the propensity of large aerogel slab to crack during drying.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerator Vacuum Windows: A Review of Past Research and a Strategy for the Development of a New Design for Improved Safety and Longevity for Particle Accelerators

Vacuum window research continues at Fermilab and this paper will examine cost effective, consistent designs which can have a huge impact on accelerator laboratories in terms of safety and cost. Issues such as the design, materials, analysis, testing and fabrication are addressed, including beam scattering plots and materials cost-benefit analysis and examining different materials which can potentially be substitutes for beryllium. A previous research paper has examined current fabrication and design techniques and also failure modes at Fermi, and this paper examines previous research in addition to emerging technologies. Many different paths have been taken by HEP Laboratories throughout the world with varying success. The history of vacuum window development is extensive and not well defined, and a matrix of what research has already been done on materials and joint design for vacuum windows will be shown. This report finally includes a treatise for vacuum window technology and a view towards emerging designs and materials and discusses future advances of research such as fabrication techniques including additive manufacturing and ultrasonic welding. Further exploration into these would prove beneficial to developing vacuum windows that are safer and stronger while being more transparent to the beam.

43 PARTICLE ACCELERATORS↗

Completing the Connected Home with Smart Window Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. Window attachment manufacturers currently offer motorized shading devices for certain product lines, but this automation is typically marketed as a convenience and security feature for the homeowner and often does not include energy optimized control algorithms or dynamic and responsive features. This paper describes the experimental results of testing the energy performance of high-efficiency, dynamically operated, cellular shades in Pacific Northwest National Laboratory’s (PNNL) Lab Homes. The results of both heating and cooling season experiments will be presented, where testing is designed to assess the whole home energy savings resulting from both the thermal insulating properties as well as the automated and dynamic control strategies of shading devices. Control schemes tested include common “connected home” strategies where controls are integrated and coordinated between the window shading device, building thermostats, and external sensors. The presentation will also include results from testing designed to examine the benefits (in terms of comfort, energy savings, and responsiveness) of coordinating the operation of cellular shades with HVAC as a demand-response measure. These experiments demonstrate that highly insulating, dynamic window coverings that are reliably controlled can dramatically reduce the heating and cooling energy associated with windows and should be considered an important component of any “smart” home design.

energy savings, cellular shades, honeycomb shades,↗